The use of a priori information in the detection of mammographic microcalcifications to improve their classification.

Abstract:

:In this work, we present a calcification-detection scheme that automatically localizes calcifications in a previously detected cluster in order to generate the input for a cluster-classification scheme developed in the past. The calcification-detection scheme makes use of three pieces of a priori information: the location of the center of the cluster, the size of the cluster, and the approximate number of calcifications in the cluster. This information can be obtained either automatically from a cluster-detection scheme or manually by a radiologist. It is used to analyze only the portion of the mammogram that contains a cluster and to identify the individual calcifications more accurately, after enhancing them by means of a "Difference of Gaussians" filter. Classification performances (patient-based Az=0.92; cluster-based Az=0.72) comparable to those obtained by using manually-identified calcifications (patient-based Az=0.92; cluster-based Az=0.82) can be achieved.

journal_name

Med Phys

journal_title

Medical physics

authors

Salfity MF,Nishikawa RM,Jiang Y,Papaioannou J

doi

10.1118/1.1559884

subject

Has Abstract

pub_date

2003-05-01 00:00:00

pages

823-31

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

30

pub_type

杂志文章
  • Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging.

    abstract:PURPOSE:The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892174

    authors: Cho HM,Barber WC,Ding H,Iwanczyk JS,Molloi S

    更新日期:2014-09-01 00:00:00

  • Low dose fraction behavior of high sensitivity radiochromic film.

    abstract::A high sensitivity (HS) model of radiochromic film is receiving increasing use. The film's linear sensitometric response in the range of 0.5-40 Gy would make this film an ideal candidate for complex dosimetry applications that require tissue equivalence. This study investigates the potential use for clinical dosimetry...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1883565

    authors: Hirata EY,Cunningham C,Micka JA,Keller H,Kissick MW,DeWerd LA

    更新日期:2005-04-01 00:00:00

  • Investigation of gamma knife image registration errors resulting from misalignment between the patient and the imaging axis.

    abstract::The ability of Leksell GammaPlan to perform stereotactic space localizations with image sets where there is misalignment of the patient's head (stereotactic frame and fiducial apparatus) relative to the computed tomography (CT) scanner coordinate system was studied. Misalignment is sometimes necessary for patient comf...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2179751

    authors: Cernica G,Wang Z,Malhotra H,de Boer S,Podgorsak MB

    更新日期:2006-04-01 00:00:00

  • Kilovoltage stereotactic radiosurgery for age-related macular degeneration: assessment of optic nerve dose and patient effective dose.

    abstract::Age-related macular degeneration (AMD) is a leading cause for vision loss for people over the age of 65 in the United States and a major health problem worldwide. Research for new treatments of the wet form of the disease using kilovoltage stereotactic radiosurgery is currently underway at Oraya Therapeutics, Inc. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3168554

    authors: Hanlon J,Lee C,Chell E,Gertner M,Hansen S,Howell RW,Bolch WE

    更新日期:2009-08-01 00:00:00

  • A Monte Carlo estimation of effective dose in chest tomosynthesis.

    abstract:PURPOSE:The recent introduction of digital tomosynthesis imaging into routine clinical use has enabled the acquisition of volumetric patient data within a standard radiographic examination. Tomosynthesis requires the acquisition of multiple projection views, requiring additional dose compared to a standard projection e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3250907

    authors: Sabol JM

    更新日期:2009-12-01 00:00:00

  • Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data.

    abstract::Receiver operating characteristic (ROC) methodology is widely used in evaluating medical imaging modalities. While appropriate in some cases, it has several drawbacks when the detection task, e.g., nodule detection, involves localizing the abnormality. Free-response receiver operating characteristic (FROC) methodology...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596358

    authors: Chakraborty DP

    更新日期:1989-07-01 00:00:00

  • Physical models, cross sections, and numerical approximations used in MCNP and GEANT4 Monte Carlo codes for photon and electron absorbed fraction calculation.

    abstract:PURPOSE:Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3242304

    authors: Yoriyaz H,Moralles M,Siqueira Pde T,Guimarães Cda C,Cintra FB,dos Santos A

    更新日期:2009-11-01 00:00:00

  • Image reconstruction algorithm for a rotating slat collimator.

    abstract::A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator sp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1485057

    authors: Zeng GL,Gagnon D,Matthews CG,Kolthammer JA,Radachy JD,Hawkins WG

    更新日期:2002-07-01 00:00:00

  • The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.

    abstract:PURPOSE:High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 μGy m(2)/h in a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822736

    authors: Espinoza A,Beeksma B,Petasecca M,Fuduli I,Porumb C,Cutajar D,Corde S,Jackson M,Lerch ML,Rosenfeld AB

    更新日期:2013-11-01 00:00:00

  • SU-E-T-555: Weighted Four-Dimensional IMRT Planning for Dynamic MLC Tracking Using a Practical and Simple Framework.

    abstract:PURPOSE:We present a simple, practical framework for truly 4D lung IMRT planning based on a weighted individual-phase optimization paradigm. This strategy is specifically developed for use in real-time tumor tracking delivery systems so as to utilize respiratory motion as an additional degree of freedom rather than a c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735644

    authors: Tachibana H,Cheung Y,Jain S,Sawant A

    更新日期:2012-06-01 00:00:00

  • Model-based optoacoustic inversion with arbitrary-shape detectors.

    abstract:PURPOSE:Optoacoustic imaging enables mapping the optical absorption of biological tissue using optical excitation and acoustic detection. Although most image-reconstruction algorithms are based on the assumption of a detector with an isotropic sensitivity, the geometry of the detector often leads to a response with spa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589141

    authors: Rosenthal A,Ntziachristos V,Razansky D

    更新日期:2011-07-01 00:00:00

  • Design and optimization of large area thin-film CdTe detector for radiation therapy imaging applications.

    abstract:PURPOSE:The authors investigate performance of thin-film cadmium telluride (CdTe) in detecting high-energy (6 MV) x rays. The utilization of this material has become technologically feasible only in recent years due to significant development in large area photovoltaic applications. METHODS:The CdTe film is combined w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3438082

    authors: Parsai EI,Shvydka D,Kang J

    更新日期:2010-08-01 00:00:00

  • Computerized detection of masses in digital mammograms: automated alignment of breast images and its effect on bilateral-subtraction technique.

    abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597307

    authors: Yin FF,Giger ML,Doi K,Vyborny CJ,Schmidt RA

    更新日期:1994-03-01 00:00:00

  • Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy.

    abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13299

    authors: Cheung JP,Shugard E,Mistry N,Pouliot J,Chen J

    更新日期:2019-02-01 00:00:00

  • Resolution of pinhole collimators used with gamma cameras.

    abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594755

    authors: Goulet P,Joy ML

    更新日期:1980-09-01 00:00:00

  • Spacing nomograph for interstitial implants of 125I seeds.

    abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594269

    authors: Anderson LL

    更新日期:1976-01-01 00:00:00

  • An automatic seed finder for brachytherapy CT postplans based on the Hough transform.

    abstract:PURPOSE:The purpose of the work is to describe a new algorithm for the automatic detection of implanted radioactive seeds within the prostate. The algorithm is based on the traditional Hough transform. A method of quality assurance is described as well as a quantitative phantom study to determine the accuracy of the al...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1778837

    authors: Holupka EJ,Meskell PM,Burdette EC,Kaplan ID

    更新日期:2004-09-01 00:00:00

  • Iodine quantification in limited angle tomography.

    abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14400

    authors: Michielsen K,Rodríguez-Ruiz A,Reiser I,Nagy JG,Sechopoulos I

    更新日期:2020-10-01 00:00:00

  • Backscatter factors in the mammographic energy range.

    abstract::Backscatter factors for kVps and half-value layers typical of mammographic beams have been determined as a function of beam diameter and half-value layer. The method utilized thin TLD-100 chips with the scattering medium alternately present and absent. Results indicate that the field-size dependence of the backscatter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594312

    authors: Dubuque GL,Cacak RK,Hendee WR

    更新日期:1977-09-01 00:00:00

  • Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy.

    abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870378

    authors: Goodsitt MM,Shenoy A,Shen J,Howard D,Schipper MJ,Wilderman S,Christodoulou E,Chun SY,Dewaraja YK

    更新日期:2014-05-01 00:00:00

  • GateCT™ surface tracking system for respiratory signal reconstruction in 4DCT imaging.

    abstract:PURPOSE:To assess the temporal and spatial accuracy of the GateCT™ system (VisionRT, London, UK), a recently released respiratory tracking system for 4DCT, under both ideal and nonideal respiratory conditions. METHODS:Three experiments were performed by benchmarking and comparing its results with the ground-truth inpu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3671941

    authors: Kauweloa KI,Ruan D,Park JC,Sandhu A,Kim GY,Pawlicki T,Watkins WT,Song B,Song WY

    更新日期:2012-01-01 00:00:00

  • Noise texture and signal detectability in propagation-based x-ray phase-contrast tomography.

    abstract:PURPOSE:X-ray phase-contrast tomography (PCT) is a rapidly emerging imaging modality for reconstructing estimates of an object's three-dimensional x-ray refractive index distribution. Unlike conventional x-ray computed tomography methods, the statistical properties of the reconstructed images in PCT remain unexplored. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3267548

    authors: Chou CY,Anastasio MA

    更新日期:2010-01-01 00:00:00

  • Novel methods of measuring single scan dose profiles and cumulative dose in CT.

    abstract::Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1835571

    authors: Nakonechny KD,Fallone BG,Rathee S

    更新日期:2005-01-01 00:00:00

  • Low-complexity atlas-based prostate segmentation by combining global, regional, and local metrics.

    abstract:PURPOSE:To improve the efficiency of atlas-based segmentation without compromising accuracy, and to demonstrate the validity of the proposed method on MRI-based prostate segmentation application. METHODS:Accurate and efficient automatic structure segmentation is an important task in medical image processing. Atlas-bas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4867855

    authors: Xie Q,Ruan D

    更新日期:2014-04-01 00:00:00

  • Robust initialization of 2D-3D image registration using the projection-slice theorem and phase correlation.

    abstract:PURPOSE:The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a succe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3366252

    authors: van der Bom MJ,Bartels LW,Gounis MJ,Homan R,Timmer J,Viergever MA,Pluim JP

    更新日期:2010-04-01 00:00:00

  • Fourier transform infrared imaging and small angle x-ray scattering as a combined biomolecular approach to diagnosis of breast cancer.

    abstract::Fourier transform infrared (FTIR) microspectroscopic imaging and small angle x-ray scattering (SAXS) were combined to investigate the supramolecular structure of collagen from 27 tissue sections from patients undergoing mastectomy, excisional biopsy, or mammoplasty. Both techniques were correlated by matching the scat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2890391

    authors: Ooi GJ,Fox J,Siu K,Lewis R,Bambery KR,McNaughton D,Wood BR

    更新日期:2008-05-01 00:00:00

  • A CdZnTe slot-scanned detector for digital mammography.

    abstract::A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1523932

    authors: Mainprize JG,Ford NL,Yin S,Gordon EE,Hamilton WJ,Tümer TO,Yaffe MJ

    更新日期:2002-12-01 00:00:00

  • MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility.

    abstract::Preclinical experiments are carried out with approximately 20-30 microm wide, approximately 10 mm high parallel microbeams of hard, broad-"white"-spectrum x rays (approximately 50-600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1562169

    authors: Bräuer-Krisch E,Bravin A,Lerch M,Rosenfeld A,Stepanek J,Di Michiel M,Laissue JA

    更新日期:2003-04-01 00:00:00

  • Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

    abstract:PURPOSE:Design and optimization of medical imaging systems benefit from accurate theoretical modeling that identifies the physical factors governing image quality, particularly in the early stages of system development. This work extends Fourier metrics of imaging performance and detectability index (d') to tomosynthes...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3560428

    authors: Gang GJ,Lee J,Stayman JW,Tward DJ,Zbijewski W,Prince JL,Siewerdsen JH

    更新日期:2011-04-01 00:00:00

  • Tissue-mimicking gelatin-agar gels for use in magnetic resonance imaging phantoms.

    abstract::A new variety of tissue-mimicking materials for use in 1H nuclear magnetic resonance (NMR) phantoms has been developed and extensively tested, principally at 10 MHz and at room temperature. The materials can be formed with a broad range of T1's and T2's representative of soft tissues. They are mixtures of various perc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596219

    authors: Blechinger JC,Madsen EL,Frank GR

    更新日期:1988-07-01 00:00:00