An automatic seed finder for brachytherapy CT postplans based on the Hough transform.

Abstract:

PURPOSE:The purpose of the work is to describe a new algorithm for the automatic detection of implanted radioactive seeds within the prostate. The algorithm is based on the traditional Hough transform. A method of quality assurance is described as well as a quantitative phantom study to determine the accuracy of the algorithm. METHODS AND MATERIALS:An algorithm is described which is based on the Hough transform. The Hough transform is a well known transform traditionally used to automatically segment lines and other well defined geometric objects from images. The traditional Hough transform is extended to three-dimensions and applied to CT images of seed implanted prostate glands. A method based on digitally reconstructed radiographs is described to quality assure the determined three-dimensional positions of the detected seeds. Two phantom studies utilizing eight seeds and nine seeds are described. All eight seeds form a contiguous a square while the nine seed phantom describes seeds which are placed side-by-side in groups of two and three. The algorithm is applied to the CT scans of both phantoms and the seed positions determined. RESULTS:The algorithm has been commercially developed and used to perform postsurgical dosimetric assessment on approximately 1000 patients. Using the described quality assurance tool it was determined that the algorithm accurately determined the seed positions in all 1000 patients. The algorithm was also applied to the eight seed phantom. The algorithm successfully found all eight seeds as well as their seed coordinates. The average radial error was determined to be 0.9 mm. For the nine seed phantom, the algorithm correctly identified all nine seeds, with an average radial error of 3 mm. CONCLUSIONS:The described algorithm is a robust, accurate, automatic, three-dimensional application for CT based seed determination.

journal_name

Med Phys

journal_title

Medical physics

authors

Holupka EJ,Meskell PM,Burdette EC,Kaplan ID

doi

10.1118/1.1778837

subject

Has Abstract

pub_date

2004-09-01 00:00:00

pages

2672-9

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

31

pub_type

临床试验,杂志文章
  • Assessment of image registration accuracy in three-dimensional transrectal ultrasound guided prostate biopsy.

    abstract:PURPOSE:Prostate biopsy, performed using two-dimensional (2D) transrectal ultrasound (TRUS) guidance, is the clinical standard for a definitive diagnosis of prostate cancer. Histological analysis of the biopsies can reveal cancerous, noncancerous, or suspicious, possibly precancerous, tissue. During subsequent biopsy s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3298010

    authors: Karnik VV,Fenster A,Bax J,Cool DW,Gardi L,Gyacskov I,Romagnoli C,Ward AD

    更新日期:2010-02-01 00:00:00

  • Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905050

    authors: Veiga C,Lourenço AM,Mouinuddin S,van Herk M,Modat M,Ourselin S,Royle G,McClelland JR

    更新日期:2015-02-01 00:00:00

  • Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.

    abstract::The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous sil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2147744

    authors: Wendling M,Louwe RJ,McDermott LN,Sonke JJ,van Herk M,Mijnheer BJ

    更新日期:2006-02-01 00:00:00

  • Simultaneous super-resolution and contrast synthesis of routine clinical magnetic resonance images of the knee for improving automatic segmentation of joint cartilage: data from the Osteoarthritis Initiative.

    abstract:PURPOSE:High resolution three-dimensional (3D) magnetic resonance (MR) images are well suited for automated cartilage segmentation in the human knee joint. However, volumetric scans such as 3D Double-Echo Steady-State (DESS) images are not routinely acquired in clinical practice which limits opportunities for reliable ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14421

    authors: Neubert A,Bourgeat P,Wood J,Engstrom C,Chandra SS,Crozier S,Fripp J

    更新日期:2020-10-01 00:00:00

  • Poster - Thurs Eve-32: Dose errors related to the treatment couch.

    abstract::Modern radiotherapy linacs often use carbon fibre for their couch tops due to its radio translucent properties. Beam attenuation by the couches is often ignored during planning and MU calculation. This work examines beam attenuation and loss of "skin sparing" (dose build up region) when various photon beams transit ei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965951

    authors: Niedbala M,Nyiri B,Gerig L

    更新日期:2008-07-01 00:00:00

  • Harmonic phase angle as a concentration-independent measure of nanoparticle dynamics.

    abstract:PURPOSE:The harmonic spectrum of magnetic nanoparticles contains valuable information about the quantity and environment of the particles. Harmonic amplitudes have been used to produce quantitative images and ratios of these amplitudes have been used to monitor changes in the particle environment. Harmonic phase angles...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3426294

    authors: Rauwerdink AM,Weaver JB

    更新日期:2010-06-01 00:00:00

  • Mixed model phase evolution for correction of magnetic field inhomogeneity effects in 3D quantitative gradient echo-based MRI.

    abstract:PURPOSE:In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* es...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12318

    authors: Fatnassi C,Boucenna R,Zaidi H

    更新日期:2017-07-01 00:00:00

  • Matching photon and electron fields with dynamic intensity modulation.

    abstract::A technique was developed to reduce the size and magnitude of the hot and cold spots in the abutting regions of photon and electron fields. The photon and electron fields were set up such that the photon field extended approximately 2 cm into the electron field in the abutting region. The region of the photon beam tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598753

    authors: Li JG,Xing L,Boyer AL,Hamilton RJ,Spelbring DR,Turian JV

    更新日期:1999-11-01 00:00:00

  • What is the optimum leaf width of a multileaf collimator?

    abstract:UNLABELLED:The following question is investigated: How narrow do the leaves of a multileaf collimator have to be such that further reduction of the leaf width does not lead to physical improvements of the dose distribution. Because of the physical principles of interaction between radiation and matter, dose distributio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1319524

    authors: Bortfeld T,Oelfke U,Nill S

    更新日期:2000-11-01 00:00:00

  • Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging.

    abstract::Skin entrance doses of patients undergoing interventional x-ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x-ray energies fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597973

    authors: Geise RA,Schueler BA,Lien W,Jones SC

    更新日期:1997-10-01 00:00:00

  • Sci-Thur PM: YIS - 08: The effect of copper conversion plates on low-Z target image quality.

    abstract::Current generation electronic portal imaging devices (EPID) contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When using these EPIDs for low-Z target imaging, the conversion plate largely attenuates the large populations of diagnostic energy photons, there...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740105

    authors: Parsons D,Robar JL

    更新日期:2012-07-01 00:00:00

  • Pulmonary nodule detection in CT images based on shape constraint CV model.

    abstract:PURPOSE:Accurate detection of pulmonary nodules remains a technical challenge in computer-aided diagnosis systems because some nodules may adhere to the blood vessels or the lung wall, which have low contrast compared to the surrounding tissues. In this paper, the analysis of typical shape features of candidate nodules...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4907961

    authors: Wang B,Tian X,Wang Q,Yang Y,Xie H,Zhang S,Gu L

    更新日期:2015-03-01 00:00:00

  • Material elemental decomposition in dual and multi-energy CT via a sparsity-dictionary approach for proton stopping power ratio calculation.

    abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12796

    authors: Shen C,Li B,Chen L,Yang M,Lou Y,Jia X

    更新日期:2018-04-01 00:00:00

  • The effects of different correction techniques on absolute volume determination with SPECT using a threshold edge detection method.

    abstract::Quantitation of planar radionuclide images is hampered by structures containing radioactivity which overlie or underlie the organ of interest. The introduction of single photon emission computerized tomography (SPECT) overcame this problem to a large extent and enhanced the contrast of the images. Attenuation of photo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596684

    authors: Pretorius PH,van Aswegen AI,Herbst CP,Lötter MG

    更新日期:1991-05-01 00:00:00

  • SU-E-J-58: Patient-Specific Biomechanical Head and Neck Models for Interfraction Dose Accumulation.

    abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734893

    authors: Santhanam A,Ennis D,Low D,Kupelian P

    更新日期:2012-06-01 00:00:00

  • Dosimetric properties of radiophotoluminescent glass detector in low-energy photon beams.

    abstract:PURPOSE:A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4747261

    authors: Kadoya N,Shimomura K,Kitou S,Shiota Y,Fujita Y,Dobashi S,Takeda K,Jingu K,Matsushita H,Namito Y,Ban S,Koyama S,Tabushi K

    更新日期:2012-10-01 00:00:00

  • Measurement of dose distributions using film in therapeutic electron beams.

    abstract::The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596409

    authors: Shiu AS,Otte VA,Hogstrom KR

    更新日期:1989-11-01 00:00:00

  • Novel scintillation detector design and performance for proton radiography and computed tomography.

    abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939255

    authors: Bashkirov VA,Schulte RW,Hurley RF,Johnson RP,Sadrozinski HF,Zatserklyaniy A,Plautz T,Giacometti V

    更新日期:2016-02-01 00:00:00

  • Uncertainties in IMRT dosimetry.

    abstract:PURPOSE:The purpose of this study is to investigate some characteristics of the beam delivery system and their effects on the dose distribution of intensity-modulated radiation therapy (IMRT) and the results of patient-specific IMRT quality assurance (QA). These characteristics include the accelerator source distributi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3413997

    authors: Li JS,Lin T,Chen L,Price RA Jr,Ma CM

    更新日期:2010-06-01 00:00:00

  • Quantitative ionization chamber alignment to a water surface: Theory and simulation.

    abstract:PURPOSE:To examine the response properties of cylindrical cavity ionization chambers (ICs) in the depth-ionization buildup region so as to obtain a robust chamber-signal - based method for definitive water surface identification, hence absolute ionization chamber depth localization. METHOD & MATERIALS:An analytical mo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12319

    authors: Siebers JV,Ververs JD,Tessier F

    更新日期:2017-07-01 00:00:00

  • Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy.

    abstract:PURPOSE:Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754799

    authors: Fogliata A,Garcia R,Knoos T,Nicolini G,Clivio A,Vanetti E,Khamphan C,Cozzi L

    更新日期:2012-10-01 00:00:00

  • Resolution of pinhole collimators used with gamma cameras.

    abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594755

    authors: Goulet P,Joy ML

    更新日期:1980-09-01 00:00:00

  • Investigation of intensity-modulated radiotherapy optimization with gEUD-based objectives by means of simulated annealing.

    abstract::Inverse treatment planning of intensity-modulated radiation therapy (IMRT) is complicated by several sources of error, which can cause deviations of optimized plans from the true optimal solution. These errors include the systematic and convergence error, the local minima error, and the optimizer convergence error. We...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2896070

    authors: Hartmann M,Bogner L

    更新日期:2008-05-01 00:00:00

  • Photon-beam subsource sensitivity to the initial electron-beam parameters.

    abstract::One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC sour...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1884385

    authors: Fix MK,Keall PJ,Siebers JV

    更新日期:2005-04-01 00:00:00

  • Effect of phantom voxelization in CT simulations.

    abstract::In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1461841

    authors: Goertzen AL,Beekman FJ,Cherry SR

    更新日期:2002-04-01 00:00:00

  • Modeling acute and chronic hypoxia using serial images of 18F-FMISO PET.

    abstract:PURPOSE:Two types of tumor hypoxia most likely exist in human cancers: Chronic hypoxia due to the paucity of blood capillaries and acute hypoxia due to temporary shutdoWn of microvasculatures or fluctuation in the red cell flux. In a recent hypoxia imaging study using 18F-FMISO PET, the authors observed variation in tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3213092

    authors: Wang K,Yorke E,Nehmeh SA,Humm JL,Ling CC

    更新日期:2009-10-01 00:00:00

  • Analysis of the significance of scattered radiation in reduced dose mammography, including magnification effects, scatter suppression, and focal spot and detector blurring.

    abstract::A systems analysis of reduced dose mammography with scatter removal has quantitatively specified the relationships between the several parameters in mammography systems. While the results are only preliminary in the sense that they need to be proven experimentally, they do seem to provide a good feel for the nature of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594540

    authors: Muntz EP

    更新日期:1979-03-01 00:00:00

  • Sensitivities in the production of spread-out Bragg peak dose distributions by passive scattering with beam current modulation.

    abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2776255

    authors: Lu HM,Brett R,Engelsman M,Slopsema R,Kooy H,Flanz J

    更新日期:2007-10-01 00:00:00

  • Higher energy: is it necessary, is it worth the cost for radiation oncology?

    abstract::The physical characteristics of the interactions of megavoltage photons and electrons with matter provide distinct advantages, relative to low-energy (orthovoltage) x rays, that lead to better radiation dose distributions in patients. Use of these high-energy radiations has resulted in better patient care, which has b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596779

    authors: Das IJ,Kase KR

    更新日期:1992-07-01 00:00:00

  • Inspection of visible components in urine based on deep learning.

    abstract:PURPOSE:Urinary particles are particularly important parameters in clinical urinalysis, especially for the diagnosis of nephropathy. Therefore, it is highly important to precisely detect urinary particles in the clinical setting. However, artificial microscopy is subjective and time consuming, and various previous dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14118

    authors: Li Q,Yu Z,Qi T,Zheng L,Qi S,He Z,Li S,Guan H

    更新日期:2020-07-01 00:00:00