Abstract:
PURPOSE:The purpose of the work is to describe a new algorithm for the automatic detection of implanted radioactive seeds within the prostate. The algorithm is based on the traditional Hough transform. A method of quality assurance is described as well as a quantitative phantom study to determine the accuracy of the algorithm. METHODS AND MATERIALS:An algorithm is described which is based on the Hough transform. The Hough transform is a well known transform traditionally used to automatically segment lines and other well defined geometric objects from images. The traditional Hough transform is extended to three-dimensions and applied to CT images of seed implanted prostate glands. A method based on digitally reconstructed radiographs is described to quality assure the determined three-dimensional positions of the detected seeds. Two phantom studies utilizing eight seeds and nine seeds are described. All eight seeds form a contiguous a square while the nine seed phantom describes seeds which are placed side-by-side in groups of two and three. The algorithm is applied to the CT scans of both phantoms and the seed positions determined. RESULTS:The algorithm has been commercially developed and used to perform postsurgical dosimetric assessment on approximately 1000 patients. Using the described quality assurance tool it was determined that the algorithm accurately determined the seed positions in all 1000 patients. The algorithm was also applied to the eight seed phantom. The algorithm successfully found all eight seeds as well as their seed coordinates. The average radial error was determined to be 0.9 mm. For the nine seed phantom, the algorithm correctly identified all nine seeds, with an average radial error of 3 mm. CONCLUSIONS:The described algorithm is a robust, accurate, automatic, three-dimensional application for CT based seed determination.
journal_name
Med Physjournal_title
Medical physicsauthors
Holupka EJ,Meskell PM,Burdette EC,Kaplan IDdoi
10.1118/1.1778837subject
Has Abstractpub_date
2004-09-01 00:00:00pages
2672-9issue
9eissn
0094-2405issn
2473-4209journal_volume
31pub_type
临床试验,杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Prostate biopsy, performed using two-dimensional (2D) transrectal ultrasound (TRUS) guidance, is the clinical standard for a definitive diagnosis of prostate cancer. Histological analysis of the biopsies can reveal cancerous, noncancerous, or suspicious, possibly precancerous, tissue. During subsequent biopsy s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3298010
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905050
更新日期:2015-02-01 00:00:00
abstract::The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous sil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2147744
更新日期:2006-02-01 00:00:00
abstract:PURPOSE:High resolution three-dimensional (3D) magnetic resonance (MR) images are well suited for automated cartilage segmentation in the human knee joint. However, volumetric scans such as 3D Double-Echo Steady-State (DESS) images are not routinely acquired in clinical practice which limits opportunities for reliable ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14421
更新日期:2020-10-01 00:00:00
abstract::Modern radiotherapy linacs often use carbon fibre for their couch tops due to its radio translucent properties. Beam attenuation by the couches is often ignored during planning and MU calculation. This work examines beam attenuation and loss of "skin sparing" (dose build up region) when various photon beams transit ei...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965951
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:The harmonic spectrum of magnetic nanoparticles contains valuable information about the quantity and environment of the particles. Harmonic amplitudes have been used to produce quantitative images and ratios of these amplitudes have been used to monitor changes in the particle environment. Harmonic phase angles...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3426294
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* es...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12318
更新日期:2017-07-01 00:00:00
abstract::A technique was developed to reduce the size and magnitude of the hot and cold spots in the abutting regions of photon and electron fields. The photon and electron fields were set up such that the photon field extended approximately 2 cm into the electron field in the abutting region. The region of the photon beam tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598753
更新日期:1999-11-01 00:00:00
abstract:UNLABELLED:The following question is investigated: How narrow do the leaves of a multileaf collimator have to be such that further reduction of the leaf width does not lead to physical improvements of the dose distribution. Because of the physical principles of interaction between radiation and matter, dose distributio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1319524
更新日期:2000-11-01 00:00:00
abstract::Skin entrance doses of patients undergoing interventional x-ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x-ray energies fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597973
更新日期:1997-10-01 00:00:00
abstract::Current generation electronic portal imaging devices (EPID) contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When using these EPIDs for low-Z target imaging, the conversion plate largely attenuates the large populations of diagnostic energy photons, there...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740105
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:Accurate detection of pulmonary nodules remains a technical challenge in computer-aided diagnosis systems because some nodules may adhere to the blood vessels or the lung wall, which have low contrast compared to the surrounding tissues. In this paper, the analysis of typical shape features of candidate nodules...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4907961
更新日期:2015-03-01 00:00:00
abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12796
更新日期:2018-04-01 00:00:00
abstract::Quantitation of planar radionuclide images is hampered by structures containing radioactivity which overlie or underlie the organ of interest. The introduction of single photon emission computerized tomography (SPECT) overcame this problem to a large extent and enhanced the contrast of the images. Attenuation of photo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596684
更新日期:1991-05-01 00:00:00
abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734893
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4747261
更新日期:2012-10-01 00:00:00
abstract::The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596409
更新日期:1989-11-01 00:00:00
abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939255
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:The purpose of this study is to investigate some characteristics of the beam delivery system and their effects on the dose distribution of intensity-modulated radiation therapy (IMRT) and the results of patient-specific IMRT quality assurance (QA). These characteristics include the accelerator source distributi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3413997
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:To examine the response properties of cylindrical cavity ionization chambers (ICs) in the depth-ionization buildup region so as to obtain a robust chamber-signal - based method for definitive water surface identification, hence absolute ionization chamber depth localization. METHOD & MATERIALS:An analytical mo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12319
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754799
更新日期:2012-10-01 00:00:00
abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594755
更新日期:1980-09-01 00:00:00
abstract::Inverse treatment planning of intensity-modulated radiation therapy (IMRT) is complicated by several sources of error, which can cause deviations of optimized plans from the true optimal solution. These errors include the systematic and convergence error, the local minima error, and the optimizer convergence error. We...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2896070
更新日期:2008-05-01 00:00:00
abstract::One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC sour...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1884385
更新日期:2005-04-01 00:00:00
abstract::In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1461841
更新日期:2002-04-01 00:00:00
abstract:PURPOSE:Two types of tumor hypoxia most likely exist in human cancers: Chronic hypoxia due to the paucity of blood capillaries and acute hypoxia due to temporary shutdoWn of microvasculatures or fluctuation in the red cell flux. In a recent hypoxia imaging study using 18F-FMISO PET, the authors observed variation in tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3213092
更新日期:2009-10-01 00:00:00
abstract::A systems analysis of reduced dose mammography with scatter removal has quantitatively specified the relationships between the several parameters in mammography systems. While the results are only preliminary in the sense that they need to be proven experimentally, they do seem to provide a good feel for the nature of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594540
更新日期:1979-03-01 00:00:00
abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2776255
更新日期:2007-10-01 00:00:00
abstract::The physical characteristics of the interactions of megavoltage photons and electrons with matter provide distinct advantages, relative to low-energy (orthovoltage) x rays, that lead to better radiation dose distributions in patients. Use of these high-energy radiations has resulted in better patient care, which has b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596779
更新日期:1992-07-01 00:00:00
abstract:PURPOSE:Urinary particles are particularly important parameters in clinical urinalysis, especially for the diagnosis of nephropathy. Therefore, it is highly important to precisely detect urinary particles in the clinical setting. However, artificial microscopy is subjective and time consuming, and various previous dete...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14118
更新日期:2020-07-01 00:00:00