SU-E-J-58: Patient-Specific Biomechanical Head and Neck Models for Interfraction Dose Accumulation.

Abstract:

PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and validation. The MRI data allowed us to build a biomechanically predictive model that will enable accurate estimation of tumor position when seeded with CT data alone. The soft tissue contrast and lack of ionizing radiation when using MRI enabled us to acquire extensive imaging datasets with a suitable variety of head pose variations. These poses were selected to encompass the clinical positioning variations so that the resulting model will accurately reflect internal organ motion and deformation. All images were acquired using an 8-channel, 1.5T research MRI system in radiology. The imaging volume extended from about T3(upper thoracic vertebrae) to the top of the head, thereby covering the entire head and neck. Model components included: muscles, skeletal bones, lymph nodes, fat tissues, and organs such as salivary glands, tendons, andligaments. At first, one MRI image dataset was selected as the reference image. The biometric properties (length, volume, mass, shape), hinge constraints of the bones, and the biomechanical properties of each of the anatomies were estimated using MRIs acquired at different head and neck poses. RESULTS:The model's ability to represent different head and neck postures can be illustrated by observing the internal tissue deformations andthe model's ability to represent different postures. CONCLUSIONS:Results show that the biomechanical model was able to simulate different poses that may be exhibited during interfraction patient setup variations and intrafraction patient motion. Future work would focus on integrating dose calculations on the deforming model and validating the model deformations.

journal_name

Med Phys

journal_title

Medical physics

authors

Santhanam A,Ennis D,Low D,Kupelian P

doi

10.1118/1.4734893

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3665

issue

6Part6

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • SU-D-211-06: The Effect of Motion in RapidArc Lung SBRT Delivery.

    abstract:PURPOSE:RapidArc is routinely used for stereotactic radiotherapy for lung cancer. While treatment dose is optimized and calculated on a static CT image, the motion of the target in conjunction with the motion of the MLC may Result in a delivered dose deviating from the planed dose. In this study, we investigate the dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734660

    authors: Zou J,Yin L,Shen J,Corradetti M,Kirk M,Rengan R,Teo BK

    更新日期:2012-06-01 00:00:00

  • Proton magnetic resonance spectroscopy in the brain: report of AAPM MR Task Group #9.

    abstract::AAPM Magnetic Resonance Task Group #9 on proton magnetic resonance spectroscopy (MRS) in the brain was formed to provide a reference document for acquiring and processing proton (1H) MRS acquired from brain tissue. MRS is becoming a common adjunct to magnetic resonance imaging (MRI), especially for the differential di...

    journal_title:Medical physics

    pub_type: 指南,杂志文章,实务指引,评审

    doi:10.1118/1.1501822

    authors: Drost DJ,Riddle WR,Clarke GD,AAPM MR Task Group #9.

    更新日期:2002-09-01 00:00:00

  • SU-E-I-99: An Ultra-High Resolution Small Field-Of-View Solid State X-Ray Imaging Detector Based on an Electron Multiplying CCD.

    abstract:PURPOSE:To demonstrate the ultra-high resolution capability of a small field-of-view (FOV) solid state x-ray imaging detector based on an EMCCD sensor. METHODS:A micro-solid state x-ray image intensifier (micro-SSXII) was developed to serve as an ultra-high resolution region-of-interest (ROI) imaging detector. It is b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734816

    authors: Singh V,Loughran B,Jain A,Sharma P,Bednarek D,Rudin S

    更新日期:2012-06-01 00:00:00

  • Monte Carlo based IMRT dose verification using MLC log files and R/V outputs.

    abstract::Conventional IMRT dose verification using film and ion chamber measurements is useful but limited with respect to the actual dose distribution received by the patient. The Monte Carlo simulation has been introduced as an independent dose verification tool for IMRT using the patient CT data and MLC leaf sequence files,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2208916

    authors: Luo W,Li J,Price RA Jr,Chen L,Yang J,Fan J,Chen Z,McNeeley S,Xu X,Ma CM

    更新日期:2006-07-01 00:00:00

  • Improved gradient-echo 3D magnetic resonance imaging using compressed sensing and Toeplitz encoding with phase-scrambled RF excitation.

    abstract:PURPOSE:To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13987

    authors: Wang H,Liang D,Su S,King KF,Chang Y,Liu X,Zheng H,Ying L

    更新日期:2020-04-01 00:00:00

  • What is the optimum leaf width of a multileaf collimator?

    abstract:UNLABELLED:The following question is investigated: How narrow do the leaves of a multileaf collimator have to be such that further reduction of the leaf width does not lead to physical improvements of the dose distribution. Because of the physical principles of interaction between radiation and matter, dose distributio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1319524

    authors: Bortfeld T,Oelfke U,Nill S

    更新日期:2000-11-01 00:00:00

  • Maximum likelihood estimation in calibrating a stereo camera setup.

    abstract::Motion and deformation of the cardiac wall may be measured by following the positions of implanted radiopaque markers in three dimensions, using two x-ray cameras simultaneously. Regularly, calibration of the position measurement system is obtained by registration of the images of a calibration object, containing 10-2...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598518

    authors: Muijtjens AM,Roos JM,Arts T,Hasman A

    更新日期:1999-02-01 00:00:00

  • Use of proximal operator graph solver for radiation therapy inverse treatment planning.

    abstract:PURPOSE:Most radiation therapy optimization problems can be formulated as an unconstrained problem and solved efficiently by quasi-Newton methods such as the Limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. However, several next generation planning techniques such as total variation regularization- b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12165

    authors: Liu X,Pelizzari C,Belcher AH,Grelewicz Z,Wiersma RD

    更新日期:2017-04-01 00:00:00

  • An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan.

    abstract:PURPOSE:Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754797

    authors: Lewis D,Micke A,Yu X,Chan MF

    更新日期:2012-10-01 00:00:00

  • On the speckle-free nature of photoacoustic tomography.

    abstract:PURPOSE:A long-standing conundrum is why photoacoustic tomography (PAT) possesses the unique ability to produce images devoid of speckle artifacts while all other coherent imaging technologies do not. METHODS:In this paper, we explain the inherent mechanism that suppresses speckle in PAT, and the analysis was validate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3187231

    authors: Guo Z,Li L,Wang LV

    更新日期:2009-09-01 00:00:00

  • Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

    abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3002314

    authors: Wronski MM,Rowlands JA

    更新日期:2008-12-01 00:00:00

  • Measurement of the replacement correction factor for parallel-plate chambers in electron fields.

    abstract::When parallel-plate chambers are used for dosimetry in electron fields, the AAPM dosimetry protocol recommends a value of 1.0 for the replacement correction factor, P(repl),pp,E, until further data become available. Here, P(repl),pp,E for five commercially available parallel-plate chambers was measured as a function o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596740

    authors: Reft CS,Kuchnir FT

    更新日期:1991-11-01 00:00:00

  • Flattening filter removal for improved image quality of megavoltage fluoroscopy.

    abstract:PURPOSE:Removal of the linear accelerator (linac) flattening filter enables a high rate of dose deposition with reduced treatment time. When used for megavoltage imaging, an unflat beam has reduced primary beam scatter resulting in sharper images. In fluoroscopic imaging mode, the unflat beam has higher photon count pe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4812678

    authors: Christensen JD,Kirichenko A,Gayou O

    更新日期:2013-08-01 00:00:00

  • Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring.

    abstract::Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved ...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4935869

    authors: Parodi K

    更新日期:2015-12-01 00:00:00

  • High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    abstract:PURPOSE:The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋm ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋp ) o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12066

    authors: Jaccard M,Petersson K,Buchillier T,Germond JF,Durán MT,Vozenin MC,Bourhis J,Bochud FO,Bailat C

    更新日期:2017-02-01 00:00:00

  • Poster - Thurs Eve-04: Mathematical modeling of liver metastases tumour growth and control with radiotherapy.

    abstract::Generating an optimized radiation treatment plan requires understanding the factors affecting tumour control. Mathematical models of tumour dynamics may help in future studies of factors predicting tumor sensitivity to radiotherapy. In this study, a time-dependent differential model, incorporating biological cancer ma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965923

    authors: Campbell A,Davidson M,Lock M,Wong E

    更新日期:2008-07-01 00:00:00

  • SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators.

    abstract:PURPOSE:Quantitative SPECT imaging is limited by many factors, including penetration of high energy photons through the collimator. Even small peaks of high energy yield extensive contamination in the photopeak energy window. Rotating slat collimators typically offer a 40- to 50-fold increase in geometric detection eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3177312

    authors: Van Holen R,Staelens S,Vandenberghe S

    更新日期:2009-09-01 00:00:00

  • SU-E-I-69: Magnetic Resonance Metal Artifact Evaluation with Routine Clinical Cardiac Sequences.

    abstract:PURPOSE:To examine schemes to grade the severity of metal susceptibility artifacts on image quality using cardiac MRI pulse sequences. METHODS:A post-thoracotomy patient was simulated with a stainless steel sternal wire (Syneture,MA; size=6, diameter=48mm), placed securely on an ACR MRI phantom. Phantom was scanned on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734785

    authors: Joyner D,Rivard A,Craft D,Liu T,Callaway S,James J

    更新日期:2012-06-01 00:00:00

  • Daily check instrument for photon and electron beam quality assurance of medical linacs.

    abstract::An instrument for daily beam checks of medical accelerators is described. Using three silicon diodes, the instrument provides information about calibration, beam symmetry, flatness, and energy variation for both photon and electron beams. Operating characteristics of the instrument and the electronic circuit design pe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595756

    authors: Lutz WR,Maddox BJ,Kase KR

    更新日期:1985-07-01 00:00:00

  • Application of spherical diodes for megavoltage photon beams dosimetry.

    abstract:PURPOSE:External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A hi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4837178

    authors: Barbés B,Azcona JD,Burguete J,Martí-Climent JM

    更新日期:2014-01-01 00:00:00

  • Evaluation of the local dose enhancement in the combination of proton therapy and nanoparticles.

    abstract:PURPOSE:The outcome of radiotherapy can be further improved by combining irradiation with dose enhancers such as high-Z nanoparticles. Since 2004, spectacular results have been obtained when low-energy x-ray irradiations have been combined with nanoparticles. Recently, the same combination has been explored in hadron t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4934370

    authors: Martínez-Rovira I,Prezado Y

    更新日期:2015-11-01 00:00:00

  • Multiattribute probabilistic prostate elastic registration (MAPPER): application to fusion of ultrasound and magnetic resonance imaging.

    abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905104

    authors: Sparks R,Bloch BN,Feleppa E,Barratt D,Moses D,Ponsky L,Madabhushi A

    更新日期:2015-03-01 00:00:00

  • Use of simulated annealing for optimization of alignment parameters in limited MRI acquisition volumes of the brain.

    abstract::Studies suggest that clinical outcomes are improved in repeat trigeminal neuralgia (TN) Gamma Knife radiosurgery if a different part of the nerve from the previous radiosurgery is treated. The MR images taken in the first and repeat radiosurgery need to be coregistered to map the first radiosurgery volume onto the sec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1944287

    authors: Li X,Zhang P,Brisman R,Kutcher G

    更新日期:2005-07-01 00:00:00

  • 4D rotational x-ray imaging of wrist joint dynamic motion.

    abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2000647

    authors: Carelsen B,Bakker NH,Strackee SD,Boon SN,Maas M,Sabczynski J,Grimbergen CA,Streekstra GJ

    更新日期:2005-09-01 00:00:00

  • A topographic leaf-sequencing algorithm for delivering intensity modulated radiation therapy.

    abstract::Topographic treatment is a radiation therapy delivery technique for fixed-gantry (nonrotational) treatments on a helical tomotherapy system. The intensity-modulated fields are created by moving the treatment couch relative to a fan-beam positioned at fixed gantry angles. The delivered dose distribution is controlled b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2216876

    authors: Desai D,Ramsey CR,Breinig M,Mahan SL

    更新日期:2006-08-01 00:00:00

  • Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy.

    abstract:PURPOSE:Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754799

    authors: Fogliata A,Garcia R,Knoos T,Nicolini G,Clivio A,Vanetti E,Khamphan C,Cozzi L

    更新日期:2012-10-01 00:00:00

  • Automatic detection of simulated motion blur in mammograms.

    abstract:PURPOSE:To use machine-learning algorithms and blur measure (BM) operators to automatically detect motion blur in mammograms. Motion blur has been reported to reduce lesion detection performance and mask small abnormalities, resulting in failure to detect them until they reach more advanced stages. Automatic detection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14069

    authors: Kamona N,Loew M

    更新日期:2020-04-01 00:00:00

  • On the suitability of ultrathin detectors for absorbed dose assessment in the presence of high-density heterogeneities.

    abstract:PURPOSE:The aim of this study was to evaluate the suitability of several detectors for the determination of absorbed dose in bone. METHODS:Three types of ultrathin LiF-based thermoluminescent dosimeters (TLDs)-two LiF:Mg,Cu,P-based (MCP-Ns and TLD-2000F) and a (7)Li-enriched LiF:Mg,Ti-based (MTS-7s)-as well as EBT2 Ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4886760

    authors: Bueno M,Carrasco P,Jornet N,Muñoz-Montplet C,Duch MA

    更新日期:2014-08-01 00:00:00

  • Structure and adaptation of arteries to pulsatile flow: the case of the ascending aorta.

    abstract:PURPOSE:The objectives are: (i) assess the development of the impedance of some arteries during the first decades of life; (ii) determine the influence of pulse rate in arterial impedance; (iii) compare the structure of some arterial segments with optimized structures with respect to blood flow; and (iv) explain the el...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876379

    authors: Silva C,Reis AH

    更新日期:2014-06-01 00:00:00

  • Detection nonuniformity measurements and corrections for cone beam transmission CT on a gamma camera.

    abstract::Cone beam transmission CT (CB-CT) improves SPECT imaging by providing high-quality attenuation maps for attenuation compensation and for correlated SPECT and CT imaging. The present work measures the detection nonuniformity for CB-CT implemented with a gamma camera, and applies nonuniformity corrections to make CB-CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596838

    authors: Manglos SH,Capone RB,Bassano DA

    更新日期:1992-03-01 00:00:00