Abstract:
:Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved tumor delineation, and to assess the tumor response in follow-up investigations after or even during the course of fractionated therapy. Moreover, active research is being pursued on new tracers capable of providing different insights into tumor function, in order to identify areas of the planning volume which may require additional dosage for improved probability of tumor control. In this respect, major progresses in the next years will likely concern the development and clinical investigation of novel tracers and image processing techniques for reliable thresholding and segmentation, of treatment planning and beam delivery approaches integrating the PET imaging information, as well as improved multimodal clinical instrumentation such as PET/MR. But especially in the rapidly emerging case of ion beam therapy, the usage of PET is not only limited to the imaging of external tracers injected to the patient. In fact, a minor amount of positron emitters is formed in nuclear fragmentation reactions between the impinging ions and the tissue, bearing useful information for confirmation of the delivered treatment during or after therapeutic irradiation. Different implementations of unconventional PET imaging for therapy monitoring are currently being investigated clinically, and major ongoing research aims at new dedicated detector technologies and at challenging applications such as real-time imaging and time-resolved in vivo verification of motion compensated beam delivery. This paper provides an overview of the different areas of application of PET in radiation oncology and discusses the most promising perspectives in the years to come for radiation therapy planning, delivery, and monitoring.
journal_name
Med Physjournal_title
Medical physicsauthors
Parodi Kdoi
10.1118/1.4935869subject
Has Abstractpub_date
2015-12-01 00:00:00pages
7153-68issue
12eissn
0094-2405issn
2473-4209journal_volume
42pub_type
杂志文章,评审相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To demonstrate, via Monte Carlo simulation, that an image obtained from the patient-generated scattered radiation forced to impinge on the detector from a known direction by means of parallel-focused grids, can be used to complement the information conveyed by the primary image, such that accurate stereoscopic ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12712
更新日期:2018-02-01 00:00:00
abstract::The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2188816
更新日期:2006-05-01 00:00:00
abstract:PURPOSE:To design and quantify the shielding efficacy of an inner Borated Polyethylene (BPE)wall for a 15 MV linac in a low energy vault. METHODS:A Varian TrueBeam linac with a maximum photon energy of 15 MV was installed in asmaller, preexisting vault. This vault originally housed a low-energy machine and did not hav...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735334
更新日期:2012-06-01 00:00:00
abstract::Single-photon emission-computed tomography (SPECT) imaging of deep brain structures is compromised by loss of photons due to attenuation. We have previously shown that a centrally peaked collimator sensitivity function can compensate for this phenomenon, increasing sensitivity over most of the brain. For dual-head ins...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1929208
更新日期:2005-07-01 00:00:00
abstract::Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more ca...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3148536
更新日期:2009-07-01 00:00:00
abstract:PURPOSE:To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x-ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). METHODS:The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and dir...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12850
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4805102
更新日期:2013-06-01 00:00:00
abstract::A doorless entry system has been designed for use in high-energy radiation therapy rooms. The doorless entry improves patient access, safety and throughput, increases the physical safety for the radiation therapists, and avoids the significant cost of heavy shielding doors. The design meets concerns relating to radiat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598181
更新日期:1998-02-01 00:00:00
abstract::Luminance scatter fractions were measured for patients and phantoms in various regions of the chest film. Scatter fractions were found to be highly variable, being quite high in the regions of the chest with a large equivalent tissue thickness (e.g. mediastinum, chest wall, and subdiaphragmatic areas). For example, ap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595027
更新日期:1981-09-01 00:00:00
abstract:PURPOSE:In the nuclear medicine department, the activity of radiopharmaceuticals is measured using dose calibrators (DCs) prior to patient injection. The DC consists of an ionization chamber that measures current generated by ionizing radiation (emitted from the radiotracer). In order to obtain an activity reading, the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4966027
更新日期:2016-12-01 00:00:00
abstract::A single-field rotational total skin electron irradiation technique has recently been developed at the McGill University for treatment of skin malignancies. The dose received by a given surface point during rotation in a uniform large electron field depends on the radius of rotation of the surface point, on the local ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595524
更新日期:1984-07-01 00:00:00
abstract:PURPOSE:To develop a computer-driven and thus less user-dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS:In a first step, experimental measurements were performed for proton and carbon ion energies i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14647
更新日期:2020-12-07 00:00:00
abstract:PURPOSE:Treatments like radiotherapy and focused ultrasound in the abdomen require accurate motion tracking, in order to optimize dosage delivery to the target and minimize damage to critical structures and healthy tissues around the target. 4D ultrasound is a promising modality for motion tracking during such treatmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4890091
更新日期:2014-08-01 00:00:00
abstract::An automated data-acquisition and analysis system has been developed for dosimetry measurements on the pion therapy beam at the Clinton P. Anderson Meson Physics Facility Biomedical Channel in Los Alamos using a PDP-11/45 computer and CAMAC interface. Initialization, test, and monitor programs allow the user to set th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594418
更新日期:1978-03-01 00:00:00
abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594283
更新日期:1976-07-01 00:00:00
abstract:PURPOSE:The Alvarez-Macovski method extracts the x-ray energy-dependent information by expanding the attenuation coefficient as a linear combination of functions of energy multiplied by basis set coefficients. Since the basis functions are known a priori, the coefficients represent all the energy-dependent information....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13255
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:The Nakagami statistical model and Nakagami shape parameter m have been widely used in linear tissue characterization and preliminarily characterized the envelope distributions of nonlinear encapsulated microbubbles (EMBs). However, the Nakagami distribution of nonlinear scattering EMBs lacked a systematical in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13833
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:Radiotherapy, especially with charged particles, is sensitive to executional and preparational uncertainties that propagate to uncertainty in dose and plan quality indicators, for example, dose-volume histograms (DVHs). Current approaches to quantify and mitigate such uncertainties rely on explicitly computed e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14414
更新日期:2020-10-01 00:00:00
abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2919724
更新日期:2008-06-01 00:00:00
abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12558
更新日期:2017-11-01 00:00:00
abstract::New in vivo dosimetry methods would be useful for clinical HDR brachytherapy. An implantable MOSFET Dose Verification System designed by Sicel Technologies, Inc. was examined for use with 192Ir HDR applications. This investigation demonstrated that varying the dose rate from 22 to 84 cGy/min did not change detector re...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3013574
更新日期:2008-12-01 00:00:00
abstract::Deformable registration is needed for a variety of tasks in establishing the voxel correspondence between respiratory phases. Most registration algorithms assume or imply that the deformation field is smooth and continuous everywhere. However, the lungs are contained within closed invaginated sacs called pleurae and a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2828378
更新日期:2008-02-01 00:00:00
abstract::Flat-panel (FP) based digital radiography systems have recently been introduced as a new and improved digital radiography technology; it is important to evaluate and compare this new technology with currently widely used conventional screen/film (SF) and computed radiography (CR) techniques. In this study, the low-con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1408620
更新日期:2001-11-01 00:00:00
abstract:PURPOSE:Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These "cold" walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813302
更新日期:2013-08-01 00:00:00
abstract::A study of the objective imaging characteristics of a new asymmetric screen-film system is presented herein. The system is characterized by high x-ray absorption asymmetric screens, and a low-noise, high-contrast asymmetric film having near-zero crossover. Comparisons are made with the imaging characteristics of two w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597407
更新日期:1994-09-01 00:00:00
abstract:PURPOSE:The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4892174
更新日期:2014-09-01 00:00:00
abstract::Part III (oral exam) is the final part of ABR board exam for Diagnostic Medical Physics. In this exam, each of five oral examiners questions the candidate in each of five question categories. Oral exam has unique challenges to the candidate compared with the written exams. The candidate is expected to have not only ad...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736136
更新日期:2012-06-01 00:00:00
abstract::A system for measuring two-dimensional (2D) dose distributions in orthogonal anatomical planes in the cranium was developed and used to evaluate the accuracy of coplanar conformal therapy using ExacTrac image guidance. Dose distributions were measured in the axial, sagittal, and coronal planes using a CIRS (Computeriz...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2955751
更新日期:2008-08-01 00:00:00
abstract::Accurate dosimetry of small-field photon beams tends to be difficult to perform due to the presence of lateral electronic disequilibrium and steep dose gradients. In stereotactic radiosurgery (SRS), small fields of 6-30 mm in diameter are used. Generally thermoluminescence dosimetry chips, Farmer, Thimble ion chamber,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1350437
更新日期:2001-03-01 00:00:00
abstract:PURPOSE:The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox). METHODS:An antitumor drug Dox, an orthotopic animal prostate tumor model using human prostate cancer, LNCaP cell line, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4705346
更新日期:2012-05-01 00:00:00