Accuracy of cranial coplanar beam therapy using an oblique, stereoscopic x-ray image guidance system.

Abstract:

:A system for measuring two-dimensional (2D) dose distributions in orthogonal anatomical planes in the cranium was developed and used to evaluate the accuracy of coplanar conformal therapy using ExacTrac image guidance. Dose distributions were measured in the axial, sagittal, and coronal planes using a CIRS (Computerized Imaging Reference Systems, Inc.) anthropomorphic head phantom with a custom internal film cassette. Sections of radiographic Kodak EDR2 film were cut, processed, and digitized using custom templates. Spatial and dosimetric accuracy and precision of the film system were assessed. BrainScan planned a coplanar-beam treatment to conformally irradiate a 2-cm-diameter x 2-cm-long cylindrical planning target volume. Prior to delivery, phantom misalignments were imposed in combinations of +/- 8 mm offsets in each of the principal directions. ExacTrac x-ray correction was applied until the phantom was within an acceptance criteria of 1 mm/1 degrees (first two measurement sets) or 0.4 mm/0.4 degrees (last two measurement sets). Measured dose distributions from film were registered to the treatment plan dose calculations and compared. Alignment errors, displacement between midpoints of planned and measured 70% isodose contours (Deltac), and positional errors of the 80% isodose line were evaluated using 49 2D film measurements (98 profiles). Comparison of common, but independent measurements of Deltac showed that systematic errors in the measurement technique were 0.2 mm or less along all three anatomical axes and that random error averaged [formula: see text] 0.29+/-0.06 mm for the acceptance criteria of 1 mm/1 degrees and 0.15 +/- 0.02 mm for the acceptance criteria of 0.4 mm/0.4 degrees. The latter was consistent with independent estimates that showed the precision of the measurement system was 0.3 mm (2sigma). Values of Deltac were as great as 0.9, 0.3, and 1.0 mm along the P-A, R-L, and I-S axes, respectively. Variations in Deltac along the P-A axis were correlated to misalignments between laser isocenter and radiation isocenter as documented by daily clinical Lutz tests. Based on results of comparisons of measured with calculated positions of the 80% dose lines along the major anatomical axes, a 1.25, 1.0, and 1.0 mm (0.75, 0.5, and 0.25 mm) gross tumor volume (GTV)-planning target volume (PTV) margin to account for delivery error would be appropriate for the P-A, R-L, and I-S axes, respectively, for an acceptance criteria of 1 mm/1 degrees (0.4 mm/0.4 degrees). It typically took 2 (3) ExacTrac x-ray image sets to achieve and verify acceptance criteria of 1 mm/1 degrees (0.4 mm/0.4 degrees). Our results demonstrated a measurement technique using a CIRS anthropomorphic head phantom with a modified film cassette, radiographic film (Kodak EDR2) with a custom film cutting template, and film dosimetry software has been developed and successfully applied to our clinic. It is recommended that a third party offer this service. Our goal of achieving accuracy of delivery of 1 mm or better in each of the three major anatomical axes was almost, but not quite achieved, not because of the accuracy of the image guidance system, but likely due to inaccuracy of laser isocenter and other systematic errors.

journal_name

Med Phys

journal_title

Medical physics

authors

Vinci JP,Hogstrom KR,Neck DW

doi

10.1118/1.2955751

subject

Has Abstract

pub_date

2008-08-01 00:00:00

pages

3809-19

issue

8

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • Tissue-mimicking gelatin-agar gels for use in magnetic resonance imaging phantoms.

    abstract::A new variety of tissue-mimicking materials for use in 1H nuclear magnetic resonance (NMR) phantoms has been developed and extensively tested, principally at 10 MHz and at room temperature. The materials can be formed with a broad range of T1's and T2's representative of soft tissues. They are mixtures of various perc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596219

    authors: Blechinger JC,Madsen EL,Frank GR

    更新日期:1988-07-01 00:00:00

  • Optimal shielding design for bunkers of compact cyclotrons used in the production of medical radionuclides.

    abstract:PURPOSE:There are several options to consider in the design of a vault that will house a cyclotron for radioisotopes production with regards to the door entrance. Alternatives are a direct-shielded door, a simple maze, or a double-legged maze. In this work, the impact of the neutron and photon doses at the vault entran...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3515458

    authors: Facure A,França WF

    更新日期:2010-12-01 00:00:00

  • Dosimetric characterization of radionuclides for systemic tumor therapy: influence of particle range, photon emission, and subcellular distribution.

    abstract::Various radionuclides have been proposed for systemic tumor therapy. However, in most dosimetric analysis of proposed radionuclides the charged particles are taken into consideration while the potential photons are ignored. The photons will cause undesirable irradiation of normal tissue, and increase the probability o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2229428

    authors: Uusijärvi H,Bernhardt P,Ericsson T,Forssell-Aronsson E

    更新日期:2006-09-01 00:00:00

  • Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device.

    abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4933200

    authors: Zarghami N,Jensen MD,Talluri S,Foster PJ,Chambers AF,Dick FA,Wong E

    更新日期:2015-11-01 00:00:00

  • Water-equivalent dosimeter array for small-field external beam radiotherapy.

    abstract::With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2719363

    authors: Archambault L,Beddar AS,Gingras L,Lacroix F,Roy R,Beaulieu L

    更新日期:2007-05-01 00:00:00

  • Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets.

    abstract:PURPOSE:The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4916686

    authors: Rodriguez M,Sempau J,Brualla L

    更新日期:2015-06-01 00:00:00

  • The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: a Monte Carlo study.

    abstract::The purpose of this study was to investigate the effect of z overscanning on eye lens dose and effective dose received by pediatric patients undergoing head CT examinations. A pediatric patient study was carried out to obtain the exposure parameters and data regarding the eye lens position with respect to imaged volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2207212

    authors: Tzedakis A,Perisinakis K,Raissaki M,Damilakis J

    更新日期:2006-07-01 00:00:00

  • Automatic learning-based beam angle selection for thoracic IMRT.

    abstract:PURPOSE:The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908000

    authors: Amit G,Purdie TG,Levinshtein A,Hope AJ,Lindsay P,Marshall A,Jaffray DA,Pekar V

    更新日期:2015-04-01 00:00:00

  • Development of an automated region of interest selection method for 3D surface monitoring of head motion.

    abstract:PURPOSE:To simplify the often complex and user-dependent manual region of interest (ROI) selection process for head motion monitoring, an automatic ROI selection method was developed. METHODS:The automatic ROI selection algorithm calculated the displacements and velocities of 3D surface points between a temporally cor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4711805

    authors: Kang HJ,Grelewicz Z,Wiersma RD

    更新日期:2012-06-01 00:00:00

  • Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom.

    abstract:PURPOSE:X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4863510

    authors: Ren L,Wu D,Li Y,Wang G,Wu X,Liu H

    更新日期:2014-03-01 00:00:00

  • Material elemental decomposition in dual and multi-energy CT via a sparsity-dictionary approach for proton stopping power ratio calculation.

    abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12796

    authors: Shen C,Li B,Chen L,Yang M,Lou Y,Jia X

    更新日期:2018-04-01 00:00:00

  • A four-alternative forced choice (4AFC) methodology for evaluating microcalcification detection in clinical full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) systems using an inkjet-printed anthropomorphic phantom.

    abstract:PURPOSE:The advent of three-dimensional breast imaging systems such as digital breast tomosynthesis (DBT) has great promise for improving the detection and diagnosis of breast cancer. With these new technologies comes an essential need for testing methods to assess the resultant image quality. Although randomized clini...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13629

    authors: Ikejimba LC,Salad J,Graff CG,Ghammraoui B,Cheng WC,Lo JY,Glick SJ

    更新日期:2019-09-01 00:00:00

  • Discrimination analysis of breast calcifications using x-ray dark-field radiography.

    abstract:BACKGROUND:X-ray dark-field radiography could enhance mammography by providing more information on imaged tissue and microcalcifications. The dark field signal is a measure of small angle scattering and can thus provide additional information on the imaged materials. This information can be useful for material distinct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14043

    authors: Rauch T,Rieger J,Pelzer G,Horn F,Erber R,Wunderle M,Emons J,Nabieva N,Fuhrich N,Michel T,Hartmann A,Fasching PA,Anton G

    更新日期:2020-04-01 00:00:00

  • Compensator quality control with an amorphous silicon EPID.

    abstract::The calibration and quality control of compensators is conventionally performed with an ion chamber in a water-equivalent phantom. In our center, the compensator factor and four off-axis fluence ratios are measured to verify the central axis beam modulation and orientation of the compensator. Here we report the invest...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1584040

    authors: Menon GV,Sloboda RS

    更新日期:2003-07-01 00:00:00

  • Development of a flexible optical fiber based high resolution integrated PET∕MRI system.

    abstract:PURPOSE:The simultaneous measurement of PET and magnetic resonance imaging (MRI) is an emerging field for molecular imaging research. Although optical fiber based PET∕MRI systems have advantages on less interference between PET and MRI, there is a drawback in reducing the scintillation light due to the fiber. To reduce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4757911

    authors: Yamamoto S,Watabe H,Kanai Y,Watabe T,Aoki M,Sugiyama E,Kato K,Hatazawa J

    更新日期:2012-11-01 00:00:00

  • A method for avoiding overlap of left and right lungs in shape model guided segmentation of lungs in CT volumes.

    abstract:PURPOSE:The automated correct segmentation of left and right lungs is a nontrivial problem, because the tissue layer between both lungs can be quite thin. In the case of lung segmentation with left and right lung models, overlapping segmentations can occur. In this paper, the authors address this issue and propose a so...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4894817

    authors: Gill G,Bauer C,Beichel RR

    更新日期:2014-10-01 00:00:00

  • A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

    abstract:PURPOSE:To introduce a pair of accelerated non-Cartesian acquisition principles that when combined, exploit the periodicity of k-space acquisition, and thereby enable acquisition of high-temporal cine Cardiac Magnetic Resonance (CMR). METHODS:The mathematical formulation of a noniterative, undersampled non-Cartesian c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12234

    authors: Kawaji K,Patel MB,Cantrell CG,Tanaka A,Marino M,Tamura S,Wang H,Wang Y,Carroll TJ,Ota T,Patel AR

    更新日期:2017-07-01 00:00:00

  • A new method to combine 3D reconstruction volumes for multiple parallel circular cone beam orbits.

    abstract:PURPOSE:This article presents a new reconstruction method for 3D imaging using a multiple 360 degrees circular orbit cone beam CT system, specifically a way to combine 3D volumes reconstructed with each orbit. The main goal is to improve the noise performance in the combined image while avoiding cone beam artifacts. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3484058

    authors: Baek J,Pelc NJ

    更新日期:2010-10-01 00:00:00

  • Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl.

    abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3036117

    authors: Arvanitis CD,Bohndiek SE,Blakesley J,Olivo A,Speller RD

    更新日期:2009-01-01 00:00:00

  • Inspection of visible components in urine based on deep learning.

    abstract:PURPOSE:Urinary particles are particularly important parameters in clinical urinalysis, especially for the diagnosis of nephropathy. Therefore, it is highly important to precisely detect urinary particles in the clinical setting. However, artificial microscopy is subjective and time consuming, and various previous dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14118

    authors: Li Q,Yu Z,Qi T,Zheng L,Qi S,He Z,Li S,Guan H

    更新日期:2020-07-01 00:00:00

  • Positional radiotherapy beam dosimetry using a laser heated thermoluminescent plate.

    abstract::A 4-W, laser-based system for the positional readout of thermoluminescent (TL) plates was utilized to obtain dose profiles for a 60Co radiotherapy beam. Experimentally obtained glow curves for LiF resulting from the rapid heating rates characteristic of laser heating agreed well with results predicted using a first-or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596580

    authors: Kearfott KJ,Grupen-Shemansky ME

    更新日期:1990-05-01 00:00:00

  • DCE-MRI defined subvolumes of a brain metastatic lesion by principle component analysis and fuzzy-c-means clustering for response assessment of radiation therapy.

    abstract:PURPOSE:To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. METHODS:Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation thera...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4842556

    authors: Farjam R,Tsien CI,Lawrence TS,Cao Y

    更新日期:2014-01-01 00:00:00

  • Automated bone segmentation from dental CBCT images using patch-based sparse representation and convex optimization.

    abstract:PURPOSE:Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4868455

    authors: Wang L,Chen KC,Gao Y,Shi F,Liao S,Li G,Shen SG,Yan J,Lee PK,Chow B,Liu NX,Xia JJ,Shen D

    更新日期:2014-04-01 00:00:00

  • A comparison of gantry-mounted x-ray-based real-time target tracking methods.

    abstract:PURPOSE:Most modern radiotherapy machines are built with a 2D kV imaging system. Combining this imaging system with a 2D-3D inference method would allow for a ready-made option for real-time 3D tumor tracking. This work investigates and compares the accuracy of four existing 2D-3D inference methods using both motion tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12765

    authors: Montanaro T,Nguyen DT,Keall PJ,Booth J,Caillet V,Eade T,Haddad C,Shieh CC

    更新日期:2018-03-01 00:00:00

  • Implementation of a three-dimensional compensation system based on computed tomography generated surface contours and tissue inhomogeneities.

    abstract::A computed tomography (CT) based system that compensates for patient surface contour and internal tissue inhomogeneity was implemented in our clinic. The compensators are fabricated with a mixture of tin granules and bee's wax. The tin/wax mixture was optimized for tin granule size and tin granule to wax ratio. The na...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597303

    authors: Jursinic PA,Podgorsak MB,Paliwal BR

    更新日期:1994-03-01 00:00:00

  • Impact of calibration methods for color medical displays on interpreting brain SPECT images.

    abstract:PURPOSE:Color images are visualized on medical monitors that are adjusted by a grayscale standard display function (GSDF) or γ2.2. Although the GSDF is visually displayed as a linear graded grayscale, it does not specify how color medical images should be presented. On the other hand, the usual gamma setting for color ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13532

    authors: Shibutani T,Onoguchi M,Yoneyama H,Nakajima K,Matsuo S,Bamba Y,Saito S

    更新日期:2019-06-01 00:00:00

  • Surface dose rate calibration of Sr-90 plane ophthalmic applicators.

    abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596702

    authors: Goetsch SJ,Sunderland KS

    更新日期:1991-03-01 00:00:00

  • Eddy current disruption: effect on nuclear magnetic resonance coil impedance and power loss.

    abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596336

    authors: Harpen MD

    更新日期:1989-09-01 00:00:00

  • An improved bolus configuration for commercial multielement ultrasound and microwave hyperthermia systems.

    abstract::A simple modification is presented for two commercially available hyperthermia applicators which dramatically improves the regulation and dynamic control of the temperature at the bolus/tissue interface. This alteration requires the addition of a variable speed pump, bubble trap, simple heat exchanger, and a few minor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597196

    authors: Diederich CJ,Stauffer PR,Bozzo D

    更新日期:1994-09-01 00:00:00

  • Clinical use of EBT model Gafchromic film in radiotherapy.

    abstract::The Gafchromic EBT was recently introduced in film dosimetry for external beam therapy (EBT). The high spatial resolution, weak energy dependence, and near-tissue equivalence of EBT films make them suitable for measurement of dose distributions in radiotherapy, especially intensity-modulated radiation therapy (IMRT). ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2362876

    authors: Fiandra C,Ricardi U,Ragona R,Anglesio S,Giglioli FR,Calamia E,Lucio F

    更新日期:2006-11-01 00:00:00