Discrimination analysis of breast calcifications using x-ray dark-field radiography.

Abstract:

BACKGROUND:X-ray dark-field radiography could enhance mammography by providing more information on imaged tissue and microcalcifications. The dark field signal is a measure of small angle scattering and can thus provide additional information on the imaged materials. This information can be useful for material distinction of calcifications and the diagnosis of breast cancer by classifying benign and malign association of these calcifications. METHODS:For this study, institutional review board approval was obtained. We present the evaluation of images acquired with interferometric grating-based x-ray imaging of 323 microcalcifications (166 malign and 157 benign associated) in freshly dissected breast tissue and compare the results to the information extracted in follow-up pathological evaluation. The number of imaged calcifications is sufficiently higher than in similar previous studies. Fourteen calcification properties were extracted from the digital images and used as predictors in three different models common in discrimination analysis namely a simple threshold model, a naive Bayes model and a linear regression model, which classify the calcifications as associated with a benign or suspicious finding. Three of these fourteen predictors have been newly defined in this work and are independent from the tissue background surrounding the microcalcifications. Using these predictors no background correction is needed, as in previous works in this field. The new predictors are the length of the first and second principle component of the absorption and dark-field data, as well as the angle between the first principle component and the dark-field axis. We called these predictors data length, data width, and data orientation. RESULTS:In fourfold cross-validation malignancy of the imaged tissue was predicted. Models that take only classical absorption predictors into account reached a sensitivity of 53.3% at a specificity of 81.1%. For a combination of predictors that also include dark field information, a sensitivity of 63.2% and specificity of 80.8% were obtained. The included dark field information consisted of the newly introduced parameters, data orientation and data width. CONCLUSIONS:While remaining at a similar specificity, the sensitivity, with which a trained model was able to distinguish malign from benign associated calcifications, was increased by 10% on including dark-field information. This suggests grating-based x-ray imaging as a promising clinical imaging method in the field of mammography.

journal_name

Med Phys

journal_title

Medical physics

authors

Rauch T,Rieger J,Pelzer G,Horn F,Erber R,Wunderle M,Emons J,Nabieva N,Fuhrich N,Michel T,Hartmann A,Fasching PA,Anton G

doi

10.1002/mp.14043

subject

Has Abstract

pub_date

2020-04-01 00:00:00

pages

1813-1826

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom.

    abstract:PURPOSE:X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4863510

    authors: Ren L,Wu D,Li Y,Wang G,Wu X,Liu H

    更新日期:2014-03-01 00:00:00

  • A study of effective attenuation coefficient for calculating tissue compensator thickness.

    abstract::Dose uniformity throughout the treatment volume is essential to precision radiation therapy. Tissue compensators are often used as a means to eliminate dose nonuniformity resulting from surface contour irregularities. This paper evaluates the accuracy of using an effective attenuation coefficient for calculating the t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596561

    authors: Bagne FR,Samsami N,Hoke SW,Bronn DG

    更新日期:1990-01-01 00:00:00

  • 2-Step IMAT and 2-Step IMRT: a geometrical approach.

    abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861161

    authors: Bratengeier K

    更新日期:2005-03-01 00:00:00

  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • A CdZnTe slot-scanned detector for digital mammography.

    abstract::A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1523932

    authors: Mainprize JG,Ford NL,Yin S,Gordon EE,Hamilton WJ,Tümer TO,Yaffe MJ

    更新日期:2002-12-01 00:00:00

  • In vivo cancer diagnosis with optical spectroscopy and acoustically induced blood stasis using a murine MCa35 model.

    abstract::Ultrasound-induced blood stasis has been observed for more than 30 years. Most of the literature has been focused on the health risks associated with this phenomenon and methods employed to prevent stasis from occurring during ultrasound imaging. To date, experimental observations have been either in vitro or invasive...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198196

    authors: Winey BA,Misic V,Liao L,Parker K,Fenton BM,Yu Y

    更新日期:2006-06-01 00:00:00

  • Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

    abstract:PURPOSE:To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x-ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). METHODS:The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and dir...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12850

    authors: Maslowski A,Wang A,Sun M,Wareing T,Davis I,Star-Lack J

    更新日期:2018-05-01 00:00:00

  • Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms.

    abstract:PURPOSE:Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. METHODS:The authors developed a computerized liver extraction scheme based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3395579

    authors: Suzuki K,Kohlbrenner R,Epstein ML,Obajuluwa AM,Xu J,Hori M

    更新日期:2010-05-01 00:00:00

  • The value of nodal information in predicting lung cancer relapse using 4DPET/4DCT.

    abstract:PURPOSE:There is evidence that computed tomography (CT) and positron emission tomography (PET) imaging metrics are prognostic and predictive in nonsmall cell lung cancer (NSCLC) treatment outcomes. However, few studies have explored the use of standardized uptake value (SUV)-based image features of nodal regions as pre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4926755

    authors: Li H,Becker N,Raman S,Chan TC,Bissonnette JP

    更新日期:2015-08-01 00:00:00

  • Characterizing the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations.

    abstract:PURPOSE:To characterize the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations. To assess the spatial resolution of proton/carbon radiographic imaging. METHODS:A phantom was specifically modeled with inserts composed of two materials with three different densities of bone and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4819816

    authors: Seco J,Oumano M,Depauw N,Dias MF,Teixeira RP,Spadea MF

    更新日期:2013-09-01 00:00:00

  • Measurement of dose distributions using film in therapeutic electron beams.

    abstract::The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596409

    authors: Shiu AS,Otte VA,Hogstrom KR

    更新日期:1989-11-01 00:00:00

  • Dental enamel as an in vivo radiation dosimeter.

    abstract::The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue whi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595768

    authors: Pass B,Aldrich JE

    更新日期:1985-05-01 00:00:00

  • Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry.

    abstract:PURPOSE:To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. METHODS:Twenty volumetric images of patient breasts were acquired with a dedicated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4737025

    authors: Sechopoulos I,Bliznakova K,Qin X,Fei B,Feng SS

    更新日期:2012-08-01 00:00:00

  • The thermal characteristics of different diodes on in vivo patient dosimetry.

    abstract::Diode sensitivity variations with temperature (SVWT) have been reported to vary from small negative values up to 0.6% per degrees C. Thus it is possible for diode calibration factors established at room temperature (approximately 20 degrees C) to yield errors in the range of -1% to +9% when diodes are placed on a pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1367862

    authors: Welsh KT,Reinstein LE

    更新日期:2001-05-01 00:00:00

  • A neural network approach for fast, automated quantification of DIR performance.

    abstract:PURPOSE:A critical step in adaptive radiotherapy (ART) workflow is deformably registering the simulation CT with the daily or weekly volumetric imaging. Quantifying the deformable image registration accuracy under these circumstances is a complex task due to the lack of known ground-truth landmark correspondences betwe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12321

    authors: Neylon J,Min Y,Low DA,Santhanam A

    更新日期:2017-08-01 00:00:00

  • Technical Note: Correction for the effect of breathing variations in CT pulmonary ventilation imaging.

    abstract:PURPOSE:The accuracy and precision of computed tomography (CT) pulmonary ventilation imaging with conventional CT scanners are limited by breathing variations. We propose a method to correct for the effect of breathing variations in CT ventilation imaging based on external respiratory signals acquired throughout a scan...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1002/mp.12634

    authors: Yamamoto T,Kabus S

    更新日期:2018-01-01 00:00:00

  • Maximum likelihood estimation of proton irradiated field and deposited dose distribution.

    abstract::In proton therapy, it is important to evaluate the field irradiated with protons and the deposited dose distribution in a patient's body. Positron emitters generated through fragmentation reactions of target nuclei can be used for this purpose. By detecting the annihilation gamma rays from the positron emitters, the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2712572

    authors: Inaniwa T,Kohno T,Yamagata F,Tomitani T,Sato S,Kanazawa M,Kanai T,Urakabe E

    更新日期:2007-05-01 00:00:00

  • Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations.

    abstract::Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S val...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3103401

    authors: Pacilio M,Lanconelli N,Lo MS,Betti M,Montani L,Torres AL,Coca PM

    更新日期:2009-05-01 00:00:00

  • Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.

    abstract::Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing nov...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4941014

    authors: Mehranian A,Arabi H,Zaidi H

    更新日期:2016-03-01 00:00:00

  • Reconstruction of electron spectra using singular component decomposition.

    abstract::Reconstruction of electron spectra of medical accelerators from measured depth dose distributions is an attractive tool for commissioning of a Monte Carlo treatment planning system. However, the reconstruction method is an inverse radiation transport problem which is poorly conditioned, in the sense it may become unst...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1461840

    authors: Chvetsov AV,Sandison GA

    更新日期:2002-04-01 00:00:00

  • Ultrasound contrast-detail analysis: a preliminary study in human observer performance.

    abstract::Results of a human observer performance study using a new ultrasound contrast-detail (CD) phantom are reported. The new phantom allows estimates of the fundamental statistical uncertainties involved in CD analysis. Results of these experiments show that observers generally considered to be "trained" require experience...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597147

    authors: Hall TJ,Insana MF,Soller NM,Harrison LA

    更新日期:1993-01-01 00:00:00

  • The role of humidity and other correction factors in the AAPM TG-21 dosimetry protocol.

    abstract::A detailed derivation is presented of the formulas required to determine Ngas and Dmed in the AAPM TG-21 dosimetry protocol. This protocol specifies how to determine the absorbed dose in an electron or photon beam when using exposure or absorbed dose calibrated ion chambers. It is shown that the expression given in TG...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596292

    authors: Rogers DW,Ross CK

    更新日期:1988-01-01 00:00:00

  • An optimization algorithm for 3D real-time lung tumor tracking during arc therapy using kV projection images.

    abstract:PURPOSE:To develop a real-time markerless 3D tumor tracking using kilovoltage (kV) cone-beam CT (CBCT) projection images during volumetric modulated arc therapy (VMAT) treatment of lung tumors. METHODS:The authors have developed a method to identify the position of lung tumors during VMAT treatment, where the current ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4821545

    authors: Zhuang L,Liang J,Yan D,Zhang T,Marina O,Ionascu D

    更新日期:2013-10-01 00:00:00

  • A novel approach to evaluate spatial resolution of MRI clinical images for optimization and standardization of breast screening protocols.

    abstract:PURPOSE:Stringent quality assurance is required in MRI breast screening to ensure that different scanners and imaging protocols reach similar diagnostic performance. The authors propose a methodology, based on power spectrum analysis (PSA), to evaluate spatial resolution in clinical images. To demonstrate this approach...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966704

    authors: Borri M,Scurr ED,Richardson C,Usher M,Leach MO,Schmidt MA

    更新日期:2016-12-01 00:00:00

  • Validation of reconstructed bremsstrahlung spectra between 6 MV and 25 MV from measured transmission data.

    abstract::We have previously investigated a method of high-energy x-ray spectral reconstruction from transmission data by direct resolution of a matrix system. This technique uses the spectral vectorial algebra formalism. The resolution has previously been tested on a 12 MV photon beam. To extend and to test the validity of the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597998

    authors: Francois P,Coste F,Bonnet J,Caselles O

    更新日期:1997-05-01 00:00:00

  • L-curve analysis of radiotherapy optimization problems.

    abstract::We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1949750

    authors: Chvetsov AV

    更新日期:2005-08-01 00:00:00

  • kQ factors for ionization chamber dosimetry in clinical proton beams.

    abstract::We discuss a formalism for clinical proton beam dosimetry based on the use of ionization chamber absorbed dose-to-water calibration and beam quality correction factors. A quantity kQ, the beam quality correction factor, is defined which corrects the absorbed dose-to-water calibration factor ND,w in a reference beam of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597768

    authors: Vatnitsky SM,Siebers JV,Miller DW

    更新日期:1996-01-01 00:00:00

  • Gamma dose measurement in a d(80) + Be neutron beam.

    abstract::The gamma-ray dose component of a d(80) + Be neutron beam was measured with a 6Li-shielded Geiger-Mueller counter in a tissue-equivalent liquid phantom. The proportion of gamma-ray dose to total dose increased from 0.07 near the surface to 0.09 at 25 cm depth. Due to thermal neutron sensitivity, the G-M count rate inc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594571

    authors: Harrison GH,Cox CR

    更新日期:1979-05-01 00:00:00

  • A method to compare supra-pubic ultrasound and CT images of the prostate: technique and early clinical results.

    abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1644515

    authors: Molloy JA,Srivastava S,Schneider BF

    更新日期:2004-03-01 00:00:00

  • The line spread function and modulation transfer function of a computed tomographic scanner.

    abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594283

    authors: Judy PF

    更新日期:1976-07-01 00:00:00