Technical Note: Correction for the effect of breathing variations in CT pulmonary ventilation imaging.

Abstract:

PURPOSE:The accuracy and precision of computed tomography (CT) pulmonary ventilation imaging with conventional CT scanners are limited by breathing variations. We propose a method to correct for the effect of breathing variations in CT ventilation imaging based on external respiratory signals acquired throughout a scan. METHODS:The proposed method is based on: (a) calculating voxel-by-voxel abdominal surface motion ranges using four-dimensional (4D) CT image datasets spatiotemporally correlated with external respiratory monitor data, and (b) applying the correction factor, which is defined as the ratio of the overall mean of the abdominal surface motion range in the lungs to that of each voxel, to the CT ventilation value. The performance of the proposed method was investigated by comparing voxel-wise correlations of the uncorrected and corrected CT ventilation images with single-photon emission CT (SPECT) ventilation images as a ground truth for nine patients. CT ventilation images were calculated by deformable image registration of the 4D-CT image datasets, followed by calculation of regional volume changes. A Steiger's Z-test was used to determine the statistical significance of the difference between the correlations for the uncorrected and corrected CT ventilation images. RESULTS:The proposed correction method resulted in significant increases (P < 0.05) in the correlation between CT and SPECT ventilation in three patients, trends toward significant increase (P: 0.13-0.18) in two patients, no significant differences in three patients, and a significantly decreased correlation in one patient. The average standard deviation of the abdominal surface motion range in three patients showing significant increases was 0.27 (range 0.10-0.37), which was greater than 0.17 (range 0.07-0.38) in the other six patients. CONCLUSIONS:The proposed method to correct for the effect of breathing variations could be readily implemented and has the potential to improve the accuracy of CT ventilation imaging as demonstrated in a nine-patient study.

journal_name

Med Phys

journal_title

Medical physics

authors

Yamamoto T,Kabus S

doi

10.1002/mp.12634

subject

Has Abstract

pub_date

2018-01-01 00:00:00

pages

322-327

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

临床试验,杂志文章
  • Comparison of secondary neutron dose in proton therapy resulting from the use of a tungsten alloy MLC or a brass collimator system.

    abstract:PURPOSE:To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. METHODS:Hydrogenous an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3656025

    authors: Diffenderfer ES,Ainsley CG,Kirk ML,McDonough JE,Maughan RL

    更新日期:2011-11-01 00:00:00

  • Influence of cold walls on PET image quantification and volume segmentation: a phantom study.

    abstract:PURPOSE:Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These "cold" walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813302

    authors: Berthon B,Marshall C,Edwards A,Evans M,Spezi E

    更新日期:2013-08-01 00:00:00

  • Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain.

    abstract::Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517048

    authors: Seppälä T,Auterinen I,Aschan C,Serén T,Benczik J,Snellman M,Huiskamp R,Ramadan UA,Kankaanranta L,Joensuu H,Savolainen S

    更新日期:2002-11-01 00:00:00

  • The prediction of breast cancer biopsy outcomes using two CAD approaches that both emphasize an intelligible decision process.

    abstract::Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, sever...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2786864

    authors: Elter M,Schulz-Wendtland R,Wittenberg T

    更新日期:2007-11-01 00:00:00

  • Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

    abstract::The physical characteristics of a clinical charge coupled device (CCD)-based imager (Senovision, GE Medical Systems, Milwaukee, WI) for small-field digital mammography have been investigated. The imager employs a MinR 2000 (Eastman Kodak Company, Rochester, NY) scintillator coupled by a 1:1 optical fiber to a front-il...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1286720

    authors: Vedantham S,Karellas A,Suryanarayanan S,Levis I,Sayag M,Kleehammer R,Heidsieck R,D'Orsi CJ

    更新日期:2000-08-01 00:00:00

  • An artificial neural network for estimating scatter exposures in portable chest radiography.

    abstract::An adaptive linear element (Adaline) was developed to estimate the two-dimensional scatter exposure distribution in digital portable chest radiographs (DPCXR). DPCXRs and quantitative scatter exposure measurements at 64 locations throughout the chest were acquired for ten radiographically normal patients. The Adaline ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596978

    authors: Lo JY,Floyd CE Jr,Baker JA,Ravin CE

    更新日期:1993-07-01 00:00:00

  • Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.

    abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13731

    authors: Niebler S,Schömer E,Tjaden H,Schwanecke U,Schulze R

    更新日期:2019-10-01 00:00:00

  • Direction modulated brachytherapy (DMBT) for treatment of cervical cancer: A planning study with 192 Ir, 60 Co, and 169 Yb HDR sources.

    abstract:PURPOSE:To evaluate plan quality of a novel MRI-compatible direction modulated brachytherapy (DMBT) tandem applicator using 192 Ir, 60 Co, and 169 Yb HDR brachytherapy sources, for various cervical cancer high-risk clinical target volumes (CTVHR ). MATERIALS AND METHODS:The novel DMBT tandem applicator has six periphe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12598

    authors: Safigholi H,Han DY,Mashouf S,Soliman A,Meigooni AS,Owrangi A,Song WY

    更新日期:2017-12-01 00:00:00

  • Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl.

    abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3036117

    authors: Arvanitis CD,Bohndiek SE,Blakesley J,Olivo A,Speller RD

    更新日期:2009-01-01 00:00:00

  • Sci-Sat AM(1): Imaging-04: Respiratory errors in cardiac PET/CT with manual alignment of the CT image.

    abstract::Respiratory motion can produce misregistration errors between CT and PET images in cardiac PET/CT imaging. The objective of this study was to determine if manual registration of a single-phase end-expiration CT scan to the PET image would eliminate respiratory-induced artifacts. Listmode data from 71 cardiac PET patie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965988

    authors: Wells RG

    更新日期:2008-07-01 00:00:00

  • Computer-aided detection of breast cancers using Haar-like features in automated 3D breast ultrasound.

    abstract:PURPOSE:Automated 3D breast ultrasound (ABUS) has gained interest in breast imaging. Especially for screening women with dense breasts, ABUS appears to be beneficial. However, since the amount of data generated is large, the risk of oversight errors is substantial. Computer aided detection (CADe) may be used as a secon...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914162

    authors: Tan T,Mordang JJ,van Zelst J,Grivegnée A,Gubern-Mérida A,Melendez J,Mann RM,Zhang W,Platel B,Karssemeijer N

    更新日期:2015-04-01 00:00:00

  • Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery.

    abstract::The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response ne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1915017

    authors: Vedam S,Docef A,Fix M,Murphy M,Keall P

    更新日期:2005-06-01 00:00:00

  • Measured and calculated K-fluorescence effects on the MTF of an amorphous-selenium based CCD x-ray detector.

    abstract:PURPOSE:Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3673957

    authors: Hunter DM,Belev G,Kasap S,Yaffe MJ

    更新日期:2012-02-01 00:00:00

  • Onboard functional and molecular imaging: a design investigation for robotic multipinhole SPECT.

    abstract:PURPOSE:Onboard imaging-currently performed primarily by x-ray transmission modalities-is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single pho...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4845195

    authors: Bowsher J,Yan S,Roper J,Giles W,Yin FF

    更新日期:2014-01-01 00:00:00

  • Some possible effects of a catheter on the arterial wall.

    abstract::When a catheter is inserted through an artery, the wall shear stress increases and the secondary flow exhibits an increased number of instantaneous vortices. These effects become more evident when the annular gap between the catheter and the artery becomes more narrow. Accordingly it is suggested that these factors ma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596448

    authors: Karahalios GT

    更新日期:1990-09-01 00:00:00

  • Scatter rejection by electronic collimation.

    abstract::An electronic scanning-slit technology is under development which involves replacing paired fore and aft slits for scatter rejection with only one fore slit. As the slit scans across the portion of the patient to be imaged, pulsed x-ray exposures produce images of the slit in successive positions, which are digitized ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595940

    authors: Plenkovich D,Sorenson JA,Kruger RA

    更新日期:1986-03-01 00:00:00

  • Smoothing intensity-modulated treatment delivery under hardware constraints.

    abstract::A method is developed to smooth intensity-modulated beam delivery while considering hardware constraints. The method uses matrix algebra to model MLC leaf motion and hardware constraints such as interleaf digitization, synchronization requirements, and intersegment field abutment to deliver intensity modulated beam se...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1521121

    authors: Ma L

    更新日期:2002-12-01 00:00:00

  • Quantitative ionization chamber alignment to a water surface: Theory and simulation.

    abstract:PURPOSE:To examine the response properties of cylindrical cavity ionization chambers (ICs) in the depth-ionization buildup region so as to obtain a robust chamber-signal - based method for definitive water surface identification, hence absolute ionization chamber depth localization. METHOD & MATERIALS:An analytical mo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12319

    authors: Siebers JV,Ververs JD,Tessier F

    更新日期:2017-07-01 00:00:00

  • A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy.

    abstract:PURPOSE:To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. METHODS:Eleven patients with unresectable disease at the tonsil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928485

    authors: Yang J,Beadle BM,Garden AS,Schwartz DL,Aristophanous M

    更新日期:2015-09-01 00:00:00

  • Intensity modulated arc deliveries approximated by a large number of fixed gantry position sliding window dynamic multileaf collimator fields.

    abstract::The intensity modulated arc has been proposed as an alternative to tomotherapy. Treatment planing systems more typically model the conventional step and shoot or sliding window dynamic multileaf collimator (DMLC) deliveries, and may not support intensity modulated arc therapy (IMAT). As well, another potential drawbac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508110

    authors: MacKenzie MA,Robinson DM

    更新日期:2002-10-01 00:00:00

  • A dosimetry review system for cooperative group research.

    abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595221

    authors: Reinstein LE,McShan D,Glicksman AS

    更新日期:1982-03-01 00:00:00

  • Accuracy of EGSnrc calculations at 60Co energies for the response of ion chambers configured with various wall materials and cavity dimensions.

    abstract::In this investigation, five experimental data sets are used to evaluate the ability of the EGSnrc Monte Carlo code to calculate the change in chamber response associated with changes in wall material and cavity dimension at 60Co energies. Calculations of the ratios of response per unit mass of air as a function of cav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3013701

    authors: La Russa DJ,Rogers DW

    更新日期:2008-12-01 00:00:00

  • Comparison of quantitative Y-90 SPECT and non-time-of-flight PET imaging in post-therapy radioembolization of liver cancer.

    abstract:PURPOSE:Radioembolization with yttrium-90 microspheres may be optimized with patient-specific pretherapy treatment planning. Dose verification and validation of treatment planning methods require quantitative imaging of the post-therapy distribution of yttrium-90 (Y-90). Methods for quantitative imaging of Y-90 using b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962472

    authors: Yue J,Mauxion T,Reyes DK,Lodge MA,Hobbs RF,Rong X,Dong Y,Herman JM,Wahl RL,Geschwind JH,Frey EC

    更新日期:2016-10-01 00:00:00

  • Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners.

    abstract:PURPOSE:Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3426000

    authors: Mathieu KB,McNitt-Gray MF,Zhang D,Kim HJ,Cody DD

    更新日期:2010-08-01 00:00:00

  • Speckle contrast diffuse correlation tomography of complex turbid medium flow.

    abstract:PURPOSE:Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922206

    authors: Huang C,Irwin D,Lin Y,Shang Y,He L,Kong W,Luo J,Yu G

    更新日期:2015-07-01 00:00:00

  • Use of capillary optics as a beam intensifier for a Compton x-ray source.

    abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597218

    authors: Tompkins PA,Abreu CC,Carroll FE,Xiao QF,MacDonald CA

    更新日期:1994-11-01 00:00:00

  • Creating optimal code for GPU-accelerated CT reconstruction using ant colony optimization.

    abstract:PURPOSE:CT reconstruction algorithms implemented on the GPU are highly sensitive to their implementation details and the hardware they run on. Fine-tuning an implementation for optimal performance can be a time consuming task and require many updates when the hardware changes. There are some techniques that do automati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773045

    authors: Papenhausen E,Zheng Z,Mueller K

    更新日期:2013-03-01 00:00:00

  • Dual cardiac and respiratory gated thoracic imaging via adaptive gantry velocity and projection rate modulation on a linear accelerator: A Proof-of-Concept Simulation Study.

    abstract:PURPOSE:Cardiac motion is typically not accounted for during pretreatment imaging for central lung and mediastinal tumors. However, cardiac induced tumor motion averages 5.8 mm for esophageal tumors and 3-5 mm for some lung tumors, which can result in positioning errors. Our aim is to reduce both cardiac- and respirato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13670

    authors: Reynolds T,Shieh CC,Keall PJ,O'Brien RT

    更新日期:2019-09-01 00:00:00

  • Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data.

    abstract:PURPOSE:The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794488

    authors: Park MA,Moore SC,Müller SP,McQuaid SJ,Kijewski MF

    更新日期:2013-04-01 00:00:00

  • Quasi real time in vivo dosimetry for VMAT.

    abstract:PURPOSE:Results about the feasibility of a method for quasi real time in vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based on correlations between the EPID signal and the dose on the beam central axis. Moreover, the γ-analysis of EPID images w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4875685

    authors: Fidanzio A,Porcelli A,Azario L,Greco F,Cilla S,Grusio M,Balducci M,Valentini V,Piermattei A

    更新日期:2014-06-01 00:00:00