Abstract:
:The intensity modulated arc has been proposed as an alternative to tomotherapy. Treatment planing systems more typically model the conventional step and shoot or sliding window dynamic multileaf collimator (DMLC) deliveries, and may not support intensity modulated arc therapy (IMAT). As well, another potential drawback to this technique is that increasing the number of intensity levels required to achieve certain dose distributions necessitates increasing the number of gantry passes, as may occur if the desired dose distribution is complex (e.g., concave or bifurcated), potentially increasing the overall treatment time. A technique is presented here for the delivery of tomotherapy like dose distributions in a single gantry pass by the use of a large number of fields modulated by a sliding window DMLC technique from fixed equally spaced gantry positions. This serves as a good approximation to either IMAT or tomotherapy deliveries. The planning of these fields is achieved using iterative filtered back projection. Measured results of deliveries of varying degrees of complexity on a homogeneous phantom are compared to desired distributions.
journal_name
Med Physjournal_title
Medical physicsauthors
MacKenzie MA,Robinson DMdoi
10.1118/1.1508110subject
Has Abstractpub_date
2002-10-01 00:00:00pages
2359-65issue
10eissn
0094-2405issn
2473-4209journal_volume
29pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::A comparison of two methods of scatter compensation in single photon emission computed tomography (SPECT) imaging is made on the basis of improvements in quantification. The methods, scatter-window subtraction and constrained deconvolution of an average point source response function (PSRF), are described; the theoret...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596453
更新日期:1990-11-01 00:00:00
abstract:PURPOSE:One technical barrier to patient-specific computed tomography (CT) dosimetry has been the lack of computational tools for the automatic patient-specific multi-organ segmentation of CT images and rapid organ dose quantification. When previous CT images are available for the same body region of the patient, the a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14131
更新日期:2020-06-01 00:00:00
abstract:PURPOSE:Modulated electron radiation therapy (MERT) can offer significant advantages for breast treatments over conventional radiotherapy in terms of sparing distal critical structures. While intensity modulated radiation therapy (IMRT) has the advantage of achieving better dose homogeneity inside the target combining ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735665
更新日期:2012-06-01 00:00:00
abstract::A modified neutron production target assembly has been developed to provide improved performance of the proton-cyclotron-based neutron radiotherapy facility at the University of Washington for applications involving neutron capture enhanced fast-neutron therapy. The new target produces a neutron beam that yields essen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598839
更新日期:2000-02-01 00:00:00
abstract:PURPOSE:The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. METHODS:The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4918321
更新日期:2015-05-01 00:00:00
abstract::A method for optimizing MR imaging pulse sequence parameters in a statistical framework is presented. Parameters are defined to be optimal when the resulting scalar images yield optimal image segmentations using Bayesian pixel classification. Thus, Bayes risk is used as the objective function to minimize. Approximatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597425
更新日期:1995-10-01 00:00:00
abstract:PURPOSE:To accurately and efficiently implement charged particle transport in a magnetic field in EGSnrc and validate the code for the use in phantom and ion chamber simulations. METHODS:The effect of the magnetic field on the particle motion and position is determined using one- and three-point numerical integrations...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4954318
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:One of the promising options for motion management in radiation therapy (RT) is the use of LINAC-compatible robotic-arm-mounted ultrasound imaging system due to its high soft tissue contrast, real-time capability, absence of ionizing radiation, and low cost. The purpose of this work is to develop a novel deep l...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13510
更新日期:2019-05-01 00:00:00
abstract::Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wal...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1796171
更新日期:2004-10-01 00:00:00
abstract:PURPOSE:Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4918581
更新日期:2015-05-01 00:00:00
abstract::Interstitial brachytherapy for carcinoma of the prostate is achieved through the use of a configuration of radioactive seeds placed in a manner that delivers a customized, reasonably uniform dose to the target volume. Accurate dose delivery depends on both precise seed placement and reliable seed strength in the impla...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598877
更新日期:2000-01-01 00:00:00
abstract:PURPOSE:The Acuros XB (AXB) Advanced Dose algorithm (Varian Medical Systems) represents a dramatic shift in clinical photon dose calculation methodology from pencil-beam superposition/convolution methods. Early studies evaluating the accuracy of the algorithm in lung have found good agreement with both measurement and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735574
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To investigate energy deposition in glandular tissues of the breast on macro- and microscopic length scales in the context of mammography. METHODS:Multiscale mammography models of breasts are developed, which include segmented, voxelized macroscopic tissue structure as well as nine regions of interest (ROIs) e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13372
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the suitability of several detectors for the determination of absorbed dose in bone. METHODS:Three types of ultrathin LiF-based thermoluminescent dosimeters (TLDs)-two LiF:Mg,Cu,P-based (MCP-Ns and TLD-2000F) and a (7)Li-enriched LiF:Mg,Ti-based (MTS-7s)-as well as EBT2 Ga...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4886760
更新日期:2014-08-01 00:00:00
abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594463
更新日期:1978-01-01 00:00:00
abstract:PURPOSE:The authors investigated the potential of optimized noncoplanar irradiation trajectories for volumetric modulated arc therapy (VMAT) treatments of nasopharyngeal patients and studied the trade-off between treatment plan quality and delivery time in radiation therapy. METHODS:For three nasopharyngeal patients, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4914863
更新日期:2015-05-01 00:00:00
abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965910
更新日期:2008-07-01 00:00:00
abstract::Noise, partial volume (PV) effect, and image-intensity inhomogeneity render a challenging task for segmentation of brain magnetic resonance (MR) images. Most of the current MR image segmentation methods focus on only one or two of the above-mentioned effects. The objective of this paper is to propose a unified framewo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1944912
更新日期:2005-07-01 00:00:00
abstract::Accurately assessing the quality of prostate brachytherapy intraoperatively would be valuable for improved clinical outcome by ensuring the delivery of a prescribed tumoricidal radiation dose to the entire prostate gland. One necessary step towards this goal is the robust and rapid localization of implanted seeds. Sev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1624755
更新日期:2003-12-01 00:00:00
abstract:PURPOSE:CT reconstruction algorithms implemented on the GPU are highly sensitive to their implementation details and the hardware they run on. Fine-tuning an implementation for optimal performance can be a time consuming task and require many updates when the hardware changes. There are some techniques that do automati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773045
更新日期:2013-03-01 00:00:00
abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2776255
更新日期:2007-10-01 00:00:00
abstract::The hybrid algorithms developed recently for the reconstruction of fan-beam images possess computational and noise properties superior to those of the fan-beam filtered backprojection (FFBP) algorithm. However, the hybrid algorithms cannot be applied directly to a halfscan fan-beam sinogram because they require knowle...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1288239
更新日期:2000-09-01 00:00:00
abstract::Various radionuclides have been proposed for systemic tumor therapy. However, in most dosimetric analysis of proposed radionuclides the charged particles are taken into consideration while the potential photons are ignored. The photons will cause undesirable irradiation of normal tissue, and increase the probability o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2229428
更新日期:2006-09-01 00:00:00
abstract::The purpose of this work is to demonstrate a proof of feasibility of the application of a commercial prototype deformable model algorithm to the problem of delineation of anatomic structures on four-dimensional (4D) computed tomography (CT) image data sets. We acquired a 4D CT image data set of a patient's thorax that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1929207
更新日期:2005-07-01 00:00:00
abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594960
更新日期:1981-05-01 00:00:00
abstract:PURPOSE:The limited-angle intrafractional verification (LIVE) system was developed to track tumor movement during stereotactic body radiation therapy (SBRT). However, the four-dimensional (4D) MV/kV imaging procedure results in additional radiation dose to patients. This study is to quantify imaging radiation dose from...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13511
更新日期:2019-06-01 00:00:00
abstract::Total body photon irradiation (TBI) may be delivered with a number of standard techniques, typically using extended SSD geometries to obtain large field sizes. Since 1982 we have treated over 620 patients (adult and pediatric) mostly in the floor-located prone/supine treatment position with AP/PA beams using a column ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740139
更新日期:2012-07-01 00:00:00
abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2426404
更新日期:2007-02-01 00:00:00
abstract::We have developed two prototypes of portable gamma cameras for medical applications based on a previous prototype designed and tested by our group. These cameras use a CsI(Na) continuous scintillation crystal coupled to the new flat-panel-type multianode position-sensitive photomultiplier tube, H8500 from Hamamatsu Ph...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2358199
更新日期:2006-11-01 00:00:00
abstract::An important aspect of heavy charged particle radiotherapy is its ability to localize dose to the target volume. Current techniques generally employ beam delivery schemes which use range modulated beams in which the Bragg peak is spread out over a range of depths. The range modulation is constant over the entire beam ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595419
更新日期:1983-11-01 00:00:00