Performance tests of two portable mini gamma cameras for medical applications.

Abstract:

:We have developed two prototypes of portable gamma cameras for medical applications based on a previous prototype designed and tested by our group. These cameras use a CsI(Na) continuous scintillation crystal coupled to the new flat-panel-type multianode position-sensitive photomultiplier tube, H8500 from Hamamatsu Photonics. One of the prototypes, mainly intended for intrasurgical use, has a field of view of 44 x 44 mm2, and weighs 1.2 kg. Its intrinsic resolution is better than 1.5 mm and its energy resolution is about 13% at 140 keV. The second prototype, mainly intended for osteological, renal, mammary, and endocrine (thyroid, parathyroid, and suprarenal) scintigraphies, weighs a total of 2 kg. Its average spatial resolution is 2 mm; it has a field of view of 95 x 95 mm2, with an energy resolution of about 15% at 140 keV. The main advantages of these gamma camera prototypes with respect to those previously reported in the literature are high portability and low weight, with no significant loss of sensitivity and spatial resolution. All the electronic components are packed inside the mini gamma cameras, and no external electronic devices are required. The cameras are only connected through the universal serial bus port to a portable PC. In this paper, we present the design of the cameras and describe the procedures that have led us to choose their configuration together with the most important performance features of the cameras. For one of the prototypes, clinical tests on melanoma patients are presented and images are compared with those obtained with a conventional camera.

journal_name

Med Phys

journal_title

Medical physics

authors

Sánchez F,Fernández MM,Giménez M,Benlloch JM,Rodríguez-Alvarez MJ,García de Quirós F,Lerche Ch,Pavón N,Palazón JA,Martínez J,Sebastiá A

doi

10.1118/1.2358199

subject

Has Abstract

pub_date

2006-11-01 00:00:00

pages

4210-20

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

33

pub_type

杂志文章
  • Delivery validation of an automated modulated electron radiotherapy plan.

    abstract:PURPOSE:Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876297

    authors: Connell T,Alexander A,Papaconstadopoulos P,Serban M,Devic S,Seuntjens J

    更新日期:2014-06-01 00:00:00

  • Dose rate and SDD dependence of commercially available diode detectors.

    abstract::The dose-rate dependence of commercially available diode detectors was measured under both high instantaneous dose-rate (pulsed) and low dose rate (continuous, Co-60) radiation. The dose-rate dependence was measured in an acrylic miniphantom at a 5-cm depth in a 10 x 10 cm2 collimator setting, by varying source-to-det...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1650563

    authors: Saini AS,Zhu TC

    更新日期:2004-04-01 00:00:00

  • Determination of the photon spectrum of a clinical accelerator.

    abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595582

    authors: Brownridge J,Samnick S,Stiles P,Tipton P,Veselka J,Yeh N

    更新日期:1984-11-01 00:00:00

  • Ytterbium-169: calculated physical properties of a new radiation source for brachytherapy.

    abstract::Seeds containing radioactive Ytterbium-169 (169Yb) have recently been manufactured for possible application to brachytherapy. Ytterbium-169 emits photons with an average energy of 93 keV (excluding energies less than 10 keV), and decays with a half-life of 32 days. Analytic and Monte Carlo computations have been used ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596813

    authors: Mason DL,Battista JJ,Barnett RB,Porter AT

    更新日期:1992-05-01 00:00:00

  • SU-E-T-228: The Beauty and the Beast: Transition from Film/paper Charts to Paperless Environment with a New TrueBeam/ARIA System in a Small Community Hospital on a Tight Budget.

    abstract:PURPOSE:To review the issues a physicist may encounter in a community hospital during the transition from film/paper charts to a paperless environment with ARIA and a TrueBeam LINAC. With a lean budget, it was necessary for the physics group to take on the project management responsibilities in order save costs. This w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735291

    authors: Chu K,Rasmussen B

    更新日期:2012-06-01 00:00:00

  • Predicting the noise in hybrid (phase and attenuation) x-ray images acquired with the edge illumination technique.

    abstract:PURPOSE:To analyze the noise performance of the edge illumination phase-based x-ray imaging technique when applying "single-shot" phase retrieval. The latter consists in applying a sample-specific low-pass filter to the raw data, leading to "hybrid" images in which phase and attenuation contrast are merged with each ot...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14366

    authors: Hagen CK,Roche I Morgó O,Olivo A

    更新日期:2020-09-01 00:00:00

  • Multiattribute probabilistic prostate elastic registration (MAPPER): application to fusion of ultrasound and magnetic resonance imaging.

    abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905104

    authors: Sparks R,Bloch BN,Feleppa E,Barratt D,Moses D,Ponsky L,Madabhushi A

    更新日期:2015-03-01 00:00:00

  • COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs.

    abstract::Monte Carlo (MC) simulations were performed to estimate brachytherapy dose distributions for Collaborative Ocular Melanoma Study (COMS) eye plaques. Brachytherapy seed models 200, 6711, and CS-1 Rev2 carrying 103Pd, 125I, and 131Cs radionuclides, respectively, were modeled and benchmarked against previously published ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2940604

    authors: Melhus CS,Rivard MJ

    更新日期:2008-07-01 00:00:00

  • Potential use of P-32 ophthalmic applicator: Monte Carlo simulations for design and dosimetry.

    abstract::Postoperative beta-irradiation after pterygium excision has been considered a valuable therapeutic procedure to reduce the recurrence rate. Recently, it was reported that beta-irradiation also substantially reduced the risk of surgical failure after glaucoma surgery. Pure beta-irradiation using a 90Sr/Y applicator has...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2896076

    authors: Park YK,Ye SJ,Kim IH,Wee WR,Kim MK,Han HS,Son KJ,Park UJ

    更新日期:2008-05-01 00:00:00

  • L-curve analysis of radiotherapy optimization problems.

    abstract::We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1949750

    authors: Chvetsov AV

    更新日期:2005-08-01 00:00:00

  • 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification.

    abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2936229

    authors: Stancanello J,Muacevic A,Sebastiano F,Modugno N,Cerveri P,Ferrigno G,Uggeri F,Romanelli P

    更新日期:2008-07-01 00:00:00

  • A framework for quantification and visualization of segmentation accuracy and variability in 3D lateral ventricle ultrasound images of preterm neonates.

    abstract:PURPOSE:Intraventricular hemorrhage (IVH) is a major cause of brain injury in preterm neonates. Three dimensional ultrasound (US) imaging systems have been developed to visualize 3D anatomical structure of preterm neonatal intracranial ventricular system with IVH and ventricular dilation. To allow quantitative analysis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932366

    authors: Chen Y,Qiu W,Kishimoto J,Gao Y,Chan RH,de Ribaupierre S,Fenster A,Chiu B

    更新日期:2015-11-01 00:00:00

  • Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms.

    abstract::Automatic exposure control (AEC) systems have been developed by computed tomography (CT) manufacturers to improve the consistency of image quality among patients and to control the absorbed dose. Since a multichannel helical CT scan may easily increase individual radiation doses, this technical improvement is of speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2746492

    authors: Brisse HJ,Madec L,Gaboriaud G,Lemoine T,Savignoni A,Neuenschwander S,Aubert B,Rosenwald JC

    更新日期:2007-07-01 00:00:00

  • Estimation of organ doses from kilovoltage cone-beam CT imaging used during radiotherapy patient position verification.

    abstract:PURPOSE:The purpose of this study was to develop a practical method for estimating organ doses from kilovoltage cone-beam CT (CBCT) that can be performed with readily available phantoms and dosimeters. The accuracy of organ dose estimates made using the ImPACT patient dose calculator was also evaluated. METHODS:A 100 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3476459

    authors: Hyer DE,Hintenlang DE

    更新日期:2010-09-01 00:00:00

  • Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

    abstract::The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric effects were studied considering the breathing pattern of three patients monitored during the course of their treatment ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2821704

    authors: Seco J,Sharp GC,Wu Z,Gierga D,Buettner F,Paganetti H

    更新日期:2008-01-01 00:00:00

  • Some possible effects of a catheter on the arterial wall.

    abstract::When a catheter is inserted through an artery, the wall shear stress increases and the secondary flow exhibits an increased number of instantaneous vortices. These effects become more evident when the annular gap between the catheter and the artery becomes more narrow. Accordingly it is suggested that these factors ma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596448

    authors: Karahalios GT

    更新日期:1990-09-01 00:00:00

  • Scattered radiation in chest radiography.

    abstract::Luminance scatter fractions were measured for patients and phantoms in various regions of the chest film. Scatter fractions were found to be highly variable, being quite high in the regions of the chest with a large equivalent tissue thickness (e.g. mediastinum, chest wall, and subdiaphragmatic areas). For example, ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595027

    authors: Niklason LT,Sorenson JA,Nelson JA

    更新日期:1981-09-01 00:00:00

  • A dosimetry study of the Oncoseed 6711 using glass rod dosimeters and EGS5 Monte Carlo code in a geometry lacking radiation equilibrium scatter conditions.

    abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3590370

    authors: Tanaka K,Tateoka K,Asanuma O,Kamo K,Bengua G,Sato K,Ueda T,Takeda H,Takagi M,Hareyama M,Takada J

    更新日期:2011-06-01 00:00:00

  • Convolutional neural network-based pelvic floor structure segmentation using magnetic resonance imaging in pelvic organ prolapse.

    abstract:PURPOSE:Automated segmentation could improve the efficiency of modeling-based pelvic organ prolapse (POP) evaluations. However, segmentation performance is limited by the blurry soft tissue boundaries. In this study, we aimed to present a hybrid solution for uterus, rectum, bladder, and levator ani muscle segmentation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14377

    authors: Feng F,Ashton-Miller JA,DeLancey JOL,Luo J

    更新日期:2020-09-01 00:00:00

  • Laser heating of thermoluminescent plates: application to intraoperative radiotherapy.

    abstract::A new system of radiation dose mapping based on laser heating of thermoluminescent dosimetric plates (TLDP) has been developed. Application of this technique to intraoperative radiotherapy (IORT) has been investigated. Preliminary results show that TLDP are a possible alternative to radiological films and ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597725

    authors: Beteille D,Setzkom R,Prévost H,Dusseau L,Fesquet J,Gasiot J,Muraro S,Delard R,Dubois JB,Ailleres N,Missous O

    更新日期:1996-08-01 00:00:00

  • SU-E-T-16: Statistical Variability and Confidence Intervals for Planar Dose QA Pass Rates.

    abstract:PURPOSE:The most common metric for comparing measured to calculated dose planes is a pass rate generated using percent difference, distance-to-agreement (DTA), or some combination of the two (e.g. gamma evaluation). The grid of analyzed points often corresponds to a dosimeter array with low areal-density of point detec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735070

    authors: Bailey D,Nelms B,Kumaraswamy L,Attwood K,Podgorsak M

    更新日期:2012-06-01 00:00:00

  • Photon-beam subsource sensitivity to the initial electron-beam parameters.

    abstract::One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC sour...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1884385

    authors: Fix MK,Keall PJ,Siebers JV

    更新日期:2005-04-01 00:00:00

  • Experimental verification of a technique for predicting scattered radiation transfer: application to low photon energies.

    abstract::It is shown that predictions can be made of scatter-to-primary ratios for a variety of mammographic configurations. The different configurations can be produced by changes in source-detector distance; source-phantom distance; air gap; photon energy; phantom composition, thickness, and cross-sectional area. A detailed ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595807

    authors: Bernstein H,Muntz EP

    更新日期:1986-11-01 00:00:00

  • Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model.

    abstract::The widespread application of positron emission tomography (PET) in clinical oncology has driven this imaging technology into a number of new research and clinical arenas. Increasing numbers of patient scans have led to an urgent need for efficient data handling and the development of new image analysis techniques to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2432404

    authors: Montgomery DW,Amira A,Zaidi H

    更新日期:2007-02-01 00:00:00

  • SU-E-T-118: Characterization of EBT3 Films in Photon and Proton Beams.

    abstract:PURPOSE:To measure the calibration curves of EBT3 dosimetry films in photon and proton beams and to quantify the related uncertainties from one beam type to another. METHODS:EBT3 Gafchromic films have similar properties than EBT2 with a symmetric construction and a matte polyester substrate to prevent Newton's ring ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735176

    authors: Sorriaux J,Rossomme S,Kacperek A,Bertrand D,Vynckier S,Sterpin E

    更新日期:2012-06-01 00:00:00

  • Monte Carlo calculation of output factors for circular, rectangular, and square fields of electron accelerators (6-20 MeV).

    abstract::Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1373402

    authors: Verhaegen F,Mubata C,Pettingell J,Bidmead AM,Rosenberg I,Mockridge D,Nahum AE

    更新日期:2001-06-01 00:00:00

  • Analysis of generalized rosette trajectory for compressed sensing MRI.

    abstract:PURPOSE:The application of compressed sensing (CS) technology in magnetic resonance imaging (MRI) is to accelerate the MRI scan speed by incoherent undersampling of k-space data and nonlinear iterative reconstruction of MRI images. This paper generalizes the existing rosette trajectories to configure the sampling patte...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928152

    authors: Li Y,Yang R,Zhang C,Zhang J,Jia S,Zhou Z

    更新日期:2015-09-01 00:00:00

  • Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.

    abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812609

    authors: Niu H,Hsi WC,Chu JC,Kirk MC,Kouwenhoven E

    更新日期:2004-12-01 00:00:00

  • Astigmatic single photon emission computed tomography imaging with a displaced center of rotation.

    abstract::A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598325

    authors: Wang H,Smith MF,Stone CD,Jaszczak RJ

    更新日期:1998-08-01 00:00:00

  • The tracks of the Compton effect.

    abstract::The observation of scattered radiations of larger wavelength than the primary had been repeatedly rejected or explained away by many researchers, including Compton. After years of vacillations, he recognized the effect named after him and was the first to develop a quantal equation predicting the wavelength of scatter...

    journal_title:Medical physics

    pub_type: 传,历史文章,杂志文章

    doi:10.1118/1.595046

    authors: del Regato JA

    更新日期:1981-11-01 00:00:00