Abstract:
PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies between planned dose-volume histogram (DVH) and perturbed DVH. The perturbed DVH is calculated by using a dedicated software, 3DVH (Sun Nuclear Corporation, Melbourne, FL), which is able to modify the dose distribution calculated by the treatment planning system (TPS) according to the dose discrepancies detected with planar measurements in order to predict the delivered 3D dose distribution in the patient. METHODS:Twenty-seven high-risk prostate cancer (PP) patients and 15 head and neck (HN) cancer patients, treated with IMRT technique, were analyzed. Pretreatment verifications were performed for all patients' plans by acquiring planar dose distributions of each treatment field with 2D-diode array. Measured dose distributions were compared to the calculated ones using the gamma index (GI) method applying both global (Van Dyk) and local normalization, and %GP were generated for each pair of planar doses using the following acceptance criteria: 1%∕1, 2%∕2, and 3%∕3 mm. Planar dose distributions acquired during pretreatment verifications, together with patient's DICOM RT plan, RT structure set, and RT dose files from TPS were loaded into the 3DVH software. Percentage dose differences (%DE) between DVHs, obtained by TPS and by 3DVH, were calculated; statistical correlation between %DE and %GP was studied by using Pearson's correlation coefficient (r). This analysis was performed, for each patient, on planning target volumes and on some typical organs at risk of the prostatic and head and neck anatomical district. The sensitivity was calculated to correctly identify the pretreatment plans with high dose errors and to quantify the incidence of false negatives, on varying the gamma index method. RESULTS:Analysis of %DE vs %GP showed that there were only weak correlations (Pearson's r-values < 0.8). The results also showed numerous instances of false negatives (cases where high IMRT QA passing rates did not imply good agreement in anatomy dose metrics) and the reverse, mainly for the 3%∕3 mm global gamma passing rate. CONCLUSIONS:The lack of correlation between conventional IMRT QA performance metrics gamma passing rates and dose errors in DVHs values and the low sensitivity of 3%∕3 mm global gamma method show that the most common published acceptance criteria have disputable predictive power for per-patient IMRT QA.
journal_name
Med Physjournal_title
Medical physicsauthors
Stasi M,Bresciani S,Miranti A,Maggio A,Sapino V,Gabriele Pdoi
10.1118/1.4767763subject
Has Abstractpub_date
2012-12-01 00:00:00pages
7626-34issue
12eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Optical-resolution photoacoustic microscopy (OR-PAM) has been validated as a valuable tool for label-free volumetric microvascular imaging. More importantly, the advantages of noninvasiveness and measurement consistency suggest the use of OR-PAM for chronic imaging of intact microcirculation. Here, such chronic imagin...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3137572
更新日期:2009-06-01 00:00:00
abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735470
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Deformable registration generally relies on the assumption that the sought spatial transformation is smooth. Yet, breathing motion involves sliding of the lung with respect to the chest wall, causing a discontinuity in the motion field, and the smoothness assumption can lead to poor matching accuracy. In respon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3679009
更新日期:2012-02-01 00:00:00
abstract::A computer program was implemented to predict mammography x-ray beam parameters in the range 20-40 kV for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations. The computation method used to simulate mammography x-ray spectra is based on the Boone et al. model. The beam quality parameters such as the half-value la...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1608498
更新日期:2003-10-01 00:00:00
abstract::The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous sil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2147744
更新日期:2006-02-01 00:00:00
abstract::An automated technique has been developed for the verification of treatment field size and shape in external beam radiation therapy. Portal images from film or digital on-line imaging system are analyzed, and basic parameters are derived to describe the field size and shape from the contour points on the field boundar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597017
更新日期:1993-05-01 00:00:00
abstract:PURPOSE:There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4898325
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:The aim of this work was to provide a novel description of how the radiotherapy community configures treatment planning system (TPS) radiation beam models for clinically used treatment machines. Here we describe the results of a survey of self-reported TPS beam modeling parameter values across different C-arm l...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13892
更新日期:2020-01-01 00:00:00
abstract::In this article, we report on the development of a simple and accurate method for quality assurance of electron beam output and energy. Aluminum disks of thicknesses d(max) or d50 of the particular electron energy are positioned sequentially over a parallel-plate ion chamber and the ratio of the two signals is compare...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1688040
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:To determine the diagnostic efficacy of optical coherence tomography (OCT) to identify cervical intraepithelial neoplasia (CIN) grade 2 or higher by computer-aided diagnosis (CADx). METHODS:OCT has been investigated as a screening/diagnostic tool in the management of preinvasive and early invasive cancers of t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3523098
更新日期:2011-01-01 00:00:00
abstract::Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2775667
更新日期:2007-10-01 00:00:00
abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594447
更新日期:1978-11-01 00:00:00
abstract::The Anisotropic Analytical Algorithm (AAA) of the Varian Eclipse treatment planning system calculates absolute dose for a variety of beam settings including those with an enhanced dynamic wedge (EDW). This algorithm has gone through a number of version updates since it was first released in July 2005. Previous version...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965929
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:To evaluate the performance of a model based image reconstruction in reducing metal artifacts in MVCT systems, and to compare with filtered-back projection (FBP) technique. METHODS:Iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with pair/triplet production process and the energy d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734850
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3641874
更新日期:2011-11-01 00:00:00
abstract::Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1388219
更新日期:2001-08-01 00:00:00
abstract::New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applicat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2837288
更新日期:2008-03-01 00:00:00
abstract::Determination of the relaxation times T1 and T2 which are important for tissue characterization generally requires the use of different pulse sequences in magnetic resonance imaging. In this study, a new pulse sequence which facilitates simultaneous determination of the T1 and T2 times is presented. Determination take...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595867
更新日期:1986-09-01 00:00:00
abstract:PURPOSE:A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-spec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3556589
更新日期:2011-03-01 00:00:00
abstract::In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the pat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1589496
更新日期:2003-09-01 00:00:00
abstract:PURPOSE:There are several options to consider in the design of a vault that will house a cyclotron for radioisotopes production with regards to the door entrance. Alternatives are a direct-shielded door, a simple maze, or a double-legged maze. In this work, the impact of the neutron and photon doses at the vault entran...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3515458
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:In intensity-modulated proton therapy (IMPT), protons are used to deliver highly conformal dose distributions, targeting tumors, and sparing organs-at-risk. However, due to uncertainties in both patient setup and relative stopping power (RSP) calculation, margins are added to the treatment volume during treatme...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14347
更新日期:2020-09-01 00:00:00
abstract::We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2828184
更新日期:2008-02-01 00:00:00
abstract::A general expression is derived for the NMR signal from a fluid undergoing random directional flow such as encountered within the microcirculation. The dependence of the echo amplitude on flow velocity, sample morphology, and experimental parameters are described in terms of a temporal velocity autocorrelation functio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597170
更新日期:1994-04-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13731
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3310806
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:Because the small-radius photon beams shaped by cones in stereotactic radiosurgery (SRS) lack lateral electronic equilibrium and a detector's finite cross section, direct experimental measurement of dosimetric data for these beams can be subject to large uncertainties. As the dose calculation accuracy of a trea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3488900
更新日期:2010-10-01 00:00:00
abstract:PURPOSE:Secondary particles produced in the collision of protons with beam modifiers are of concern in proton therapy. Nevertheless, secondary radiation can provide information on the dosimetric parameters through its dependency on the modulating accessories (range shifter and range modulating wheel). Relatively little...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4765049
更新日期:2012-12-01 00:00:00
abstract::The goal of this study was to develop a technique to distinguish benign and malignant breast lesions in secondarily digitized mammograms. A set of 51 mammograms (two views/patient) containing lesions of known pathology were evaluated using six different morphological descriptors: circularity, mu R/sigma R (where mu R ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597707
更新日期:1996-08-01 00:00:00
abstract:PURPOSE:Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antib...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921997
更新日期:2015-07-01 00:00:00