Investigation of a breathing surrogate prediction algorithm for prospective pulmonary gating.

Abstract:

PURPOSE:A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-specified breathing phases. This study describes the development and testing of an autoregressive moving average (ARMA) model for human respiratory phase prediction under quiet respiration conditions. METHODS:A total of 47 4DCT patient datasets and synchronized respiration records was utilized in this study. Three datasets were used in model development and were removed from further evaluation of the ARMA model. The remaining 44 patient datasets were evaluated with the ARMA model for prediction time steps from 50 to 1000 ms in increments of 50 and 100 ms. Thirty-five of these datasets were further used to provide a comparison between the proposed ARMA model and a commercial algorithm with a prediction time step of 240 ms. RESULTS:The optimal number of parameters for the ARMA model was based on three datasets reserved for model development. Prediction error was found to increase as the prediction time step increased. The minimum prediction time step required for prospective gating was selected to be half of the gantry rotation period. The maximum prediction time step with a conservative 95% confidence criterion was found to be 0.3 s. The ARMA model predicted peak inhalation and peak exhalation phases significantly better than the commercial algorithm. Furthermore, the commercial algorithm had numerous instances of missed breath cycles and falsely predicted breath cycles, while the proposed model did not have these errors. CONCLUSIONS:An ARMA model has been successfully applied to predict human respiratory phase occurrence. For a typical CT scanner gantry rotation period of 0.4 s (0.2 s prediction time step), the absolute error was relatively small, 0.06 +/- 0.02 s at peak inhalation and 0.05 +/- 0.04 s at peak exhalation. The application of the ARMA model for prospective pulmonary gating has been demonstrated.

journal_name

Med Phys

journal_title

Medical physics

authors

White BM,Low DA,Zhao T,Wuenschel S,Lu W,Lamb JM,Mutic S,Bradley JD,El Naqa I

doi

10.1118/1.3556589

subject

Has Abstract

pub_date

2011-03-01 00:00:00

pages

1587-95

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

38

pub_type

杂志文章
  • Kilovoltage stereotactic radiosurgery for age-related macular degeneration: assessment of optic nerve dose and patient effective dose.

    abstract::Age-related macular degeneration (AMD) is a leading cause for vision loss for people over the age of 65 in the United States and a major health problem worldwide. Research for new treatments of the wet form of the disease using kilovoltage stereotactic radiosurgery is currently underway at Oraya Therapeutics, Inc. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3168554

    authors: Hanlon J,Lee C,Chell E,Gertner M,Hansen S,Howell RW,Bolch WE

    更新日期:2009-08-01 00:00:00

  • Conceptual design of beryllium targets for the generation of neutron beams for radiation therapy by the (p,n) reaction.

    abstract::A conceptual design is presented showing that, by judiciously choosing the beryllium target thickness and the backstop material, improvements can be achieved in dose-rate, skin sparing, and penetration of neutron beams generated by the same proton accelerator. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594748

    authors: Awschalom M,Rosenberg I

    更新日期:1980-09-01 00:00:00

  • Computer-assisted beam modeling for particle therapy.

    abstract:PURPOSE:To develop a computer-driven and thus less user-dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS:In a first step, experimental measurements were performed for proton and carbon ion energies i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14647

    authors: Fuchs H,Elia A,Resch AF,Kuess P,Lühr A,Vidal M,Grevillot L,Georg D

    更新日期:2020-12-07 00:00:00

  • SU-E-T-162: Rapid Assessment of Cyberknife IRIS Variable Collimator Performance Using a Commercial Diode Array.

    abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735220

    authors: Gibbs G,White G,Bulz G

    更新日期:2012-06-01 00:00:00

  • Low dose positron emission tomography emulation from decimated high statistics: A clinical validation study.

    abstract:PURPOSE:The fundamental nature of positron emission tomography (PET), as an event detection system, provides some flexibility for data handling, including retrospective data manipulation. The reorganization of acquisition data allows the emulation of new scans arising from identical radiotracer spatial distributions, b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13517

    authors: Schaefferkoetter J,Nai YH,Reilhac A,Townsend DW,Eriksson L,Conti M

    更新日期:2019-06-01 00:00:00

  • Application of spherical diodes for megavoltage photon beams dosimetry.

    abstract:PURPOSE:External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A hi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4837178

    authors: Barbés B,Azcona JD,Burguete J,Martí-Climent JM

    更新日期:2014-01-01 00:00:00

  • Study of the secondary neutral radiation in proton therapy: toward an indirect in vivo dosimetry.

    abstract:PURPOSE:Secondary particles produced in the collision of protons with beam modifiers are of concern in proton therapy. Nevertheless, secondary radiation can provide information on the dosimetric parameters through its dependency on the modulating accessories (range shifter and range modulating wheel). Relatively little...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4765049

    authors: Carnicer A,Letellier V,Rucka G,Angellier G,Sauerwein W,Herault J

    更新日期:2012-12-01 00:00:00

  • Automatic quantitative low contrast analysis of digital chest phantom radiographs.

    abstract::Up to the present, the majority of low contrast object evaluations performed on phantom images have been accomplished in a subjective fashion. This is mainly due to the time and effort required to manually measure each radiograph with a densitometer to obtain quantitative results. However, with the development of digi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543153

    authors: Kwan AL,Filipow LJ,Le LH

    更新日期:2003-03-01 00:00:00

  • An analysis of the mechanical parameters used for finite element compression of a high-resolution 3D breast phantom.

    abstract:PURPOSE:The authors previously introduced a methodology to generate a realistic three-dimensional (3D), high-resolution, computer-simulated breast phantom based on empirical data. One of the key components of such a phantom is that it provides a means to produce a realistic simulation of clinical breast compression. In...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3637500

    authors: Hsu CM,Palmeri ML,Segars WP,Veress AI,Dobbins JT 3rd

    更新日期:2011-10-01 00:00:00

  • Low-dose CT reconstruction using spatially encoded nonlocal penalty.

    abstract:PURPOSE:Computed tomography (CT) is one of the most used imaging modalities for imaging both symptomatic and asymptomatic patients. However, because of the high demand for lower radiation dose during CT scans, the reconstructed image can suffer from noise and artifacts due to the trade-off between the image quality and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12523

    authors: Kim K,El Fakhri G,Li Q

    更新日期:2017-10-01 00:00:00

  • Pulmonary nodule detection in CT images based on shape constraint CV model.

    abstract:PURPOSE:Accurate detection of pulmonary nodules remains a technical challenge in computer-aided diagnosis systems because some nodules may adhere to the blood vessels or the lung wall, which have low contrast compared to the surrounding tissues. In this paper, the analysis of typical shape features of candidate nodules...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4907961

    authors: Wang B,Tian X,Wang Q,Yang Y,Xie H,Zhang S,Gu L

    更新日期:2015-03-01 00:00:00

  • A comparison of reconstruction algorithms for C-arm mammography tomosynthesis.

    abstract::Digital tomosynthesis is an imaging technique to produce a tomographic image from a series of angular digital images in a manner similar to conventional focal plane tomography. Unlike film focal plane tomography, the acquisition of the data in a C-arm geometry causes the image receptor to be positioned at various angl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2219090

    authors: Rakowski JT,Dennis MJ

    更新日期:2006-08-01 00:00:00

  • Skeletal dosimetry for external exposures to photons based on microCT images of spongiosa: consideration of voxel resolution, cluster size, and medullary bone surfaces.

    abstract::Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skele...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3242266

    authors: Kramer R,Khoury HJ,Vieira JW,Robson Brown KA

    更新日期:2009-11-01 00:00:00

  • A survey of the information gained from planning treatment with a computer.

    abstract::We designed a questionnaire to be filled out by the physicist at the time of planning treatment with the aid of a computer in order to assess what was learned during the course of the planning session. We analyzed the results to gauge the impact of the 70 treatment planning sessions conducted during the one month peri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596302

    authors: Doppke KP,Goitein M

    更新日期:1988-03-01 00:00:00

  • Fast contour propagation for MR-guided prostate radiotherapy using convolutional neural networks.

    abstract:PURPOSE:To quickly and automatically propagate organ contours from pretreatment to fraction images in magnetic resonance (MR)-guided prostate external-beam radiotherapy. METHODS:Five prostate cancer patients underwent 20 fractions of image-guided external-beam radiotherapy on a 1.5 T MR-Linac system. For each patient,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13994

    authors: Eppenhof KAJ,Maspero M,Savenije MHF,de Boer JCJ,van der Voort van Zyp JRN,Raaymakers BW,Raaijmakers AJE,Veta M,van den Berg CAT,Pluim JPW

    更新日期:2020-03-01 00:00:00

  • A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems.

    abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2919724

    authors: Friedman SN,Cunningham IA

    更新日期:2008-06-01 00:00:00

  • Intercomparison of methods for image quality characterization. I. Modulation transfer function.

    abstract::The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2188816

    authors: Samei E,Ranger NT,Dobbins JT 3rd,Chen Y

    更新日期:2006-05-01 00:00:00

  • Technical note: the calibration of 90Y-labeled SIR-Spheres using a nondestructive spectroscopic assay.

    abstract::90Y-labeled SIR-Spheres are currently used to treat patients with hepatic metastases secondary to colorectal adenocarcinoma. In general, the prescribed activity is based on empirical data collected during clinical trials. The activity of the source vial is labeled by the manufacturer as 3.0 GBq +/- 10% and is not inde...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2889621

    authors: Selwyn R,Micka J,DeWerd L,Nickles R,Thomadsen B

    更新日期:2008-04-01 00:00:00

  • Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability.

    abstract:PURPOSE:The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. METHODS:A multisized imag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4923172

    authors: Solomon J,Wilson J,Samei E

    更新日期:2015-08-01 00:00:00

  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • The effect of pitch in multislice spiral/helical CT.

    abstract::The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598804

    authors: Wang G,Vannier MW

    更新日期:1999-12-01 00:00:00

  • Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905050

    authors: Veiga C,Lourenço AM,Mouinuddin S,van Herk M,Modat M,Ourselin S,Royle G,McClelland JR

    更新日期:2015-02-01 00:00:00

  • Peak SNR in automated coronary calcium scoring: selecting CT scan parameters and statistically defined scoring thresholds.

    abstract:PURPOSE:Development and verification of peak signal-to-noise ratio (SNR(P)) equations for determining optimum CT scanning and scoring parameters for a new automated coronary calcium scoring program (N-vivo). Experimental evaluation of the new program for scoring small calcium hydroxyapatite (CaHA) microspheres with sma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3442276

    authors: Arnold BA,Xiang P,Mao SS,Budoff MJ

    更新日期:2010-07-01 00:00:00

  • Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty.

    abstract::Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1791352

    authors: van Dijk E,Kolkman-Deurloo IK,Damen PM

    更新日期:2004-10-01 00:00:00

  • Measurement of transit time of a remote after-loading high dose rate brachytherapy source.

    abstract::Quantification of transit time of a remote after-loading high dose rate (HDR) brachytherapy source is important both for accurate treatment planning and for quality assurance checks. In this investigation, an HDR-1000 well ionization chamber and a precision electrometer are used to measure the transit time of the Ir-1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1386779

    authors: Sahoo N

    更新日期:2001-08-01 00:00:00

  • Nine-degrees-of-freedom flexmap for a cone-beam computed tomography imaging device with independently movable source and detector.

    abstract:PURPOSE:Couch-mounted cone-beam computed tomography (CBCT) imaging devices with independently rotatable x-ray source and flat-panel detector arms for acquisitions of arbitrary regions of interest (ROI) have recently been introduced in image-guided radiotherapy (IGRT). This work analyzes mechanical limitations and gravi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12033

    authors: Keuschnigg P,Kellner D,Fritscher K,Zechner A,Mayer U,Huber P,Sedlmayer F,Deutschmann H,Steininger P

    更新日期:2017-01-01 00:00:00

  • Eigencolor radiochromic film dosimetry.

    abstract:PURPOSE:The goal of this work is to propose a new multichannel method correcting for systematic thickness disturbances and to evaluate its precision in relevant radiation dosimetry applications. METHODS:The eigencolor ratio technique is introduced and theoretically developed to provide a method correcting for thicknes...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14742

    authors: Bouchard H,Billas I,Subie A,Duane S

    更新日期:2021-02-01 00:00:00

  • Influence of 0.35 T magnetic field on the response of EBT3 and EBT-XD radiochromic films.

    abstract:PURPOSE:To investigate the inconsistency of recent literature on the effect of magnetic field on the response of radiochromic films, we studied the influence of 0.35 T magnetic field on dosimetric response of EBT3 and EBT-XD GafchromicTM films. METHODS:Two different models of radiochromic films, EBT3 and EBT-XD, were ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14313

    authors: Darafsheh A,Hao Y,Maraghechi B,Cammin J,Reynoso FJ,Khan R

    更新日期:2020-09-01 00:00:00

  • Semiautomated registration of pre- and intraoperative CT for image-guided percutaneous liver tumor ablation interventions.

    abstract:PURPOSE:In CT-guided liver tumor ablation interventions, registration of a preoperative contrast-enhanced CT image to the intraoperative CT image is hypothesized to improve guidance. This is a highly challenging registration task due to differences in patient poses and large deformations, and therefore high registratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12332

    authors: Gunay G,Luu MH,Moelker A,van Walsum T,Klein S

    更新日期:2017-07-01 00:00:00

  • Detection and diagnosis of colitis on computed tomography using deep convolutional neural networks.

    abstract:PURPOSE:Colitis refers to inflammation of the inner lining of the colon that is frequently associated with infection and allergic reactions. In this paper, we propose deep convolutional neural networks methods for lesion-level colitis detection and a support vector machine (SVM) classifier for patient-level colitis dia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12399

    authors: Liu J,Wang D,Lu L,Wei Z,Kim L,Turkbey EB,Sahiner B,Petrick NA,Summers RM

    更新日期:2017-09-01 00:00:00