Abstract:
:Digital tomosynthesis is an imaging technique to produce a tomographic image from a series of angular digital images in a manner similar to conventional focal plane tomography. Unlike film focal plane tomography, the acquisition of the data in a C-arm geometry causes the image receptor to be positioned at various angles to the reconstruction tomogram. The digital nature of the data allows for input images to be combined into the desired plane with the flexibility of generating tomograms of many separate planes from a single set of input data. Angular datasets were obtained of a low contrast detectability (LCD) phantom and cadaver breast utilizing a Lorad stereotactic biopsy unit with a coupled source and digital detector in a C-arm configuration. Datasets of 9 and 41 low-dose projections were collected over a 30 degrees angular range. Tomographic images were reconstructed using a Backprojection (BP) algorithm, an Iterative Subtraction (IS) algorithm that allows the partial subtraction of out-of-focus planes, and an Algebraic Reconstruction (AR) algorithm. These were compared with single view digital radiographs. The methods' effectiveness at enhancing visibility of an obscured LCD phantom was quantified in terms of the Signal to Noise Ratio (SNR), and Signal to Background Ratio (SBR), all normalized to the metric value for the single projection image. The methods' effectiveness at removing ghosting artifacts in a cadaver breast was quantified in terms of the Artifact Spread Function (ASF). The technology proved effective at partially removing out of focus structures and enhancing SNR and SBR. The normalized SNR was highest at 4.85 for the obscured LCD phantom, using nine projections and IS algorithm. The normalized SBR was highest at 23.2 for the obscured LCD phantom, using 41 projections and an AR algorithm. The highest normalized metric values occurred with the obscured phantom. This supports the assertion that the greatest value of tomosynthesis is in imaging fibroglandular breasts. The ASF performance was best with the AR technique and nine projections.
journal_name
Med Physjournal_title
Medical physicsauthors
Rakowski JT,Dennis MJdoi
10.1118/1.2219090subject
Has Abstractpub_date
2006-08-01 00:00:00pages
3018-32issue
8eissn
0094-2405issn
2473-4209journal_volume
33pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Water equivalent diameter (WED) is the preferred surrogate for patient size in CT. It is better than geometric size surrogates and patient weight/height/BMI/age because it correlates the best with x-ray attenuation. The administration of oral/IV contrast agents increases a patient's attenuation and should there...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14721
更新日期:2021-01-13 00:00:00
abstract:PURPOSE:Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4944501
更新日期:2016-04-01 00:00:00
abstract:PURPOSE:Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589131
更新日期:2011-06-01 00:00:00
abstract:PURPOSE:To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. METHODS:A PET-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4867856
更新日期:2014-04-01 00:00:00
abstract:PURPOSE:To demonstrate, via Monte Carlo simulation, that an image obtained from the patient-generated scattered radiation forced to impinge on the detector from a known direction by means of parallel-focused grids, can be used to complement the information conveyed by the primary image, such that accurate stereoscopic ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12712
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:For stereotactic radiosurgery (SRS), accurate evaluation of dose-volume metrics for small structures is necessary. The purpose of this study was to compare the DVH metric capabilities of five commercially available SRS DVH analysis tools (Eclipse, Elements, Raystation, MIM, and Velocity). METHODS:DICOM RTdose ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14645
更新日期:2020-12-09 00:00:00
abstract:PURPOSE:To evaluate the image quality of virtual monochromatic images synthesized from dual-source dual-energy computed tomography (CT) in comparison with conventional polychromatic single-energy CT for the same radiation dose. METHODS:In dual-energy CT, besides the material-specific information, one may also synthesi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3658568
更新日期:2011-12-01 00:00:00
abstract:PURPOSE:Partial scan reconstruction (PSR) artifacts are present in myocardial perfusion imaging using dynamic multidetector computed tomography (MDCT). PSR artifacts appear as temporal CT number variations due to inconsistencies in the angular data range used to reconstruct images and compromise the quantitative value ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3665767
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:This paper describes the clinical implementation and medical commissioning of the MedAustron Particle Therapy Accelerator (MAPTA) for non-isocentric scanned proton beam treatments. METHODS:Medical physics involvement during technical commissioning work is presented. Acceptance testing procedures, including adv...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13928
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:The lateral edge of a proton therapy beam is commonly used to achieve conformality to the treatment volume where critical structures reside close to the target. However, when treating shallow depths, the lateral edge of a pencil beam scanning (PBS) system may be broader than that of a double scattered (DS) syst...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941957
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:This work is to evaluate the effects of Compton current generation in three small-volume ionization chambers on measured beam characteristics for electron fields. METHODS:Beam scans were performed using Exradin A16, A26, and PTW 31014 microchambers. Scans with varying chamber components shielded were performed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4929555
更新日期:2015-10-01 00:00:00
abstract::Intensity Modulated Arc Therapy (IMAT) is a rotational variant of Intensity Modulated Radiation Therapy (IMRT) that can be implemented with or without angular dose rate optimization. The purpose of this study is to determine the inter-relationship among arc range, Multi-Leaf Collimator (MLC) leaf positions and angular...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965975
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:In C-arm computed tomography (CT), the field of view (FOV) is often not sufficient to acquire certain anatomical structures, e.g., a full hip or thorax. Proposed methods to extend the FOV use a fixed detector displacement and a 360° scan range to double the radius of the FOV. These trajectories are designed for...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4915542
更新日期:2015-05-01 00:00:00
abstract::An artificial neural network using input data derived from attenuation measurements was trained to generate spectral profiles (relative number of photons versus energy). Once the relative spectral distribution is reconstructed, absolute spectra (number of photons per unit exposure spectral distribution is reconstructe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596495
更新日期:1990-07-01 00:00:00
abstract:PURPOSE:The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox). METHODS:An antitumor drug Dox, an orthotopic animal prostate tumor model using human prostate cancer, LNCaP cell line, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4705346
更新日期:2012-05-01 00:00:00
abstract::An algorithmic solution to the biological effective dose (BED) calculation from the Lea-Catcheside formula for a piecewise defined function is presented. Data from patients treated for metastatic thyroid cancer were used to illustrate the solution. The Lea-Catcheside formula for the G-factor of the BED is integrated n...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3070587
更新日期:2009-03-01 00:00:00
abstract::The photon spectra in vacuum around four types of 192Ir HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on 192Ir decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare 192Ir source and around each of fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598763
更新日期:1999-11-01 00:00:00
abstract::Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detecto...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1289375
更新日期:2000-09-01 00:00:00
abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284974
更新日期:2010-02-01 00:00:00
abstract::Depth dose characteristics of 24-MV beams from a medical linear accelerator at various SSDs have been measured. The dose buildup, percent depth dose (PDD), and output were measured using ionization chambers and a diode detector under full scatter. Surface dose ranged from 8% to 51% depending upon the collimator settin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596673
更新日期:1991-03-01 00:00:00
abstract:PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3456598
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13804
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4918581
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:Two ultra-high-resolution (UHR) computed tomography (CT) scanners are clinically available. One is achieved by a CT system with a 0.25 mm × 160 row detector (Detector-UHR), whereas the other is with a 0.6 mm × 32 row detector with in-plane comb filtering in a dual source CT (Comb-UHR). We compared radiation dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13949
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:Radiotherapy, especially with charged particles, is sensitive to executional and preparational uncertainties that propagate to uncertainty in dose and plan quality indicators, for example, dose-volume histograms (DVHs). Current approaches to quantify and mitigate such uncertainties rely on explicitly computed e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14414
更新日期:2020-10-01 00:00:00
abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1644515
更新日期:2004-03-01 00:00:00
abstract:PURPOSE:To assess the temporal and spatial accuracy of the GateCT™ system (VisionRT, London, UK), a recently released respiratory tracking system for 4DCT, under both ideal and nonideal respiratory conditions. METHODS:Three experiments were performed by benchmarking and comparing its results with the ground-truth inpu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3671941
更新日期:2012-01-01 00:00:00
abstract::Conventional IMRT dose verification using film and ion chamber measurements is useful but limited with respect to the actual dose distribution received by the patient. The Monte Carlo simulation has been introduced as an independent dose verification tool for IMRT using the patient CT data and MLC leaf sequence files,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2208916
更新日期:2006-07-01 00:00:00
abstract:PURPOSE:To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. METHODS:A total of eight clinical lung tumor cases were recalculated using Monte Carlo me...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4938580
更新日期:2016-01-01 00:00:00
abstract:PURPOSE:The automated correct segmentation of left and right lungs is a nontrivial problem, because the tissue layer between both lungs can be quite thin. In the case of lung segmentation with left and right lung models, overlapping segmentations can occur. In this paper, the authors address this issue and propose a so...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4894817
更新日期:2014-10-01 00:00:00