Abstract:
PURPOSE:To evaluate the image quality of virtual monochromatic images synthesized from dual-source dual-energy computed tomography (CT) in comparison with conventional polychromatic single-energy CT for the same radiation dose. METHODS:In dual-energy CT, besides the material-specific information, one may also synthesize monochromatic images at different energies, which can be used for routine diagnosis similar to conventional polychromatic single-energy images. In this work, the authors assessed whether virtual monochromatic images generated from dual-source CT scanners had an image quality similar to that of polychromatic single-energy images for the same radiation dose. First, the authors provided a theoretical analysis of the optimal monochromatic energy for either the minimum noise level or the highest iodine contrast to noise ratio (CNR) for a given patient size and dose partitioning between the low- and high-energy scans. Second, the authors performed an experimental study on a dual-source CT scanner to evaluate the noise and iodine CNR in monochromatic images. A thoracic phantom with three sizes of attenuating rings was used to represent four adult sizes. For each phantom size, three dose partitionings between the low-energy (80 kV) and the high-energy (140 kV) scans were used in the dual-energy scan. Monochromatic images at eight energies (40 to 110 keV) were generated for each scan. Phantoms were also scanned at each of the four polychromatic single energy (80, 100, 120, and 140 kV) with the same radiation dose. RESULTS:The optimal virtual monochromatic energy depends on several factors: phantom size, partitioning of the radiation dose between low- and high-energy scans, and the image quality metrics to be optimized. With the increase of phantom size, the optimal monochromatic energy increased. With the increased percentage of radiation dose on the low energy scan, the optimal monochromatic energy decreased. When maximizing the iodine CNR in monochromatic images, the optimal energy was lower than that when minimizing noise level. When the total radiation dose was equally distributed between low and high energy in dual-energy scans, for minimum noise, the optimal energies were 68, 71, 74, and 77 keV for small, medium, large, and extra-large (xlarge) phantoms, respectively; for maximum iodine CNR, the optimal energies were 66, 68, 70, 72 keV. With the optimal monochromatic energy, the noise level was similar to and the CNR was better than that in a single-energy scan at 120 kV for the same radiation dose. Compared to an 80 kV scan, however, the iodine CNR in monochromatic images was lower for the small, medium, and large phantoms. CONCLUSIONS:In dual-source dual-energy CT, optimal virtual monochromatic energy depends on patient size, dose partitioning, and the image quality metric optimized. With the optimal monochromatic energy, the noise level was similar to and the iodine CNR was better than that in 120 kV images for the same radiation dose. Compared to single-energy 80 kV images, the iodine CNR in virtual monochromatic images was lower for small to large phantom sizes.
journal_name
Med Physjournal_title
Medical physicsauthors
Yu L,Christner JA,Leng S,Wang J,Fletcher JG,McCollough CHdoi
10.1118/1.3658568subject
Has Abstractpub_date
2011-12-01 00:00:00pages
6371-9issue
12eissn
0094-2405issn
2473-4209journal_volume
38pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Modern radiotherapy linacs often use carbon fibre for their couch tops due to its radio translucent properties. Beam attenuation by the couches is often ignored during planning and MU calculation. This work examines beam attenuation and loss of "skin sparing" (dose build up region) when various photon beams transit ei...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965951
更新日期:2008-07-01 00:00:00
abstract::Subsecond single-slice, multi-slice or cone-beam spiral computed tomography (SSCT, MSCT, CBCT) offer great potential for improving heart imaging. Together with the newly developed phase-correlated cardiac reconstruction algorithms 180 degrees MCD and 180 degrees MCI [Med. Phys. 27, 1881-1902 (2000)] or related algorit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1487861
更新日期:2002-07-01 00:00:00
abstract::The same calibration grade ionization chamber and electrometer were sequentially sent to all five currently AAPM Accredited Dosimetry Calibration Laboratories (ADCL). A Cesium-137 based check device was utilized to ensure chamber and electrometer factor constancy and showed a maximum deviation of 0.32% (typically less...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596880
更新日期:1992-01-01 00:00:00
abstract::Bioluminescent imaging (BLI) of luciferase-expressing cells in live small animals is a powerful technique for investigating tumor growth, metastasis, and specific biological molecular events. Three-dimensional imaging would greatly enhance applications in biomedicine since light emitting cell populations could be unam...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2138007
更新日期:2006-01-01 00:00:00
abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1118/1.4747342
更新日期:2012-09-01 00:00:00
abstract::The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of irradiation. When acquiring...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1576229
更新日期:2003-06-01 00:00:00
abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594206
更新日期:1975-11-01 00:00:00
abstract:PURPOSE:In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accou...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4893278
更新日期:2014-09-01 00:00:00
abstract::Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 4...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1791352
更新日期:2004-10-01 00:00:00
abstract:PURPOSE:There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3475942
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734811
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To develop an individually optimized contrast-enhanced (CE) 4D-computed tomography (CT) for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). METHODS:Ten PDA patients were enrolled. Each underwent three CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4963213
更新日期:2016-10-01 00:00:00
abstract:PURPOSE:The purpose of this paper was to present a method of determining the dose profile of the beam bow-tie filter (BTF) without the need for fixing the x ray tube in a position or using special instruments or dosimeters other than the ordinary types of ion chambers used for CT dosimetry (e.g., Farmer chamber). METH...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13203
更新日期:2018-11-01 00:00:00
abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594458
更新日期:1978-11-01 00:00:00
abstract:PURPOSE:This work describes the performance characterization of a cone-beam CT-guided radiosurgery device, the Gamma Knife® Icon™. METHODS:The performance tests have been categorized into: (a) image quality and mechanical integrity; (b) image coregistration fidelity; (c) adaptive treatment delivery quality; (d) high d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13073
更新日期:2018-06-29 00:00:00
abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2008428
更新日期:2005-09-01 00:00:00
abstract:PURPOSE:To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12463
更新日期:2017-10-01 00:00:00
abstract::Ionization chambers of varying inside diameter have been used to investigate the penumbral region of 60Co, 6-MV, and 31-MV x-ray beams. Measurements were made in water at varying depths up to 25 cm for a square field of side length 10 cm. The dependence of the penumbral widths on both the inside diameter of the ioniza...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595963
更新日期:1986-01-01 00:00:00
abstract::Three Monte Carlo photon/electron transport codes (GEPTS, EGSnrc, and MCNP) are bench-marked against dose measurements in homogeneous (both low- and high-Z) media as well as at interfaces. A brief overview on physical models used by each code for photon and electron (positron) transport is given. Absolute calorimetric...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1473134
更新日期:2002-05-01 00:00:00
abstract:PURPOSE:This work is to evaluate the effects of Compton current generation in three small-volume ionization chambers on measured beam characteristics for electron fields. METHODS:Beam scans were performed using Exradin A16, A26, and PTW 31014 microchambers. Scans with varying chamber components shielded were performed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4929555
更新日期:2015-10-01 00:00:00
abstract::An automated data-acquisition and analysis system has been developed for dosimetry measurements on the pion therapy beam at the Clinton P. Anderson Meson Physics Facility Biomedical Channel in Los Alamos using a PDP-11/45 computer and CAMAC interface. Initialization, test, and monitor programs allow the user to set th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594418
更新日期:1978-03-01 00:00:00
abstract::Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8 +/- 0.35 at 25.5 keV (50 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2219330
更新日期:2006-08-01 00:00:00
abstract:PURPOSE:To apply the recent code of practice from the IAEA/AAPM, TRS 483, to helical tomotherapy (HT) for reference and relative dosimetry obtaining correction factors for the Exradin A1SL ionization chamber. METHODS:The beam quality correction factor for the A1SL chamber was obtained through three different approache...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13855
更新日期:2019-12-01 00:00:00
abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595508
更新日期:1984-05-01 00:00:00
abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1564091
更新日期:2003-05-01 00:00:00
abstract:PURPOSE:To develop a deformable mapping technique to match corresponding lesions between digital breast tomosynthesis (DBT) and automated breast ultrasound (ABUS) images. METHODS:External fiducial markers were attached to the surface of two CIRS multi-modality compressible breast phantoms (A and B) containing multiple...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13113
更新日期:2018-10-01 00:00:00
abstract::Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accuratel...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598576
更新日期:1999-05-01 00:00:00
abstract:PURPOSE:Obtaining an integral depth-dose (IDD) curve using a recently developed acrylic-disk radiation sensor (ADRS) is time-consuming because its single structure requires point-by-point measurements in a water phantom. The goal of this study was to verify the ability of a newly designed multilayer ADRS, composed of 2...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14326
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. METHODS:MD Anderson Cancer Center Institutional Review Board appro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906178
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4812429
更新日期:2013-08-01 00:00:00