A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams.

Abstract:

PURPOSE:The lateral edge of a proton therapy beam is commonly used to achieve conformality to the treatment volume where critical structures reside close to the target. However, when treating shallow depths, the lateral edge of a pencil beam scanning (PBS) system may be broader than that of a double scattered (DS) system. Use of a range-shifter to degrade the beam and allow treatment of very shallow depths further blurs the lateral edge. The authors investigate the potential use of a collimator with a PBS system for delivery of 3D uniform dose-volumes to a water-tank phantom, identifying the key factors controlling the width of the lateral edge. METHODS:The geant4 application for tomographic emission (gate) Monte Carlo (MC) environment was used, following validation against previously published data. Key parameters for PBS beams were investigated to assess their impact on the lateral edge of both monoenergetic beams and uniform dose-volumes. These parameters included nozzle-to-surface distance (NSD), vacuum window-to-surface distance (VSD), use of a range-shifter, and spot optimization parameters. RESULTS:The lateral edge of an uncollimated PBS beam is particularly sensitive to VSD and NSD. While use of a range-shifter blurs the lateral edge, collimation allows the edge to be sharpened to between 2 and 4 mm depending on the depth of the target. Optimization of the spot weightings alone can provide a penumbral width close to that of a single spot, but also leads to poorer uniformity near the edge of the target volume. CONCLUSIONS:Collimation of PBS beams should be considered for superficial targets particularly for beams delivered through a range-shifter, since the resultant sharpening of the lateral edge will allow improved sparing of adjacent normal tissues. Further work is needed to develop collimators which are integrated into both nozzle designs and planning system optimization algorithms.

journal_name

Med Phys

journal_title

Medical physics

authors

Charlwood FC,Aitkenhead AH,Mackay RI

doi

10.1118/1.4941957

subject

Has Abstract

pub_date

2016-03-01 00:00:00

pages

1462-72

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

43

pub_type

杂志文章
  • Characteristics of sensitometric curves of radiographic films.

    abstract::A new type of radiographic film, EDR (extended dose range) film, has been recently become available for film dosimetry. It is particularly attractive for composite isodose verification of intensity modulated radiation therapy because of its low sensitivity relative to the more common Kodak XV film. For XV film, the re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1568979

    authors: Zhu XR,Yoo S,Jursinic PA,Grimm DF,Lopez F,Rownd JJ,Gillin MT

    更新日期:2003-05-01 00:00:00

  • Effects of constant frequency noise in magnetic resonance imaging with nonuniform k-space sampling.

    abstract::Magnetic resonance images can be compromised by constant frequency (CF) noise, such as radio frequency (RF) noise. We investigate the effects of CF noise in four imaging methods with non-uniform k-space sampling: single-shot echo-planar imaging (EPI) with sinusoidal readout gradients, phase-encoded echo-planar spectro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1496096

    authors: Du W,Karczmar GS,Pan X

    更新日期:2002-08-01 00:00:00

  • Technical Note: Noninvasive mid-IR fiber-optic evanescent wave spectroscopy (FEWS) for early detection of skin cancers.

    abstract:PURPOSE:Melanoma is the most lethal of the three primary skin cancers, including also basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), which are less lethal. The accepted diagnosis process involves manually observing a suspicious lesion through a Dermascope (i.e., a magnifying glass), followed by a biopsy....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14471

    authors: Basov S,Dankner Y,Weinstein M,Katzir A,Platkov M

    更新日期:2020-11-01 00:00:00

  • Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery.

    abstract::The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response ne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1915017

    authors: Vedam S,Docef A,Fix M,Murphy M,Keall P

    更新日期:2005-06-01 00:00:00

  • Wedge-shaped dose distributions by computer-controlled collimator motion.

    abstract::We have recently installed a linear accelerator, modified to allow computer control of several machine parameters during irradiation of the patient. As an initial feasibility study of computer-controlled radiation therapy, its application to produce wedge-shaped dose distributions by moving the collimator jaws has bee...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594440

    authors: Kijewski PK,Chin LM,Bjärngard BE

    更新日期:1978-09-01 00:00:00

  • GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications.

    abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2218314

    authors: Nicolini G,Fogliata A,Vanetti E,Clivio A,Cozzi L

    更新日期:2006-08-01 00:00:00

  • Dual-film cassette technique for studying the effect of radiographic image quality on diagnostic accuracy.

    abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595546

    authors: Higashida Y,Doi K,Lehr JL,MacMahon H

    更新日期:1984-09-01 00:00:00

  • CeBr3 scintillators for 4 He prompt gamma spectroscopy: Results from a Monte Carlo optimization study.

    abstract:PURPOSE:Range uncertainties limit the potential of charged particle therapy. In vivo and online range verification techniques could increase the confidence in the dose delivery distribution and lead to more conformal treatments. Prompt gamma imaging and prompt gamma spectroscopy (PGS) have been demonstrated for such a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12795

    authors: Dal Bello R,Magalhaes Martins P,Seco J

    更新日期:2018-04-01 00:00:00

  • Computation of beam quality parameters for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations in mammography.

    abstract::A computer program was implemented to predict mammography x-ray beam parameters in the range 20-40 kV for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations. The computation method used to simulate mammography x-ray spectra is based on the Boone et al. model. The beam quality parameters such as the half-value la...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1608498

    authors: Kharrati H,Zarrad B

    更新日期:2003-10-01 00:00:00

  • A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

    abstract:PURPOSE:The quality of tomographic images is directly affected by the system model being used in image reconstruction. An accurate system matrix is desirable for high-resolution image reconstruction, but it often leads to high computation cost. In this work the authors present a maximum a posteriori reconstruction algo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3284980

    authors: Fu L,Qi J

    更新日期:2010-02-01 00:00:00

  • Best estimate of luminal cross-sectional area of coronary arteries from angiograms.

    abstract::We have reexamined the problem of estimating the luminal area of an elliptically shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cases of two orthogonal views, closed form expressions have ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596296

    authors: Lee PL,Selzer RH

    更新日期:1988-07-01 00:00:00

  • Neutron and gamma spectroscopy for clinical dosimetry.

    abstract::Neutron and photon energy spectra were measured in different depths and lateral positions in tissue-equivalent phantoms exposed to a therapeutical 14.1 MeV neutron beam. Intensity weighted mass energy absorption coefficients were derived for application in ionization chamber dosimetry in mixed neutron-gamma fields. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594744

    authors: Schmidt R,Magiera E,Scobel W

    更新日期:1980-09-01 00:00:00

  • Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.

    abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812609

    authors: Niu H,Hsi WC,Chu JC,Kirk MC,Kouwenhoven E

    更新日期:2004-12-01 00:00:00

  • Direct aperture optimization: a turnkey solution for step-and-shoot IMRT.

    abstract::IMRT treatment plans for step-and-shoot delivery have traditionally been produced through the optimization of intensity distributions (or maps) for each beam angle. The optimization step is followed by the application of a leaf-sequencing algorithm that translates each intensity map into a set of deliverable aperture ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477415

    authors: Shepard DM,Earl MA,Li XA,Naqvi S,Yu C

    更新日期:2002-06-01 00:00:00

  • A novel respiratory tracking system for smart-gated PET acquisition.

    abstract:PURPOSE:In this study, the authors validated a novel respiratory tracking device, the multidimensional respiratory tracking (MDRT) system, that was designed to assist in correcting for respiratory motion in PET/CT images. The authors also investigated a novel PET acquisition technique, smart gating (SG), that enables t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3523100

    authors: Nehmeh SA,Haj-Ali AA,Qing C,Stearns C,Kalaigian H,Kohlmyer S,Schoder H,Ho AY,Larson SM,Humm JL

    更新日期:2011-01-01 00:00:00

  • TU-G-BRB-01: Continuous Path Optimization for Non-Coplanar Variant SAD IMRT Delivery Using C-Arm Machines.

    abstract:PURPOSE:To develop and investigate a continuous path optimization methodology to traverse prescribed non-coplanar IMRT beams with variant SADs, by orchestrating the couch and gantry movement with zero-collision, minimal patient motion consequence and machine travel time. METHODS:We convert the given collision zone def...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735996

    authors: Ruan D,Dong P,Low D,Sheng K

    更新日期:2012-06-01 00:00:00

  • A Dirichlet process mixture model for automatic (18)F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions.

    abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947123

    authors: Giri MG,Cavedon C,Mazzarotto R,Ferdeghini M

    更新日期:2016-05-01 00:00:00

  • Validation of Monte Carlo calculated surface doses for megavoltage photon beams.

    abstract::Recent work has shown that there is significant uncertainty in measuring build-up doses in mega-voltage photon beams especially at high energies. In this present investigation we used a phantom-embedded extrapolation chamber (PEEC) made of Solid Water to validate Monte Carlo (MC)-calculated doses in the dose build-up ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1829401

    authors: Abdel-Rahman W,Seuntjens JP,Verhaegen F,Deblois F,Podgorsak EB

    更新日期:2005-01-01 00:00:00

  • Efficient implementations of a pseudodynamical stochastic filtering strategy for static elastography.

    abstract::A computationally efficient pseudodynamical filtering setup is established for elasticity imaging (i.e., reconstruction of shear modulus distribution) in soft-tissue organs given statically recorded and partially measured displacement data. Unlike a regularized quasi-Newton method (QNM) that needs inversion of ill-con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3158808

    authors: Banerjee B,Roy D,Vasu RM

    更新日期:2009-08-01 00:00:00

  • SU-E-T-541: Dose Calculation Algorithm for External Neutron Radiotherapy Based on Pencil Beam Method.

    abstract:PURPOSE:To evaluate the availability and performance of pencil beam algorithm for fast neutrons radiotherapy dose calculations and to achieve improvements in universality, speed and inhomogeneities corrections. METHODS:Pencil beam (PB) method uses integration of dose kernel cross field size to estimate dose distributi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735630

    authors: Moiseev A,Klimanov V

    更新日期:2012-06-01 00:00:00

  • Noncoplanar VMAT for nasopharyngeal tumors: Plan quality versus treatment time.

    abstract:PURPOSE:The authors investigated the potential of optimized noncoplanar irradiation trajectories for volumetric modulated arc therapy (VMAT) treatments of nasopharyngeal patients and studied the trade-off between treatment plan quality and delivery time in radiation therapy. METHODS:For three nasopharyngeal patients, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914863

    authors: Wild E,Bangert M,Nill S,Oelfke U

    更新日期:2015-05-01 00:00:00

  • Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners.

    abstract:PURPOSE:Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3426000

    authors: Mathieu KB,McNitt-Gray MF,Zhang D,Kim HJ,Cody DD

    更新日期:2010-08-01 00:00:00

  • Lung dosimetry in a linac-MRI radiotherapy unit with a longitudinal magnetic field.

    abstract:PURPOSE:There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3475942

    authors: Kirkby C,Murray B,Rathee S,Fallone BG

    更新日期:2010-09-01 00:00:00

  • Vision 20/20: Mammographic breast density and its clinical applications.

    abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4935141

    authors: Ng KH,Lau S

    更新日期:2015-12-01 00:00:00

  • Investigating the feasibility of photon-counting K-edge imaging at high x-ray fluxes using nonlinearity corrections.

    abstract:PURPOSE:Pulse pileup occurring at high x-ray fluxes can severely degrade the energy resolution provided by a photon counting detector, which can represent a problem in spectroscopic CT when performing quantitative material discrimination tasks. As the effects of pileup can be most easily seen as a degradation of a dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4820535

    authors: Rink K,Oelfke U,Fiederle M,Zuber M,Koenig T

    更新日期:2013-10-01 00:00:00

  • SU-E-I-103: Detecting Anomalous Pixels and Correlated Artifacts in Digital Detectors from Flat-Field Images.

    abstract:PURPOSE:Anomalous pixels may be defined as those pixels whose exposure response relationship is deviant from the typical, expected or calibrated response. A group of anomalous pixels may Result in visible correlated artifacts. Here we demonstrate an approach to identify anomalous pixels and correlated artifacts using f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734820

    authors: Dave J,Gingold E,Yorkston J,Bercha I,Goldman L,Walz-Flannigan A,Willis C

    更新日期:2012-06-01 00:00:00

  • Factors influencing the performance of patient specific quality assurance for pencil beam scanning IMPT fields.

    abstract:PURPOSE:A detailed analysis of 2728 intensity modulated proton therapy (IMPT) fields that were clinically delivered to patients between 2007 and 2013 at Paul Scherrer Institute (PSI) was performed. The aim of this study was to analyze the results of patient specific dosimetric verifications and to assess possible corre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964449

    authors: Trnková P,Bolsi A,Albertini F,Weber DC,Lomax AJ

    更新日期:2016-11-01 00:00:00

  • SU-E-T-04: Repair Kinetics of Sublethal Damage in Rat Cervical Spinal Cord - Application of the GLQ Model Incorporating Reciprocal Time Pattern.

    abstract:PURPOSE:The repair rate conventionally assumed to be constant during the entire radiation course. However, increasing evidences from animal studies show that the repair process may slow down with time and the experimental data does not fit an exponential pattern. To address this enigma, we presented a generalized linea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735058

    authors: Huang Z,Mayr NA,Lo SS,McLawhorn R,Gao M,Liu T,Yuh W

    更新日期:2012-06-01 00:00:00

  • The use of a diode matrix in commissioning activities for electron energies > or = 9 MeV: a feasibility study.

    abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3081414

    authors: Borca VC,Pasquino M,Ozzello F,Tofani S

    更新日期:2009-04-01 00:00:00

  • Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.

    abstract:PURPOSE:To investigate the accuracy of output factor measurements using a commercial (Exradin W1, SI) and a prototype, "in-house" developed, plastic scintillation dosimeter (PSD) in small photon fields. METHODS:Repetitive detector-specific output factor OFdet measurements were performed in water (parallel to the CAX) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12064

    authors: Papaconstadopoulos P,Archambault L,Seuntjens J

    更新日期:2017-02-01 00:00:00