Abstract:
:A new type of radiographic film, EDR (extended dose range) film, has been recently become available for film dosimetry. It is particularly attractive for composite isodose verification of intensity modulated radiation therapy because of its low sensitivity relative to the more common Kodak XV film. For XV film, the relationship between optical density and dose, commonly known as the sensitometric curve, depends linearly on the dose at low densities. Unlike XV film, the sensitometric curve of EDR film irradiated by megavoltage x rays is not linearly dependent on the dose at low densities. In this work, to understand the mechanisms governing the shape of the sensitometric curves, EDR film was studied with kilovoltage x rays, 60Co gamma rays, megavoltage x rays, and electron beams. As a comparison, XV film was also studied with the same beams mentioned above. The model originally developed by Silberstein [J. Opt. Soc. Am. 35, 93-107, 1945)] is used to fit experimental data. It is found that the single hit model can be used to predict the sensitometric curve for XV films irradiated by all beams used in this work and for EDR films exposed to kilovoltage x rays. For EDR film irradiated by 60Co gamma rays, megavoltage x rays, and electron beams, the double hit model is used to fit the sensitometric curves. For doses less than 100 cGy, a systematic difference between measured densities and that predicted by the double hit model is observed. Possible causes of the observed differences are discussed. The results of this work provide a theoretical explanation of the sensitometric behavior of EDR film.
journal_name
Med Physjournal_title
Medical physicsauthors
Zhu XR,Yoo S,Jursinic PA,Grimm DF,Lopez F,Rownd JJ,Gillin MTdoi
10.1118/1.1568979subject
Has Abstractpub_date
2003-05-01 00:00:00pages
912-9issue
5eissn
0094-2405issn
2473-4209journal_volume
30pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Respiratory motion compensation in PET/CT and PET/MRI is essential as motion is a source of image degradation (motion blur, attenuation artifacts). In previous work, we developed a direct method for joint image reconstruction/motion estimation (JRM) for attenuation-corrected (AC) respiratory-gated PET, which us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12253
更新日期:2017-06-01 00:00:00
abstract::The gamma-ray dose component of a d(80) + Be neutron beam was measured with a 6Li-shielded Geiger-Mueller counter in a tissue-equivalent liquid phantom. The proportion of gamma-ray dose to total dose increased from 0.07 near the surface to 0.09 at 25 cm depth. Due to thermal neutron sensitivity, the G-M count rate inc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594571
更新日期:1979-05-01 00:00:00
abstract::Various radionuclides have been proposed for systemic tumor therapy. However, in most dosimetric analysis of proposed radionuclides the charged particles are taken into consideration while the potential photons are ignored. The photons will cause undesirable irradiation of normal tissue, and increase the probability o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2229428
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14417
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:To evaluate the feasibility of using an objective computer-aided system to assess bladder cancer stage in CT Urography (CTU). MATERIALS AND METHODS:A dataset consisting of 84 bladder cancer lesions from 76 CTU cases was used to develop the computerized system for bladder cancer staging based on machine learnin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12510
更新日期:2017-11-01 00:00:00
abstract::Plaque rupture with superimposed thrombosis is the main cause of the acute coronary syndromes of unstable angina, myocardial infarction, and sudden death. Endothelial disruption leading to plaque rupture may relate to mechanical fatigue associated with cyclic flexion of plaques. A novel method is proposed to assess st...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1593635
更新日期:2003-11-01 00:00:00
abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792462
更新日期:2013-03-01 00:00:00
abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597218
更新日期:1994-11-01 00:00:00
abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734893
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:In previous work, the authors developed and demonstrated the concept of an image reconstruction procedure aimed to unify gated and dynamic nuclear cardiac imaging, which the authors have termed five-dimensional (5D) SPECT. Gated imaging permits the clinician to evaluate wall motion and, through the use of stres...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3481507
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4863510
更新日期:2014-03-01 00:00:00
abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597681
更新日期:1996-04-01 00:00:00
abstract:PURPOSE:The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. METHODS:For 11 lung cancer patients a long training fluoroscopy was acquired before the first trea...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.4794489
更新日期:2013-04-01 00:00:00
abstract::The purpose of this work is to calculate the dose perturbations due to the presence of iodine contrast media in catheter-based intravascular brachytherapy (IVBT). The EGSnrc Monte Carlo system was used to perform the calculation for the two most commonly used beta and gamma sources (90Sr and 192Ir as well as for a var...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1367279
更新日期:2001-05-01 00:00:00
abstract::Anisotropy of dose distributions around 103Pd, 125I, and 192Ir sources for interstitial brachytherapy was examined. Dose rates around 125I models 6702 and 6711 and 192Ir sources were measured using lithium fluoride thermoluminescence dosimeters (LiF TLDs) in a water-equivalent, solid phantom. From these measured data ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597110
更新日期:1993-09-01 00:00:00
abstract::Positron emission mammography (PEM) is a new, specialized imaging modality utilizing PET radiopharmaceuticals to detect breast cancer. The capabilities and limitations of PEM in detecting breast tumors were investigated with a series of phantom experiments. The PEM imager was mounted on a standard Lorad biopsy table (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1287439
更新日期:2000-08-01 00:00:00
abstract::We are developing computerized methods for characterizing the bone texture pattern from digitized skeletal radiographs. For this method to be useful clinically, it must be able to distinguish between weak and strong bone under the range of exposure conditions potentially encountered in the clinical setting. In this st...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598858
更新日期:2000-01-01 00:00:00
abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3700166
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:Several treatment response metrics, such as RECIST and PERCIST, have been established for assessing individual solid tumors. However, metastatic prostate cancer poses a unique challenge to these metrics because bone lesions are often numerous and non-measureable. This study investigated the impact of using diff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735035
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. METHODS:The authors developed a computerized liver extraction scheme based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3395579
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:To investigate the accuracy of output factor measurements using a commercial (Exradin W1, SI) and a prototype, "in-house" developed, plastic scintillation dosimeter (PSD) in small photon fields. METHODS:Repetitive detector-specific output factor OFdet measurements were performed in water (parallel to the CAX) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12064
更新日期:2017-02-01 00:00:00
abstract::Atomic Energy of Canada Limited 60Co teletherapy units have adjustable collimator hinges to adapt to source diameters from 0.75 to 2.50 cm. Adjustment of the collimator hinge to the manfacturer's settings can cause a loss of radiation field flatness as high as 20% for large fields. The recommended settings appear to c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594170
更新日期:1975-03-01 00:00:00
abstract:PURPOSE:To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). METHODS:A total of 93 image sets including cus...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4959541
更新日期:2016-09-01 00:00:00
abstract::In this article, we report on the development of a simple and accurate method for quality assurance of electron beam output and energy. Aluminum disks of thicknesses d(max) or d50 of the particular electron energy are positioned sequentially over a parallel-plate ion chamber and the ratio of the two signals is compare...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1688040
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3242304
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12407
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:The outcome of radiotherapy can be further improved by combining irradiation with dose enhancers such as high-Z nanoparticles. Since 2004, spectacular results have been obtained when low-energy x-ray irradiations have been combined with nanoparticles. Recently, the same combination has been explored in hadron t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4934370
更新日期:2015-11-01 00:00:00
abstract:PURPOSE:The National Council for Radiation Protection and Measurement (NCRP) published estimates for the collective population dose and the mean effective dose to the population of the United States from medical imaging procedures for 1980/1982 and for 2006. The earlier report ignored the effective dose from radiothera...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906190
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3312435
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the authors had previously proposed a novel conversion of the energy-subtracted CT number to an electron density (ΔHU-ρe conversion), which provides a single linear relationship between ΔHU and ρe over a wide ρe range. The purpose ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4881327
更新日期:2014-07-01 00:00:00