Abstract:
PURPOSE:X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosis and treatment is studied using a novel approach for three-dimensional (3D) x-ray fluorescence mapping (XFM) of gold nanoparticle (GNP)-loaded objects in a physical phantom at the technical level. METHODS:All the theoretical analysis and experiments are conducted under the condition of using x-ray pencil beam and a compactly integrated x-ray spectrometer. The penetrability of the fluorescence x-rays from GNPs is first investigated by adopting a combination of BR12 with 70 mm/50 mm in thickness on the excitation/emission path to mimic the possible position of tumor goldin vivo. Then, a physical phantom made of BR12 is designed to translate in 3D space with three precise linear stages and subsequently the step by step XFM scanning is performed. The experimental technique named as background subtraction is applied to isolate the gold fluorescence from each spectrum obtained by the spectrometer. Afterwards, the attenuations of both the incident primary x-ray beam with energies beyond the gold K-edge energy (80.725 keV) and the isolated gold Kα fluorescence x-rays (65.99 -69.80 keV) acquired after background subtraction are well calibrated, and finally the unattenuated Kα fluorescence counts are used to realize mapping reconstruction and to describe the linear relationship between gold fluorescence counts and corresponding concentration of gold solutions. RESULTS:The penetration results show that the goldKα fluorescence x-rays have sufficient penetrability for this phantom study, and the reconstructed mapping results indicate that both the spatial distribution and relative concentration of GNPs within the designed BR12 phantom can be well identified and quantified. CONCLUSIONS:Although the XFM method in this investigation is still studied at the technical level and is not yet practical for routinein vivo mapping tasks with GNPs, the current penetrability measurements and phantom study strongly suggest the feasibility to establish and develop a 3D XFM system.
journal_name
Med Physjournal_title
Medical physicsauthors
Ren L,Wu D,Li Y,Wang G,Wu X,Liu Hdoi
10.1118/1.4863510subject
Has Abstractpub_date
2014-03-01 00:00:00pages
031902issue
3eissn
0094-2405issn
2473-4209journal_volume
41pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598111
更新日期:1997-12-01 00:00:00
abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3095777
更新日期:2009-04-01 00:00:00
abstract::Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in the early detection of lung cancer in radiographs and computed tomography (CT) images. In order to improve sensitivity for nodule detection, many researchers have employed a filter as a preprocessing step for enhancement of nodules. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1581411
更新日期:2003-08-01 00:00:00
abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1489044
更新日期:2002-07-01 00:00:00
abstract:PURPOSE:Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4794503
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:The aim of this work was to provide a novel description of how the radiotherapy community configures treatment planning system (TPS) radiation beam models for clinically used treatment machines. Here we describe the results of a survey of self-reported TPS beam modeling parameter values across different C-arm l...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13892
更新日期:2020-01-01 00:00:00
abstract::In order to determine accurately the relative x-ray intensities transmitted through the different steps of an aluminum stepwedge and incident on an image intensifier (II)-TV digital system, we used a 100-mm camera which was attached to the II output. The characteristic curves of an II-TV digital system, which relate t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595819
更新日期:1986-11-01 00:00:00
abstract:PURPOSE:Results about the feasibility of a method for quasi real time in vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based on correlations between the EPID signal and the dose on the beam central axis. Moreover, the γ-analysis of EPID images w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4875685
更新日期:2014-06-01 00:00:00
abstract:PURPOSE:Imaging biomarkers are crucial in managing treatment options for cancer patients. They are extremely powerful tools since they allow personalized treatment assessment early during therapy by using repeated imaging to detect and quantify tumor response. Currently, treatment response assessment from consecutive i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4764900
更新日期:2013-01-01 00:00:00
abstract::Performance characteristics sufficient to provide physical data base specific to the Siemen's Stabilipan 2 orthovoltage x-ray therapy machine are presented. Operating conditions covering the working range of the unit from 100 to 300 kVp are selected. Beam quality, output, the central axis depth dose, relative output f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596016
更新日期:1987-09-01 00:00:00
abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3081414
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4767763
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:The authors investigate the impact that incremental increases in the level of detail of patient-specific prior information have on image quality and the convergence behavior of an inversion algorithm in the context of near-field microwave breast imaging. A methodology is presented that uses image quality measur...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12585
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:To correlate the Cole relaxation frequencies obtained from measurements of the electrical properties of breast tissue to the presence or absence of cancer. METHODS:Four-lead impedance measurements were obtained on ex vivo specimens extracted during surgery from 187 volunteer patients. Data were acquired with a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4725172
更新日期:2012-07-01 00:00:00
abstract::For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high-energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane-parallel ionization c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596055
更新日期:1987-05-01 00:00:00
abstract::The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and un...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1751251
更新日期:2004-06-01 00:00:00
abstract::We believe that, for the purpose of evaluation and optimization of treatment plans, quasirandom sampling is superior to grid sampling and should be the method of choice. We believe it to be on average more efficient than grid sampling (i.e., more accurate for any given number of dose estimates) and, even more importan...
journal_title:Medical physics
pub_type: 评论,信件
doi:10.1118/1.597103
更新日期:1993-09-01 00:00:00
abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597228
更新日期:1994-12-01 00:00:00
abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594463
更新日期:1978-01-01 00:00:00
abstract::It is well-known that the edge effect produced by phase contrast imaging results in the edge enhancement of x-ray images and thereby sharpens those images. It has recently been reported that phase contrast imaging using practical x-ray tubes with small focal spots has improved image sharpness as observed in the phase ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1992087
更新日期:2005-08-01 00:00:00
abstract::An easy-to-use phantom has been constructed for checking the accuracy of a stereotactic computed tomography localization system. This phantom has been used on a commercially available stereotactic radiosurgery system. With this system, the phantom reference point, whose location is established by means of a precision ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597034
更新日期:1993-03-01 00:00:00
abstract:PURPOSE:To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. METHODS:A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3551999
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:Myocardial infarct (MI) may consist of an infarct core (IC) and a heterogeneous, semi-viable border zone (BZ). Patients with chronic MI in the left ventricular (LV) myocardium are at increased risk of developing ventricular arrhythmias, and may therefore qualify for implantable cardioverter defibrillator (ICD) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12840
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:To investigate the sensitivity of the plan-class specific correction factor to dose distributions in composite nonstandard field dosimetry. METHODS:A cylindrical water-filled PMMA phantom was constructed at the center of which reference absorbed dose could be measured. Ten different TomoTherapy(®)-based IMRT f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3669487
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:Variations during breast tissue development can influence later breast cancer risk. In particular, prolonged nulliparity increases risk. The authors used optical spectroscopy to compare breast tissue in 115 nulliparous women aged 31-40 (group 2) to 140 nulliparous women aged 18-21 (group 1), and also to 36 paro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3276737
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:Very fast Monte Carlo (MC) simulations of proton transport have been implemented recently on graphics processing units (GPUs). However, these MCs usually use simplified models for nonelastic proton-nucleus interactions. Our primary goal is to build a GPU-based proton transport MC with detailed modeling of elast...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921046
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:The purpose of the work is to describe a new algorithm for the automatic detection of implanted radioactive seeds within the prostate. The algorithm is based on the traditional Hough transform. A method of quality assurance is described as well as a quantitative phantom study to determine the accuracy of the al...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1778837
更新日期:2004-09-01 00:00:00
abstract::With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this st...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1897464
更新日期:2005-05-01 00:00:00
abstract::Deionized water is commonly used to couple microwave applicators to the patient surface in the administration of local hyperthermia. Profiles of the specific absorption rate (SAR) at 1-cm depth show that deionized water coupling significantly distorts the SAR distributions of the Clini-Therm 915-MHz 10 X 10 and 15 X 1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595881
更新日期:1986-05-01 00:00:00
abstract:PURPOSE:Deformable registration generally relies on the assumption that the sought spatial transformation is smooth. Yet, breathing motion involves sliding of the lung with respect to the chest wall, causing a discontinuity in the motion field, and the smoothness assumption can lead to poor matching accuracy. In respon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3679009
更新日期:2012-02-01 00:00:00