Dosimetric effects of contrast media for catheter-based intravascular brachytherapy.

Abstract:

:The purpose of this work is to calculate the dose perturbations due to the presence of iodine contrast media in catheter-based intravascular brachytherapy (IVBT). The EGSnrc Monte Carlo system was used to perform the calculation for the two most commonly used beta and gamma sources (90Sr and 192Ir as well as for a variety of monoenergetic photon and electron sources. Various contrast media with cylindrical-shell shapes were considered. The dose perturbations due to the presence of iodine contrast media were found to be significant for IVBT. In the region outside of the contrast media (usually the treatment target region for IVBT), the dose is generally increased for the gamma source, while it is decreased for the beta source. In the presence of a 1.0-mm-thick common clinical contrast medium, the dose enhancement can be as high as 30% for the 192Ir source, while the dose can be reduced by up to 25% for the 90Sr source. The dose enhancement region for the gamma source extends approximately 1.0 mm away from the contrast medium, while the dose reduction for the beta source affects the entire target region. The dose perturbation depends on (1) the volume (thickness) of the contrast medium, (2) the iodine concentration in contrast media, and (3) the type and energy of radioactive source. The dose effects due to the contrast medium as well as the differences between beta and gamma sources, revealed in this study, should be recognized and may be considered in the dose prescription for intravascular brachytherapy. These effects should also be taken into account in analyzing the treatment outcome for those IVBT clinical trials involving a contrast medium.

journal_name

Med Phys

journal_title

Medical physics

authors

Li XA

doi

10.1118/1.1367279

subject

Has Abstract

pub_date

2001-05-01 00:00:00

pages

757-63

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

28

pub_type

杂志文章
  • Fourier transform infrared imaging and small angle x-ray scattering as a combined biomolecular approach to diagnosis of breast cancer.

    abstract::Fourier transform infrared (FTIR) microspectroscopic imaging and small angle x-ray scattering (SAXS) were combined to investigate the supramolecular structure of collagen from 27 tissue sections from patients undergoing mastectomy, excisional biopsy, or mammoplasty. Both techniques were correlated by matching the scat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2890391

    authors: Ooi GJ,Fox J,Siu K,Lewis R,Bambery KR,McNaughton D,Wood BR

    更新日期:2008-05-01 00:00:00

  • The influence of phantom size on output, peak scatter factor, and percentage depth dose in large-field photon irradiation.

    abstract::Machine outputs, peak scatter factors, and central axis percentage depth dose distributions were measured for various phantom sizes in large radiation fields produced at extended distances by cobalt, 6-MV, and 10-MV photon beams. The results can be applied to practical total body irradiation procedures which usually i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595686

    authors: Podgorsak EB,Pla C,Evans MD,Pla M

    更新日期:1985-09-01 00:00:00

  • 4D rotational x-ray imaging of wrist joint dynamic motion.

    abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2000647

    authors: Carelsen B,Bakker NH,Strackee SD,Boon SN,Maas M,Sabczynski J,Grimbergen CA,Streekstra GJ

    更新日期:2005-09-01 00:00:00

  • Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.

    abstract::The computed tomography (CT) radiation dose to pediatric patients has received considerable attention recently. Moreover, it is important to be able to determine CT radiation doses for various patient sizes ranging from infants to large adults. The current AAPM protocol only measures CT radiation dose using a 16 cm ac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543149

    authors: Nickoloff EL,Dutta AK,Lu ZF

    更新日期:2003-03-01 00:00:00

  • A multiple detector array helical x-ray microtomography system for specimen imaging.

    abstract::An x-ray computed microtomography system for specimen and small animal imaging was built and tested. The system used seventeen 48-microm-wide detector arrays (a charge coupled device camera) and helical acquisition techniques. Images were acquired using 540 rays/view and 400 views/2pi. The modulation transfer function...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598662

    authors: Corrigan NM,Chavez AE,Wisner ER,Boone JM

    更新日期:1999-08-01 00:00:00

  • Inter- and intra-software reproducibility of computed tomography lung density measurements.

    abstract:PURPOSE:Multiple commercial, open-source, and academic software tools exist for objective quantification of lung density in computed tomography (CT) images. The purpose of this study was to evaluate the intersoftware reproducibility of CT lung density measurements. METHODS:Computed tomography images from 50 participan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14130

    authors: Kirby M,Hatt C,Obuchowski N,Humphries SM,Sieren J,Lynch DA,Fain SB,QIBA Lung Density Committee.

    更新日期:2020-07-01 00:00:00

  • SU-E-T-450: An Evaluation Study of Dose Calculation Algorithms for Stereotactic Body Radiation Therapy in Heterogeneous Phantom.

    abstract:PURPOSE:In Stereotactic body radiation therapy (SBRT) higher dose per fraction is delivered to patients and thus the need for an accurate dose computation is further elevated. However under such conditions of small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735539

    authors: Shosha M,Deiab N,Eldib A,Tohamy K

    更新日期:2012-06-01 00:00:00

  • Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: first patient studies.

    abstract:PURPOSE:Quantitative cone-beam CT (CBCT) imaging is on increasing demand for high-performance image guided radiation therapy (IGRT). However, the current CBCT has poor image qualities mainly due to scatter contamination. Its current clinical application is therefore limited to patient setup based on only bony structure...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3693050

    authors: Niu T,Al-Basheer A,Zhu L

    更新日期:2012-04-01 00:00:00

  • Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields.

    abstract::The purpose of this study is to develop a 4D inverse planning strategy capable of controlling the appearance of the implanted fiducial(s) in segmented IMRT fields for cine MV or combined MV/kV image-guided IMRT. This work is focused on enhancing the visibility of the implanted fiducial(s) in 4D IMRT inverse planning, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3121425

    authors: Ma Y,Lee L,Keshet O,Keall P,Xing L

    更新日期:2009-06-01 00:00:00

  • Off-axis beam quality change in linear accelerator x-ray beams.

    abstract::The effective energy of the x-ray beam from linear accelerators changes as a function of the position in the beam due to nonuniform filtration by the flattening filter. In this work, the transmittance through a water column was measured in good geometry and the beam quality characterized in units of HVL in water. Meas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594677

    authors: Hanson WF,Berkley LW,Peterson M

    更新日期:1980-03-01 00:00:00

  • Use of the fast Hartley transform for three-dimensional dose calculation in radionuclide therapy.

    abstract::Effective radioimmunotherapy may depend on a priori knowledge of the radiation absorbed dose distribution obtained by trace imaging activities administered to a patient before treatment. A new, fast, and effective treatment planning approach is developed to deal with a heterogeneous activity distribution. Calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598422

    authors: Erdi AK,Yorke ED,Loew MH,Erdi YE,Sarfaraz M,Wessels BW

    更新日期:1998-11-01 00:00:00

  • Detection and diagnosis of colitis on computed tomography using deep convolutional neural networks.

    abstract:PURPOSE:Colitis refers to inflammation of the inner lining of the colon that is frequently associated with infection and allergic reactions. In this paper, we propose deep convolutional neural networks methods for lesion-level colitis detection and a support vector machine (SVM) classifier for patient-level colitis dia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12399

    authors: Liu J,Wang D,Lu L,Wei Z,Kim L,Turkbey EB,Sahiner B,Petrick NA,Summers RM

    更新日期:2017-09-01 00:00:00

  • Accurate assessment and prediction of noise in clinical CT images.

    abstract:PURPOSE:The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. METHODS:The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938588

    authors: Tian X,Samei E

    更新日期:2016-01-01 00:00:00

  • Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model.

    abstract::A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598111

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-12-01 00:00:00

  • MR acoustic radiation force imaging: in vivo comparison to ultrasound motion tracking.

    abstract::MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3120289

    authors: Huang Y,Curiel L,Kukic A,Plewes DB,Chopra R,Hynynen K

    更新日期:2009-06-01 00:00:00

  • Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty.

    abstract::Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1791352

    authors: van Dijk E,Kolkman-Deurloo IK,Damen PM

    更新日期:2004-10-01 00:00:00

  • Improvement of off-axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system.

    abstract:PURPOSE:Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Frei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12805

    authors: Jeevanandam P,Agnew CE,Irvine DM,McGarry CK

    更新日期:2018-04-01 00:00:00

  • Analytical considerations of beam hardening in medical accelerator photon spectra.

    abstract::Beam hardening is a well-known phenomenon for therapeutic accelerator beams passing through matter in narrow beam geometry. This study assesses quantitatively the magnitude of beam hardening of therapeutic beams in water. A formal concept of beam hardening is proposed which is based on the decrease of the mean attenua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598704

    authors: Kleinschmidt C

    更新日期:1999-09-01 00:00:00

  • Response of an implantable MOSFET dosimeter to 192Ir HDR radiation.

    abstract::New in vivo dosimetry methods would be useful for clinical HDR brachytherapy. An implantable MOSFET Dose Verification System designed by Sicel Technologies, Inc. was examined for use with 192Ir HDR applications. This investigation demonstrated that varying the dose rate from 22 to 84 cGy/min did not change detector re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3013574

    authors: Fagerstrom JM,Micka JA,DeWerd LA

    更新日期:2008-12-01 00:00:00

  • Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism.

    abstract::As different types of radionuclides (e.g., 131Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2905356

    authors: Yue NJ

    更新日期:2008-06-01 00:00:00

  • Dosimetric properties of radiophotoluminescent glass detector in low-energy photon beams.

    abstract:PURPOSE:A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4747261

    authors: Kadoya N,Shimomura K,Kitou S,Shiota Y,Fujita Y,Dobashi S,Takeda K,Jingu K,Matsushita H,Namito Y,Ban S,Koyama S,Tabushi K

    更新日期:2012-10-01 00:00:00

  • Novel detector design for reducing intercell x-ray cross-talk in the variable resolution x-ray CT scanner: a Monte Carlo study.

    abstract:PURPOSE:The variable resolution x-ray (VRX) CT scanner provides substantial improvement in the spatial resolution by matching the scanner's field of view (FOV) to the size of the object being imaged. Intercell x-ray cross-talk is one of the most important factors limiting the spatial resolution of the VRX detector. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3555035

    authors: Arabi H,Asl AR,Ay MR,Zaidi H

    更新日期:2011-03-01 00:00:00

  • SU-E-I-16: Automated Liver Segmentation Method for CBCT Dataset by Probabilistic Atlas Construction.

    abstract:PURPOSE:The aiming is getting accurate liver contour structures automatically for following adaptive radiation therapy in daily CBCT images which is very low-contrast comparing the planning CT. METHODS:Probabilistic atlas is constructed by 50 intravenous contrast planning CT images by iterative affine registration pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734730

    authors: Li D,Li H,Yin Y,Chen J

    更新日期:2012-06-01 00:00:00

  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • Re-examining TG-142 recommendations in light of modern techniques for linear accelerator based radiosurgery.

    abstract:PURPOSE:The recent development of multifocal stereotactic radiosurgery (SRS) using a single isocenter volumetric modulated arc theory (VMAT) technique warrants a re-examination of the quality assurance (QA) tolerances for routine mechanical QA recommended by the American Association of Physicists in Medicine Task Group...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962471

    authors: Faught AM,Trager M,Yin FF,Kirkpatrick J,Adamson J

    更新日期:2016-10-01 00:00:00

  • Analysis of fractionation correction methodologies for multiple phase treatment plans in radiation therapy.

    abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792636

    authors: Mavroidis P,Ferreira BC,Papanikolaou N,Lopes Mdo C

    更新日期:2013-03-01 00:00:00

  • Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry.

    abstract:PURPOSE:To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. METHODS:Twenty volumetric images of patient breasts were acquired with a dedicated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4737025

    authors: Sechopoulos I,Bliznakova K,Qin X,Fei B,Feng SS

    更新日期:2012-08-01 00:00:00

  • Fourier-based approach to interpolation in single-slice helical computed tomography.

    abstract::It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal dire...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1350583

    authors: La Rivière PJ,Pan X

    更新日期:2001-03-01 00:00:00

  • Compressed sensing for longitudinal MRI: An adaptive-weighted approach.

    abstract:PURPOSE:Repeated brain MRI scans are performed in many clinical scenarios, such as follow up of patients with tumors and therapy response assessment. In this paper, the authors show an approach to utilize former scans of the patient for the acceleration of repeated MRI scans. METHODS:The proposed approach utilizes the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928148

    authors: Weizman L,Eldar YC,Ben Bashat D

    更新日期:2015-09-01 00:00:00

  • Calculation of the radiological depth.

    abstract::The concept of the radiological depth is central to all algorithms which calculate radiation dose in a heterogeneous medium. For a discrete heterogeneous medium, consisting of regions of inhomogeneity, the radiological depth is usually presented as the sum over segments of the product of the segment length and the inh...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595739

    authors: Siddon RL

    更新日期:1985-01-01 00:00:00