Abstract:
PURPOSE:The recent development of multifocal stereotactic radiosurgery (SRS) using a single isocenter volumetric modulated arc theory (VMAT) technique warrants a re-examination of the quality assurance (QA) tolerances for routine mechanical QA recommended by the American Association of Physicists in Medicine Task Group Report Number 142. Multifocal SRS can result in targets with small volumes being at a large off-axis distance from the treatment isocenter. Consequently, angular errors in the collimator, patient support assembly (PSA), or gantry could have an increased impact on target coverage. METHODS:The authors performed a retrospective analysis of dose deviations caused by systematic errors in PSA, collimator, and gantry angle at the tolerance level for routine linear accelerator QA as recommended by TG-142. Dosimetric deviations from multifocal SRS plans (N = 10) were compared to traditional single target SRS using dynamic conformal arcs (N = 10). The chief dosimetric quantities used in determining clinical impact were V100% and D99% of the individual planning target volumes and V12Gy of the healthy brain. RESULTS:Induced errors at tolerance levels showed the greatest change in multifocal SRS target coverage for collimator rotations (±1.0°) with the average changes to V100% and D99% being 5% and 6%, respectively, with maximum changes of 33% and 20%. A reduction in the induced error to half the TG-142 tolerance (±0.5°) demonstrated similar changes in coverage loss to traditional single target SRS assessed at the recommended tolerance level. The observed change in coverage for multifocal SRS was reduced for gantry errors (±1.0°) at 2% and 4.5% for V100% and D99%, respectively, with maximum changes of 18% and 12%. Minimal change in coverage was noted for errors in PSA rotation. CONCLUSIONS:This study indicates that institutions utilizing a single isocenter VMAT technique for multifocal disease should pay careful attention to the angular mechanical tolerances in designing a robust and complete QA program.
journal_name
Med Physjournal_title
Medical physicsauthors
Faught AM,Trager M,Yin FF,Kirkpatrick J,Adamson Jdoi
10.1118/1.4962471subject
Has Abstractpub_date
2016-10-01 00:00:00pages
5437issue
10eissn
0094-2405issn
2473-4209journal_volume
43pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-AR...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4865778
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4826166
更新日期:2013-11-01 00:00:00
abstract::Coherent-scatter computed tomography (CSCT) is a novel imaging method we are developing to produce cross-sectional images based on the low-angle (<10 degrees) scatter properties of tissue. At diagnostic energies, this scatter is primarily coherent with properties dependent upon the molecular structure of the scatterer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1493216
更新日期:2002-08-01 00:00:00
abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13276
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14676
更新日期:2020-12-23 00:00:00
abstract:PURPOSE:Two-dimensional ultrasound (2D US) imaging is commonly used for diagnostic and intraoperative guidance of interventional liver procedures; however, 2D US lacks volumetric information that may benefit interventional procedures. Over the past decade, three-dimensional ultrasound (3D US) has been developed to prov...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4824326
更新日期:2013-11-01 00:00:00
abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868780
更新日期:2008-04-01 00:00:00
abstract::The purpose of this work is to demonstrate a proof of feasibility of the application of a commercial prototype deformable model algorithm to the problem of delineation of anatomic structures on four-dimensional (4D) computed tomography (CT) image data sets. We acquired a 4D CT image data set of a patient's thorax that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1929207
更新日期:2005-07-01 00:00:00
abstract:PURPOSE:Most radiation therapy optimization problems can be formulated as an unconstrained problem and solved efficiently by quasi-Newton methods such as the Limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. However, several next generation planning techniques such as total variation regularization- b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12165
更新日期:2017-04-01 00:00:00
abstract::Intensity Modulated Arc Therapy (IMAT) is a rotational variant of Intensity Modulated Radiation Therapy (IMRT) that can be implemented with or without angular dose rate optimization. The purpose of this study is to determine the inter-relationship among arc range, Multi-Leaf Collimator (MLC) leaf positions and angular...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965975
更新日期:2008-07-01 00:00:00
abstract::In previous work it has been shown that a standard backpropagation neural network can be trained to reconstruct sections of single photon emission computed tomography (SPECT) images based on the planar image projections as inputs. In this study, it is demonstrated that an artificial neural network (ANN) trained on a s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597586
更新日期:1995-05-01 00:00:00
abstract:PURPOSE:Ultrasound-induced mild hyperthermia has advantages for noninvasive, localized and controlled drug delivery. In this study, a tissue-mimicking agarose-based phantom with a thermally sensitive indicator was developed for studying the spatial drug delivery profile using ultrasound-induced mild hyperthermia. METH...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813299
更新日期:2013-08-01 00:00:00
abstract::The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue whi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595768
更新日期:1985-05-01 00:00:00
abstract:PURPOSE:Mammographic density of glandular breast tissue has a masking effect that can reduce lesion detection accuracy and is also a strong risk factor for breast cancer. Therefore, accurate quantitative estimation of breast density is clinically important. In this study, we investigate experimentally the feasibility o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13031
更新日期:2018-06-03 00:00:00
abstract:PURPOSE:This work describes the performance characterization of a cone-beam CT-guided radiosurgery device, the Gamma Knife® Icon™. METHODS:The performance tests have been categorized into: (a) image quality and mechanical integrity; (b) image coregistration fidelity; (c) adaptive treatment delivery quality; (d) high d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13073
更新日期:2018-06-29 00:00:00
abstract::The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1414008
更新日期:2001-11-01 00:00:00
abstract:PURPOSE:The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a succe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3366252
更新日期:2010-04-01 00:00:00
abstract:PURPOSE:A multi-institution dosimetry intercomparison has been undertaken of prostate intensity modulated radiation therapy (IMRT) delivery. The dosimetry intercomparison was incorporated into the quality assurance for site credentialing for the Trans-Tasman Radiation Oncology Group Prostate Fractionated Irradiation Tr...
journal_title:Medical physics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1118/1.4808151
更新日期:2013-07-01 00:00:00
abstract:PURPOSE:To introduce a novel laser-based optical-CT scanner for the readout of three-dimensional (3D) radiation dosimeters. METHODS:The scanner employs a diode laser, a cylindrical lens, a motorized linear rail, a rotation stage, and a charge-coupled device camera. The scanner operates in a translate-rotate fashion an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3538924
更新日期:2011-02-01 00:00:00
abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1489044
更新日期:2002-07-01 00:00:00
abstract::A tomographic attachment was designed and developed that attaches to our existing simulator. The film tomograms obtained with the aid of this device exhibit very low geometrical distortion and good contrast and resolution for the objects used in this investigation. In addition, our results to date show that adjacent a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594662
更新日期:1980-03-01 00:00:00
abstract::Respiratory motion can produce misregistration errors between CT and PET images in cardiac PET/CT imaging. The objective of this study was to determine if manual registration of a single-phase end-expiration CT scan to the PET image would eliminate respiratory-induced artifacts. Listmode data from 71 cardiac PET patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965988
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:This study aims to investigate carotid plaque calcification (CPC) using two-dimensional (2D) and 3D ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequences and compare T1, T2*, water concentration, and bone mineral density (BMD) of CPC with those of cortical bone. METHODS:Twelve carotid plaque sp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4819944
更新日期:2013-10-01 00:00:00
abstract::We report our experimental results of measurements of x-ray attenuation coefficients of aqueous solutions of a light absorbing dye, indocyanine green, and an immunoadjuvant, glycated chitosan. In the treatment of metastatic tumors in rats using a novel laser immunotherapy these solutions were administered in situ. The...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598633
更新日期:1999-07-01 00:00:00
abstract::Photon point dose kernels and absorbed fractions were generated in water for the full photon emission spectrum of each radionuclide of interest in nuclear medicine, by simulating the transport of particles using Monte Carlo. The kernels were then fitted to a mathematical expression. Absorbed fractions for point source...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597670
更新日期:1996-05-01 00:00:00
abstract:PURPOSE:The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with the Linac's log file i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13579
更新日期:2019-07-01 00:00:00
abstract::The same calibration grade ionization chamber and electrometer were sequentially sent to all five currently AAPM Accredited Dosimetry Calibration Laboratories (ADCL). A Cesium-137 based check device was utilized to ensure chamber and electrometer factor constancy and showed a maximum deviation of 0.32% (typically less...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596880
更新日期:1992-01-01 00:00:00
abstract:PURPOSE:The pulse line ion accelerator (PLIA) is a low-cost accelerator concept originally designed to accelerate heavy ions. Our group has been investigating the use of PLIA to accelerate light ions and believe a multi-stage PLIA could be useful for short half-life PET isotope production. The goal of this work was to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13875
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:The authors describe the integration of optical imaging with a targeted small animal irradiator device, focusing on design, instrumentation, 2D to 3D image registration, 2D targeting, and the accuracy of recovering and mapping the optical signal to a 3D surface generated from the cone-beam computed tomography (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4894730
更新日期:2014-10-01 00:00:00
abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598354
更新日期:1998-09-01 00:00:00