SU-E-T-450: An Evaluation Study of Dose Calculation Algorithms for Stereotactic Body Radiation Therapy in Heterogeneous Phantom.

Abstract:

PURPOSE:In Stereotactic body radiation therapy (SBRT) higher dose per fraction is delivered to patients and thus the need for an accurate dose computation is further elevated. However under such conditions of small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation algorithm to accurately predict the dose, especially in the presence of tissue heterogeneities. Thus the aim of this study is to evaluate the performance of the algorithms implemented in our treatment planning system. METHODS:In this study different phantoms were designed to model the lung with a small tumor volume of sizes that are usually encountered in SBRT. Solid water and cork slabs were used in constructing the phantom body. Perspex pieces of different diameters were created to be inserted in precut holes in the cork to simulate the tumor. The various dose calculation algorithms that are implemented in our CMS XIO planning system were then used for dose calculation inside the target. RESULTS:A significant discrepancies between maximum, minimum and mean dose for PTV was found between Clarkson, FFT Convolution, Fast superposition and superposition algorithms in dose calculation for the lung tumor. The FFT Convolution and Clarkson algorithms have higher calculated minimum dose than that predicted by the superposition and the fast superposition algorithm. A percentage difference as high as 62.5% was obtained between Clarkson and the superposition algorithm in the estimated minimum dose. A percentage difference up to 13.4% was obtained between the FFT Convolution and the superposition algorithm for the estimated maximum dose. Superposition and fast superposition showed little discrepancies for maximum, minimum and mean dose for the PTV. CONCLUSION:It is very critical to address the accuracy of dose computation for SBRT as a significant dose overestimation can occur inside the target due to the heterogeneous geometries.

journal_name

Med Phys

journal_title

Medical physics

authors

Shosha M,Deiab N,Eldib A,Tohamy K

doi

10.1118/1.4735539

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3808

issue

6Part17

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • On the accuracy of techniques for obtaining the calibration coefficient N(K) of 192Ir HDR brachytherapy sources.

    abstract::The accuracy of interpolation or averaging procedures for obtaining the calibration coefficient N(K) for 192Ir high-dose-rate brachytherapy sources has been investigated using the EGSnrc Monte Carlo simulation system. It is shown that the widely used two-point averaging procedure of Goetsch et al. [Med. Phys. 18, 462 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2239198

    authors: Mainegra-Hing E,Rogers DW

    更新日期:2006-09-01 00:00:00

  • The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: characterization of two Cerenkov discrimination methods.

    abstract::New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2897966

    authors: Frelin AM,Fontbonne JM,Ban G,Colin J,Labalme M,Batalla A,Vela A,Boher P,Braud M,Leroux T

    更新日期:2008-05-01 00:00:00

  • Evaluation of inherent gray-level dynamic range in a digital image using the runs test and join-count statistics.

    abstract::The dynamic range of the gray level of a digital image is limited by the noise it contains. Two statistical methods called "runs test" and "join-count statistic" are used to measure the noise level in a digital image. A residual image is formed by subtracting an original image from its smoothed version. Theoretically,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597058

    authors: Chuang KS,Huang HK

    更新日期:1993-01-01 00:00:00

  • Feasibility of a simple method of hybrid collimation for megavoltage grid therapy.

    abstract:PURPOSE:Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4801902

    authors: Almendral P,Mancha PJ,Roberto D

    更新日期:2013-05-01 00:00:00

  • Radiologic validation of a fast neutron multileaf collimator.

    abstract::Teletherapy with high linear energy transfer radiations (LET), perhaps more than with low LET types, requires careful beam collimation to limit effects to normal structures. Intensity modulated techniques may also hold promise in this regard. Accordingly, a remote computer-controlled, high-resolution multileaf collima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2760026

    authors: Farr JB,Maughan RL,Yudelev M,Blosser E,Brandon J,Horste T,Forman JD

    更新日期:2007-09-01 00:00:00

  • SU-E-J-41: Fluoroscopy Based Adaptive Setup Approach for Thoracic Cancer IGRT.

    abstract:PURPOSE:To develop a fluoroscopy imaging based approach that can determine the magnitude and phase variation in respiratory motion against the treatment planning images in order to quantify the online patient setup deviation in thoracic cancer IGRT for the real time adaptive patient positionadjustment. METHODS:A numer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734876

    authors: Chen T,Qin S,Jabbour S,Park J,Haffty B,Yue N

    更新日期:2012-06-01 00:00:00

  • An accelerated threshold-based back-projection algorithm for compton camera image reconstruction.

    abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3519873

    authors: Mundy DW,Herman MG

    更新日期:2011-01-01 00:00:00

  • Oblique incidence for broad monoenergetic proton beams.

    abstract:PURPOSE:The depth dose of a monoenergetic broad parallel proton beam has been modeled in a number of ways, but evidently not yet for oblique incidence. The purpose of this investigation is to find an accurate analytic formula for this case, which can then be used to model the depth dose of a broad beam with an initial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3495969

    authors: Jette D,Yuan J,Chen W

    更新日期:2010-11-01 00:00:00

  • Assessment of the limiting spatial resolution of an MRI scanner by direct analysis of the edge spread function.

    abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3097633

    authors: Delakis I,Xanthis C,Kitney RI

    更新日期:2009-05-01 00:00:00

  • An alternative VMAT with prior knowledge about the type of leaf motion utilizing projection method for concave targets.

    abstract::The authors present an alternative approach to inverse planning optimization and apply it to volumetric modulated are therapy (VMAT) in one rotation with a prior knowledge about the type of leaf motions. The optimization is based on the projection theorem in inner product spaces. MLC motion is directly considered in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3173815

    authors: Hoegele W,Loeschel R,Zygmanski P

    更新日期:2009-08-01 00:00:00

  • Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4.

    abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939808

    authors: Ahmad SB,Sarfehnia A,Paudel MR,Kim A,Hissoiny S,Sahgal A,Keller B

    更新日期:2016-02-01 00:00:00

  • Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.

    abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13731

    authors: Niebler S,Schömer E,Tjaden H,Schwanecke U,Schulze R

    更新日期:2019-10-01 00:00:00

  • An automatic seed finder for brachytherapy CT postplans based on the Hough transform.

    abstract:PURPOSE:The purpose of the work is to describe a new algorithm for the automatic detection of implanted radioactive seeds within the prostate. The algorithm is based on the traditional Hough transform. A method of quality assurance is described as well as a quantitative phantom study to determine the accuracy of the al...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1778837

    authors: Holupka EJ,Meskell PM,Burdette EC,Kaplan ID

    更新日期:2004-09-01 00:00:00

  • Photon-beam subsource sensitivity to the initial electron-beam parameters.

    abstract::One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC sour...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1884385

    authors: Fix MK,Keall PJ,Siebers JV

    更新日期:2005-04-01 00:00:00

  • Patient specific optimization of the relation between CT-hounsfield units and proton stopping power with proton radiography.

    abstract::The purpose of this work is to show the feasibility of using in vivo proton radiography of a radiotherapy patient for the patient individual optimization of the calibration from CT-Hounsfield units to relative proton stopping power. Water equivalent tissue (WET) calibrated proton radiographs of a dog patient treated f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1833041

    authors: Schneider U,Pemler P,Besserer J,Pedroni E,Lomax A,Kaser-Hotz B

    更新日期:2005-01-01 00:00:00

  • Robust calculation of effective atomic numbers: the Auto-Z(eff) software.

    abstract:PURPOSE:The most appropriate method of evaluating the effective atomic number necessitates consideration of energy-dependent behavior. Previously, this required quite laborious calculation, which is why many scientists revert to over-simplistic power-law methods. The purpose of this work is to develop user-friendly sof...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3689810

    authors: Taylor ML,Smith RL,Dossing F,Franich RD

    更新日期:2012-04-01 00:00:00

  • Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs.

    abstract:PURPOSE:Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4950722

    authors: Zhang H,Wang L,Li L,Cai A,Hu G,Yan B

    更新日期:2016-06-01 00:00:00

  • Cumulative sum quality control for calibrated breast density measurements.

    abstract:PURPOSE:Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3250842

    authors: Heine JJ,Cao K,Beam C

    更新日期:2009-12-01 00:00:00

  • Treatment planning system and beam data validation for the ZAP-X: a novel self-shielded stereotactic radiosurgery system.

    abstract:PURPOSE:To evaluate the treatment planning system (TPS) performance of the ZAP-X stereotactic radiosurgery (SRS) system through nondosimetric, dosimetric, and end-to-end (E2E) tests. METHODS:A comprehensive set of TPS commissioning and validation tests were developed using published guidelines. Nondosimetric validatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14740

    authors: Srivastava SP,Jani SS,Pinnaduwage DS,Yan X,Rogers L,Barranco FD,Barani IJ,Sorensen S

    更新日期:2021-01-28 00:00:00

  • 2-Step IMAT and 2-Step IMRT: a geometrical approach.

    abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861161

    authors: Bratengeier K

    更新日期:2005-03-01 00:00:00

  • Systematic feasibility analysis of performing elastography using reduced dose CT lung image pairs.

    abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14112

    authors: Hasse K,Hsieh SS,O'Connell D,Stiehl B,Min Y,Neylon J,Low DA,Santhanam AP

    更新日期:2020-08-01 00:00:00

  • SU-C-218-06: Evaluation of a CT-Based, Semi-Automated Lung Mass Estimation Method Under Varying Acquisition Conditions.

    abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734654

    authors: Busse N,Erwin W,Pan T

    更新日期:2012-06-01 00:00:00

  • AAPM Task Group 329: Reference dose specification for dose calculations: Dose-to-water or dose-to-muscle?

    abstract::Linac calibration is done in water, but patients are comprised primarily of soft tissue. Conceptually, and specified in NRG/RTOG trials, dose should be reported as dose-to-muscle to describe the dose to the patient. Historically, the dose-to-water of the linac calibration was often converted to dose-to-muscle for pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13995

    authors: Kry SF,Feygelman V,Balter P,Knöös T,Charlie Ma CM,Snyder M,Tonner B,Vassiliev ON

    更新日期:2020-03-01 00:00:00

  • Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T.

    abstract:PURPOSE:To evaluate the performance and efficacy for intensity inhomogeneity correction of various sequences of the human brain in 7T MRI using the extended version of the unified segmentation algorithm. MATERIALS:Ten healthy volunteers were scanned with four different sequences (2D spin echo [SE], 3D fast SE, 2D fast...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4860954

    authors: Uwano I,Kudo K,Yamashita F,Goodwin J,Higuchi S,Ito K,Harada T,Ogawa A,Sasaki M

    更新日期:2014-02-01 00:00:00

  • X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays.

    abstract::We have measured the linearity, spatial resolution (MTF), noise (NPS), and signal-to-noise characteristics (DQE) of an electronic portal imaging device (EPID) based on an amorphous silicon flat-panel array. The array has a 128 x 128-pixel matrix and each pixel is 0.75 x 0.75 mm2 in dimension so the array covers an are...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598252

    authors: Munro P,Bouius DC

    更新日期:1998-05-01 00:00:00

  • Monte Carlo dose calculations for a new ovoid shield system for carcinoma of the uterine cervix.

    abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598459

    authors: Weeks KJ

    更新日期:1998-12-01 00:00:00

  • Evaluation of the interplay effect when using RapidArc to treat targets moving in the craniocaudal or right-left direction.

    abstract:PURPOSE:We have investigated the dosimetric errors caused by the interplay between the motions of the LINAC and the tumor during the delivery of a volume modulated arc therapy treatment. This includes the development of an IMRT QA technique, applied here to evaluate RapidArc plans of varying complexity. METHODS:An IMR...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3263614

    authors: Court L,Wagar M,Berbeco R,Reisner A,Winey B,Schofield D,Ionascu D,Allen AM,Popple R,Lingos T

    更新日期:2010-01-01 00:00:00

  • SU-E-T-236: Brachytherapy for Breast Cancer Patients with Implanted Pacemeker, Using Multi Lumen Partial Breast Applicator.

    abstract:PURPOSE:Discuss optimised Accelerated Partial Breast Irradiation (APBI) using a Strut-Adjused Volume Implant (SAVI) applicator for patients with implanted pacemeker, without overdosing or relocating the pacemaker. METHODS:A right breast cancer patient with an in situ pacemaker (Medtronic model ADDR01) on the right sid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735299

    authors: Jacob D,Strasser J

    更新日期:2012-06-01 00:00:00

  • A delivery quality assurance tool based on the actual leaf open times in tomotherapy.

    abstract:PURPOSE:To validate a delivery quality assurance (DQA) protocol for tomotherapy based on the measurement of the leaf open times (LOTs). In addition, to show the correlation between the mean relative LOT discrepancy and the dose deviation in the planning target volume (PTV). MATERIALS AND METHODS:We used a LOT measurem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14348

    authors: Schopfer M,Bochud FO,Bourhis J,Moeckli R

    更新日期:2020-09-01 00:00:00

  • Poster - Thurs Eve-32: Dose errors related to the treatment couch.

    abstract::Modern radiotherapy linacs often use carbon fibre for their couch tops due to its radio translucent properties. Beam attenuation by the couches is often ignored during planning and MU calculation. This work examines beam attenuation and loss of "skin sparing" (dose build up region) when various photon beams transit ei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965951

    authors: Niedbala M,Nyiri B,Gerig L

    更新日期:2008-07-01 00:00:00