A delivery quality assurance tool based on the actual leaf open times in tomotherapy.

Abstract:

PURPOSE:To validate a delivery quality assurance (DQA) protocol for tomotherapy based on the measurement of the leaf open times (LOTs). In addition, to show the correlation between the mean relative LOT discrepancy and the dose deviation in the planning target volume (PTV). MATERIALS AND METHODS:We used a LOT measurement algorithm presented in a previous work on our two tomotherapy treatment units (TOMO1 and TOMO2). We generated TomoPhant plans with intentional random LOT discrepancies following Gaussian distributions of -6%, -4%, -2%, 2%, 4%, and 6%. We irradiated them on the Cheese Phantom with two ion chambers and collected the raw data on both our treatment units. Using the raw data, we measured the actual LOTs and verified that the induced discrepancies were highlightable. Then, we calculated the actual dose using Accuray's standalone dose calculator and verified that the calculated dose agreed with the ion chamber measurement. We randomly chose 60 clinical treatment plans, delivered them in air, and collected the raw detector data. We measured the actual LOTs from the raw data and calculated the corresponding dose distributions using Accuray's standalone dose calculator. We assessed the Pearson coefficient correlation of the deviation between expected and actual dose in the PTV (a) with the mean relative LOT discrepancy and (b) with the γ-index pass rate for different tolerances. RESULTS:The mean relative discrepancy between actual (measured by the algorithm) and expected LOTs on the modified TomoPhant plans was 1.10 ± 0.05% on TOMO1 and 0.02 ± 0.03% on TOMO2, respectively. The agreement between measured and calculated dose was 0.2 ± 0.3% on TOMO1 and 0.1 ± 0.3% on TOMO2, respectively. On clinical plans, the means of the relative LOT discrepancies ranged from -3.0 % to 1.4%. The dose deviation in the PTVs ranged from -1.6% to 2.4%. The Pearson coefficient correlation between the mean relative LOT discrepancy and the dose deviation in the PTV was 0.76 (P ≈ 10-15 ) on TOMO1 and 0.65 (P ≈ 10-10 ) on TOMO2, respectively. There was no correlation between the γ-index pass rate and the dose deviation in the PTV. CONCLUSION:The method made it possible to measure and to correctly highlight the LOT discrepancies on the TomoPhant plans. The dose subsequently calculated was accurate. On clinical plans, the mean LOT discrepancy correlated with the dose deviation in the PTV. This makes the mean LOT discrepancy a handy indicator of the plan quality.

journal_name

Med Phys

journal_title

Medical physics

authors

Schopfer M,Bochud FO,Bourhis J,Moeckli R

doi

10.1002/mp.14348

subject

Has Abstract

pub_date

2020-09-01 00:00:00

pages

3845-3851

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring.

    abstract::Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved ...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4935869

    authors: Parodi K

    更新日期:2015-12-01 00:00:00

  • Use of capillary optics as a beam intensifier for a Compton x-ray source.

    abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597218

    authors: Tompkins PA,Abreu CC,Carroll FE,Xiao QF,MacDonald CA

    更新日期:1994-11-01 00:00:00

  • 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification.

    abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2936229

    authors: Stancanello J,Muacevic A,Sebastiano F,Modugno N,Cerveri P,Ferrigno G,Uggeri F,Romanelli P

    更新日期:2008-07-01 00:00:00

  • Physics process level discrimination of detections for GATE: assessment of contamination in SPECT and spurious activity in PET.

    abstract::The GEANT4 application for tomographic emission (GATE) is one of the most detailed Monte Carlo simulation tools for SPECT and PET. It allows for realistic phantoms, complex decay schemes, and a large variety of detector geometries. However, only a fraction of the information in each particle history is available for p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3078045

    authors: De Beenhouwer J,Staelens S,Vandenberghe S,Verhaeghe J,Van Holen R,Rault E,Lemahieu I

    更新日期:2009-04-01 00:00:00

  • Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4.

    abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939808

    authors: Ahmad SB,Sarfehnia A,Paudel MR,Kim A,Hissoiny S,Sahgal A,Keller B

    更新日期:2016-02-01 00:00:00

  • Characteristics and quality assurance of a dedicated open 0.23 T MRI for radiation therapy simulation.

    abstract::A commercially available open MRI unit is under routine use for radiation therapy simulation. The effects of a gradient distortion correction (GDC) program used to post process the images were assessed by comparison with the known geometry of a phantom. The GDC reduced the magnitude of the distortions at the periphery...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513991

    authors: Mah D,Steckner M,Palacio E,Mitra R,Richardson T,Hanks GE

    更新日期:2002-11-01 00:00:00

  • Dosimetric characterization of Ir-192 LDR elongated sources.

    abstract::Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2839102

    authors: van der Laarse R,Granero D,Pérez-Calatayud J,Meigooni AS,Ballester F

    更新日期:2008-03-01 00:00:00

  • Characterization of fragmented heavy-ion beams using a three-stage telescope detector: measurements of 670-MeV/amu 20Ne beams.

    abstract::Measurements of a 670-MeV/amu 20Ne beam at the Lawrence Berkeley Laboratory Bevalac heavy-ion accelerator with various thicknesses of water absorber were obtained with the BERKLET. The BERKLET, a simple three-stage solid-state telescope detector, has been described previously. This instrument measures the linear energ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596536

    authors: Llacer J,Schmidt JB,Tobias CA

    更新日期:1990-03-01 00:00:00

  • Characterizing the reflectivity of handheld display devices.

    abstract:PURPOSE:With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4887813

    authors: Liu P,Badano A

    更新日期:2014-08-01 00:00:00

  • Investigation of intensity-modulated radiotherapy optimization with gEUD-based objectives by means of simulated annealing.

    abstract::Inverse treatment planning of intensity-modulated radiation therapy (IMRT) is complicated by several sources of error, which can cause deviations of optimized plans from the true optimal solution. These errors include the systematic and convergence error, the local minima error, and the optimizer convergence error. We...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2896070

    authors: Hartmann M,Bogner L

    更新日期:2008-05-01 00:00:00

  • Feature-based multibody rigid registration of CT and ultrasound images of lumbar spine.

    abstract:PURPOSE:Fusion of intraprocedure ultrasound and preprocedure CT data is proposed for guidance in percutaneous spinal injections, a common procedure for pain management. CT scan of the lumbar spine is usually collected in a supine position, whereas spinal injections are performed in prone or sitting positions. This lead...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4711753

    authors: Rasoulian A,Abolmaesumi P,Mousavi P

    更新日期:2012-06-01 00:00:00

  • The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator.

    abstract::The geometric accuracy and precision of an image-guided treatment system were assessed. Image guidance is performed using an x-ray volume imaging (XVI) system integrated with a linear accelerator and treatment planning system. Using an amorphous silicon detector and x-ray tube, volumetric computed tomography images ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2143141

    authors: Sharpe MB,Moseley DJ,Purdie TG,Islam M,Siewerdsen JH,Jaffray DA

    更新日期:2006-01-01 00:00:00

  • Sci-Thur AM: Planning - 10: Improved dosimetric accuracy for patient specific quality assurance using a dual-detector measurement method for cyberknife output factors.

    abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740095

    authors: Vandervoort E,La Russa D,Ploquin N,Kadir IAE,Szanto J

    更新日期:2012-07-01 00:00:00

  • Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma.

    abstract:PURPOSE:Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as inter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948999

    authors: Guo F,Svenningsen S,Eddy RL,Capaldi DPI,Sheikh K,Fenster A,Parraga G

    更新日期:2016-06-01 00:00:00

  • Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

    abstract::The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric effects were studied considering the breathing pattern of three patients monitored during the course of their treatment ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2821704

    authors: Seco J,Sharp GC,Wu Z,Gierga D,Buettner F,Paganetti H

    更新日期:2008-01-01 00:00:00

  • Electron backscatter corrections for parallel-plate chambers.

    abstract::The wall of an ionization chamber is commonly assumed to have a negligible effect on chamber response in electron beams. For cylindrical chambers with thin walls this assumption is valid. However, parallel-plate chambers commonly possess large mechanical supports which may affect chamber response in a manner not accou...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596165

    authors: Hunt MA,Kutcher GJ,Buffa A

    更新日期:1988-01-01 00:00:00

  • Monte Carlo and experimental dosimetry of an 1251 brachytherapy seed.

    abstract::We have performed a comprehensive dosimetric characterization of the Oncura model 6711 125I seed using both experimental [LiF thermoluminscent dosimetry (TLD)] and theoretical (Monte Carlo photon transport) methods. In addition to determining the dosimetric parameters of the 6711, this report quantified: (1) the angul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2388158

    authors: Dolan J,Lia Z,Williamson JF

    更新日期:2006-12-01 00:00:00

  • A methodology to determine margins by EPID measurements of patient setup variation and motion as applied to immobilization devices.

    abstract::Assessment of clinic and site specific margins are essential for the effective use of three-dimensional and intensity modulated radiation therapy. An electronic portal imaging device (EPID) based methodology is introduced which allows individual and population based CTV-to-PTV margins to be determined and compared wit...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1800712

    authors: Prisciandaro JI,Frechette CM,Herman MG,Brown PD,Garces YI,Foote RL

    更新日期:2004-11-01 00:00:00

  • Automated segmentation of a motion mask to preserve sliding motion in deformable registration of thoracic CT.

    abstract:PURPOSE:Deformable registration generally relies on the assumption that the sought spatial transformation is smooth. Yet, breathing motion involves sliding of the lung with respect to the chest wall, causing a discontinuity in the motion field, and the smoothness assumption can lead to poor matching accuracy. In respon...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3679009

    authors: Vandemeulebroucke J,Bernard O,Rit S,Kybic J,Clarysse P,Sarrut D

    更新日期:2012-02-01 00:00:00

  • Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning.

    abstract::The purpose of this study is to perform a clinical evaluation of the first commercial (MDS Nordion, now Nucletron) treatment planning system for electron beams incorporating Monte Carlo dose calculation module. This software implements Kawrakow's VMC++ voxel-based Monte Carlo calculation algorithm. The accuracy of the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1633105

    authors: Cygler JE,Daskalov GM,Chan GH,Ding GX

    更新日期:2004-01-01 00:00:00

  • Computational modeling of 915 MHz microwave ablation: Comparative assessment of temperature-dependent tissue dielectric models.

    abstract:PURPOSE:The objective of this study is to develop a computational model for simulating 915 MHz microwave ablation (MWA), and verify the simulation predictions of transient temperature profiles against experimental measurements. Due to the limited experimental data characterizing temperature-dependent changes of tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12359

    authors: Deshazer G,Hagmann M,Merck D,Sebek J,Moore KB,Prakash P

    更新日期:2017-09-01 00:00:00

  • Validation of deformable registration in head and neck cancer using analysis of variance.

    abstract:PURPOSE:Deformable image registration (DIR) is often validated based on a distance-to-agreement (DTA) criterion of automatically propagated anatomical landmarks that were manually identified. Due to human observer variability, however, the performance of the registration method is diluted. The purpose of this study was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4760990

    authors: Mencarelli A,van Beek S,van Kranen S,Rasch C,van Herk M,Sonke JJ

    更新日期:2012-11-01 00:00:00

  • Estimation of organ doses from kilovoltage cone-beam CT imaging used during radiotherapy patient position verification.

    abstract:PURPOSE:The purpose of this study was to develop a practical method for estimating organ doses from kilovoltage cone-beam CT (CBCT) that can be performed with readily available phantoms and dosimeters. The accuracy of organ dose estimates made using the ImPACT patient dose calculator was also evaluated. METHODS:A 100 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3476459

    authors: Hyer DE,Hintenlang DE

    更新日期:2010-09-01 00:00:00

  • Uncertainties in IMRT dosimetry.

    abstract:PURPOSE:The purpose of this study is to investigate some characteristics of the beam delivery system and their effects on the dose distribution of intensity-modulated radiation therapy (IMRT) and the results of patient-specific IMRT quality assurance (QA). These characteristics include the accelerator source distributi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3413997

    authors: Li JS,Lin T,Chen L,Price RA Jr,Ma CM

    更新日期:2010-06-01 00:00:00

  • Variability of tumor area measurements for response assessment in malignant pleural mesothelioma.

    abstract:PURPOSE:The measurement of malignant pleural mesothelioma is critical to the assessment of tumor response to therapy. Current response assessment standards utilize summed linear measurements acquired on three computed tomography (CT) sections. The purpose of this study was to evaluate manual area measurements as an alt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810940

    authors: Labby ZE,Straus C,Caligiuri P,MacMahon H,Li P,Funaki A,Kindler HL,Armato SG 3rd

    更新日期:2013-08-01 00:00:00

  • Direct aperture deformation: an interfraction image guidance strategy.

    abstract::A new scheme, called direct aperture deformation (DAD), for online correction of interfraction geometric uncertainties under volumetric imaging guidance is presented. Using deformable image registration, the three-dimensional geometric transformation matrix can be derived that associates the planning image set and the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2374675

    authors: Feng Y,Castro-Pareja C,Shekhar R,Yu C

    更新日期:2006-12-01 00:00:00

  • Partial volume segmentation of brain magnetic resonance images based on maximum a posteriori probability.

    abstract::Noise, partial volume (PV) effect, and image-intensity inhomogeneity render a challenging task for segmentation of brain magnetic resonance (MR) images. Most of the current MR image segmentation methods focus on only one or two of the above-mentioned effects. The objective of this paper is to propose a unified framewo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1944912

    authors: Li X,Li L,Lu H,Liang Z

    更新日期:2005-07-01 00:00:00

  • False-positive reduction in CAD mass detection using a competitive classification strategy.

    abstract::High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344203

    authors: Li L,Zheng Y,Zhang L,Clark RA

    更新日期:2001-02-01 00:00:00

  • Measured electron energy and angular distributions from clinical accelerators.

    abstract::Electron energy spectra and angular distributions, including angular spreads, were measured using magnetic spectrometer techniques, at isocenter, for two clinical linear accelerators: one scanning beam machine, which achieves field flatness by scanning a pencil beam over the desired field at the patient plane, and one...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597817

    authors: Deasy JO,Almond PR,McEllistrem MT

    更新日期:1996-05-01 00:00:00

  • An automatic seed finder for brachytherapy CT postplans based on the Hough transform.

    abstract:PURPOSE:The purpose of the work is to describe a new algorithm for the automatic detection of implanted radioactive seeds within the prostate. The algorithm is based on the traditional Hough transform. A method of quality assurance is described as well as a quantitative phantom study to determine the accuracy of the al...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1778837

    authors: Holupka EJ,Meskell PM,Burdette EC,Kaplan ID

    更新日期:2004-09-01 00:00:00