Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning.

Abstract:

:The purpose of this study is to perform a clinical evaluation of the first commercial (MDS Nordion, now Nucletron) treatment planning system for electron beams incorporating Monte Carlo dose calculation module. This software implements Kawrakow's VMC++ voxel-based Monte Carlo calculation algorithm. The accuracy of the dose distribution calculations is evaluated by direct comparisons with extensive sets of measured data in homogeneous and heterogeneous phantoms at different source-to-surface distances (SSDs) and gantry angles. We also verify the accuracy of the Monte Carlo module for monitor unit calculations in comparison with independent hand calculations for homogeneous water phantom at two different SSDs. All electron beams in the range 6-20 MeV are from a Siemens KD-2 linear accelerator. We used 10,000 or 50,000 histories/cm2 in our Monte Carlo calculations, which led to about 2.5% and 1% relative standard error of the mean of the calculated dose. The dose calculation time depends on the number of histories, the number of voxels used to map the patient anatomy, the field size, and the beam energy. The typical run time of the Monte Carlo calculations (10,000 histories/cm2) is 1.02 min on a 2.2 GHz Pentium 4 Xeon computer for a 9 MeV beam, 10 x 10 cm2 field size, incident on the phantom 15 x 15 x 10 cm3 consisting of 31 CT slices and voxels size of 3 x 3 x 3 mm3 (total of 486,720 voxels). We find good agreement (discrepancies smaller than 5%) for most of the tested dose distributions. We also find excellent agreement (discrepancies of 2.5% or less) for the monitor unit calculations relative to the independent manual calculations. The accuracy of monitor unit calculations does not depend on the SSD used, which allows the use of one virtual machine for each beam energy for all arbitrary SSDs. In some cases the test results are found to be sensitive to the voxel size applied such that bigger systematic errors (>5%) occur when large voxel sizes interfere with the extensions of heterogeneities or dose gradients because of differences between the experimental and calculated geometries. Therefore, user control over voxelization is important for high accuracy electron dose calculations.

journal_name

Med Phys

journal_title

Medical physics

authors

Cygler JE,Daskalov GM,Chan GH,Ding GX

doi

10.1118/1.1633105

subject

Has Abstract

pub_date

2004-01-01 00:00:00

pages

142-53

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

31

pub_type

杂志文章
  • Primary dose in photon beams with lateral electron disequilibrium.

    abstract::It is shown that in narrow monoenergetic photon beams under conditions of lateral electron disequilibrium, primary absorbed dose P(r) is a simple function of beam radius r: P(r) = P lambda.(1 - e(-gamma.r)), where P lambda is the primary dose in broad beams for which complete lateral electron equilibrium exists, and g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596741

    authors: Nizin PS,Chang XS

    更新日期:1991-07-01 00:00:00

  • A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac.

    abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773883

    authors: Gete E,Duzenli C,Milette MP,Mestrovic A,Hyde D,Bergman AM,Teke T

    更新日期:2013-02-01 00:00:00

  • Ideal-observer detectability in photon-counting differential phase-contrast imaging using a linear-systems approach.

    abstract:PURPOSE:To provide a cascaded-systems framework based on the noise-power spectrum (NPS), modulation transfer function (MTF), and noise-equivalent number of quanta (NEQ) for quantitative evaluation of differential phase-contrast imaging (Talbot interferometry) in relation to conventional absorption contrast under equal-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4739195

    authors: Fredenberg E,Danielsson M,Stayman JW,Siewerdsen JH,Aslund M

    更新日期:2012-09-01 00:00:00

  • Design and performance of a compact and stationary microSPECT system.

    abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822621

    authors: Van Holen R,Vandeghinste B,Deprez K,Vandenberghe S

    更新日期:2013-11-01 00:00:00

  • Delivery validation of an automated modulated electron radiotherapy plan.

    abstract:PURPOSE:Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876297

    authors: Connell T,Alexander A,Papaconstadopoulos P,Serban M,Devic S,Seuntjens J

    更新日期:2014-06-01 00:00:00

  • MR acoustic radiation force imaging: in vivo comparison to ultrasound motion tracking.

    abstract::MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3120289

    authors: Huang Y,Curiel L,Kukic A,Plewes DB,Chopra R,Hynynen K

    更新日期:2009-06-01 00:00:00

  • The accuracy of SPECT brain activation images: propagation of registration errors.

    abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597228

    authors: Sychra JJ,Pavel DG,Chen Y,Jani A

    更新日期:1994-12-01 00:00:00

  • Deconvolution techniques for removing the effects of chemical shift in 19F nuclear magnetic resonance imaging of perfluorocarbon compounds.

    abstract::Nuclear magnetic resonance (NMR) imaging of perfluorocarbon (PFC) emulsions and neat liquids has shown potential for in vivo oxygen imaging in blood and organ tissue. PFC compounds exhibit complicated NMR spectra caused by chemical shifts and spin-spin couplings which can lead to artifacts and degraded spatial resolut...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595960

    authors: Busse LJ,Thomas SR,Pratt RG,Clark LC Jr,Ackerman JL,Samaratunga RC,Hoffmann RE

    更新日期:1986-07-01 00:00:00

  • Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator.

    abstract:PURPOSE:Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4946815

    authors: Hansen R,Ravkilde T,Worm ES,Toftegaard J,Grau C,Macek K,Poulsen PR

    更新日期:2016-05-01 00:00:00

  • Experimental assessment of microwave ablation computational modeling with MR thermometry.

    abstract:PURPOSE:Computational models are widely used during the design and characterization of microwave ablation (MWA) devices, and have been proposed for pretreatment planning. Our objective was to assess three-dimensional (3D) transient temperature and ablation profiles predicted by MWA computational models with temperature...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14318

    authors: Faridi P,Keselman P,Fallahi H,Prakash P

    更新日期:2020-09-01 00:00:00

  • Design and evaluation of a HDR skin applicator with flattening filter.

    abstract::The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2825622

    authors: Granero D,Pérez-Calatayud J,Gimeno J,Ballester F,Casal E,Crispín V,van der Laarse R

    更新日期:2008-02-01 00:00:00

  • Uncertainties in IMRT dosimetry.

    abstract:PURPOSE:The purpose of this study is to investigate some characteristics of the beam delivery system and their effects on the dose distribution of intensity-modulated radiation therapy (IMRT) and the results of patient-specific IMRT quality assurance (QA). These characteristics include the accelerator source distributi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3413997

    authors: Li JS,Lin T,Chen L,Price RA Jr,Ma CM

    更新日期:2010-06-01 00:00:00

  • Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data.

    abstract::Receiver operating characteristic (ROC) methodology is widely used in evaluating medical imaging modalities. While appropriate in some cases, it has several drawbacks when the detection task, e.g., nodule detection, involves localizing the abnormality. Free-response receiver operating characteristic (FROC) methodology...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596358

    authors: Chakraborty DP

    更新日期:1989-07-01 00:00:00

  • On the constancy in composition of polystyrene and polymethylmethacrylate plastics.

    abstract::Variations in the atomic composition, and mass and electron densities of polystyrene and polymethylmethacrylate (PMM) plastics were assessed from experimentally determined mass attenuation coefficients for 125I and 137Cs gamma rays. The means and standard deviations in the mass densities of 16 samples of PMM and 10 sa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594528

    authors: Schulz RJ,Nath R

    更新日期:1979-03-01 00:00:00

  • Determining the energy spectrum of clinical linear accelerator using an optimized photon beam transmission protocol.

    abstract:PURPOSE:The complex beam delivery techniques for patient treatment using a clinical linear accelerator (linac) may result in variations in the photon spectra, which can lead to dosimetric differences in patients that cannot be accounted for by current treatment planning systems (TPSs). Therefore, precise knowledge of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13569

    authors: Choi HJ,Park H,Yi CY,Kim BC,Shin WG,Min CH

    更新日期:2019-07-01 00:00:00

  • Power deposition in whole-body NMR imaging.

    abstract::The surface radio frequency (rf) power absorption in human head and torso nuclear magnetic resonance (NMR) imaging experiments is estimated. The results are expressed as a function of the NMR frequency, the rf pulse length, and the pulse duty cycle, which are varied over six orders of magnitude for general applicabili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595000

    authors: Bottomley PA,Edelstein WA

    更新日期:1981-07-01 00:00:00

  • First study of on-treatment volumetric imaging during respiratory gated VMAT.

    abstract:PURPOSE:To obtain on-treatment volumetric patient anatomy during respiratory gated volumetric modulated arc therapy (VMAT). METHODS:On-board imaging device integrated with Linacs offers a viable tool for obtaining patient anatomy during radiation treatment delivery. In this study, the authors acquired beam-level kV im...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4794925

    authors: Choi K,Xing L,Koong A,Li R

    更新日期:2013-04-01 00:00:00

  • The influence of field strength and different clinical breast MRI protocols on the outcome of texture analysis using foam phantoms.

    abstract:PURPOSE:Texture analysis (TA) has proved to be useful to distinguish different tissues and disease states using magnetic resonance imaging (MRI). TA has been successfully applied clinically to improve identification of abnormalities in the brain, liver, and bone and, more recently, has been used to enhance the specific...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3622605

    authors: Waugh SA,Lerski RA,Bidaut L,Thompson AM

    更新日期:2011-09-01 00:00:00

  • An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field.

    abstract::Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388219

    authors: Olivo A,Arfelli F,Cantatore G,Longo R,Menk RH,Pani S,Prest M,Poropat P,Rigon L,Tromba G,Vallazza E,Castelli E

    更新日期:2001-08-01 00:00:00

  • Comparative dosimetry of diode and diamond detectors in electron beams for intraoperative radiation therapy.

    abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1315317

    authors: Björk P,Knöös T,Nilsson P

    更新日期:2000-11-01 00:00:00

  • Development of the open-source dose calculation and optimization toolkit matRad.

    abstract:PURPOSE:We report on the development of the open-source cross-platform radiation treatment planning toolkit matRad and its comparison against validated treatment planning systems. The toolkit enables three-dimensional intensity-modulated radiation therapy treatment planning for photons, scanned protons and scanned carb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12251

    authors: Wieser HP,Cisternas E,Wahl N,Ulrich S,Stadler A,Mescher H,Müller LR,Klinge T,Gabrys H,Burigo L,Mairani A,Ecker S,Ackermann B,Ellerbrock M,Parodi K,Jäkel O,Bangert M

    更新日期:2017-06-01 00:00:00

  • Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study.

    abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4747342

    authors: Sieren JP,Newell JD,Judy PF,Lynch DA,Chan KS,Guo J,Hoffman EA

    更新日期:2012-09-01 00:00:00

  • Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images.

    abstract::Registration of single slices from FluoroCT, CineMR, or interventional magnetic resonance imaging to three dimensional (3D) volumes is a special aspect of the two-dimensional (2D)/3D registration problem. Rather than digitally rendered radiographs (DRR), single 2D slice images obtained during interventional procedures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2401661

    authors: Birkfellner W,Figl M,Kettenbach J,Hummel J,Homolka P,Schernthaner R,Nau T,Bergmann H

    更新日期:2007-01-01 00:00:00

  • Efficient low-dose CT artifact mitigation using an artifact-matched prior scan.

    abstract:PURPOSE:Low-dose CT has attracted increasing attention due to growing concerns about radiation exposure in medical scans. However, the frugal use of x-ray radiation inevitably reduces the quality of the CT images, introducing artifacts such as noise and streaks which make the reconstructed images difficult to read in c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736528

    authors: Xu W,Mueller K

    更新日期:2012-08-01 00:00:00

  • Accurate measurement of characteristic curves of II-TV digital systems by use of aluminum stepwedge technique.

    abstract::In order to determine accurately the relative x-ray intensities transmitted through the different steps of an aluminum stepwedge and incident on an image intensifier (II)-TV digital system, we used a 100-mm camera which was attached to the II output. The characteristic curves of an II-TV digital system, which relate t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595819

    authors: Fujita H,Doi K

    更新日期:1986-11-01 00:00:00

  • Poster - Thur Eve - 04: Online review of beam output and profile constancy using statistical process control.

    abstract::The objective of this work was to create a comprehensive online tool to evaluate and review the performance of quality assurance measurements that assess beam output and profile constancy as soon as they are acquired using statistical process control. As part of routine quality assurance: output, flatness and symmetry...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740111

    authors: Chmielewski R,Abbas A,Yeung I

    更新日期:2012-07-01 00:00:00

  • A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention.

    abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148834

    authors: Yan K,Li L,Joseph J,Rubens DR,Messing EM,Liao L,Yu Y

    更新日期:2009-07-01 00:00:00

  • Monte Carlo and analytical model predictions of leakage neutron exposures from passively scattered proton therapy.

    abstract:PURPOSE:Stray neutron radiation is of concern after radiation therapy, especially in children, because of the high risk it might carry for secondary cancers. Several previous studies predicted the stray neutron exposure from proton therapy, mostly using Monte Carlo simulations. Promising attempts to develop analytical ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4829512

    authors: Pérez-Andújar A,Zhang R,Newhauser W

    更新日期:2013-12-01 00:00:00

  • Normalized dose data for upper gastrointestinal tract contrast studies performed to infants.

    abstract::The aim of the current study was to (a) provide normalized dose data for the estimation of the radiation dose from upper gastrointestinal tract contrast (UGIC) studies carried out to infants and (b) estimate the average patient dose and risks associated with radiation from UGIC examinations performed in our institutio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2181297

    authors: Damilakis J,Stratakis J,Raissaki M,Perisinakis K,Kourbetis N,Gourtsoyiannis N

    更新日期:2006-04-01 00:00:00

  • The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator.

    abstract::The geometric accuracy and precision of an image-guided treatment system were assessed. Image guidance is performed using an x-ray volume imaging (XVI) system integrated with a linear accelerator and treatment planning system. Using an amorphous silicon detector and x-ray tube, volumetric computed tomography images ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2143141

    authors: Sharpe MB,Moseley DJ,Purdie TG,Islam M,Siewerdsen JH,Jaffray DA

    更新日期:2006-01-01 00:00:00