Experimental assessment of microwave ablation computational modeling with MR thermometry.

Abstract:

PURPOSE:Computational models are widely used during the design and characterization of microwave ablation (MWA) devices, and have been proposed for pretreatment planning. Our objective was to assess three-dimensional (3D) transient temperature and ablation profiles predicted by MWA computational models with temperature profiles measured experimentally using magnetic resonance (MR) thermometry in ex vivo bovine liver. MATERIALS AND METHODS:We performed MWA in ex vivo tissue under MR guidance using a custom, 2.45 GHz water-cooled applicator. MR thermometry data were acquired for 2 min prior to heating, during 5-10 min microwave exposures, and for 3 min following heating. Fiber-optic temperature sensors were used to validate the accuracy of MR temperature measurements. A total of 13 ablation experiments were conducted using 30-50 W applied power at the applicator input. MWA computational models were implemented using the finite element method, and incorporated temperature-dependent changes in tissue physical properties. Model-predicted ablation zone extents were compared against MRI-derived Arrhenius thermal damage maps using the Dice similarity coefficient (DSC). RESULTS:Prior to heating, the observed standard deviation of MR temperature data was in the range of 0.3-0.7°C. Mean absolute error between MR temperature measurements and fiber-optic temperature probes during heating was in the range of 0.5-2.8°C. The mean DSC between model-predicted ablation zones and MRI-derived Arrhenius thermal damage maps for 13 experimental set-ups was 0.95. When comparing simulated and experimentally (i.e. using MRI) measured temperatures, the mean absolute error (MAE %) relative to maximum temperature change was in the range 5%-8.5%. CONCLUSION:We developed a system for characterizing 3D transient temperature and ablation profiles with MR thermometry during MWA in ex vivo liver tissue, and applied the system for experimental validation of MWA computational models.

journal_name

Med Phys

journal_title

Medical physics

authors

Faridi P,Keselman P,Fallahi H,Prakash P

doi

10.1002/mp.14318

subject

Has Abstract

pub_date

2020-09-01 00:00:00

pages

3777-3788

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Computerized radiographic texture measures for characterizing bone strength: a simulated clinical setup using femoral neck specimens.

    abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598743

    authors: Chinander MR,Giger ML,Martell JM,Jiang C,Favus MJ

    更新日期:1999-11-01 00:00:00

  • SU-E-J-139: Feasibility of Using EPID for Real-Time Target Localization during Treatment.

    abstract:PURPOSE:This study aims to investigate the feasibility of using the images of the treatment fields acquired by an electronic portal imaging device (EPID) for real-time target localization. METHODS:Forty one patients treated with IMRT and RapidArc were recruited in this study including 37 prostate patients and 4 lung p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734975

    authors: Xu Q,Lin M,Chen X,Tong X,Fan J,Dong Z,Chen L,Ma C

    更新日期:2012-06-01 00:00:00

  • X-ray diffraction computed tomography.

    abstract::Coherent scattering of x-ray photons leads to the phenomenon of x-ray diffraction, which is widely used for determining atomic structure in materials science. A technique [x-ray diffraction computed tomography (CT)] is described, analogous to conventional CT, in which the x-ray diffraction properties of a stack of two...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596063

    authors: Harding G,Kosanetzky J,Neitzel U

    更新日期:1987-07-01 00:00:00

  • SU-E-I-41: Characterization of a Linear Fiber-Optic Coupled Dosimeter.

    abstract:PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length repres...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734756

    authors: Hoerner M,Hintenlang D

    更新日期:2012-06-01 00:00:00

  • Re-examining TG-142 recommendations in light of modern techniques for linear accelerator based radiosurgery.

    abstract:PURPOSE:The recent development of multifocal stereotactic radiosurgery (SRS) using a single isocenter volumetric modulated arc theory (VMAT) technique warrants a re-examination of the quality assurance (QA) tolerances for routine mechanical QA recommended by the American Association of Physicists in Medicine Task Group...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962471

    authors: Faught AM,Trager M,Yin FF,Kirkpatrick J,Adamson J

    更新日期:2016-10-01 00:00:00

  • Small-field electron dosimetry for the Philips SL25 linear accelerator.

    abstract::Electron-beam characteristics of a Philips SL25 linear accelerator have been studied. Central-axis percentage depth doses, cross-beam profiles and beam output factors of 6-, 10-, and 20-MeV beams, selected from the available energy range of 4 to 22 MeV, are reported in this paper. The main thrust of this work is to de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596471

    authors: Rashid H,Islam MK,Gaballa H,Rosenow UF,Ting JY

    更新日期:1990-07-01 00:00:00

  • Convolutional neural network-based dosimetry evaluation of esophageal radiation treatment planning.

    abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14434

    authors: Jiang D,Yan H,Chang N,Li T,Mao R,Du C,Guo B,Liu J

    更新日期:2020-10-01 00:00:00

  • On the constancy in composition of polystyrene and polymethylmethacrylate plastics.

    abstract::Variations in the atomic composition, and mass and electron densities of polystyrene and polymethylmethacrylate (PMM) plastics were assessed from experimentally determined mass attenuation coefficients for 125I and 137Cs gamma rays. The means and standard deviations in the mass densities of 16 samples of PMM and 10 sa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594528

    authors: Schulz RJ,Nath R

    更新日期:1979-03-01 00:00:00

  • Examination of a deformable motion model for respiratory movements and 4D dose calculations using different driving surrogates.

    abstract:PURPOSE:The aim of this study was to evaluate a surrogate-driven motion model based on four-dimensional computed tomography that is able to predict CT volumes corresponding to arbitrary respiratory phases. Furthermore, the comparison of three different driving surrogates is examined and the feasibility of using the mod...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12243

    authors: Wölfelschneider J,Seregni M,Fassi A,Ziegler M,Baroni G,Fietkau R,Riboldi M,Bert C

    更新日期:2017-06-01 00:00:00

  • Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship.

    abstract:PURPOSE:Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4944501

    authors: Humbert L,Hazrati Marangalou J,Del Río Barquero LM,van Lenthe GH,van Rietbergen B

    更新日期:2016-04-01 00:00:00

  • Automatic quantitative low contrast analysis of digital chest phantom radiographs.

    abstract::Up to the present, the majority of low contrast object evaluations performed on phantom images have been accomplished in a subjective fashion. This is mainly due to the time and effort required to manually measure each radiograph with a densitometer to obtain quantitative results. However, with the development of digi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543153

    authors: Kwan AL,Filipow LJ,Le LH

    更新日期:2003-03-01 00:00:00

  • Focused RF hyperthermia using magnetic fluids.

    abstract::Heat therapies such as hyperthermia and thermoablation are very promising approaches in the treatment of cancer. Compared with available hyperthermia modalities, magnetic fluid hyperthermia (MFH) yields better results in uniform heating of the deeply situated tumors. In this approach, fluid consisting of superparamagn...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3106343

    authors: Tasci TO,Vargel I,Arat A,Guzel E,Korkusuz P,Atalar E

    更新日期:2009-05-01 00:00:00

  • Actively triggered 4d cone-beam CT acquisition.

    abstract:PURPOSE:4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this "after-the-fact" binning approach, however, projections are uneve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4817479

    authors: Fast MF,Wisotzky E,Oelfke U,Nill S

    更新日期:2013-09-01 00:00:00

  • Model-based optoacoustic inversion with arbitrary-shape detectors.

    abstract:PURPOSE:Optoacoustic imaging enables mapping the optical absorption of biological tissue using optical excitation and acoustic detection. Although most image-reconstruction algorithms are based on the assumption of a detector with an isotropic sensitivity, the geometry of the detector often leads to a response with spa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589141

    authors: Rosenthal A,Ntziachristos V,Razansky D

    更新日期:2011-07-01 00:00:00

  • Sparse and optimal acquisition design for diffusion MRI and beyond.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3700166

    authors: Koay CG,Ozarslan E,Johnson KM,Meyerand ME

    更新日期:2012-05-01 00:00:00

  • In vivo dosimetry by an aSi-based EPID.

    abstract::A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2360014

    authors: Piermattei A,Fidanzio A,Stimato G,Azario L,Grimaldi L,D'Onofrio G,Cilla S,Balducci M,Gambacorta MA,Di Napoli N,Cellini N

    更新日期:2006-11-01 00:00:00

  • Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram.

    abstract:PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4767763

    authors: Stasi M,Bresciani S,Miranti A,Maggio A,Sapino V,Gabriele P

    更新日期:2012-12-01 00:00:00

  • Lag measurement in an a-Se active matrix flat-panel imager.

    abstract::Lag and residual contrast have been quantified in an amorphous selenium (a-Se) active-matrix flat-panel imager (AMFPI) as a function of frame time, kilovoltage (kV) and megavoltage (MV) x-ray photon energies and amount of radiation incident on the detector. The AMFPI contains a 200 microm thick a-Se layer deposited on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1713298

    authors: Schroeder C,Stanescu T,Rathee S,Fallone BG

    更新日期:2004-05-01 00:00:00

  • Calculation of 131I-ortho-iodohippurate absorbed kidney dose: a literature review.

    abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594679

    authors: Flannery A,Veber J,Greenfield MA,McIntyre AB,Hamilton DR

    更新日期:1980-05-01 00:00:00

  • Obtaining S values for rectangular-solid tumors inside rectangular-solid host organs.

    abstract::A method is described for obtaining S values between a tumor and its host organ for use with the MIRD formalism. It applies the point-source specific absorbed fractions for an infinite water medium, tabulated by Berger, to a rectangular solid of arbitrary dimensions which contains a rectangular tumor of arbitrary dime...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596732

    authors: Stinchcomb TG,Durham JS,Fisher DR

    更新日期:1991-05-01 00:00:00

  • Rare-earth scatter fractions in chest radiography.

    abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597041

    authors: Petrone TJ,Steidley KD

    更新日期:1993-03-01 00:00:00

  • SU-E-T-504: Incident Fluence Reconstruction Based on Monte Carlo Finite-Size Pencil Beam Model for Dose Guided Radiation Therapy.

    abstract:PURPOSE:In dose guided radiation therapy, incident fluence is one of the important parameters for both influence verification and dose reconstruction. The objective of this investigation was to develop a method to obtain the incident fluence for dose reconstruction in dose guided radiation therapy (DGRT). METHODS:An i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735593

    authors: Li G,Wu Y,FDS Team.

    更新日期:2012-06-01 00:00:00

  • Improving the calibration of radiochromic films by the use of uncertainties in optical density and dose.

    abstract:PURPOSE:To compare how the inclusion of the uncertainties in dose and optical density affects the results of the calibration of Gafchromic(®) EBT3 radiochromic films. METHODS:Five methods of least square minimization were compared for calibration of radiochromic films. These differed in the way in which the uncertaint...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4811238

    authors: Garcia LI,Azorin JF

    更新日期:2013-07-01 00:00:00

  • Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources.

    abstract:PURPOSE:Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is correc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4831757

    authors: Tornero-López AM,Guirado D,Perez-Calatayud J,Ruiz-Arrebola S,Simancas F,Gazdic-Santic M,Lallena AM

    更新日期:2013-12-01 00:00:00

  • Development and validation of a CT-3D rotational angiography registration method for AVM radiosurgery.

    abstract::In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, whil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1751252

    authors: Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Colombo F,Perini S

    更新日期:2004-06-01 00:00:00

  • In vivo cancer diagnosis with optical spectroscopy and acoustically induced blood stasis using a murine MCa35 model.

    abstract::Ultrasound-induced blood stasis has been observed for more than 30 years. Most of the literature has been focused on the health risks associated with this phenomenon and methods employed to prevent stasis from occurring during ultrasound imaging. To date, experimental observations have been either in vitro or invasive...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198196

    authors: Winey BA,Misic V,Liao L,Parker K,Fenton BM,Yu Y

    更新日期:2006-06-01 00:00:00

  • Linear motion correction in three dimensions applied to dynamic gadolinium enhanced breast imaging.

    abstract::Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accuratel...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598576

    authors: Krishnan S,Chenevert TL,Helvie MA,Londy FL

    更新日期:1999-05-01 00:00:00

  • An analysis of the mechanical parameters used for finite element compression of a high-resolution 3D breast phantom.

    abstract:PURPOSE:The authors previously introduced a methodology to generate a realistic three-dimensional (3D), high-resolution, computer-simulated breast phantom based on empirical data. One of the key components of such a phantom is that it provides a means to produce a realistic simulation of clinical breast compression. In...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3637500

    authors: Hsu CM,Palmeri ML,Segars WP,Veress AI,Dobbins JT 3rd

    更新日期:2011-10-01 00:00:00

  • Automatic tumor segmentation in breast ultrasound images using a dilated fully convolutional network combined with an active contour model.

    abstract:PURPOSE:Due to the low contrast, blurry boundaries, and large amount of shadows in breast ultrasound (BUS) images, automatic tumor segmentation remains a challenging task. Deep learning provides a solution to this problem, since it can effectively extract representative features from lesions and the background in BUS i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13268

    authors: Hu Y,Guo Y,Wang Y,Yu J,Li J,Zhou S,Chang C

    更新日期:2019-01-01 00:00:00

  • Controlled mold geometry for surgical deficit treatment planning.

    abstract::The relatively precise placement of brachytherapy sources afforded by stereotactic frames for brain implants is not generally achievable for other sites, which lack the fixed geometry of the cranium and its contents. An exception is a source-containing rigid mold that delivers brachytherapy when inserted securely in a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597454

    authors: Anderson LL,Zlotolow IM,McCormick B,Harrison LB

    更新日期:1995-03-01 00:00:00