Abstract:
PURPOSE:The purpose of this study is to investigate some characteristics of the beam delivery system and their effects on the dose distribution of intensity-modulated radiation therapy (IMRT) and the results of patient-specific IMRT quality assurance (QA). These characteristics include the accelerator source distribution and multileaf collimator (MLC) geometry. METHODS:Monte Carlo dose calculations based on intensity maps that were built from the actual deliverable IMRT leaf sequences with and without considering the characteristics of the beam delivery system were performed in this study using in-house Monte Carlo software. The effect of the resolution of the intensity maps on the dose distribution was investigated first. The mean dose of the treatment target and the voxel doses in the high dose region of seven IMRT plans generated by different treatment planning systems for Varian 21EX and Siemens Primus linear accelerators were used for comparison and evaluation. RESULTS:The results show that a 0.2 x 0.2 mm2 or smaller pixel size is needed for the intensity maps for accurate IMRT dose calculation. The extrafocal source, MLC leaf thickness, leakage, tongue-and-groove structure, and the effective leaf offset can affect the mean dose by up to 1.5%, 4.5%, 5.6%, 5.3%, and 7.8%, respectively, when these factors are considered separately. They also cause significant uncertainties to the voxel dose with standard deviations up to 2.5%, 0.7%, 2.1%, 1.3%, and 5%, respectively. The overall effect on the mean dose is up to 8% and the standard deviation of the voxel dose uncertainty is up to 6.4% when all the effects are included. The maximum standard deviation is reduced to 4.6% if the voxel size of the dose calculation matrix is increased from 0.04 to 0.3 cm3 to make it comparable with the sensitive volume of the ionization chamber used for IMRT QA measurements. CONCLUSIONS:It can be concluded that the characteristics of the beam delivery system are the major contributors to the uncertainty of measurement-based IMRT QA because most of them are not fully considered in the currently available treatment planning systems.
journal_name
Med Physjournal_title
Medical physicsauthors
Li JS,Lin T,Chen L,Price RA Jr,Ma CMdoi
10.1118/1.3413997subject
Has Abstractpub_date
2010-06-01 00:00:00pages
2491-500issue
6eissn
0094-2405issn
2473-4209journal_volume
37pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The concept of equivalent uniform dose (EUD) has been suggested as a means to quantitatively consider heterogeneous dose distributions within targets. Tumor cell density/function is typically assumed to be uniform. We herein propose to use 18F-labeled 2-deoxyglucose (FDG) positron emission tomography (PET) tumor imagi...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1779372
更新日期:2004-09-01 00:00:00
abstract:PURPOSE:The limited-angle intrafractional verification (LIVE) system was developed to track tumor movement during stereotactic body radiation therapy (SBRT). However, the four-dimensional (4D) MV/kV imaging procedure results in additional radiation dose to patients. This study is to quantify imaging radiation dose from...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13511
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773883
更新日期:2013-02-01 00:00:00
abstract::Nowadays, digital subtraction angiography systems must be able to sustain real-time acquisition (30 frames per second) of 512 x 512 x 8 bit images and store several sequences of such images on low cost and general-purpose mass memories. Concretely, that means a 7.8 Mbytes per second rate and about 780 Mbytes disk spac...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596309
更新日期:1989-11-01 00:00:00
abstract::In conventional dose optimization algorithms, in brachytherapy, multiple objectives are expressed in terms of an aggregating function which combines individual objective values into a single utility value, making the problem single objective, prior to optimization. A multiobjective genetic algorithm (MOGA) was develop...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598697
更新日期:1999-09-01 00:00:00
abstract::We studied a recently proposed aggregated CT reconstruction technique which combines the complementary advantages of kilovoltage (kV) and megavoltage (MV) x-ray imaging. Various phantoms were imaged to study the effects of beam orientations and geometry of the imaging object on image quality of reconstructed CT. It wa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2768862
更新日期:2007-09-01 00:00:00
abstract:PURPOSE:Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow qua...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4943565
更新日期:2016-04-01 00:00:00
abstract::Numerical reconstruction of x-ray spectra from narrow-beam transmission data was tested with published spectra in the range from 45 to 100 kVp. Transmission curves were calculated from the spectra to simulate measured data. Spectra were reconstructed from these transmission curves with use of an iterative numerical an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595834
更新日期:1986-09-01 00:00:00
abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594960
更新日期:1981-05-01 00:00:00
abstract:PURPOSE:Real-time adaptive planning and treatment has been infeasible due in part to its high computational complexity. There have been many recent efforts to utilize graphics processing units (GPUs) to accelerate the computational performance and dose accuracy in radiation therapy. Data structure and memory access pat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4895822
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:This article introduces the use of low power continuous wave frequency modulated radar for medical applications, specifically for remote monitoring of vital signs in patients. METHODS:Gigahertz frequency radar measures the electromagnetic wave signal reflected from the surface of a human body and from tissue b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3267038
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:Calculations of deoxyribonucleic acid (DNA) damages involve many parameters in the computation process. As these parameters are often subject to uncertainties, it is of central importance to comprehensively quantify their impacts on DNA single-strand break (SSB) and double-strand break (DSB) yields. This has be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14036
更新日期:2020-04-01 00:00:00
abstract:PURPOSE:As the predominant driver of respiratory motion, the diaphragm represents a key surrogate for motion management during the irradiation of thoracic cancers. Existing approaches to diaphragm tracking often produce phase-based estimates, suffer from lateral side failures or are not executable in real-time. In this...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13738
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4881096
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:Computer-aided diagnosis (CAD) systems assist in solving subjective diagnosis problems that typically rely on personal experience. A CAD system has been developed to differentiate malignant thyroid nodules from benign thyroid nodules in ultrasound images based on deep learning methods. The diagnostic performanc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14301
更新日期:2020-09-01 00:00:00
abstract::We employed an elastic reservoir filled with tissue-equivalent fluid as an x-ray beam filter for exposure equalization. The filter is designed to be placed between the upper compression plate and the breast. During compression, it will conform to the shape of the peripheral region of the breast and fill the space betw...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596502
更新日期:1990-03-01 00:00:00
abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595356
更新日期:1983-11-01 00:00:00
abstract:PURPOSE:It is very important for calculation of clinical indices and diagnosis to detect thyroid nodules from ultrasound images. However, this task is a challenge mainly due to heterogeneous thyroid nodules with distinct components are similar to background in ultrasound images. In this study, we employ cascade deep co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12134
更新日期:2017-05-01 00:00:00
abstract:PURPOSE:To investigate the inconsistency of recent literature on the effect of magnetic field on the response of radiochromic films, we studied the influence of 0.35 T magnetic field on dosimetric response of EBT3 and EBT-XD GafchromicTM films. METHODS:Two different models of radiochromic films, EBT3 and EBT-XD, were ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14313
更新日期:2020-09-01 00:00:00
abstract::Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1373402
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3633941
更新日期:2011-10-01 00:00:00
abstract::The photon spectra in vacuum around four types of 192Ir HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on 192Ir decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare 192Ir source and around each of fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598763
更新日期:1999-11-01 00:00:00
abstract:PURPOSE:To demonstrate the feasibility of a three-plenoptic camera projection, scintillation-based dosimetry system for measuring three-dimensional (3D) dose distributions of static photon radiation fields. METHODS:Static x-ray photon beams were delivered to a cubic plastic scintillator volume embedded within acrylic ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14213
更新日期:2020-08-01 00:00:00
abstract::Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skele...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3242266
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:Prostate cancer ranks as one of the most common malignancies and currently represents the second leading cancer-specific cause of death in men. The current use of single modality transrectal ultrasound (TRUS) for biopsy guidance has a limited sensitivity and specificity for accurately identifying cancerous lesi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4803498
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12742
更新日期:2018-03-01 00:00:00
abstract::Currently, patients with brain neoplasms must undergo both computed tomography (CT) and magnetic resonance (MR) imaging to take advantage of CT's density information and MR's soft tissue imaging capabilities. A method has been developed that allows virtual simulation, digitally reconstructed radiographs (DRRs), and 3-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598382
更新日期:1998-10-01 00:00:00
abstract:PURPOSE:The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4963813
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:Computational models are widely used during the design and characterization of microwave ablation (MWA) devices, and have been proposed for pretreatment planning. Our objective was to assess three-dimensional (3D) transient temperature and ablation profiles predicted by MWA computational models with temperature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14318
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:Dual source CT (DSCT) systems utilize two measurement systems (A) and (B) offset by about 90 degrees. A special challenge in DSCT is cross-scattered radiation, i.e., scattered radiation from x-ray tube (B) detected in detector (A) and vice versa. Cross-scattered radiation can produce artifacts and degrade the c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3504606
更新日期:2010-11-01 00:00:00