A new open-source GPU-based microscopic Monte Carlo simulation tool for the calculations of DNA damages caused by ionizing radiation - Part II: sensitivity and uncertainty analysis.

Abstract:

PURPOSE:Calculations of deoxyribonucleic acid (DNA) damages involve many parameters in the computation process. As these parameters are often subject to uncertainties, it is of central importance to comprehensively quantify their impacts on DNA single-strand break (SSB) and double-strand break (DSB) yields. This has been a challenging task due to the required large number of simulations and the relatively low computational efficiency using CPU-based MC packages. In this study, we present comprehensive evaluations on sensitivities and uncertainties of DNA SSB and DSB yields on 12 parameters using our GPU-based MC tool, gMicroMC. METHODS:We sampled one electron at a time in a water sphere containing a human lymphocyte nucleus and transport the electrons and generated radicals until 2 Gy dose was accumulated in the nucleus. We computed DNA damages caused by electron energy deposition events in the physical stage and the hydroxyl radicals at the end of the chemical stage. We repeated the computations by varying 12 parameters: (a) physics cross section, (b) cutoff energy for electron transport, (c)-(e) three branching ratios of hydroxyl radicals in the de-excitation of excited water molecules, (f) temporal length of the chemical stage, (g)-(h) reaction radii for direct and indirect damages, (i) threshold energy defining the threshold damage model to generate a physics damage, (j)-(k) minimum and maximum energy values defining the linear-probability damage model to generate a physics damage, and (l) probability to generate a damage by a radical. We quantified sensitivity of SSB and DSB yields with respect to these parameters for cases with 1.0 and 4.5 keV electrons. We further estimated uncertainty of SSB and DSB yields caused by uncertainties of these parameters. RESULTS:Using a threshold of 10% uncertainty as a criterion, threshold energy in the threshold damage model, maximum energy in the linear-probability damage model, and probability for a radical to generate a damage were found to cause large uncertainties in both SSB and DSB yields. The scaling factor of the cross section, cutoff energy, physics reaction radius, and minimum energy in the linear-probability damage model were found to generate large uncertainties in DSB yields. CONCLUSIONS:We identified parameters that can generate large uncertainties in the calculations of SSB and DSB yields. Our study could serve as a guidance to reduce uncertainties of parameters and hence uncertainties of the simulation results.

journal_name

Med Phys

journal_title

Medical physics

authors

Lai Y,Tsai MY,Tian Z,Qin N,Yan C,Hung SH,Chi Y,Jia X

doi

10.1002/mp.14036

subject

Has Abstract

pub_date

2020-04-01 00:00:00

pages

1971-1982

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods.

    abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3682171

    authors: Beichel R,Bornik A,Bauer C,Sorantin E

    更新日期:2012-03-01 00:00:00

  • A treatment planning study comparing HDR and AGIMRT for cervical cancer.

    abstract::The customization of brachytherapy dose distributions for gynecologic malignancies is limited by the spatial positioning of the applicators. We tested the hypothesis that applicator-guided intensity modulated radiation therapy (AGIMRT) has the potential to deliver highly conformal dose distributions to cervical tumors...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1645678

    authors: Wahab SH,Malyapa RS,Mutic S,Grigsby PW,Deasy JO,Miller TR,Zoberi I,Low DA

    更新日期:2004-04-01 00:00:00

  • Vision 20/20: Mammographic breast density and its clinical applications.

    abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4935141

    authors: Ng KH,Lau S

    更新日期:2015-12-01 00:00:00

  • SU-E-T-541: Dose Calculation Algorithm for External Neutron Radiotherapy Based on Pencil Beam Method.

    abstract:PURPOSE:To evaluate the availability and performance of pencil beam algorithm for fast neutrons radiotherapy dose calculations and to achieve improvements in universality, speed and inhomogeneities corrections. METHODS:Pencil beam (PB) method uses integration of dose kernel cross field size to estimate dose distributi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735630

    authors: Moiseev A,Klimanov V

    更新日期:2012-06-01 00:00:00

  • Automatic learning-based beam angle selection for thoracic IMRT.

    abstract:PURPOSE:The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908000

    authors: Amit G,Purdie TG,Levinshtein A,Hope AJ,Lindsay P,Marshall A,Jaffray DA,Pekar V

    更新日期:2015-04-01 00:00:00

  • Reference dataset of users' photon beam modeling parameters for the Eclipse, Pinnacle, and RayStation treatment planning systems.

    abstract:PURPOSE:The aim of this work was to provide a novel description of how the radiotherapy community configures treatment planning system (TPS) radiation beam models for clinically used treatment machines. Here we describe the results of a survey of self-reported TPS beam modeling parameter values across different C-arm l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13892

    authors: Glenn MC,Peterson CB,Followill DS,Howell RM,Pollard-Larkin JM,Kry SF

    更新日期:2020-01-01 00:00:00

  • Discriminating solitary cysts from soft tissue lesions in mammography using a pretrained deep convolutional neural network.

    abstract:PURPOSE:It is estimated that 7% of women in the western world will develop palpable breast cysts in their lifetime. Even though cysts have been correlated with risk of developing breast cancer, many of them are benign and do not require follow-up. We develop a method to discriminate benign solitary cysts from malignant...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12110

    authors: Kooi T,van Ginneken B,Karssemeijer N,den Heeten A

    更新日期:2017-03-01 00:00:00

  • Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching.

    abstract::Image correlation is often required to utilize the complementary information in CT, MRI, and SPECT. A practical method for automatic image correlation in three-dimensions (3D) based on chamfer matching is described. The method starts with automatic extraction of contour points in one modality and automatic segmentatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597344

    authors: van Herk M,Kooy HM

    更新日期:1994-07-01 00:00:00

  • 3D image-guided robotic needle positioning system for small animal interventions.

    abstract:PURPOSE:This paper presents the design of a micro-CT guided small animal robotic needle positioning system. In order to simplify the robotic design and maintain a small targeting error, a novel implementation of the remote center of motion is used in the system. The system has been developed with the objective of achie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4771958

    authors: Bax JS,Waring CS,Sherebrin S,Stapleton S,Hudson TJ,Jaffray DA,Lacefield JC,Fenster A

    更新日期:2013-01-01 00:00:00

  • Poster - Thur Eve - 59: Dosimetric evaluation on the variation of PTV coverage due to patient size reduction using the prostate dose-volume factor in prostate radiotherapy.

    abstract::We proposed to use the prostate dose-volume factor (PDVF), derived from the dose-volume dataset of planning target volume (PTV) in prostate radiotherapy to evaluate treatment plans of prostate volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT). To demonstrate plan evaluation using PDVF...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740167

    authors: Chow J,Jiang R,Markel D

    更新日期:2012-07-01 00:00:00

  • Cone-beam CT-derived relative stopping power map generation via deep learning for proton radiotherapy.

    abstract:PURPOSE:In intensity-modulated proton therapy (IMPT), protons are used to deliver highly conformal dose distributions, targeting tumors, and sparing organs-at-risk. However, due to uncertainties in both patient setup and relative stopping power (RSP) calculation, margins are added to the treatment volume during treatme...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14347

    authors: Harms J,Lei Y,Wang T,McDonald M,Ghavidel B,Stokes W,Curran WJ,Zhou J,Liu T,Yang X

    更新日期:2020-09-01 00:00:00

  • A compensative model for the angle-dependence of motion estimates in noninvasive vascular elastography.

    abstract:PURPOSE:Atherosclerosis of peripheral cerebral arteries can lead to stroke either by stenosis formation or plaque rupture. This pathology is initiated by the alteration of arterial wall mechanical properties shown to be assessable by ultrasound elastography. Recently, noninvasive vascular elastography (NIVE) was introd...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539701

    authors: Mercure E,Deprez JF,Fromageau J,Basset O,Soulez G,Cloutier G,Maurice RL

    更新日期:2011-02-01 00:00:00

  • TransitQA - A new method for transit dosimetry of Tomotherapy patients.

    abstract:PURPOSE:TransitQA is an innovative method for Tomotherapy transit dosimetry using the on-board detector (OBD). Our previously published model for Tomotherapy treatment plan verification (AirQA) has been enhanced to take into account patient and couch transmission. AirQA estimates the OBD signal during irradiation with ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12672

    authors: Pisaturo O,Miéville F,Tercier PA,Allal AS

    更新日期:2018-01-01 00:00:00

  • Knowledge-based planning for intensity-modulated radiation therapy: A review of data-driven approaches.

    abstract:PURPOSE:Intensity-Modulated Radiation Therapy (IMRT), including its variations (including IMRT, Volumetric Arc Therapy (VMAT), and Tomotherapy), is a widely used and critically important technology for cancer treatment. It is a knowledge-intensive technology due not only to its own technical complexity, but also to the...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.13526

    authors: Ge Y,Wu QJ

    更新日期:2019-06-01 00:00:00

  • Design of a focused collimator for proton therapy spot scanning using Monte Carlo methods.

    abstract:PURPOSE:When designing a collimation system for pencil beam spot scanning proton therapy, a decision must be made whether or not to rotate, or focus, the collimator to match beamlet deflection as a function of off-axis distance. If the collimator is not focused, the beamlet shape and fluence will vary as a function of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14139

    authors: Geoghegan TJ,Nelson NP,Flynn RT,Hill PM,Rana S,Hyer DE

    更新日期:2020-07-01 00:00:00

  • Diagnostic efficacy of computer extracted image features in optical coherence tomography of the precancerous cervix.

    abstract:PURPOSE:To determine the diagnostic efficacy of optical coherence tomography (OCT) to identify cervical intraepithelial neoplasia (CIN) grade 2 or higher by computer-aided diagnosis (CADx). METHODS:OCT has been investigated as a screening/diagnostic tool in the management of preinvasive and early invasive cancers of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3523098

    authors: Kang W,Qi X,Tresser NJ,Kareta M,Belinson JL,Rollins AM

    更新日期:2011-01-01 00:00:00

  • Four-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT.

    abstract:PURPOSE:Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3544369

    authors: Park JC,Park SH,Kim JH,Yoon SM,Kim SS,Kim JS,Liu Z,Watkins T,Song WY

    更新日期:2011-02-01 00:00:00

  • Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: first patient studies.

    abstract:PURPOSE:Quantitative cone-beam CT (CBCT) imaging is on increasing demand for high-performance image guided radiation therapy (IGRT). However, the current CBCT has poor image qualities mainly due to scatter contamination. Its current clinical application is therefore limited to patient setup based on only bony structure...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3693050

    authors: Niu T,Al-Basheer A,Zhu L

    更新日期:2012-04-01 00:00:00

  • An alternative VMAT with prior knowledge about the type of leaf motion utilizing projection method for concave targets.

    abstract::The authors present an alternative approach to inverse planning optimization and apply it to volumetric modulated are therapy (VMAT) in one rotation with a prior knowledge about the type of leaf motions. The optimization is based on the projection theorem in inner product spaces. MLC motion is directly considered in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3173815

    authors: Hoegele W,Loeschel R,Zygmanski P

    更新日期:2009-08-01 00:00:00

  • Inter- and intra-software reproducibility of computed tomography lung density measurements.

    abstract:PURPOSE:Multiple commercial, open-source, and academic software tools exist for objective quantification of lung density in computed tomography (CT) images. The purpose of this study was to evaluate the intersoftware reproducibility of CT lung density measurements. METHODS:Computed tomography images from 50 participan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14130

    authors: Kirby M,Hatt C,Obuchowski N,Humphries SM,Sieren J,Lynch DA,Fain SB,QIBA Lung Density Committee.

    更新日期:2020-07-01 00:00:00

  • Technical note: A novel boundary condition using contact elements for finite element based deformable image registration.

    abstract::Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1774131

    authors: Zhang T,Orton NP,Mackie TR,Paliwal BR

    更新日期:2004-09-01 00:00:00

  • A Dirichlet process mixture model for automatic (18)F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions.

    abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947123

    authors: Giri MG,Cavedon C,Mazzarotto R,Ferdeghini M

    更新日期:2016-05-01 00:00:00

  • Correcting magnetic resonance k-space data for in-plane motion using an optical position tracking system.

    abstract:PURPOSE:Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. METHODS:In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion dat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3254189

    authors: Marxen M,Marmurek J,Baker N,Graham SJ

    更新日期:2009-12-01 00:00:00

  • Creating optimal code for GPU-accelerated CT reconstruction using ant colony optimization.

    abstract:PURPOSE:CT reconstruction algorithms implemented on the GPU are highly sensitive to their implementation details and the hardware they run on. Fine-tuning an implementation for optimal performance can be a time consuming task and require many updates when the hardware changes. There are some techniques that do automati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773045

    authors: Papenhausen E,Zheng Z,Mueller K

    更新日期:2013-03-01 00:00:00

  • A sparse orthogonal collimator for small animal intensity-modulated radiation therapy part I: Planning system development and commissioning.

    abstract:PURPOSE:To achieve more translatable preclinical research results, small animal irradiation needs to more closely simulate human radiotherapy. Although the clinical gold standard is intensity-modulated radiation therapy (IMRT), the direct translation of this method for small animals is impractical. In this study we des...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13872

    authors: Woods K,Nguyen D,Neph R,Ruan D,O'Connor D,Sheng K

    更新日期:2019-12-01 00:00:00

  • Image resolution of a microchannel plate x-ray image intensifier.

    abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594463

    authors: Gould RG

    更新日期:1978-01-01 00:00:00

  • Water-equivalent dosimeter array for small-field external beam radiotherapy.

    abstract::With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2719363

    authors: Archambault L,Beddar AS,Gingras L,Lacroix F,Roy R,Beaulieu L

    更新日期:2007-05-01 00:00:00

  • Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography.

    abstract::Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3125137

    authors: Jost G,Mensing T,Golfier S,Lawaczeck R,Pietsch H,Hütter J,Cibik L,Gerlach M,Krumrey M,Fratzscher D,Arkadiev V,Wedell R,Haschke M,Langhoff N,Wust P,Lüdemann L

    更新日期:2009-06-01 00:00:00

  • The dosimetric properties of an intraoperative radiation therapy applicator system for a Mevatron-80.

    abstract::An applicator system for intraoperative radiation therapy has been fabricated which does not require physical docking with the accelerator. A dosimetric study has been completed which documents the properties of this system for a variety of electron beam energies, applicator sizes, collimator settings, both primary an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596338

    authors: Nelson CE,Cook R,Rakfal S

    更新日期:1989-09-01 00:00:00

  • A study of effective attenuation coefficient for calculating tissue compensator thickness.

    abstract::Dose uniformity throughout the treatment volume is essential to precision radiation therapy. Tissue compensators are often used as a means to eliminate dose nonuniformity resulting from surface contour irregularities. This paper evaluates the accuracy of using an effective attenuation coefficient for calculating the t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596561

    authors: Bagne FR,Samsami N,Hoke SW,Bronn DG

    更新日期:1990-01-01 00:00:00