Delivery validation of an automated modulated electron radiotherapy plan.

Abstract:

PURPOSE:Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In this work, the authors investigate the accuracy and efficiency of an end-to-end MERT plan and automated delivery method. METHODS:Treatment planning was initiated on a previously treated whole breast irradiation case including an electron boost. All dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. RESULTS:The automated delivery, which covered four electron energies, 196 subfields, and 6183 total MU was completed in 25.8 min, including 6.2 min of beam-on time. The remainder of the delivery time was spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. Comparison of the planned and delivered film dose gave 3%/3mm gamma pass rates of 62.1%, 99.8%, 97.8%, 98.3%, and 98.7% for the 9, 12, 16, and 20 MeV, and combined energy deliveries, respectively. Delivery was also performed with a MapCHECK device and resulted in 3%/3 mm gamma pass rates of 88.8%, 86.1%, 89.4%, and 94.8% for the 9, 12, 16, and 20 MeV energies, respectively. CONCLUSIONS:Results of the authors' study showed that an accurate delivery utilizing an add-on tertiary electron collimator is possible using Monte Carlo calculated plans and inverse optimization, which brings MERT closer to becoming a viable option for physicians in treating superficial malignancies.

journal_name

Med Phys

journal_title

Medical physics

authors

Connell T,Alexander A,Papaconstadopoulos P,Serban M,Devic S,Seuntjens J

doi

10.1118/1.4876297

subject

Has Abstract

pub_date

2014-06-01 00:00:00

pages

061715

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

41

pub_type

杂志文章
  • Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation.

    abstract:PURPOSE:An improvement in tissue assignment for low-dose rate brachytherapy (LDRB) patients using more accurate Monte Carlo (MC) dose calculation was accomplished with a metallic artifact reduction (MAR) method specific to dual-energy computed tomography (DECT). METHODS:The proposed MAR algorithm followed a four-step ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947486

    authors: Côté N,Bedwani S,Carrier JF

    更新日期:2016-05-01 00:00:00

  • Practical dosimetric considerations of a 10-MV photon beam.

    abstract::An overall practical dosimetric study of a 10-MV photon beam produced by a Varian Clinac-18 linear accelerator is presented. In particular measurements were made to provide data which could be utilized in computerized dosage calculations using the concept of dividing the radiation beam into primary and scatter compone...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594311

    authors: Van Dyk J

    更新日期:1977-03-01 00:00:00

  • Technical Note: Correction for the effect of breathing variations in CT pulmonary ventilation imaging.

    abstract:PURPOSE:The accuracy and precision of computed tomography (CT) pulmonary ventilation imaging with conventional CT scanners are limited by breathing variations. We propose a method to correct for the effect of breathing variations in CT ventilation imaging based on external respiratory signals acquired throughout a scan...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1002/mp.12634

    authors: Yamamoto T,Kabus S

    更新日期:2018-01-01 00:00:00

  • A general model of microcirculatory blood flow effects in gradient sensitized MRI.

    abstract::A general expression is derived for the NMR signal from a fluid undergoing random directional flow such as encountered within the microcirculation. The dependence of the echo amplitude on flow velocity, sample morphology, and experimental parameters are described in terms of a temporal velocity autocorrelation functio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597170

    authors: Kennan RP,Gao JH,Zhong J,Gore JC

    更新日期:1994-04-01 00:00:00

  • SU-E-T-300: Monte Carlo Simulation of Single-Plane Magnetically Focused Narrow Proton Beams.

    abstract::Purpose To investigate narrow, elongated magnetically focused proton beams and compare their properties with passively collimated beams using Monte Carlo simulation. METHODS:We performed Geant4 Monte Carlo simulations involving a single quadrapole focusing magnet, thereby creating a flattened beam with an elongated e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735386

    authors: McAuley G,Barnes S,Wroe A,Slater J

    更新日期:2012-06-01 00:00:00

  • Selecting registration schemes in case of interstitial lung disease follow-up in CT.

    abstract:PURPOSE:Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. METHODS:A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4923170

    authors: Vlachopoulos G,Korfiatis P,Skiadopoulos S,Kazantzi A,Kalogeropoulou C,Pratikakis I,Costaridou L

    更新日期:2015-08-01 00:00:00

  • A fast double template convolution isocenter evaluation algorithm with subpixel accuracy.

    abstract:PURPOSE:To design a fast Winston Lutz (fWL) algorithm for accurate analysis of radiation isocenter from images without edge detection or center of mass calculations. METHODS:An algorithm has been developed to implement the Winston Lutz test for mechanical/ radiation isocenter agreement using an electronic portal imagi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3524227

    authors: Winey B,Sharp G,Bussière M

    更新日期:2011-01-01 00:00:00

  • Prior data assisted compressed sensing: a novel MR imaging strategy for real time tracking of lung tumors.

    abstract:PURPOSE:Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4885960

    authors: Yip E,Yun J,Wachowicz K,Heikal AA,Gabos Z,Rathee S,Fallone BG

    更新日期:2014-08-01 00:00:00

  • The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy.

    abstract::Methods for scatter dose calculations in brachytherapy have been developed based on the collapsed cone superposition algorithm. The methods account for effects on the scatter dose caused by the three-dimensional distribution of heterogeneities in the irradiated volume and are considerably faster than methods based on ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1290485

    authors: Carlsson AK,Ahnesjö A

    更新日期:2000-10-01 00:00:00

  • Temporal and spectral imaging with micro-CT.

    abstract:PURPOSE:Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with du...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736809

    authors: Johnston SM,Johnson GA,Badea CT

    更新日期:2012-08-01 00:00:00

  • Measurement of x-ray attenuation coefficients of aqueous solutions of indocyanine green and glycated chitosan.

    abstract::We report our experimental results of measurements of x-ray attenuation coefficients of aqueous solutions of a light absorbing dye, indocyanine green, and an immunoadjuvant, glycated chitosan. In the treatment of metastatic tumors in rats using a novel laser immunotherapy these solutions were administered in situ. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598633

    authors: Xu F,Liu H,Wu X,Jiang H,Nordquist RE,Chen WR

    更新日期:1999-07-01 00:00:00

  • Repeatability of SUV measurements in serial PET.

    abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578604

    authors: Schwartz J,Humm JL,Gonen M,Kalaigian H,Schoder H,Larson SM,Nehmeh SA

    更新日期:2011-05-01 00:00:00

  • SU-E-T-459: Radiobiological Evaluation of Implant Duration and Radionuclide Selection for COMS Eye Plaque Brachytherapy Using an Objective Function.

    abstract:PURPOSE:The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide (R) and implant duration (T). This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position (P), prescription dose, R, an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735548

    authors: Gagne N,Rivard M

    更新日期:2012-06-01 00:00:00

  • Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

    abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3002314

    authors: Wronski MM,Rowlands JA

    更新日期:2008-12-01 00:00:00

  • Eye tracking and gating system for proton therapy of orbital tumors.

    abstract:PURPOSE:A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. METHODS:We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729708

    authors: Shin D,Yoo SH,Moon SH,Yoon M,Lee SB,Park SY

    更新日期:2012-07-01 00:00:00

  • A voxel-based multiscale model to simulate the radiation response of hypoxic tumors.

    abstract:PURPOSE:In radiotherapy, it is important to predict the response of tumors to irradiation prior to the treatment. This is especially important for hypoxic tumors, which are known to be highly radioresistant. Mathematical modeling based on the dose distribution, biological parameters, and medical images may help to impr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903298

    authors: Espinoza I,Peschke P,Karger CP

    更新日期:2015-01-01 00:00:00

  • A localization algorithm and error analysis for stereo x-ray image guidance.

    abstract::Stereo x-ray radiography attracts increasing attention in major clinical applications. The purpose of this paper is to analyze the 3D localization error for breast biopsy procedures and provide guidelines for improving its accuracy. Our prototype is a CCD based digital stereo x-ray imaging system. The mathematical mod...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598953

    authors: Jiang H,Liu H,Wang G,Chen W,Fajardo LL

    更新日期:2000-05-01 00:00:00

  • SU-E-T-302: A Simulation Study with Geant4 Investigating the Secondary Prompt Gamma Emissions from Incident 40 MeV Protons Onto Various Materials.

    abstract:PURPOSE:This study aims to investigate the prompt secondary gamma spectrum and thedepth-dose distributions of incident 40 MeV protons onto various phantom materials.The goal is to find a relationship between the secondary prompt gamma emissions andthe range of the incident particles. METHODS:An application was constru...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735388

    authors: Lau A,Chen Y,Ahmad S

    更新日期:2012-06-01 00:00:00

  • A contrast-detail analysis of diagnostic ultrasound imaging.

    abstract::For diagnostic ultrasound imaging, as in computed tomography, a feature of prime importance is the detection of focal lesions of varying size and contrast (echo amplitude) from surrounding tissue. This study describes a new tissue-stimulating phantom which has been used to measure the threshold detection of varying co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595218

    authors: Smith SW,Lopez H

    更新日期:1982-01-01 00:00:00

  • On the accuracy of techniques for obtaining the calibration coefficient N(K) of 192Ir HDR brachytherapy sources.

    abstract::The accuracy of interpolation or averaging procedures for obtaining the calibration coefficient N(K) for 192Ir high-dose-rate brachytherapy sources has been investigated using the EGSnrc Monte Carlo simulation system. It is shown that the widely used two-point averaging procedure of Goetsch et al. [Med. Phys. 18, 462 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2239198

    authors: Mainegra-Hing E,Rogers DW

    更新日期:2006-09-01 00:00:00

  • Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

    abstract:PURPOSE:Recent advances in compressed sensing (CS) enable accurate CT image reconstruction from highly undersampled and noisy projection measurements, due to the sparsifiable feature of most CT images using total variation (TV). These novel reconstruction methods have demonstrated advantages in clinical applications wh...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729837

    authors: Niu T,Zhu L

    更新日期:2012-07-01 00:00:00

  • Investigation of gamma knife image registration errors resulting from misalignment between the patient and the imaging axis.

    abstract::The ability of Leksell GammaPlan to perform stereotactic space localizations with image sets where there is misalignment of the patient's head (stereotactic frame and fiducial apparatus) relative to the computed tomography (CT) scanner coordinate system was studied. Misalignment is sometimes necessary for patient comf...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2179751

    authors: Cernica G,Wang Z,Malhotra H,de Boer S,Podgorsak MB

    更新日期:2006-04-01 00:00:00

  • Three-dimensional dose reconstruction of breast cancer treatment using portal imaging.

    abstract::In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the pat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1589496

    authors: Louwe RJ,Damen EM,van Herk M,Minken AW,Törzsök O,Mijnheer BJ

    更新日期:2003-09-01 00:00:00

  • X-ray phase contrast imaging of the breast: analysis of tissue simulating materials.

    abstract:PURPOSE:Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794503

    authors: Vedantham S,Karellas A

    更新日期:2013-04-01 00:00:00

  • Measurement with microscopic MRI and simulation of flow in different aneurysm models.

    abstract:PURPOSE:The impact and the development of aneurysms depend to a significant degree on the exchange of liquid between the regular vessel and the pathological extension. A better understanding of this process will lead to improved prediction capabilities. The aim of the current study was to investigate fluid-exchange in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4929758

    authors: Edelhoff D,Walczak L,Frank F,Heil M,Schmitz I,Weichert F,Suter D

    更新日期:2015-10-01 00:00:00

  • Comparison of two independent exposure measurement techniques for clinical I-125 seeds.

    abstract::This investigation contains the results of exposure measurements on two types of clinical I-125 seeds: a model 6702 no-marker seed, and a model 6711 silver wire seed. Measurements were made locally with a parallel-plate mammography chamber, traceable to the National Bureau of Standards (NBS) calibration. The same seed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595784

    authors: Kubo H

    更新日期:1985-03-01 00:00:00

  • Stress analysis using anatomically realistic coronary tree.

    abstract::Plaque rupture with superimposed thrombosis is the main cause of the acute coronary syndromes of unstable angina, myocardial infarction, and sudden death. Endothelial disruption leading to plaque rupture may relate to mechanical fatigue associated with cyclic flexion of plaques. A novel method is proposed to assess st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1593635

    authors: Wu HC,Chen SY,Shroff SG,Carroll JD

    更新日期:2003-11-01 00:00:00

  • The enhancement of radiotherapy verification images by an automated edge detection technique.

    abstract::Adaptive histogram equalization techniques are known to be effective for the enhancement of contrast in portal images acquired during radiotherapy treatments. A significant drawback is the loss of definition on the edges of the treatment field. Analysis of this problem shows that it can be remedied by separating the t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596807

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1992-05-01 00:00:00

  • Cavity contour segmentation in chest radiographs using supervised learning and dynamic programming.

    abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881096

    authors: Maduskar P,Hogeweg L,de Jong PA,Peters-Bax L,Dawson R,Ayles H,Sánchez CI,van Ginneken B

    更新日期:2014-07-01 00:00:00

  • Surface dose rate calibration of Sr-90 plane ophthalmic applicators.

    abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596702

    authors: Goetsch SJ,Sunderland KS

    更新日期:1991-03-01 00:00:00