X-ray phase contrast imaging of the breast: analysis of tissue simulating materials.

Abstract:

PURPOSE:Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. METHODS:Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n = 1 - δ + i β. The real part of the refractive index, specifically the refractive index decrement (δ), over the energy range of 5-50 keV were determined using XOP software (version 2.3, European Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine δ. At each x-ray photon energy, the absolute percent difference in δ between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient μ, and hence β, was considered to be best representative of that breast tissue. RESULTS:Over the energy range of 5-50 keV, while the δ of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the μ of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the δ of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of μ. Polymethyl methacrylate, a commonly used tissue substitute, exhibited δ greater than fibroglandular tissue by ≈ 12%. The A-150 plastic closely approximated the skin. Several materials exhibited δ between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between δ and μ for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the δ and μ of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited δ greater than calcium hydroxyapatite by ≈ 23%. CONCLUSIONS:A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications.

journal_name

Med Phys

journal_title

Medical physics

authors

Vedantham S,Karellas A

doi

10.1118/1.4794503

subject

Has Abstract

pub_date

2013-04-01 00:00:00

pages

041906

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

40

pub_type

杂志文章
  • Scanned-projection digital mammography.

    abstract::The effectiveness of film-screen mammography is limited by tradeoffs between latitude and contrast, film granularity, and the need to increase dose when antiscatter methods are used. We are currently developing a scanned-projection digital mammography (SPDM) system to overcome these limitations. The system consists of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596147

    authors: Nishikawa RM,Mawdsley GE,Fenster A,Yaffe MJ

    更新日期:1987-09-01 00:00:00

  • Explicit optimization of plan quality measures in intensity-modulated radiation therapy treatment planning.

    abstract:PURPOSE:To formulate convex planning objectives of treatment plan multicriteria optimization with explicit relationships to the dose-volume histogram (DVH) statistics used in plan quality evaluation. METHODS:Conventional planning objectives are designed to minimize the violation of DVH statistics thresholds using pena...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12146

    authors: Engberg L,Forsgren A,Eriksson K,Hårdemark B

    更新日期:2017-06-01 00:00:00

  • Cascaded systems analysis of noise reduction algorithms in dual-energy imaging.

    abstract::An important aspect of dual-energy (DE) x-ray image decomposition is the incorporation of noise reduction techniques to mitigate the amplification of quantum noise. This article extends cascaded systems analysis of imaging performance to DE imaging systems incorporating linear noise reduction algorithms. A general ana...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2826556

    authors: Richard S,Siewerdsen JH

    更新日期:2008-02-01 00:00:00

  • Sampling methods for a matrix ionization chamber system.

    abstract::To achieve increased image acquisition speed or better image quality, several read-out methods for a matrix ionization chamber system have been investigated. In this device, which is applied for portal imaging in radiation therapy, 256 x 256 small liquid-filled ionization chambers are scanned by switching the polarizi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596829

    authors: van Herk M,Bijhold J,Hoogervorst B,Meertens H

    更新日期:1992-03-01 00:00:00

  • Systematic feasibility analysis of performing elastography using reduced dose CT lung image pairs.

    abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14112

    authors: Hasse K,Hsieh SS,O'Connell D,Stiehl B,Min Y,Neylon J,Low DA,Santhanam AP

    更新日期:2020-08-01 00:00:00

  • Harmonic phase angle as a concentration-independent measure of nanoparticle dynamics.

    abstract:PURPOSE:The harmonic spectrum of magnetic nanoparticles contains valuable information about the quantity and environment of the particles. Harmonic amplitudes have been used to produce quantitative images and ratios of these amplitudes have been used to monitor changes in the particle environment. Harmonic phase angles...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3426294

    authors: Rauwerdink AM,Weaver JB

    更新日期:2010-06-01 00:00:00

  • Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T.

    abstract:PURPOSE:To evaluate the performance and efficacy for intensity inhomogeneity correction of various sequences of the human brain in 7T MRI using the extended version of the unified segmentation algorithm. MATERIALS:Ten healthy volunteers were scanned with four different sequences (2D spin echo [SE], 3D fast SE, 2D fast...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4860954

    authors: Uwano I,Kudo K,Yamashita F,Goodwin J,Higuchi S,Ito K,Harada T,Ogawa A,Sasaki M

    更新日期:2014-02-01 00:00:00

  • Scatter-glare correction using a convolution algorithm with variable weighting.

    abstract::Several investigators have approximated the scatter component of digital radiographic images by applying a constant weighting factor to a convolved version of the detected image. The scatter approximation is then subtracted from the detected image. When a constant weighting factor is used, the scatter in areas of low ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596088

    authors: Naimuddin S,Hasegawa B,Mistretta CA

    更新日期:1987-05-01 00:00:00

  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • High resolution 2D dose measurement device based on a few long scintillating fibers and tomographic reconstruction.

    abstract:PURPOSE:Patient-specific QA of highly conformal radiotherapy treatments are usually conducted using 2D or 3D dosimetry of the incident dose distribution in a water-equivalent phantom. However, dosimeters typically used for this task usually lack in either spatial resolution or dose accuracy. The purpose of this work is...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736526

    authors: Goulet M,Archambault L,Beaulieu L,Gingras L

    更新日期:2012-08-01 00:00:00

  • Automated quantification and evaluation of motion artifact on coronary CT angiography images.

    abstract:PURPOSE:This study developed and validated a Motion Artifact Quantification algorithm to automatically quantify the severity of motion artifacts on coronary computed tomography angiography (CCTA) images. The algorithm was then used to develop a Motion IQ Decision method to automatically identify whether a CCTA dataset ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13243

    authors: Ma H,Gros E,Baginski SG,Laste ZR,Kulkarni NM,Okerlund D,Schmidt TG

    更新日期:2018-12-01 00:00:00

  • On the efficiency of photon beam treatment head simulations.

    abstract::The paper presents a theoretical derivation of the photon fluence simulation efficiency in photon beam treatment head simulations without and with bremsstrahlung splitting. The expressions obtained provide a rigorous explanation of the efficiency dependence on scoring zone size and splitting number and explain the lar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1943808

    authors: Kawrakow I

    更新日期:2005-07-01 00:00:00

  • Application of the TRS 483 code of practice for reference and relative dosimetry in tomotherapy.

    abstract:PURPOSE:To apply the recent code of practice from the IAEA/AAPM, TRS 483, to helical tomotherapy (HT) for reference and relative dosimetry obtaining correction factors for the Exradin A1SL ionization chamber. METHODS:The beam quality correction factor for the A1SL chamber was obtained through three different approache...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13855

    authors: Lopes MDC,Santos T,Ventura T,Capela M

    更新日期:2019-12-01 00:00:00

  • The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy.

    abstract::Methods for scatter dose calculations in brachytherapy have been developed based on the collapsed cone superposition algorithm. The methods account for effects on the scatter dose caused by the three-dimensional distribution of heterogeneities in the irradiated volume and are considerably faster than methods based on ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1290485

    authors: Carlsson AK,Ahnesjö A

    更新日期:2000-10-01 00:00:00

  • Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233.

    abstract:BACKGROUND:The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. AIMS:This report offers updated testing guid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13763

    authors: Samei E,Bakalyar D,Boedeker KL,Brady S,Fan J,Leng S,Myers KJ,Popescu LM,Ramirez Giraldo JC,Ranallo F,Solomon J,Vaishnav J,Wang J

    更新日期:2019-11-01 00:00:00

  • High correlation between radiation dose estimates for 256-slice CT obtained by highly parallelized hybrid Monte Carlo computation and solid-state metal-oxide semiconductor field-effect transistor measurements in physical anthropomorphic phantoms.

    abstract:PURPOSE:Accurate, patient-specific radiation dosimetry for CT scanning is critical to optimize radiation doses and balance dose against image quality. While Monte Carlo (MC) simulation is often used to estimate doses from CT, comparison of estimates to experimentally measured values is lacking for advanced CT scanners ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13780

    authors: Prinsen P,Trattner S,Wiegert J,Gerland EL,Shefer E,Morton T,Thompson CM,Cheng B,Halliburton SS,Einstein AJ

    更新日期:2019-11-01 00:00:00

  • Differences in the lesion formation process between focused ultrasound and microwave ablations.

    abstract::The objective is to understand the differences in the lesion formation processes between microwave and high-intensity focused ultrasound (HIFU) ablation. The lesions formed by microwaves and HIFU were real-time monitored and compared using transparent tissue-mimicking phantoms at 60 and 70 W of driving electrical powe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2193689

    authors: Chen WS,Wu CC,Fang HY,Liu HL

    更新日期:2006-05-01 00:00:00

  • Re-examining TG-142 recommendations in light of modern techniques for linear accelerator based radiosurgery.

    abstract:PURPOSE:The recent development of multifocal stereotactic radiosurgery (SRS) using a single isocenter volumetric modulated arc theory (VMAT) technique warrants a re-examination of the quality assurance (QA) tolerances for routine mechanical QA recommended by the American Association of Physicists in Medicine Task Group...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962471

    authors: Faught AM,Trager M,Yin FF,Kirkpatrick J,Adamson J

    更新日期:2016-10-01 00:00:00

  • Sci-Thurs PM: Delivery-03: Optical imaging of microscopic radiation dose gradients using a digital microscope.

    abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965910

    authors: Keller BM,Peressotti C,Pignol JP

    更新日期:2008-07-01 00:00:00

  • Intensity-modulation radiotherapy using independent collimators: an algorithm study.

    abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598794

    authors: Dai JR,Hu YM

    更新日期:1999-12-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • Validation of a deformable image registration technique for cone beam CT-based dose verification.

    abstract:PURPOSE:As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903292

    authors: Moteabbed M,Sharp GC,Wang Y,Trofimov A,Efstathiou JA,Lu HM

    更新日期:2015-01-01 00:00:00

  • Selecting beam weight and wedge filter on the basis of dose gradient analysis.

    abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1286591

    authors: Dai J,Zhu Y

    更新日期:2000-08-01 00:00:00

  • Sensitivity of amorphous selenium to x rays from 40 kVp to 18 MV: measurements and implications for portal imaging.

    abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598219

    authors: Mah D,Rowlands JA,Rawlinson JA

    更新日期:1998-04-01 00:00:00

  • SU-E-T-267: Construction and Evaluation of a Neutron Wall to Shield a 15 MV Linac in a Low-Energy Vault.

    abstract:PURPOSE:To design and quantify the shielding efficacy of an inner Borated Polyethylene (BPE)wall for a 15 MV linac in a low energy vault. METHODS:A Varian TrueBeam linac with a maximum photon energy of 15 MV was installed in asmaller, preexisting vault. This vault originally housed a low-energy machine and did not hav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735334

    authors: Speiser M,Hager F,Foster R,Solberg T

    更新日期:2012-06-01 00:00:00

  • Gadolinium neutron capture therapy for brain tumors: a computer study.

    abstract::A Monte Carlo computer study of the total dose distribution from neutrons and prompt gamma emissions (but excluding the contribution from conversion and Auger electrons) for gadolinium neutron capture therapy of brain tumors has been carried out in order to test the theoretic feasibility of this modality using commerc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596761

    authors: Masiakowski JT,Horton JL,Peters LJ

    更新日期:1992-09-01 00:00:00

  • GateCT™ surface tracking system for respiratory signal reconstruction in 4DCT imaging.

    abstract:PURPOSE:To assess the temporal and spatial accuracy of the GateCT™ system (VisionRT, London, UK), a recently released respiratory tracking system for 4DCT, under both ideal and nonideal respiratory conditions. METHODS:Three experiments were performed by benchmarking and comparing its results with the ground-truth inpu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3671941

    authors: Kauweloa KI,Ruan D,Park JC,Sandhu A,Kim GY,Pawlicki T,Watkins WT,Song B,Song WY

    更新日期:2012-01-01 00:00:00

  • SU-E-J-106: Atlas-Based Segmentation: Evaluation of a Multi-Atlas Approach for Lung Cancer.

    abstract:PURPOSE:Previous studies have shown atlas-based segmentation using a single best matched (SBM) atlas subject can significantly reduce contouring time. A new multi-atlas approach has been shown to provide greater accuracy than SBM for cancer of the head and neck. The goal of this study was to evaluate the multi-atlas te...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734942

    authors: Pirozzi S,Horvat M,Piper J,Nelson A

    更新日期:2012-06-01 00:00:00

  • Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass.

    abstract:PURPOSE:Helical tomotherapy is a complex delivery technique, integrating CT image guidance and intensity modulated radiotherapy in a single system. The integration of the CT detector ring on the gantry not only allows patient position verification but is also often used to perform various QA procedures. This convenienc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3566067

    authors: Wong JH,Hardcastle N,Tomé WA,Bayliss A,Tolakanahalli R,Lerch ML,Petasecca M,Carolan M,Metcalfe P,Rosenfeld AB

    更新日期:2011-04-01 00:00:00

  • Poster - Thur Eve - 59: Dosimetric evaluation on the variation of PTV coverage due to patient size reduction using the prostate dose-volume factor in prostate radiotherapy.

    abstract::We proposed to use the prostate dose-volume factor (PDVF), derived from the dose-volume dataset of planning target volume (PTV) in prostate radiotherapy to evaluate treatment plans of prostate volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT). To demonstrate plan evaluation using PDVF...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740167

    authors: Chow J,Jiang R,Markel D

    更新日期:2012-07-01 00:00:00