Differences in the lesion formation process between focused ultrasound and microwave ablations.

Abstract:

:The objective is to understand the differences in the lesion formation processes between microwave and high-intensity focused ultrasound (HIFU) ablation. The lesions formed by microwaves and HIFU were real-time monitored and compared using transparent tissue-mimicking phantoms at 60 and 70 W of driving electrical power. Microwaves and HIFU produced lesions different in shape, size, and developing processes. For HIFU ablations, the hyperechoic region appeared bigger in ultrasonic images, as compared with the protein denatured region observed optically at the end of 100 s ablations. On the contrary, the hyperechoic signal was only limited to a small region along the antenna of a microwave ablator. Careful monitoring and controlling the lesion formation process is essential for successful microwaves and HIFU thermal ablations.

journal_name

Med Phys

journal_title

Medical physics

authors

Chen WS,Wu CC,Fang HY,Liu HL

doi

10.1118/1.2193689

subject

Has Abstract

pub_date

2006-05-01 00:00:00

pages

1346-51

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

33

pub_type

杂志文章
  • SU-E-T-567: Improve Dose Conformity with IMRT Using Shorter Source to Tumor Distance.

    abstract:PURPOSE:To reduce the potential of late toxicity (tissue necrosis and cognitive function loss) from brain radiotherapy, we studied a novel planning technique for MLC-equipped linear accelerators (LINACS) that reduces the high doses delivered outside the PTV, enhancing radiation dose conformity. METHODS:The feasibility...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735656

    authors: Yang W,Sandler H,Fraass B

    更新日期:2012-06-01 00:00:00

  • SU-E-T-210: Surviving a Visit by the Radiological Physics Center.

    abstract:PURPOSE:To demonstrate an objective approach to determining if a negative report from the Radiological Physics Center (RPC) of greater than 10% error is valid or has clinical significance. METHODS:The discrepancy involved the clinical activity (mgRaEq) of Cs-137 sources, some manufactured by 3M and some by Amersham. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735271

    authors: Grant W 3rd,Mcgary J,Rosen I,Nitsch P,Davidson S

    更新日期:2012-06-01 00:00:00

  • Absorbed-dose beam quality conversion factors for cylindrical chambers in high energy photon beams.

    abstract::Recent working groups of the AAPM [Almond et al., Med. Phys. 26, 1847 (1999)] and the IAEA (Andreo et al., Draft V.7 of "An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water," IAEA, 2000) have described guidelines to base reference dosimetry of high energy photon beams on absorb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1328081

    authors: Seuntjens JP,Ross CK,Shortt KR,Rogers DW

    更新日期:2000-12-01 00:00:00

  • SU-E-J-170: Clinical Evaluation of Positioning Accuracy of Two Immobilization Devices for Stereotactic Body Radiotherapy Using Cone Beam CT.

    abstract:PURPOSE:To evaluate the patient positioning accuracy and reproducibility of two commercially available immobilization systems for Stereotactic Body Radiotherapy (SBRT) treatment. METHODS:Forty one patients with lung (n=21) or liver (n=20) malignancies were assigned to one of the two immobilization devices: Elekta ster...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735009

    authors: Cao M,Cao N,Cardenes H,Fakiris A,Desrosiers C,Das I

    更新日期:2012-06-01 00:00:00

  • Deadtime correction for two multihead Anger cameras in 131I dual-energy-window-acquisition mode.

    abstract::Two side-by-side energy windows, one at the photopeak and one at lower energy, are sometimes employed in quantitative SPECT studies. We measured the count-rate losses at moderately high activities of 131I for two multihead Anger cameras in such a dual-window-acquisition mode by imaging a decaying source composed of tw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598162

    authors: Koral KF,Zasadny KR,Ackermann RJ,Ficaro EP

    更新日期:1998-01-01 00:00:00

  • Maximum likelihood estimation of proton irradiated field and deposited dose distribution.

    abstract::In proton therapy, it is important to evaluate the field irradiated with protons and the deposited dose distribution in a patient's body. Positron emitters generated through fragmentation reactions of target nuclei can be used for this purpose. By detecting the annihilation gamma rays from the positron emitters, the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2712572

    authors: Inaniwa T,Kohno T,Yamagata F,Tomitani T,Sato S,Kanazawa M,Kanai T,Urakabe E

    更新日期:2007-05-01 00:00:00

  • An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams.

    abstract::In this work, the authors have evaluated ten different ionization chambers for the relative dosimetry of kilovoltage x-ray beams in the energy range of 50-280 kVp. Percentage depth doses in water and relative detector response (in Solid Water and in air) were measured for each of the x-ray beams studied using a number...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3183820

    authors: Hill R,Mo Z,Haque M,Baldock C

    更新日期:2009-09-01 00:00:00

  • Impact of transverse magnetic fields on dose response of a radiophotoluminescent glass dosimeter in megavoltage photon beams.

    abstract:PURPOSE:The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. METHODS:The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14054

    authors: Ito S,Araki F,Ohno T

    更新日期:2020-04-01 00:00:00

  • Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy.

    abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2794175

    authors: Surry KJ,Mills GR,Bevan K,Downey DB,Fenster A

    更新日期:2007-11-01 00:00:00

  • SU-C-218-06: Evaluation of a CT-Based, Semi-Automated Lung Mass Estimation Method Under Varying Acquisition Conditions.

    abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734654

    authors: Busse N,Erwin W,Pan T

    更新日期:2012-06-01 00:00:00

  • Poster - Thur Eve - 64: Evaluation of SmartArc and RapidArc for lung SBRT treatment planning and delivery.

    abstract:OBJECTIVES:To evaluate the performance of RapidArc® (Eclipse 10.0.28) and SmartArc® (Pinnacle 9.0) radiotherapy plans for lung stereotactic body radiation therapy (SBRT) in terms of dosimetric plan quality, delivery efficiency, inhomogeneity corrections and accuracy of dose delivery using a custom-built heterogeneity i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740172

    authors: Fakir H,Hoover D,Chen JZ

    更新日期:2012-07-01 00:00:00

  • SU-E-T-96: Energy Dependence of the New GafChromic- EBT3 Film's Dose Response-Curve.

    abstract:PURPOSE:To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. METHODS:Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735153

    authors: Chiu-Tsao S,Massillon-Jl G,Domingo-Muñoz I,Chan M

    更新日期:2012-06-01 00:00:00

  • Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization.

    abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477230

    authors: Siebers JV,Lauterbach M,Keall PJ,Mohan R

    更新日期:2002-06-01 00:00:00

  • A phantom for visualization of three-dimensional drug release by ultrasound-induced mild hyperthermia.

    abstract:PURPOSE:Ultrasound-induced mild hyperthermia has advantages for noninvasive, localized and controlled drug delivery. In this study, a tissue-mimicking agarose-based phantom with a thermally sensitive indicator was developed for studying the spatial drug delivery profile using ultrasound-induced mild hyperthermia. METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813299

    authors: Lai CY,Kruse D,Seo JW,Kheirolomoom A,Ferrara KW

    更新日期:2013-08-01 00:00:00

  • Dental enamel as an in vivo radiation dosimeter.

    abstract::The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue whi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595768

    authors: Pass B,Aldrich JE

    更新日期:1985-05-01 00:00:00

  • Dosimetric effects of contrast media for catheter-based intravascular brachytherapy.

    abstract::The purpose of this work is to calculate the dose perturbations due to the presence of iodine contrast media in catheter-based intravascular brachytherapy (IVBT). The EGSnrc Monte Carlo system was used to perform the calculation for the two most commonly used beta and gamma sources (90Sr and 192Ir as well as for a var...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1367279

    authors: Li XA

    更新日期:2001-05-01 00:00:00

  • Low-dose CT reconstruction using spatially encoded nonlocal penalty.

    abstract:PURPOSE:Computed tomography (CT) is one of the most used imaging modalities for imaging both symptomatic and asymptomatic patients. However, because of the high demand for lower radiation dose during CT scans, the reconstructed image can suffer from noise and artifacts due to the trade-off between the image quality and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12523

    authors: Kim K,El Fakhri G,Li Q

    更新日期:2017-10-01 00:00:00

  • Design and evaluation of an MRI-compatible linear motion stage.

    abstract:PURPOSE:To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS:In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4937780

    authors: Tavallaei MA,Johnson PM,Liu J,Drangova M

    更新日期:2016-01-01 00:00:00

  • Broadband lung dielectric properties over the ablative temperature range: Experimental measurements and parametric models.

    abstract:PURPOSE:Computational models of microwave tissue ablation are widely used to guide the development of ablation devices, and are increasingly being used for the development of treatment planning and monitoring platforms. Knowledge of temperature-dependent dielectric properties of lung tissue is essential for accurate mo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13704

    authors: Sebek J,Bortel R,Prakash P

    更新日期:2019-10-01 00:00:00

  • A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration.

    abstract:PURPOSE:In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. How...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3697524

    authors: Hub M,Thieke C,Kessler ML,Karger CP

    更新日期:2012-04-01 00:00:00

  • A scanning system for chest radiography with regional exposure control: theoretical considerations.

    abstract::Conventional chest radiography is limited by the presence of scattered radiation and the small useful exposure range of radiographic film. A computer-assisted scanning system to minimize these two effects is outlined. The system uses a small beam of radiation swept over the patient's chest in a raster pattern to expos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595327

    authors: Plewes DB

    更新日期:1983-09-01 00:00:00

  • Iodine quantification in limited angle tomography.

    abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14400

    authors: Michielsen K,Rodríguez-Ruiz A,Reiser I,Nagy JG,Sechopoulos I

    更新日期:2020-10-01 00:00:00

  • A CdZnTe slot-scanned detector for digital mammography.

    abstract::A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1523932

    authors: Mainprize JG,Ford NL,Yin S,Gordon EE,Hamilton WJ,Tümer TO,Yaffe MJ

    更新日期:2002-12-01 00:00:00

  • Exposure artifacts in raster scanned equalization radiography.

    abstract::The image artifacts characteristic of a scanning chest radiographic system are reviewed. The technique employs a pulsed beam of radiation swept in an overlapping raster pattern that can result in severe ripple and scan line artifacts with improper scanning parameters. A one-dimensional treatment of the scanner geometr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595492

    authors: Plewes DB,Vogelstein E

    更新日期:1984-03-01 00:00:00

  • SU-E-J-186: CT Textures Can be Predictive for Tumor Shrinkage.

    abstract:PURPOSE:To determine if NSCLC GTV CT textures can be predictive for tumor shrinkage after proton therapy with concurrent chemotherapy. METHODS:Simulation and weekly 4DCTs were obtained from 25 patients with locally advanced NSCLC treated by proton therapy at a 74 Gy dose level with concurrent chemotherapy. In-house de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735027

    authors: Hunter L,Chen Y,Zhang L,Liao Z,Dong L,Court L

    更新日期:2012-06-01 00:00:00

  • Dose distributions around cylindrical 241Am sources for a clinical intracavitary applicator.

    abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596007

    authors: Nath R,Gray L,Park CH

    更新日期:1987-09-01 00:00:00

  • Experimental determination of the "collimator monitoring fill factor" and its relation to the error detection capabilities of various 2D-arrays.

    abstract:PURPOSE:The collimator monitoring fill factor (CM-FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM-FF) introduced by Gago-Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D-arrays. The error detection capabilities of 2D-arrays were studied by co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13417

    authors: Stelljes TS,Poppinga D,Kretschmer J,Brodbek L,Looe HK,Poppe B

    更新日期:2019-04-01 00:00:00

  • On calculating kerma, collision kerma and radiative yields.

    abstract:PURPOSE:To study the relationships between dose (D), kerma (K), and collision kerma ( K col ) in photon beams and to investigate total radiative yields for electrons and positrons as a functio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13744

    authors: Rogers DWO,Townson RW

    更新日期:2019-11-01 00:00:00

  • A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention.

    abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148834

    authors: Yan K,Li L,Joseph J,Rubens DR,Messing EM,Liao L,Yu Y

    更新日期:2009-07-01 00:00:00

  • Absorbed dose in the presence of contrast agents during pediatric cardiac catheterization.

    abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594613

    authors: Callisen HH,Norman A,Adams FH

    更新日期:1979-11-01 00:00:00