Abstract:
:To achieve increased image acquisition speed or better image quality, several read-out methods for a matrix ionization chamber system have been investigated. In this device, which is applied for portal imaging in radiation therapy, 256 x 256 small liquid-filled ionization chambers are scanned by switching the polarizing voltage applied to rows of chambers. The ionization current of each column is measured by a separate amplifier. In this approach, instead of measuring row by row, more complex switching schemes can be applied for the polarizing voltage. These schemes are useful either for varying speed and spatial resolution of the imaging device or for coded sampling of the ionization signal. The former option allows for doubling or quadrupling the acquisition speed with a small loss in image quality, or for obtaining a large improvement in signal-to-noise ratio at the cost of image resolution. In the latter option, coded sampling, the image is reconstructed mathematically from the measured signals. It is shown that in this case the application of Hadamard or derived matrices for sampling leads, under certain circumstances, to a noise reduction in the reconstructed image.
journal_name
Med Physjournal_title
Medical physicsauthors
van Herk M,Bijhold J,Hoogervorst B,Meertens Hdoi
10.1118/1.596829subject
Has Abstractpub_date
1992-03-01 00:00:00pages
409-18issue
2eissn
0094-2405issn
2473-4209journal_volume
19pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2161404
更新日期:2006-02-01 00:00:00
abstract::A conceptual design is presented showing that, by judiciously choosing the beryllium target thickness and the backstop material, improvements can be achieved in dose-rate, skin sparing, and penetration of neutron beams generated by the same proton accelerator. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594748
更新日期:1980-09-01 00:00:00
abstract::Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical pra...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1562491
更新日期:2003-04-01 00:00:00
abstract:PURPOSE:To develop a fluoroscopy imaging based approach that can determine the magnitude and phase variation in respiratory motion against the treatment planning images in order to quantify the online patient setup deviation in thoracic cancer IGRT for the real time adaptive patient positionadjustment. METHODS:A numer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734876
更新日期:2012-06-01 00:00:00
abstract::The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric effects were studied considering the breathing pattern of three patients monitored during the course of their treatment ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2821704
更新日期:2008-01-01 00:00:00
abstract:PURPOSE:Material-specific imaging and virtual monochromatic imaging/analysis are the two forms of spectral imaging in CT implemented via either energy-integration or photon-counting data acquisition. Aimed at further understanding the fundamentals and providing guidelines on its design and implementation, we quantitati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14708
更新日期:2021-01-07 00:00:00
abstract::Due to practical limitations in data acquisition, 3-D computed tomography systems must attempt to provide rapid reconstructions of acceptable quality from a limited number of views. The use of convolution backprojection (CBP) for image reconstruction from an inadequate number of projections, results in view aliasing a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598606
更新日期:1999-06-01 00:00:00
abstract:PURPOSE:To demonstrate an objective approach to determining if a negative report from the Radiological Physics Center (RPC) of greater than 10% error is valid or has clinical significance. METHODS:The discrepancy involved the clinical activity (mgRaEq) of Cs-137 sources, some manufactured by 3M and some by Amersham. M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735271
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) is one of the most used imaging modalities for imaging both symptomatic and asymptomatic patients. However, because of the high demand for lower radiation dose during CT scans, the reconstructed image can suffer from noise and artifacts due to the trade-off between the image quality and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12523
更新日期:2017-10-01 00:00:00
abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1286591
更新日期:2000-08-01 00:00:00
abstract::In order to use negative pions for the treatment of large deep-seated tumors in radiotherapy, it is necessary to produce depth-dose distributions tailored to specific shapes. We present here a method of beam shaping which utilizes a fluid-filled piston having a programmable, computer-controlled, time-dependent thickne...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594313
更新日期:1977-09-01 00:00:00
abstract:PURPOSE:To achieve more translatable preclinical research results, small animal irradiation needs to more closely simulate human radiotherapy. Although the clinical gold standard is intensity-modulated radiation therapy (IMRT), the direct translation of this method for small animals is impractical. In this study we des...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13872
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:Polymer-based gel dosimeter (MAGIC type) is a preferable phantom material for PET range verification of proton beam therapy. However, improvement in elemental tissue equivalency (specifically O/C ratio) is very desirable to ensure realistic time-activity measurements. METHODS:Glucose and urea was added to the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3260844
更新日期:2010-01-01 00:00:00
abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597307
更新日期:1994-03-01 00:00:00
abstract::Magnetic resonance images can be compromised by constant frequency (CF) noise, such as radio frequency (RF) noise. We investigate the effects of CF noise in four imaging methods with non-uniform k-space sampling: single-shot echo-planar imaging (EPI) with sinusoidal readout gradients, phase-encoded echo-planar spectro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1496096
更新日期:2002-08-01 00:00:00
abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12285
更新日期:2017-09-01 00:00:00
abstract::Separation of water from fat tissues in magnetic resonance imaging is important for many applications because signals from fat tissues often interfere with diagnoses that are usually based on water signal characteristics. Water and fat can be separated with images acquired at different echo time shifts. The three-poin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2952644
更新日期:2008-08-01 00:00:00
abstract::Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2775667
更新日期:2007-10-01 00:00:00
abstract:PURPOSE:Urinary particles are particularly important parameters in clinical urinalysis, especially for the diagnosis of nephropathy. Therefore, it is highly important to precisely detect urinary particles in the clinical setting. However, artificial microscopy is subjective and time consuming, and various previous dete...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14118
更新日期:2020-07-01 00:00:00
abstract::Carlo Fidani Peel Regional Cancer Center at the Credit Valley Site of the Credit Valley Hospital and Trillium Health Center is currently undergoing a redevelopment to build a brachytherapy suite and associated areas with a projected start date of April 2013. The new brachytherapy suite will be located in the PRCC, and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740117
更新日期:2012-07-01 00:00:00
abstract::New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applicat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2837288
更新日期:2008-03-01 00:00:00
abstract:PURPOSE:Several new technologies for single photon emission computed tomography (SPECT) instrumentation with parallel-hole collimation have been proposed to improve detector sensitivity and signal collection efficiency. Benefits from improved signal efficiency include shorter acquisition times and lower dose requiremen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4897567
更新日期:2014-11-01 00:00:00
abstract::Frequent and repeated imaging procedures such as those performed in image-guided radiotherapy (IGRT) programs may add significant dose to radiosensitive organs of radiotherapy patients. It has been shown that kV-CBCT results in doses to bone that are up to a factor of 3-4 higher than those in surrounding soft tissue. ...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3014197
更新日期:2008-12-01 00:00:00
abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4964454
更新日期:2016-11-01 00:00:00
abstract::We employed an elastic reservoir filled with tissue-equivalent fluid as an x-ray beam filter for exposure equalization. The filter is designed to be placed between the upper compression plate and the breast. During compression, it will conform to the shape of the peripheral region of the breast and fill the space betw...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596502
更新日期:1990-03-01 00:00:00
abstract:PURPOSE:Imaging the knee under realistic load-bearing conditions can be carried out in a horizontal plane using a C-arm CT scanner. Human subjects can be scanned in a standing position and acquired data successfully reconstructed. However, reconstructing this data is a challenge due to significant artifacts that are in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736213
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Couch-mounted cone-beam computed tomography (CBCT) imaging devices with independently rotatable x-ray source and flat-panel detector arms for acquisitions of arbitrary regions of interest (ROI) have recently been introduced in image-guided radiotherapy (IGRT). This work analyzes mechanical limitations and gravi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12033
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with du...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736809
更新日期:2012-08-01 00:00:00
abstract::A computationally efficient pseudodynamical filtering setup is established for elasticity imaging (i.e., reconstruction of shear modulus distribution) in soft-tissue organs given statically recorded and partially measured displacement data. Unlike a regularized quasi-Newton method (QNM) that needs inversion of ill-con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3158808
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:Myocardial infarct (MI) may consist of an infarct core (IC) and a heterogeneous, semi-viable border zone (BZ). Patients with chronic MI in the left ventricular (LV) myocardium are at increased risk of developing ventricular arrhythmias, and may therefore qualify for implantable cardioverter defibrillator (ICD) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12840
更新日期:2018-04-01 00:00:00