Poster - Thur Eve - 09: Novel radiation safety challenges of a brachytherapy redevelopment at the Credit Valley Hospital.

Abstract:

:Carlo Fidani Peel Regional Cancer Center at the Credit Valley Site of the Credit Valley Hospital and Trillium Health Center is currently undergoing a redevelopment to build a brachytherapy suite and associated areas with a projected start date of April 2013. The new brachytherapy suite will be located in the PRCC, and is a redevelopment of office area into clinical space. The workload for the full brachytherapy program is expected to be 20 patients per week, in cervix, prostate, skin, lung and other sites. There were challenges for shielding due services in the slab to the renal clinic located above the redevelopment area. The presence of over 30 voids in the slab and upper walls made the solution to add shielding to the underside of the current slab unsuitable. To overcome this, a second ceiling built below the slab to allow for an uninterrupted shielding for the brachytherapy suite. The additional ceiling allows for a crawl space between slab and shielding allowing for servicing if needed for the drains from the renal clinic. The appropriate finalized shielding design is 69mm of lead brick supported by steel plate and steel beams. Final shielding for the walls is 690mm of concrete that allows public access to all hallways around the facility. The final design for the new brachytherapy site at the PRCC all services for the room are located within the shielding and all services for areas outside the room are located outside the shielding.

journal_name

Med Phys

journal_title

Medical physics

authors

Nielsen M,Sankreacha R,MacPherson M

doi

10.1118/1.4740117

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

4625-4626

issue

7Part2

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Electron disequilibrium in high-energy x-ray beams.

    abstract::The ratio between scatter dose and scatter kerma for points on the central axis of 15-MV x-ray beams has been examined by Monte Carlo calculations. This ratio, beta'S, behaves differently from that between the primary dose and kerma, beta'p. Both the primary and scatter components of beta' undergo an initial rapid bui...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597749

    authors: Hannallah D,Zhu TC,Bjärngard BE

    更新日期:1996-11-01 00:00:00

  • Electron dose calculation using multiple-scattering theory. A. Gaussian multiple-scattering theory.

    abstract::This article is the first in a series on the calculation of electron dose using multiple-scattering theory. In it we develop a unified theory, which we term Gaussian multiple-scattering theory, starting from a number of contributions already in the literature: the Fermi-Eyges multiple-scattering theory, the Yang path ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596166

    authors: Jette D

    更新日期:1988-03-01 00:00:00

  • Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.

    abstract::The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous sil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2147744

    authors: Wendling M,Louwe RJ,McDermott LN,Sonke JJ,van Herk M,Mijnheer BJ

    更新日期:2006-02-01 00:00:00

  • Robotic intrafractional US guidance for liver SABR: System design, beam avoidance, and clinical imaging.

    abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964454

    authors: Schlosser J,Gong RH,Bruder R,Schweikard A,Jang S,Henrie J,Kamaya A,Koong A,Chang DT,Hristov D

    更新日期:2016-11-01 00:00:00

  • Quantitative impact of changes in marrow cellularity, skeletal size, and bone mineral density on active marrow dosimetry based upon a reference model.

    abstract:PURPOSE:The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three-dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12002

    authors: Geyer AM,Schwarz BC,Hobbs RF,Sgouros G,Bolch WE

    更新日期:2017-01-01 00:00:00

  • Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects.

    abstract:PURPOSE:To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. METHODS:In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930798

    authors: Bouchard H,Kamio Y,Palmans H,Seuntjens J,Duane S

    更新日期:2015-10-01 00:00:00

  • Poster - Thurs Eve-04: Mathematical modeling of liver metastases tumour growth and control with radiotherapy.

    abstract::Generating an optimized radiation treatment plan requires understanding the factors affecting tumour control. Mathematical models of tumour dynamics may help in future studies of factors predicting tumor sensitivity to radiotherapy. In this study, a time-dependent differential model, incorporating biological cancer ma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965923

    authors: Campbell A,Davidson M,Lock M,Wong E

    更新日期:2008-07-01 00:00:00

  • A sparse orthogonal collimator for small animal intensity-modulated radiation therapy part I: Planning system development and commissioning.

    abstract:PURPOSE:To achieve more translatable preclinical research results, small animal irradiation needs to more closely simulate human radiotherapy. Although the clinical gold standard is intensity-modulated radiation therapy (IMRT), the direct translation of this method for small animals is impractical. In this study we des...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13872

    authors: Woods K,Nguyen D,Neph R,Ruan D,O'Connor D,Sheng K

    更新日期:2019-12-01 00:00:00

  • Dosimetric characteristics of Novalis shaped beam surgery unit.

    abstract::The dosimetric characteristics of a new dedicated radiosurgical treatment unit are systematically measured in terms of its percent depth dose, beam profile, and relative scatter factor. High-resolution diode detector, mini-ion-chamber detector, and conventional Kodak XV films are used to measure dosimetric data for a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1494830

    authors: Yin FF,Zhu J,Yan H,Gaun H,Hammoud R,Ryu S,Kim JH

    更新日期:2002-08-01 00:00:00

  • Determination of exit skin dose for 192Ir intracavitary accelerated partial breast irradiation with thermoluminescent dosimeters.

    abstract:PURPOSE:Intracavitary accelerated partial breast irradiation (APBI) has become a popular treatment for early stage breast cancer in recent years due to its shortened course of treatment and simplified treatment planning compared to traditional external beam breast conservation therapy. However, the exit dose to the ski...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3429089

    authors: Raffi JA,Davis SD,Hammer CG,Micka JA,Kunugi KA,Musgrove JE,Winston JW Jr,Ricci-Ott TJ,DeWerd LA

    更新日期:2010-06-01 00:00:00

  • Temporal stability assessment in shear wave elasticity images validated by deep learning neural network for chronic liver disease fibrosis stage assessment.

    abstract:PURPOSE:To automatically detect and isolate areas of low and high stiffness temporal stability in shear wave elastography (SWE) image sequences and define their impact in chronic liver disease (CLD) diagnosis improvement by means of clinical examination study and deep learning algorithm employing convolutional neural n...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13521

    authors: Gatos I,Tsantis S,Spiliopoulos S,Karnabatidis D,Theotokas I,Zoumpoulis P,Loupas T,Hazle JD,Kagadis GC

    更新日期:2019-05-01 00:00:00

  • Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system.

    abstract:PURPOSE:The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. METHODS:They equipped a research Siemens Artiste linear a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3665712

    authors: Fast MF,Krauss A,Oelfke U,Nill S

    更新日期:2012-01-01 00:00:00

  • Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

    abstract:PURPOSE:Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review a...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12810

    authors: Miften M,Olch A,Mihailidis D,Moran J,Pawlicki T,Molineu A,Li H,Wijesooriya K,Shi J,Xia P,Papanikolaou N,Low DA

    更新日期:2018-04-01 00:00:00

  • A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy.

    abstract:PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12459

    authors: Ma Y,Vijande J,Ballester F,Tedgren ÅC,Granero D,Haworth A,Mourtada F,Fonseca GP,Zourari K,Papagiannis P,Rivard MJ,Siebert FA,Sloboda RS,Smith R,Chamberland MJP,Thomson RM,Verhaegen F,Beaulieu L

    更新日期:2017-11-01 00:00:00

  • Accurate measurement of characteristic curves of II-TV digital systems by use of aluminum stepwedge technique.

    abstract::In order to determine accurately the relative x-ray intensities transmitted through the different steps of an aluminum stepwedge and incident on an image intensifier (II)-TV digital system, we used a 100-mm camera which was attached to the II output. The characteristic curves of an II-TV digital system, which relate t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595819

    authors: Fujita H,Doi K

    更新日期:1986-11-01 00:00:00

  • A clinically feasible method for the detection of potential collision in proton therapy.

    abstract:PURPOSE:Potential collision between the patient∕couch and the gantry could delay the start of the treatment and reduce clinical efficiency. The ability to accurately detect possible collisions during the treatment planning phase is desired. Such collision detection should account for the specific proton gantry design, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4760988

    authors: Zou W,Lin H,Plastaras JP,Wang H,Bui V,Vapiwala N,McDonough J,Tochner Z,Both S

    更新日期:2012-11-01 00:00:00

  • Skeletal dosimetry for external exposures to photons based on microCT images of spongiosa: consideration of voxel resolution, cluster size, and medullary bone surfaces.

    abstract::Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skele...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3242266

    authors: Kramer R,Khoury HJ,Vieira JW,Robson Brown KA

    更新日期:2009-11-01 00:00:00

  • Pulmonary nodule detection in CT images based on shape constraint CV model.

    abstract:PURPOSE:Accurate detection of pulmonary nodules remains a technical challenge in computer-aided diagnosis systems because some nodules may adhere to the blood vessels or the lung wall, which have low contrast compared to the surrounding tissues. In this paper, the analysis of typical shape features of candidate nodules...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4907961

    authors: Wang B,Tian X,Wang Q,Yang Y,Xie H,Zhang S,Gu L

    更新日期:2015-03-01 00:00:00

  • Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach.

    abstract:PURPOSE:The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior-inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4899185

    authors: Zhang Y,Wu X,Yang W,Feng Q,Chen W

    更新日期:2014-11-01 00:00:00

  • Normalized dose data for upper gastrointestinal tract contrast studies performed to infants.

    abstract::The aim of the current study was to (a) provide normalized dose data for the estimation of the radiation dose from upper gastrointestinal tract contrast (UGIC) studies carried out to infants and (b) estimate the average patient dose and risks associated with radiation from UGIC examinations performed in our institutio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2181297

    authors: Damilakis J,Stratakis J,Raissaki M,Perisinakis K,Kourbetis N,Gourtsoyiannis N

    更新日期:2006-04-01 00:00:00

  • Age-dependent dose calculations for common PET radionuclides and brain radiotracers in nonhuman primate computational models.

    abstract:PURPOSE:The combination of nonhuman primates (NHPs) with the state-of-the-art molecular imaging technologies allows for within-subject longitudinal research aiming at gaining new insights into human normal and disease conditions and provides an ideal foundation for future translational studies of new diagnostic tools, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14333

    authors: Xie T,Chen X,Zaidi H

    更新日期:2020-09-01 00:00:00

  • Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

    abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823795

    authors: McMillan K,McNitt-Gray M,Ruan D

    更新日期:2013-11-01 00:00:00

  • X-ray-transmission computed tomography.

    abstract::The immediate goal of clinically based x-ray-transmission computed tomography (CT) is to provide a measurement of the x-ray linear attenuation coefficient in cross section with the ultimate goal of impacting on patient management and care. To do this with the accuracy needed for clinical goals requires the careful int...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.594381

    authors: McCullough EC,Payne JT

    更新日期:1977-03-01 00:00:00

  • Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.

    abstract::Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing nov...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4941014

    authors: Mehranian A,Arabi H,Zaidi H

    更新日期:2016-03-01 00:00:00

  • Lag measurement in an a-Se active matrix flat-panel imager.

    abstract::Lag and residual contrast have been quantified in an amorphous selenium (a-Se) active-matrix flat-panel imager (AMFPI) as a function of frame time, kilovoltage (kV) and megavoltage (MV) x-ray photon energies and amount of radiation incident on the detector. The AMFPI contains a 200 microm thick a-Se layer deposited on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1713298

    authors: Schroeder C,Stanescu T,Rathee S,Fallone BG

    更新日期:2004-05-01 00:00:00

  • A scintillator-based approach to monitor secondary neutron production during proton therapy.

    abstract:PURPOSE:The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4963813

    authors: Clarke SD,Pryser E,Wieger BM,Pozzi SA,Haelg RA,Bashkirov VA,Schulte RW

    更新日期:2016-11-01 00:00:00

  • Verification of absorbed dose determined with plane-parallel chambers in clinical electron beams following AAPM Task Group 39 protocol using ferrous sulphate dosimetry.

    abstract::The absorbed dose values determined with the Exradin and PTW-Markus plane-parallel chambers were compared to the values obtained with the ferrous sulphate dosimetry for a number of the Philips SL25 and the Therac 20 electron beams. For the plane-parallel chambers, the cavity-gas calibration factor Ngaspp, was derived ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597800

    authors: Xu Z,Li H,Almond PR,Guan TY

    更新日期:1996-03-01 00:00:00

  • Dosimetry for 252Cf neutron emitting brachytherapy sources: protocol, measurements, and calculations.

    abstract::The mixed-field dosimetry for 252Cf Applicator Tube (AT) type medical sources available from Oak Ridge National Laboratory (ORNL) has been characterized using ionization chambers, a GM counter, and Monte Carlo methods. Unlike the AAPM Task Group No. 43 (TG-43), specification of dose to muscle instead of water is recom...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598646

    authors: Rivard MJ

    更新日期:1999-08-01 00:00:00

  • Poster - Thur Eve - 66: A planning comparison between RapidArc and intensity modulated radiotherapy for head and neck cancer.

    abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740174

    authors: Jiang R,Fleck A,Schaly B,Charland P,Zhan L,Alliet K,Rachakonda R,Osei E

    更新日期:2012-07-01 00:00:00

  • SU-E-T-231: Comparison of Beam Characteristics of Small Field 6 MeV Electrons as Replacement for Superficial X Ray Beam.

    abstract:PURPOSE:To compare beam characteristics of superficial X-rays with 6 MeV Electrons for the purpose of replacing superficial treatments with electron fields for skin lesions. METHODS:Electron beam cutouts were made with 12mm thickness cerrobend in diameters 2-5 cm to match superficial X-ray machine cones. Central axis ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735294

    authors: Avadhani J,Sasidharan S,Carton C,Lowen M,Klapproth T,Licitra C