A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy.

Abstract:

PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and comparisons with model-based dose calculation algorithms (MBDCAs). Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR) 192 Ir shielded applicator has been designed and benchmarked. METHODS:A generic HDR 192 Ir shielded applicator was designed based on three commercially available gynecological applicators as well as a virtual cubic water phantom that can be imported into any DICOM-RT compatible treatment planning system (TPS). The absorbed dose distribution around the applicator with the TG-186 192 Ir source located at one dwell position at its center was computed using two commercial TPSs incorporating MBDCAs (Oncentra® Brachy with Advanced Collapsed-cone Engine, ACE™, and BrachyVision ACUROS™) and state-of-the-art Monte Carlo (MC) codes, including ALGEBRA, BrachyDose, egs_brachy, Geant4, MCNP6, and Penelope2008. TPS-based volumetric dose distributions for the previously reported "source centered in water" and "source displaced" test cases, and the new "source centered in applicator" test case, were analyzed here using the MCNP6 dose distribution as a reference. Volumetric dose comparisons of TPS results against results for the other MC codes were also performed. Distributions of local and global dose difference ratios are reported. RESULTS:The local dose differences among MC codes are comparable to the statistical uncertainties of the reference datasets for the "source centered in water" and "source displaced" test cases and for the clinically relevant part of the unshielded volume in the "source centered in applicator" case. Larger local differences appear in the shielded volume or at large distances. Considering clinically relevant regions, global dose differences are smaller than the local ones. The most disadvantageous case for the MBDCAs is the one including the shielded applicator. In this case, ACUROS agrees with MC within [-4.2%, +4.2%] for the majority of voxels (95%) while presenting dose differences within [-0.12%, +0.12%] of the dose at a clinically relevant reference point. For ACE, 95% of the total volume presents differences with respect to MC in the range [-1.7%, +0.4%] of the dose at the reference point. CONCLUSIONS:The combination of the generic source and generic shielded applicator, together with the previously developed test cases and reference datasets (available in the Brachytherapy Source Registry), lay a solid foundation in supporting uniform commissioning procedures and direct comparisons among treatment planning systems for HDR 192 Ir brachytherapy.

journal_name

Med Phys

journal_title

Medical physics

authors

Ma Y,Vijande J,Ballester F,Tedgren ÅC,Granero D,Haworth A,Mourtada F,Fonseca GP,Zourari K,Papagiannis P,Rivard MJ,Siebert FA,Sloboda RS,Smith R,Chamberland MJP,Thomson RM,Verhaegen F,Beaulieu L

doi

10.1002/mp.12459

subject

Has Abstract

pub_date

2017-11-01 00:00:00

pages

5961-5976

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

44

pub_type

杂志文章
  • On the uncertainties in effective dose estimates of adult CT head scans.

    abstract::Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2952359

    authors: Gregory KJ,Bibbo G,Pattison JE

    更新日期:2008-08-01 00:00:00

  • SU-E-I-16: Automated Liver Segmentation Method for CBCT Dataset by Probabilistic Atlas Construction.

    abstract:PURPOSE:The aiming is getting accurate liver contour structures automatically for following adaptive radiation therapy in daily CBCT images which is very low-contrast comparing the planning CT. METHODS:Probabilistic atlas is constructed by 50 intravenous contrast planning CT images by iterative affine registration pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734730

    authors: Li D,Li H,Yin Y,Chen J

    更新日期:2012-06-01 00:00:00

  • Dose-averaged LET calculation for proton track segments using microdosimetric Monte Carlo simulations.

    abstract:PURPOSE:There is an increasing interest in calculating linear energy transfer (LET) distributions for proton therapy treatments in order to assess the influence of this quantity in biological terms. Microdosimetric Monte Carlo (MC) simulations are useful tools to calculate dose-averaged LET, as this has been broadly pr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13643

    authors: Bertolet A,Baratto-Roldán A,Barbieri S,Baiocco G,Carabe A,Cortés-Giraldo MA

    更新日期:2019-09-01 00:00:00

  • Wavelength dependence of the precision of noninvasive optical measurement of oxy-, deoxy-, and total-hemoglobin concentration.

    abstract::The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser dio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1373401

    authors: Yamashita Y,Maki A,Koizumi H

    更新日期:2001-06-01 00:00:00

  • Optimization of power deposition and a heating strategy for external ultrasound thermal therapy.

    abstract::The purpose of this paper is to examine the thermal dose distribution, to configure the optimal absorbed power deposition, and to design an appropriate heating strategy for ultrasound thermal therapy. This work employs simulation programs, which are based on the transient bio-heat transfer equation and an ideal absorb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1406516

    authors: Lin WL,Liang TC,Yen JY,Liu HL,Chen YY

    更新日期:2001-10-01 00:00:00

  • Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation.

    abstract:PURPOSE:Intensity modulated proton therapy (IMPT) of head and neck (H&N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908223

    authors: Landry G,Nijhuis R,Dedes G,Handrack J,Thieke C,Janssens G,Orban de Xivry J,Reiner M,Kamp F,Wilkens JJ,Paganelli C,Riboldi M,Baroni G,Ganswindt U,Belka C,Parodi K

    更新日期:2015-03-01 00:00:00

  • A sparse representation-based radiomics for outcome prediction of higher grade gliomas.

    abstract:PURPOSE:Accurately predicting outcome (i.e., overall survival (OS) time) for higher grade glioma (HGG) has great clinical value and would provide optimized guidelines for treatment planning. Radiomics focuses on revealing underlying pathophysiological information in biomedical images for disease analysis and demonstrat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13288

    authors: Wu G,Shi Z,Chen Y,Wang Y,Yu J,Lv X,Chen L,Ju X,Chen Z

    更新日期:2019-01-01 00:00:00

  • Validation of reconstructed bremsstrahlung spectra between 6 MV and 25 MV from measured transmission data.

    abstract::We have previously investigated a method of high-energy x-ray spectral reconstruction from transmission data by direct resolution of a matrix system. This technique uses the spectral vectorial algebra formalism. The resolution has previously been tested on a 12 MV photon beam. To extend and to test the validity of the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597998

    authors: Francois P,Coste F,Bonnet J,Caselles O

    更新日期:1997-05-01 00:00:00

  • On the efficiency of photon beam treatment head simulations.

    abstract::The paper presents a theoretical derivation of the photon fluence simulation efficiency in photon beam treatment head simulations without and with bremsstrahlung splitting. The expressions obtained provide a rigorous explanation of the efficiency dependence on scoring zone size and splitting number and explain the lar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1943808

    authors: Kawrakow I

    更新日期:2005-07-01 00:00:00

  • Variability of tumor area measurements for response assessment in malignant pleural mesothelioma.

    abstract:PURPOSE:The measurement of malignant pleural mesothelioma is critical to the assessment of tumor response to therapy. Current response assessment standards utilize summed linear measurements acquired on three computed tomography (CT) sections. The purpose of this study was to evaluate manual area measurements as an alt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810940

    authors: Labby ZE,Straus C,Caligiuri P,MacMahon H,Li P,Funaki A,Kindler HL,Armato SG 3rd

    更新日期:2013-08-01 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • Positional radiotherapy beam dosimetry using a laser heated thermoluminescent plate.

    abstract::A 4-W, laser-based system for the positional readout of thermoluminescent (TL) plates was utilized to obtain dose profiles for a 60Co radiotherapy beam. Experimentally obtained glow curves for LiF resulting from the rapid heating rates characteristic of laser heating agreed well with results predicted using a first-or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596580

    authors: Kearfott KJ,Grupen-Shemansky ME

    更新日期:1990-05-01 00:00:00

  • A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours.

    abstract::To more accurately and precisely delineate a tumor in a 3D PET image, we proposed a novel, semi-automatic, two-stage method by utilizing an adaptive region-growing algorithm and a dual-front active contour model. First, a rough region of interest (ROI) is manually drawn by a radiation oncologist that encloses a tumor....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2956713

    authors: Li H,Thorstad WL,Biehl KJ,Laforest R,Su Y,Shoghi KI,Donnelly ED,Low DA,Lu W

    更新日期:2008-08-01 00:00:00

  • A template-based approach to semi-quantitative SPECT myocardial perfusion imaging: Independent of normal databases.

    abstract:PURPOSE:Normal patient databases (NPDs) are used to distinguish between normal and abnormal perfusion in SPECT myocardial perfusion imaging (MPI) and have gained wide acceptance in the clinical environment, yet there are limitations to this approach. This study introduces a template-based method for semi-quantitative M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3595112

    authors: Hughes T,Shcherbinin S,Celler A

    更新日期:2011-07-01 00:00:00

  • Review and evaluation of MRI nonuniformity corrections for brain tumor response measurements.

    abstract::Current MRI nonuniformity correction techniques are reviewed and investigated. Many approaches are used to remedy this artifact, but it is not clear which method is the most appropriate in a given situation, as the applications have been with different MRI coils and different clinical applications. In this work four w...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.598357

    authors: Velthuizen RP,Heine JJ,Cantor AB,Lin H,Fletcher LM,Clarke LP

    更新日期:1998-09-01 00:00:00

  • Monte Carlo dose calculations for a new ovoid shield system for carcinoma of the uterine cervix.

    abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598459

    authors: Weeks KJ

    更新日期:1998-12-01 00:00:00

  • SU-E-T-558: Assessing the Effect of Inter-Fractional Motion in Esophageal Sparing Plans.

    abstract:PURPOSE:To compare esophageal dose distributions in esophageal sparing IMRT plans with predicted dose distributions which include the effect of inter-fraction motion. METHODS:Seven lung cancer patients were used, each with a standard and an esophageal sparing plan (74Gy, 2Gy fractions). The average max dose to esophag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735647

    authors: Williamson R,Bluett J,Niedzielski J,Liao Z,Gomez D,Court L

    更新日期:2012-06-01 00:00:00

  • Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets.

    abstract:PURPOSE:The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4916686

    authors: Rodriguez M,Sempau J,Brualla L

    更新日期:2015-06-01 00:00:00

  • Improvement of off-axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system.

    abstract:PURPOSE:Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Frei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12805

    authors: Jeevanandam P,Agnew CE,Irvine DM,McGarry CK

    更新日期:2018-04-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • Wedge-shaped dose distributions by computer-controlled collimator motion.

    abstract::We have recently installed a linear accelerator, modified to allow computer control of several machine parameters during irradiation of the patient. As an initial feasibility study of computer-controlled radiation therapy, its application to produce wedge-shaped dose distributions by moving the collimator jaws has bee...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594440

    authors: Kijewski PK,Chin LM,Bjärngard BE

    更新日期:1978-09-01 00:00:00

  • Characterization of trabecular bone plate-rod microarchitecture using multirow detector CT and the tensor scale: Algorithms, validation, and applications to pilot human studies.

    abstract:PURPOSE:Osteoporosis is a common bone disease associated with increased risk of low-trauma fractures leading to substantial morbidity, mortality, and financial costs. Clinically, osteoporosis is defined by low bone mineral density (BMD); however, increasing evidence suggests that trabecular bone (TB) microarchitectural...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928481

    authors: Saha PK,Liu Y,Chen C,Jin D,Letuchy EM,Xu Z,Amelon RE,Burns TL,Torner JC,Levy SM,Calarge CA

    更新日期:2015-09-01 00:00:00

  • A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT.

    abstract:PURPOSE:On-board MRI can provide superb soft tissue contrast for improving liver SBRT localization. However, the availability of on-board MRI in clinics is extremely limited. On the contrary, on-board kV imaging systems are widely available on radiotherapy machines, but its capability to localize tumors in soft tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12998

    authors: Harris W,Wang C,Yin FF,Cai J,Ren L

    更新日期:2018-07-01 00:00:00

  • Comparative performance of multiview stereoscopic and mammographic display modalities for breast lesion detection.

    abstract:PURPOSE:Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3562901

    authors: Webb LJ,Samei E,Lo JY,Baker JA,Ghate SV,Kim C,Soo MS,Walsh R

    更新日期:2011-04-01 00:00:00

  • Astigmatic single photon emission computed tomography imaging with a displaced center of rotation.

    abstract::A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598325

    authors: Wang H,Smith MF,Stone CD,Jaszczak RJ

    更新日期:1998-08-01 00:00:00

  • Determination of x-ray tube focal spot position.

    abstract::In x-ray spectral measurement using a semiconductor detector system, accurate positioning of the detector in front of the anode is very important. This needs accurate determination of the focal spot position on the target in an x-ray tube. We present a simple technique to determine the focal spot position accurately. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597122

    authors: Kubota H,Ozaki Y,Matsumoto M,Kanamori H

    更新日期:1993-07-01 00:00:00

  • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

    abstract::The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 microns pitch array of a-Si:H thin-film transistor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598243

    authors: Siewerdsen JH,Antonuk LE,el-Mohri Y,Yorkston J,Huang W,Cunningham IA

    更新日期:1998-05-01 00:00:00

  • Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

    abstract:PURPOSE:Dual-energy computed tomography and dual-energy cone-beam computed tomography (DE-CBCT) are promising modalities for applications ranging from vascular to breast, renal, hepatic, and musculoskeletal imaging. Accordingly, the optimization of imaging techniques for such applications would benefit significantly fr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736420

    authors: Gang GJ,Zbijewski W,Webster Stayman J,Siewerdsen JH

    更新日期:2012-08-01 00:00:00

  • Quantitative impact of changes in marrow cellularity, skeletal size, and bone mineral density on active marrow dosimetry based upon a reference model.

    abstract:PURPOSE:The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three-dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12002

    authors: Geyer AM,Schwarz BC,Hobbs RF,Sgouros G,Bolch WE

    更新日期:2017-01-01 00:00:00

  • Electron disequilibrium in high-energy x-ray beams.

    abstract::The ratio between scatter dose and scatter kerma for points on the central axis of 15-MV x-ray beams has been examined by Monte Carlo calculations. This ratio, beta'S, behaves differently from that between the primary dose and kerma, beta'p. Both the primary and scatter components of beta' undergo an initial rapid bui...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597749

    authors: Hannallah D,Zhu TC,Bjärngard BE

    更新日期:1996-11-01 00:00:00