Abstract:
PURPOSE:The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three-dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such a way that only a few reference skeletal models have been developed to date, and which are based upon microimaging of a limited number of cadaveric bone spongiosa cores. The question then arises as to what degree of accuracy is achievable from reference skeletal dose models when applied to individual patients or specific exposed populations? METHODS:Patient variability in marrow dosimetry were quantified for three skeletal sites - the ribs, lumbar vertebrae, and cranium - for the beta-emitters 45 Ca, 153 Sm, and 90 Y, and the alpha-particle emitters 223 Ra, 219 Rn, and 215 Po, the latter two being the immediate progeny of the former. For each radionuclide and bone site, three patient parameters were altered from their values in the reference model: (1) bone size as a surrogate for patient stature, (2) marrow cellularity as a surrogate for age- or disease-related changes in marrow adiposity, and (3) the trabecular bone volume fraction as a surrogate for bone mineral density. Marrow dose variability is expressed as percent differences in the radionuclide S value given by the reference model and the patient-parameterized model. The impact of radionuclide biokinetics on marrow dosimetry was not considered. RESULTS:Variations in overall bone size play a very minor role in active marrow dose variability. Marrow cellularity is a significant factor in dose variability for active marrow self-irradiation, but it plays no role for radionuclides localized to the trabecular bone matrix. Variations in trabecular bone volume fractions impact the active marrow dose variability for short-range particle emitters 45 Ca, 223 Ra, 219 Rn, and 215 Po in the vertebrae and ribs, skeletal sites with small spongiosa proportions of trabecular bone. In the cranium, with its relative high proportion of trabecular bone, significant differences in marrow dosimetry from the reference model were noted for all radionuclides. CONCLUSIONS:Skeletal models of active marrow dosimetry should be more fully parameterized to permit closer matching to patient bone density and marrow cellularity, particularly when considering short-range particle emitters localized to either the bone trabeculae or active marrow, respectively.
journal_name
Med Physjournal_title
Medical physicsauthors
Geyer AM,Schwarz BC,Hobbs RF,Sgouros G,Bolch WEdoi
10.1002/mp.12002subject
Has Abstractpub_date
2017-01-01 00:00:00pages
272-283issue
1eissn
0094-2405issn
2473-4209journal_volume
44pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805086
更新日期:2008-01-01 00:00:00
abstract::Reconstruction of electron spectra of medical accelerators from measured depth dose distributions is an attractive tool for commissioning of a Monte Carlo treatment planning system. However, the reconstruction method is an inverse radiation transport problem which is poorly conditioned, in the sense it may become unst...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1461840
更新日期:2002-04-01 00:00:00
abstract::Current edge detection methods used to determine coronary artery dimensions from digital (DSA) images suffer a strong dependence on the system's modulation transfer function (MTF). The videodensitometric algorithms are less sensitive to MTF blurring, yet still result in an overestimation of the vessel size of 10% to 2...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596370
更新日期:1989-03-01 00:00:00
abstract::Due to practical limitations such as inter- and intraleaf transmission, nondivergent leaf end design, and leaf scatter, multileaf collimators (MLCs) are unable to accurately produce the ideal fluence patterns generated by inverse planning systems. Consequently, low dose regions receive substantially more radiation tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2779862
更新日期:2007-10-01 00:00:00
abstract:PURPOSE:The Alvarez-Macovski method extracts the x-ray energy-dependent information by expanding the attenuation coefficient as a linear combination of functions of energy multiplied by basis set coefficients. Since the basis functions are known a priori, the coefficients represent all the energy-dependent information....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13255
更新日期:2019-01-01 00:00:00
abstract::Francis Bacon, who with Rene Decartes laid the intellectual foundations for Western science in the seventeenth century, asserted that the purpose of all knowledge is "action in the production of works for ... the relief of man's estate." We assess briefly several aspects of a few of the current efforts directed to the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1555493
更新日期:2003-04-01 00:00:00
abstract::Carlo Fidani Peel Regional Cancer Center at the Credit Valley Site of the Credit Valley Hospital and Trillium Health Center is currently undergoing a redevelopment to build a brachytherapy suite and associated areas with a projected start date of April 2013. The new brachytherapy suite will be located in the PRCC, and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740117
更新日期:2012-07-01 00:00:00
abstract::The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response ne...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1915017
更新日期:2005-06-01 00:00:00
abstract:PURPOSE:Consistency verification between the data from treatment planning system (TPS), record and verification system (R&V), and delivered recorder with visual inspection is time consuming and subject to human error. The purpose of this work is to develop a software tool to automatically perform such verifications. M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735263
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The research is to develop a novel CNN-based adversarial deep learning method to improve and expedite the multi-organ semantic segmentation of CT images and to generate accurate contours on pelvic CT images. METHODS:Planning CT and structure datasets for 120 patients with intact prostate cancer were retrospect...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14580
更新日期:2020-11-05 00:00:00
abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1591431
更新日期:2003-08-01 00:00:00
abstract:PURPOSE:In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* es...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12318
更新日期:2017-07-01 00:00:00
abstract::It is shown that in narrow monoenergetic photon beams under conditions of lateral electron disequilibrium, primary absorbed dose P(r) is a simple function of beam radius r: P(r) = P lambda.(1 - e(-gamma.r)), where P lambda is the primary dose in broad beams for which complete lateral electron equilibrium exists, and g...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596741
更新日期:1991-07-01 00:00:00
abstract::A high sensitivity (HS) model of radiochromic film is receiving increasing use. The film's linear sensitometric response in the range of 0.5-40 Gy would make this film an ideal candidate for complex dosimetry applications that require tissue equivalence. This study investigates the potential use for clinical dosimetry...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1883565
更新日期:2005-04-01 00:00:00
abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905050
更新日期:2015-02-01 00:00:00
abstract::The measurement of the radioactivity administered to the patient is one of the major components of 90Y microsphere liver brachytherapy. The activity of 90Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90Y in the dose calibrator was verified using an activity...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2731034
更新日期:2007-06-01 00:00:00
abstract:PURPOSE:Accurate segmentation of lungs with severe interstitial lung disease (ILD) in thoracic computed tomography (CT) is an important and difficult task in the development of computer-aided diagnosis (CAD) systems. Therefore, we developed in this study a texture analysis-based method for accurate segmentation of lung...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3222872
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4950722
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12459
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:To evaluate the patient positioning accuracy and reproducibility of two commercially available immobilization systems for Stereotactic Body Radiotherapy (SBRT) treatment. METHODS:Forty one patients with lung (n=21) or liver (n=20) malignancies were assigned to one of the two immobilization devices: Elekta ster...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735009
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The aim of this paper was to investigate the relationship between the physical and subjective (observer) image quality metrics in digital chest radiography. METHODS:Five digital radiography systems, four with indirect flat panel detector and one with storage phosphor-based computed radiography system, were use...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14244
更新日期:2020-09-01 00:00:00
abstract::Various techniques have been developed to localize radioactive sources in brachytherapy implants. The most common methods include the orthogonal film method, the stereo-shift film method, and recently, direct localization from a series of contiguous CT transverse images. The major advantage of the CT method is that it...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598548
更新日期:1999-04-01 00:00:00
abstract:PURPOSE:This paper describes the low-kV spectral optimization of dual-energy CT (DECT) equipped with high-kV tin filtration for the quantitative acquisition of electron density information, which is essential for treatment planning in radiotherapy. In addition, an analytical DECT image simulation was preliminarily perf...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3584200
更新日期:2011-06-01 00:00:00
abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598354
更新日期:1998-09-01 00:00:00
abstract:PURPOSE:In dose guided radiation therapy, incident fluence is one of the important parameters for both influence verification and dose reconstruction. The objective of this investigation was to develop a method to obtain the incident fluence for dose reconstruction in dose guided radiation therapy (DGRT). METHODS:An i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735593
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3483784
更新日期:2010-10-01 00:00:00
abstract:PURPOSE:The purpose of this study is to evaluate the feasibility of kilovoltage cone-beam CT (CBCT) images that are obtained with the Varian On-Board Imager in dose calculation at each radiation therapy. METHODS:CBCT images are commonly degraded by scattered radiations originating in the patient's body, and so the CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734936
更新日期:2012-06-01 00:00:00
abstract::We describe the use of a graphical mathematical spreadsheet programming environment which can be used to simulate the acquisition and reconstruction processes of an x-ray computed tomography (CT) machine. The simulation is used to study the effect of photon counting statistics on the noise in the reconstructed image. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598654
更新日期:1999-08-01 00:00:00
abstract::Multi-instrument activity estimation and decay correction techniques were developed for radionuclide mixtures, motivated by the desire for accurate quantitation of Tc-94m positron emission tomography (PET) studies. Tc-94m and byproduct Tc isotopes were produced by proton irradiation of enriched Mo-94 and natural Mo ta...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1333411
更新日期:2001-01-01 00:00:00
abstract:PURPOSE:Respiratory motion in the chest region during single photon emission computed tomography (SPECT) is a major degrading factor that reduces the accuracy of image quantification. This effect is more notable when the tumor is very small, or the spatial resolution of the imaging system is less than the respiratory m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13807
更新日期:2019-11-01 00:00:00