Abstract:
PURPOSE:Normal patient databases (NPDs) are used to distinguish between normal and abnormal perfusion in SPECT myocardial perfusion imaging (MPI) and have gained wide acceptance in the clinical environment, yet there are limitations to this approach. This study introduces a template-based method for semi-quantitative MPI, which attempts to overcome some of the NPD limitations. METHODS:Our approach involves the construction of a 3D digital healthy heart template from the delineation of the patient's left ventricle in the SPECT image. This patient-specific template of the heart, filled with uniform activity, is then analytically projected and reconstructed using the same algorithm as the original image. Subsequent to generating bulls-eye maps for the patient image (PB) and the template image (TB), a ratio (PB/TB) is calculated, which produces a reconstruction-artifact corrected image (CB). Finally, a threshold is used to define defects within CB enabling measurements of the perfusion defect extent (EXT). The SPECT-based template (Ts) measurements were compared to those of a CT-based "ideal" template (TI). Twenty digital phantoms were simulated: male and female, each with one healthy heart and nine hearts with various defects. Four physical phantom studies were performed modeling a healthy heart and three hearts with different defects. The phantom represented a thorax with spine, lung, and left ventricle inserts. Images were acquired on General Electric's (GE) Infinia Hawkeye SPECT/CT camera using standard clinical MPI protocol. Finally, our method was applied to 14 patient MPI rest/stress studies acquired on the GE Infinia Hawkeye SPECT/CT camera and compared to the results obtained from Cedars-Sinai's QPS software. RESULT:In the simulation studies, the true EXT correlated well with the TI (slope= 1.08; offset = -0.40%; r = 0.99) and Ts (slope = 0.90; offset = 0.27%; r = 0.99) methods with no significant differences between them. Similarly, strong correlations were measured for EXT obtained from QPS and the template method for patient studies (slope =0.91; offset = 0.45%; r = 0.98). Mean errors in extent for the Ts method using simulation, physical phantom, and patient data were 2.7% +/- 2.4%, 0.9% +/- 0.5%, 2.0% +/- 2.7%, respectively. CONCLUSIONS:The authors introduced a method for semi-quantitative SPECT MPI, which offers a patient-specific approach to define the perfusion defect regions within the heart, as opposed to the patient-averaged NPD methodology.
journal_name
Med Physjournal_title
Medical physicsauthors
Hughes T,Shcherbinin S,Celler Adoi
10.1118/1.3595112subject
Has Abstractpub_date
2011-07-01 00:00:00pages
4186-95issue
7eissn
0094-2405issn
2473-4209journal_volume
38pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Performance characteristics sufficient to provide physical data base specific to the Siemen's Stabilipan 2 orthovoltage x-ray therapy machine are presented. Operating conditions covering the working range of the unit from 100 to 300 kVp are selected. Beam quality, output, the central axis depth dose, relative output f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596016
更新日期:1987-09-01 00:00:00
abstract::A very important issue in contemporary inverse treatment radiotherapy planning is the specification of proper dose-volume constraints limiting the treatment planning algorithm from delivering high doses to the normal tissue surrounding the tumor. Recently we have proposed a method called reverse mapping of normal tiss...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2198307
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:Dosimetry with ionization chambers in clinical ion beams for radiation therapy requires correction for recombination effects. However, common radiation protocols discriminate between initial and general recombination and provide no universal correction method for the presence of both recombination types in ion ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4962483
更新日期:2016-10-01 00:00:00
abstract:PURPOSE:RapidArc is routinely used for stereotactic radiotherapy for lung cancer. While treatment dose is optimized and calculated on a static CT image, the motion of the target in conjunction with the motion of the MLC may Result in a delivered dose deviating from the planed dose. In this study, we investigate the dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734660
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as inter...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948999
更新日期:2016-06-01 00:00:00
abstract::Studies suggest that clinical outcomes are improved in repeat trigeminal neuralgia (TN) Gamma Knife radiosurgery if a different part of the nerve from the previous radiosurgery is treated. The MR images taken in the first and repeat radiosurgery need to be coregistered to map the first radiosurgery volume onto the sec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1944287
更新日期:2005-07-01 00:00:00
abstract::(Received 22 October 2001; accepted for publication 26 March 2002; published 22 May 2002) With advanced conformal radiotherapy using intensity modulated beams, it is important to have radiation dose verification measurements prior to treatment. Metal oxide semiconductor field effect transistors (MOSFET) have the advan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1481520
更新日期:2002-06-01 00:00:00
abstract:PURPOSE:To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3578602
更新日期:2011-05-01 00:00:00
abstract::Two new liquid ionization chamber (LIC) designs, consisting of cylindrical and plane-parallel configurations, are presented. They are designed to be suitable for high-precision measurements of absorbed dose-to-water at dose rates and photon energies typical for LDR intermediate photon energy brachytherapy sources. The...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598268
更新日期:1998-06-01 00:00:00
abstract::Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 degrees to 40...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2756941
更新日期:2007-08-01 00:00:00
abstract::Measurements of a 670-MeV/amu 20Ne beam at the Lawrence Berkeley Laboratory Bevalac heavy-ion accelerator with various thicknesses of water absorber were obtained with the BERKLET. The BERKLET, a simple three-stage solid-state telescope detector, has been described previously. This instrument measures the linear energ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596536
更新日期:1990-03-01 00:00:00
abstract::A tomographic attachment was designed and developed that attaches to our existing simulator. The film tomograms obtained with the aid of this device exhibit very low geometrical distortion and good contrast and resolution for the objects used in this investigation. In addition, our results to date show that adjacent a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594662
更新日期:1980-03-01 00:00:00
abstract::We designed a questionnaire to be filled out by the physicist at the time of planning treatment with the aid of a computer in order to assess what was learned during the course of the planning session. We analyzed the results to gauge the impact of the 70 treatment planning sessions conducted during the one month peri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596302
更新日期:1988-03-01 00:00:00
abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735351
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To develop an automatic knot placement algorithm to enable the use of NonUniform Rational B-Splines (NURBS) in deformable image registration. METHODS:The authors developed a two-step approach to fit a known displacement vector field (DVF). An initial fit was made with uniform knot spacing. The error generated ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3609416
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:To investigate the accuracy of output factor measurements using a commercial (Exradin W1, SI) and a prototype, "in-house" developed, plastic scintillation dosimeter (PSD) in small photon fields. METHODS:Repetitive detector-specific output factor OFdet measurements were performed in water (parallel to the CAX) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12064
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as(99m)Tc or most positron emission tomography radiopharmaceuticals. METHODS:By evaluation of the resul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4884035
更新日期:2014-07-01 00:00:00
abstract::Stereo x-ray radiography attracts increasing attention in major clinical applications. The purpose of this paper is to analyze the 3D localization error for breast biopsy procedures and provide guidelines for improving its accuracy. Our prototype is a CCD based digital stereo x-ray imaging system. The mathematical mod...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598953
更新日期:2000-05-01 00:00:00
abstract::In this paper, the authors review the field of resolution modeling in positron emission tomography (PET) image reconstruction, also referred to as point-spread-function modeling. The review includes theoretical analysis of the resolution modeling framework as well as an overview of various approaches in the literature...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4800806
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:Color images are visualized on medical monitors that are adjusted by a grayscale standard display function (GSDF) or γ2.2. Although the GSDF is visually displayed as a linear graded grayscale, it does not specify how color medical images should be presented. On the other hand, the usual gamma setting for color ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13532
更新日期:2019-06-01 00:00:00
abstract::A study of the objective imaging characteristics of a new asymmetric screen-film system is presented herein. The system is characterized by high x-ray absorption asymmetric screens, and a low-noise, high-contrast asymmetric film having near-zero crossover. Comparisons are made with the imaging characteristics of two w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597407
更新日期:1994-09-01 00:00:00
abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598306
更新日期:1998-07-01 00:00:00
abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735220
更新日期:2012-06-01 00:00:00
abstract::Depth dose characteristics of 24-MV beams from a medical linear accelerator at various SSDs have been measured. The dose buildup, percent depth dose (PDD), and output were measured using ionization chambers and a diode detector under full scatter. Surface dose ranged from 8% to 51% depending upon the collimator settin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596673
更新日期:1991-03-01 00:00:00
abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1508108
更新日期:2002-10-01 00:00:00
abstract::A formulation of the single energy photon transport problem is cast in the form of a series of convolutions over the primary fluence distribution with invariant kernels. A method is developed for compensating for the variant intervoxel attenuation in the scattered dose distribution by means of an invariant correction ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595964
更新日期:1986-07-01 00:00:00
abstract:PURPOSE:Water equivalent diameter (WED) is the preferred surrogate for patient size in CT. It is better than geometric size surrogates and patient weight/height/BMI/age because it correlates the best with x-ray attenuation. The administration of oral/IV contrast agents increases a patient's attenuation and should there...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14721
更新日期:2021-01-13 00:00:00
abstract::We believe that, for the purpose of evaluation and optimization of treatment plans, quasirandom sampling is superior to grid sampling and should be the method of choice. We believe it to be on average more efficient than grid sampling (i.e., more accurate for any given number of dose estimates) and, even more importan...
journal_title:Medical physics
pub_type: 评论,信件
doi:10.1118/1.597103
更新日期:1993-09-01 00:00:00
abstract::Permanent implantation of 125I (iodine) or 103Pd (palladium) sources is a popular treatment option in the management of early stage prostate cancer. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast impl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3006151
更新日期:2008-12-01 00:00:00
abstract:PURPOSE:To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. METHODS:A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3551999
更新日期:2011-03-01 00:00:00