Improvement of off-axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system.

Abstract:

PURPOSE:Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Freiburg, Germany) (OCT4D) in conjunction with an Octavius 1000SRS array (OCT1000) (PTW, Freiburg, Germany), repositioning the phantom off-axis is required to ensure the measurement area coincides with the tumor. The aim of this work is to quantify delivery errors using an array repositioned off-axis and evaluate new software which incorporates corrections for off-axis phantom measurements. METHODS:Dynamic conformal arcs and 25 lung SABR plans were created with the isocenter at the patient midline and the target volume off-axis. Measurements were acquired with an OCT4D phantom in conjunction with a 729 array (PTW, Freiburg, Germany) (OCT729) placed at isocenter. These plans were recalculated and delivered to both the OCT729 and OCT1000 arrays repositioned so that the high-dose region was at the center of the phantom. Comparisons were made using VeriSoft v7.0 (PTW, Freiburg, Germany) and the newly implemented version 7.1 with 2%/2 mm gamma criterion (10% threshold) and results correlated with off-axis distance to the tumor. RESULTS:Average pass rates for VeriSoft v7.0 significantly reduced from 92.7 ± 2.4% to 84.9 ± 4.1% when the phantom was repositioned compared to the isocenter setup for the OCT729. The gamma pass rates significantly decreased the further the phantom was moved off-axis. Significantly higher pass rates were observed for the OCT1000 of 95.7 ± 3.6% and a significant decrease in gamma pass rate with off-axis phantom distance was again observed. In contrast, even with phantom repositioning, the pass rates for analysis with VeriSoft v7.1 were 93.7 ± 2.1% and 99.4 ± 1.1% for OCT729 and OCT1000, respectively. No significant difference in gamma pass rate was observed with off-axis phantom position irrespective of array type with the new software. CONCLUSION:The errors in QA phantom measurements due to dose reconstruction at off-axis target geometry have been demonstrated for conformal arcs and clinical VMAT SABR plans. A novel software solution implemented by the vendor to allow accurate pass rates has been tested. This solution enables high-resolution arrays with small active detection areas to be used for quality assurance of SABR treatment plans in the off-axis treatment position.

journal_name

Med Phys

journal_title

Medical physics

authors

Jeevanandam P,Agnew CE,Irvine DM,McGarry CK

doi

10.1002/mp.12805

subject

Has Abstract

pub_date

2018-04-01 00:00:00

pages

1738-1747

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • Comparison of CBCT-based dose calculation methods in head and neck cancer radiotherapy: from Hounsfield unit to density calibration curve to deep learning.

    abstract:PURPOSE:Anatomical variations occur during head and neck (H&N) radiotherapy treatment. kV cone-beam computed tomography (CBCT) images can be used for daily dose monitoring to assess dose variations owing to anatomic changes. Deep learning methods (DLMs) have recently been proposed to generate pseudo-CT (pCT) from CBCT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14387

    authors: Barateau A,De Crevoisier R,Largent A,Mylona E,Perichon N,Castelli J,Chajon E,Acosta O,Simon A,Nunes JC,Lafond C

    更新日期:2020-10-01 00:00:00

  • Nonlinear magnetic stereotaxis: three-dimensional, in vivo remote magnetic manipulation of a small object in canine brain.

    abstract::In a series of in vivo experiments on five adult canines, a small cylindrical permanent magnet (approximately 5-mm diameter x 5 mm long) was magnetically moved under fluoroscopic guidance from an occipital-lobe burr hole to a predetermined destination within the brain and then removed. On three of the animals, dorsal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596520

    authors: Grady MS,Howard MA 3rd,Molloy JA,Ritter RC,Quate EG,Gillies GT

    更新日期:1990-05-01 00:00:00

  • A K alpha dual energy x-ray source for coronary angiography.

    abstract::The use of characteristic-line radiation from rare-earth targets bombarded by high-energy (up to 1 MeV) electron beams has been evaluated as an x-ray source for dual energy K-edge subtraction imaging of the human coronary arteries. Two characteristic-line x-ray sources, one using the split K alpha 1 and K alpha 2 line...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596648

    authors: Manning HL,Shefer RE,Klinkowstein RE,Mistretta CA

    更新日期:1991-09-01 00:00:00

  • Automatic detection of simulated motion blur in mammograms.

    abstract:PURPOSE:To use machine-learning algorithms and blur measure (BM) operators to automatically detect motion blur in mammograms. Motion blur has been reported to reduce lesion detection performance and mask small abnormalities, resulting in failure to detect them until they reach more advanced stages. Automatic detection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14069

    authors: Kamona N,Loew M

    更新日期:2020-04-01 00:00:00

  • High resolution 2D dose measurement device based on a few long scintillating fibers and tomographic reconstruction.

    abstract:PURPOSE:Patient-specific QA of highly conformal radiotherapy treatments are usually conducted using 2D or 3D dosimetry of the incident dose distribution in a water-equivalent phantom. However, dosimeters typically used for this task usually lack in either spatial resolution or dose accuracy. The purpose of this work is...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736526

    authors: Goulet M,Archambault L,Beaulieu L,Gingras L

    更新日期:2012-08-01 00:00:00

  • A novel off-axis scanning method for an enlarged ellipse cone-beam computed tomography field of view.

    abstract:PURPOSE:Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3514130

    authors: Li T,Li X,Yang Y,Heron DE,Huq MS

    更新日期:2010-12-01 00:00:00

  • A time-domain wavelet-based approach for fluorescence diffuse optical tomography.

    abstract:PURPOSE:In the context of fluorescence diffuse optical tomography, determining the optimal way to exploit the time-resolved information has been receiving much attention and different features of the time-resolved signals have been introduced. In this article, the authors revisit and generalize the notion of feature, c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431571

    authors: Ducros N,Da Silva A,Dinten JM,Seelamantula CS,Unser M,Peyrin F

    更新日期:2010-06-01 00:00:00

  • MRI-related FDA adverse event reports: A 10-yr review.

    abstract:PURPOSE:To provide an overview of the types of adverse events reported to the US Food and Drug Administration (US FDA) for magnetic resonance (MR) systems over a 10-yr period. METHODS:Two reviewers independently reviewed adverse events reported to FDA for MR systems from 1 January 2008 to 31 December 2017 and manually...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.13768

    authors: Delfino JG,Krainak DM,Flesher SA,Miller DL

    更新日期:2019-12-01 00:00:00

  • X-ray imaging technique for in vitro tissue composition measurements using saline/iodine displacement: technique optimization.

    abstract::An in vitro radiographic technique which uses saline/iodine displacement has been developed to study the thickness of bone-equivalent and soft-tissue-equivalent materials within atherosclerotic plaques in arterial specimens which have been cut open longitudinally and laid flat. Results concerning the optimization of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597916

    authors: Moreau M,Holdsworth DW,Fenster A

    更新日期:1997-01-01 00:00:00

  • SU-E-T-573: Quality and Deliverability of Intensity Modulated Neutron Radiotherapy (IMNRT) Plans.

    abstract:PURPOSE:Intensity Modulated Neutron Radiotherapy (IMNRT) has been commissioned for clinical use. The number of allowable segments in IMNRT plans is limited by MLC speed. Quality and deliverability of static IMNRT treatment plans using the TG-119 test suite were evaluated to establish guidelines for the number of segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735662

    authors: Spink R,Burmeister J,Bossenberger T,Snyder M

    更新日期:2012-06-01 00:00:00

  • Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values.

    abstract:PURPOSE:To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905116

    authors: Ubeda C,Miranda P,Vano E

    更新日期:2015-02-01 00:00:00

  • Detecting electron beam energy shifts with a commercially available energy monitor.

    abstract::Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy dri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599033

    authors: Evans MD,Moftah BA,Olivares M,Podgorsak EB

    更新日期:2000-07-01 00:00:00

  • Intensity modulated arc deliveries approximated by a large number of fixed gantry position sliding window dynamic multileaf collimator fields.

    abstract::The intensity modulated arc has been proposed as an alternative to tomotherapy. Treatment planing systems more typically model the conventional step and shoot or sliding window dynamic multileaf collimator (DMLC) deliveries, and may not support intensity modulated arc therapy (IMAT). As well, another potential drawbac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508110

    authors: MacKenzie MA,Robinson DM

    更新日期:2002-10-01 00:00:00

  • SU-E-T-382: An Analysis of VMAT Monthly Quality Assurance.

    abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735470

    authors: Stenbeck J,Oves S,Gebreamlak W,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • SU-E-I-41: Characterization of a Linear Fiber-Optic Coupled Dosimeter.

    abstract:PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length repres...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734756

    authors: Hoerner M,Hintenlang D

    更新日期:2012-06-01 00:00:00

  • X-ray scatter correction in breast tomosynthesis with a precomputed scatter map library.

    abstract:PURPOSE:To develop and evaluate the impact on lesion conspicuity of a software-based x-ray scatter correction algorithm for digital breast tomosynthesis (DBT) imaging into which a precomputed library of x-ray scatter maps is incorporated. METHODS:A previously developed model of compressed breast shapes undergoing mamm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4866229

    authors: Feng SS,D'Orsi CJ,Newell MS,Seidel RL,Patel B,Sechopoulos I

    更新日期:2014-03-01 00:00:00

  • Monte Carlo modeling of the response of NRC's 90Sr/90Y primary beta standard.

    abstract::The BEAMnrc/EGSnrc Monte Carlo code system is employed to develop a model of the National Research Council of Canada primary standard of absorbed dose to tissue in a beta radiation field, comprising an extrapolation chamber and 90Sr/90Y beta source. We benchmark the model against the measured response of the chamber i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1997347

    authors: Selvam TP,Saull PR,Rogers DW,National Research Council of Canada.

    更新日期:2005-10-01 00:00:00

  • Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources.

    abstract::Underlying characteristics in brachytherapy dosimetry parameters for medical radionuclides 137Cs, 125I, 192Ir, 103Pd, and 169Yb were examined using Monte Carlo methods. Sources were modeled as unencapsulated point or line sources in liquid water to negate variations due to materials and construction. Importance of pha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2199987

    authors: Melhus CS,Rivard MJ

    更新日期:2006-06-01 00:00:00

  • A CdZnTe slot-scanned detector for digital mammography.

    abstract::A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1523932

    authors: Mainprize JG,Ford NL,Yin S,Gordon EE,Hamilton WJ,Tümer TO,Yaffe MJ

    更新日期:2002-12-01 00:00:00

  • Feasibility of a simple method of hybrid collimation for megavoltage grid therapy.

    abstract:PURPOSE:Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4801902

    authors: Almendral P,Mancha PJ,Roberto D

    更新日期:2013-05-01 00:00:00

  • The head-scatter factor for small field sizes.

    abstract::The head-scatter factors H were examined for four different linear accelerators and were found to be similar at field sizes larger than 3 x 3 cm2. Sharply reduced values for small collimator openings were observed for all the accelerators. It is concluded that the head-scatter (or collimator-scatter) factor has two ma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597256

    authors: Zhu TC,Bjärngard BE

    更新日期:1994-01-01 00:00:00

  • Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.

    abstract:PURPOSE:MR thermometry based on the proton resonance frequency shift (PRFS) is the most commonly used method for the monitoring of thermal therapies. As the chemical shift of water protons is temperature dependent, the local temperature variation (relative to an initial baseline) may be calculated from time-dependent p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3309439

    authors: Viallon M,Terraz S,Roland J,Dumont E,Becker CD,Salomir R

    更新日期:2010-04-01 00:00:00

  • Application of the TRS 483 code of practice for reference and relative dosimetry in tomotherapy.

    abstract:PURPOSE:To apply the recent code of practice from the IAEA/AAPM, TRS 483, to helical tomotherapy (HT) for reference and relative dosimetry obtaining correction factors for the Exradin A1SL ionization chamber. METHODS:The beam quality correction factor for the A1SL chamber was obtained through three different approache...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13855

    authors: Lopes MDC,Santos T,Ventura T,Capela M

    更新日期:2019-12-01 00:00:00

  • Oxygen distribution in tumors: a qualitative analysis and modeling study providing a novel Monte Carlo approach.

    abstract:PURPOSE:To construct a Monte Carlo (MC)-based simulation model for analyzing the dependence of tumor oxygen distribution on different variables related to tumor vasculature [blood velocity, vessel-to-vessel proximity (vessel proximity), and inflowing oxygen partial pressure (pO2)]. METHODS:A voxel-based tissue model c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892386

    authors: Lagerlöf JH,Kindblom J,Bernhardt P

    更新日期:2014-09-01 00:00:00

  • Skeletal dosimetry for external exposures to photons based on microCT images of spongiosa: consideration of voxel resolution, cluster size, and medullary bone surfaces.

    abstract::Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skele...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3242266

    authors: Kramer R,Khoury HJ,Vieira JW,Robson Brown KA

    更新日期:2009-11-01 00:00:00

  • Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

    abstract::The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric effects were studied considering the breathing pattern of three patients monitored during the course of their treatment ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2821704

    authors: Seco J,Sharp GC,Wu Z,Gierga D,Buettner F,Paganetti H

    更新日期:2008-01-01 00:00:00

  • Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs.

    abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3641874

    authors: Audet C,Poffenbarger BA,Chang P,Jackson PS,Lundahl RE,Ryu SI,Ray GR

    更新日期:2011-11-01 00:00:00

  • An anthropomorphic torso section phantom for ultrasonic imaging.

    abstract::Using stable materials capable of mimicking any soft tissues of the human body--quantitatively with respect to speed of sound, density, and attenuation coefficient and semiquantitatively with respect to scatter--we have constructed a torso section phantom containing simulated bowel gas, kidney, kidney fat pad, liver, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594657

    authors: Madsen EL,Zagzebski JA,Ghilardi-Netto T

    更新日期:1980-01-01 00:00:00

  • Characteristics of sensitometric curves of radiographic films.

    abstract::A new type of radiographic film, EDR (extended dose range) film, has been recently become available for film dosimetry. It is particularly attractive for composite isodose verification of intensity modulated radiation therapy because of its low sensitivity relative to the more common Kodak XV film. For XV film, the re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1568979

    authors: Zhu XR,Yoo S,Jursinic PA,Grimm DF,Lopez F,Rownd JJ,Gillin MT

    更新日期:2003-05-01 00:00:00

  • Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.

    abstract::The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous sil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2147744

    authors: Wendling M,Louwe RJ,McDermott LN,Sonke JJ,van Herk M,Mijnheer BJ

    更新日期:2006-02-01 00:00:00