Detecting electron beam energy shifts with a commercially available energy monitor.

Abstract:

:Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy drifts has been evaluated. The device shows an 11% change in signal for a 2 mm change in the I50 energy parameter for low energy electron beams (in the vicinity of 6 MeV) and a 2.5% change in signal for a 2 mm change in the I50 energy parameter for high energy electron beams (in the vicinity of 22 MeV). Thus the device is capable of detecting small energy shifts resulting from bending magnet drift for all clinically relevant electron beams.

journal_name

Med Phys

journal_title

Medical physics

authors

Evans MD,Moftah BA,Olivares M,Podgorsak EB

doi

10.1118/1.599033

subject

Has Abstract

pub_date

2000-07-01 00:00:00

pages

1661-3

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

27

pub_type

杂志文章
  • Fast internal marker tracking algorithm for onboard MV and kV imaging systems.

    abstract::Intrafraction organ motion can limit the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT) due to target position uncertainty. To ensure high accuracy in beam targeting, real-time knowledge of the target location is highly desired throughout the beam delivery process. T...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2905225

    authors: Mao W,Wiersma RD,Xing L

    更新日期:2008-05-01 00:00:00

  • Dose distributions in bifurcated coronary vessels treated with catheter-based photon and beta emitters in intravascular brachytherapy.

    abstract::The dose distributions in the bifurcated vessels treated with intravascular brachytherapyline sources are complicated and depend on the bifurcation geometry consisting of a main and a branch vessel at different angles. To investigate the dosimetric effects at the bifurcation, calculations were performed on branching v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1582813

    authors: Yue N,Roberts KB,Pfau SE,Nath R

    更新日期:2003-07-01 00:00:00

  • Technical Note: Comparison of megavoltage, dual-energy, and single-energy CT-based μ-maps for a four-channel breast coil in PET/MRI.

    abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12407

    authors: Patrick JC,Terry Thompson R,So A,Butler J,Faul D,Stodilka RZ,Yartsev S,Prato FS,Gaede S

    更新日期:2017-09-01 00:00:00

  • X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain.

    abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513157

    authors: Hunt DC,Kirby SS,Rowlands JA

    更新日期:2002-11-01 00:00:00

  • Monte Carlo simulations on the water-to-air stopping power ratio for carbon ion dosimetry.

    abstract::Many papers discussed the I value for water given by the ICRU, concluding that a value of about 80 +/- 2 eV instead of 67.2 eV would reproduce measured ion depth-dose curves. A change in the I value for water would have an effect on the stopping power and, hence, on the water-to-air stopping power ratio, which is impo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3085877

    authors: Henkner K,Bassler N,Sobolevsky N,Jäkel O

    更新日期:2009-04-01 00:00:00

  • A delivery quality assurance tool based on the actual leaf open times in tomotherapy.

    abstract:PURPOSE:To validate a delivery quality assurance (DQA) protocol for tomotherapy based on the measurement of the leaf open times (LOTs). In addition, to show the correlation between the mean relative LOT discrepancy and the dose deviation in the planning target volume (PTV). MATERIALS AND METHODS:We used a LOT measurem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14348

    authors: Schopfer M,Bochud FO,Bourhis J,Moeckli R

    更新日期:2020-09-01 00:00:00

  • SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators.

    abstract:PURPOSE:Quantitative SPECT imaging is limited by many factors, including penetration of high energy photons through the collimator. Even small peaks of high energy yield extensive contamination in the photopeak energy window. Rotating slat collimators typically offer a 40- to 50-fold increase in geometric detection eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3177312

    authors: Van Holen R,Staelens S,Vandenberghe S

    更新日期:2009-09-01 00:00:00

  • Detection nonuniformity measurements and corrections for cone beam transmission CT on a gamma camera.

    abstract::Cone beam transmission CT (CB-CT) improves SPECT imaging by providing high-quality attenuation maps for attenuation compensation and for correlated SPECT and CT imaging. The present work measures the detection nonuniformity for CB-CT implemented with a gamma camera, and applies nonuniformity corrections to make CB-CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596838

    authors: Manglos SH,Capone RB,Bassano DA

    更新日期:1992-03-01 00:00:00

  • Efficient generation of a magnetic field-free line.

    abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3447726

    authors: Knopp T,Erbe M,Biederer S,Sattel TF,Buzug TM

    更新日期:2010-07-01 00:00:00

  • Low-dose CT reconstruction using spatially encoded nonlocal penalty.

    abstract:PURPOSE:Computed tomography (CT) is one of the most used imaging modalities for imaging both symptomatic and asymptomatic patients. However, because of the high demand for lower radiation dose during CT scans, the reconstructed image can suffer from noise and artifacts due to the trade-off between the image quality and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12523

    authors: Kim K,El Fakhri G,Li Q

    更新日期:2017-10-01 00:00:00

  • SU-E-T-159: Sensitivity of in Line Real Time Scintillating Fiber Detectors for External Beam Treatment Verification and Patient Safety.

    abstract:PURPOSE:We studied the sensitivity of a novel transmission fiber scintillator array designed and built for in line treatment verification. The purpose of this project is to assess the capability of the fiber detector array technology to detect treatment errors in real time without false positives to enhance patient saf...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735217

    authors: Izaguirre EW,Price SG,Smajlovic S,Yaddanapudi S,Wooten H,Mutic S

    更新日期:2012-06-01 00:00:00

  • Measurement of surface dose in an MR-Linac with optically stimulated luminescence dosimeters for IMRT beam geometries.

    abstract:PURPOSE:This study aims to measure the surface dose on an anthropomorphic phantom for intensity-modulated radiation therapy (IMRT) plans treated in a 1.5 T magnetic resonance (MR)-Linac. Previous studies have used Monte Carlo programs to simulate surface dose and have recognized high surface dose as a potential limitin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14185

    authors: Lim-Reinders S,Keller BM,Sahgal A,Chugh B,Kim A

    更新日期:2020-07-01 00:00:00

  • Age-dependent dose calculations for common PET radionuclides and brain radiotracers in nonhuman primate computational models.

    abstract:PURPOSE:The combination of nonhuman primates (NHPs) with the state-of-the-art molecular imaging technologies allows for within-subject longitudinal research aiming at gaining new insights into human normal and disease conditions and provides an ideal foundation for future translational studies of new diagnostic tools, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14333

    authors: Xie T,Chen X,Zaidi H

    更新日期:2020-09-01 00:00:00

  • Theoretical investigation of the count rate capabilities of in-pixel amplifiers for photon counting arrays based on polycrystalline silicon TFTs.

    abstract:PURPOSE:Photon counting arrays (PCAs), capable of measuring the spectral information of individual x-ray photons and recording that information digitally, provide a number of advantages compared to conventional, energy-integrating active matrix flat-panel imagers - such as reducing the undesirable effects of electronic...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13128

    authors: Liang AK,Koniczek M,Antonuk LE,El-Mohri Y,Zhao Q

    更新日期:2018-10-01 00:00:00

  • Robust optimization in IMPT using quadratic objective functions to account for the minimum MU constraint.

    abstract:PURPOSE:Currently, in clinical practice of intensity-modulated proton therapy (IMPT), the influence of the minimum monitor unit (MU) constraint is taken into account through postprocessing after the optimization is completed. This may degrade the plan quality and plan robustness. This study aims to mitigate the impact ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12677

    authors: Shan J,An Y,Bues M,Schild SE,Liu W

    更新日期:2018-01-01 00:00:00

  • Optimal shielding design for bunkers of compact cyclotrons used in the production of medical radionuclides.

    abstract:PURPOSE:There are several options to consider in the design of a vault that will house a cyclotron for radioisotopes production with regards to the door entrance. Alternatives are a direct-shielded door, a simple maze, or a double-legged maze. In this work, the impact of the neutron and photon doses at the vault entran...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3515458

    authors: Facure A,França WF

    更新日期:2010-12-01 00:00:00

  • Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee.

    abstract::A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT ima...

    journal_title:Medical physics

    pub_type: 指南,杂志文章

    doi:10.1118/1.597605

    authors: Graham LS,Fahey FH,Madsen MT,van Aswegen A,Yester MV

    更新日期:1995-04-01 00:00:00

  • Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device.

    abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4933200

    authors: Zarghami N,Jensen MD,Talluri S,Foster PJ,Chambers AF,Dick FA,Wong E

    更新日期:2015-11-01 00:00:00

  • SU-E-T-398: Verification of Gamma Knife EXtend System Based Fractionated Treatment Planning Using EBT2 Film.

    abstract:PURPOSE:To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS:A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735487

    authors: Gopishankar N,Bisht RK

    更新日期:2012-06-01 00:00:00

  • Geometric studies on variable radius spiral cone-beam scanning.

    abstract::The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and un...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1751251

    authors: Yea Y,Zhu J,Wang G

    更新日期:2004-06-01 00:00:00

  • SU-E-I-99: An Ultra-High Resolution Small Field-Of-View Solid State X-Ray Imaging Detector Based on an Electron Multiplying CCD.

    abstract:PURPOSE:To demonstrate the ultra-high resolution capability of a small field-of-view (FOV) solid state x-ray imaging detector based on an EMCCD sensor. METHODS:A micro-solid state x-ray image intensifier (micro-SSXII) was developed to serve as an ultra-high resolution region-of-interest (ROI) imaging detector. It is b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734816

    authors: Singh V,Loughran B,Jain A,Sharma P,Bednarek D,Rudin S

    更新日期:2012-06-01 00:00:00

  • Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations.

    abstract::Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S val...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3103401

    authors: Pacilio M,Lanconelli N,Lo MS,Betti M,Montani L,Torres AL,Coca PM

    更新日期:2009-05-01 00:00:00

  • A consistent set of neutron kerma coefficients from thermal to 150 MeV for biologically important materials.

    abstract::Neutron cross sections for nonelastic and elastic reactions on a range of elements have been evaluated for incident energies up to 150 MeV. These cross sections agree well with experimental cross section data for charged-particle production as well as neutron and photon production. Therefore they can be used to determ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598601

    authors: Chadwick MB,Barschall HH,Caswell RS,DeLuca PM,Hale GM,Jones DT,MacFarlane RE,Meulders JP,Schuhmacher H,Schrewe UJ,Wambersie A,Young PG

    更新日期:1999-06-01 00:00:00

  • Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.

    abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597328

    authors: Das IJ,Harrington JC,Akber SF,Tomer AF,Murray JC,Cheng CW

    更新日期:1994-06-01 00:00:00

  • On the new metrics for IMRT QA verification.

    abstract:PURPOSE:The aim of this work is to search for new metrics that could give more reliable acceptance/rejection criteria on the IMRT verification process and to offer solutions to the discrepancies found among different conventional metrics. Therefore, besides conventional metrics, new ones are proposed and evaluated with...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964796

    authors: Garcia-Romero A,Hernandez-Vitoria A,Millan-Cebrian E,Alba-Escorihuela V,Serrano-Zabaleta S,Ortega-Pardina P

    更新日期:2016-11-01 00:00:00

  • Low dose positron emission tomography emulation from decimated high statistics: A clinical validation study.

    abstract:PURPOSE:The fundamental nature of positron emission tomography (PET), as an event detection system, provides some flexibility for data handling, including retrospective data manipulation. The reorganization of acquisition data allows the emulation of new scans arising from identical radiotracer spatial distributions, b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13517

    authors: Schaefferkoetter J,Nai YH,Reilhac A,Townsend DW,Eriksson L,Conti M

    更新日期:2019-06-01 00:00:00

  • Determining Pion, the correction factor for recombination losses in an ionization chamber.

    abstract::The 1983 AAPM protocol for the determination of absorbed dose from high-energy photon and electron beams recommends using Pion (the reciprocal of collection efficiency), as determined by the two-voltage technique, to correct for recombination losses in ionization chambers. Methods and data for the determination of ion...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595574

    authors: Weinhous MS,Meli JA

    更新日期:1984-11-01 00:00:00

  • Validation of deformable registration in head and neck cancer using analysis of variance.

    abstract:PURPOSE:Deformable image registration (DIR) is often validated based on a distance-to-agreement (DTA) criterion of automatically propagated anatomical landmarks that were manually identified. Due to human observer variability, however, the performance of the registration method is diluted. The purpose of this study was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4760990

    authors: Mencarelli A,van Beek S,van Kranen S,Rasch C,van Herk M,Sonke JJ

    更新日期:2012-11-01 00:00:00

  • Measurement of energy dependence for XRCT radiochromic film.

    abstract::Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8 +/- 0.35 at 25.5 keV (50 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2219330

    authors: Butson MJ,Cheung T,Yu PK

    更新日期:2006-08-01 00:00:00

  • Material elemental decomposition in dual and multi-energy CT via a sparsity-dictionary approach for proton stopping power ratio calculation.

    abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12796

    authors: Shen C,Li B,Chen L,Yang M,Lou Y,Jia X

    更新日期:2018-04-01 00:00:00