X-ray scatter correction in breast tomosynthesis with a precomputed scatter map library.

Abstract:

PURPOSE:To develop and evaluate the impact on lesion conspicuity of a software-based x-ray scatter correction algorithm for digital breast tomosynthesis (DBT) imaging into which a precomputed library of x-ray scatter maps is incorporated. METHODS:A previously developed model of compressed breast shapes undergoing mammography based on principal component analysis (PCA) was used to assemble 540 simulated breast volumes, of different shapes and sizes, undergoing DBT. A Monte Carlo (MC) simulation was used to generate the cranio-caudal (CC) view DBT x-ray scatter maps of these volumes, which were then assembled into a library. This library was incorporated into a previously developed software-based x-ray scatter correction, and the performance of this improved algorithm was evaluated with an observer study of 40 patient cases previously classified as BI-RADS® 4 or 5, evenly divided between mass and microcalcification cases. Observers were presented with both the original images and the scatter corrected (SC) images side by side and asked to indicate their preference, on a scale from -5 to +5, in terms of lesion conspicuity and quality of diagnostic features. Scores were normalized such that a negative score indicates a preference for the original images, and a positive score indicates a preference for the SC images. RESULTS:The scatter map library removes the time-intensive MC simulation from the application of the scatter correction algorithm. While only one in four observers preferred the SC DBT images as a whole (combined mean score = 0.169 ± 0.37, p > 0.39), all observers exhibited a preference for the SC images when the lesion examined was a mass (1.06 ± 0.45, p < 0.0001). When the lesion examined consisted of microcalcification clusters, the observers exhibited a preference for the uncorrected images (-0.725 ± 0.51, p < 0.009). CONCLUSIONS:The incorporation of the x-ray scatter map library into the scatter correction algorithm improves the efficiency of the algorithm. The observer study presented here is also the first test of the scatter correction algorithm with patient images and human observers, and demonstrates its potential to improve the clinical performance of DBT.

journal_name

Med Phys

journal_title

Medical physics

authors

Feng SS,D'Orsi CJ,Newell MS,Seidel RL,Patel B,Sechopoulos I

doi

10.1118/1.4866229

subject

Has Abstract

pub_date

2014-03-01 00:00:00

pages

031912

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

41

pub_type

杂志文章
  • First clinical implementation of real-time, real anatomy tracking and radiation beam control.

    abstract:PURPOSE:We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. METHODS:The system utilizes real-time cine imaging ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13002

    authors: Green OL,Rankine LJ,Cai B,Curcuru A,Kashani R,Rodriguez V,Li HH,Parikh PJ,Robinson CG,Olsen JR,Mutic S,Goddu SM,Santanam L

    更新日期:2018-05-28 00:00:00

  • A Monte Carlo investigation of low-Z target image quality generated in a linear accelerator using Varian's VirtuaLinac.

    abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4861818

    authors: Parsons D,Robar JL,Sawkey D

    更新日期:2014-02-01 00:00:00

  • Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging.

    abstract:PURPOSE:The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4916802

    authors: Yu L,Vrieze TJ,Leng S,Fletcher JG,McCollough CH

    更新日期:2015-05-01 00:00:00

  • The effects of target size and tissue density on the minimum margin required for random errors.

    abstract::The minimum margins required to compensate for random geometric uncertainties in the delivery of radiotherapy treatment were determined for a spherical Clinical Target Volume, using an analytic model for the cumulative dose. Margins were calculated such that the minimum dose in the target would be no less than 95% of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1809991

    authors: Witte MG,van der Geer J,Schneider C,Lebesque JV,van Herk M

    更新日期:2004-11-01 00:00:00

  • Investigation of effective decision criteria for multiobjective optimization in IMRT.

    abstract:PURPOSE:To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS:A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589128

    authors: Holdsworth C,Stewart RD,Kim M,Liao J,Phillips MH

    更新日期:2011-06-01 00:00:00

  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams.

    abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598293

    authors: Pasma KL,Heijmen BJ,Kroonwijk M,Visser AG

    更新日期:1998-06-01 00:00:00

  • State-of-the-art in two-dimensional ultrasonic transducer array technology.

    abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594247

    authors: Maginness MG,Plummer JD,Beaver WL,Meindl JD

    更新日期:1976-09-01 00:00:00

  • Accurate assessment and prediction of noise in clinical CT images.

    abstract:PURPOSE:The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. METHODS:The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938588

    authors: Tian X,Samei E

    更新日期:2016-01-01 00:00:00

  • A field-shaping multi-well avalanche detector for direct conversion amorphous selenium.

    abstract:PURPOSE:A practical detector structure is proposed to achieve stable avalanche multiplication gain in direct-conversion amorphous selenium radiation detectors. METHODS:The detector structure is referred to as a field-shaping multi-well avalanche detector. Stable avalanche multiplication gain is achieved by eliminating...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4769110

    authors: Goldan AH,Zhao W

    更新日期:2013-01-01 00:00:00

  • Technical note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks.

    abstract:PURPOSE:Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589131

    authors: Fayad H,Pan T,Clement JF,Visvikis D

    更新日期:2011-06-01 00:00:00

  • Scattered photons produced by beam-modifying filters.

    abstract::When a beam-modifying filter such as a wedge or a compensator is placed in an x-ray beam, scattered photons are generated in the filter material. The magnitude of the dose contribution from these photons for a 4-MV x-ray beam was measured. At a distance of 30 cm from the filter, a copper sheet of 1-cm thickness produc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595923

    authors: Huang PH,Chin LM,Bjärngard BE

    更新日期:1986-01-01 00:00:00

  • Accuracy evaluation of a six-degree-of-freedom couch using cone beam CT and IsoCal phantom with an in-house algorithm.

    abstract:PURPOSE:The accuracy of a six degree of freedom (6DoF) couch was evaluated using a novel method. METHODS:Cone beam CT (CBCT) images of a 3D phantom (IsoCal) were acquired with different, known combinations of couch pitch and roll angles. Pitch and roll angles between the maximum allowable values of 357 and 3 degrees w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12342

    authors: Zhang Q,Driewer J,Wang S,Li S,Zhu X,Zheng D,Cao Y,Zhang J,Jamshidi A,Cox BW,Knisely JPS,Potters L,Klein EE

    更新日期:2017-08-01 00:00:00

  • Technical Note: Mobile accelerator guidance using an optical tracker during docking in IOERT procedures.

    abstract:PURPOSE:Intraoperative electron radiation therapy (IOERT) involves the delivery of a high radiation dose during tumor resection in a shorter time than other radiation techniques, thus improving local control of tumors. However, a linear accelerator device is needed to produce the beam safely. Mobile linear accelerators...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12482

    authors: Marinetto E,Victores JG,García-Sevilla M,Muñoz M,Calvo FÁ,Balaguer C,Desco M,Pascau J

    更新日期:2017-10-01 00:00:00

  • Modification of the University of Washington Neutron Radiotherapy Facility for optimization of neutron capture enhanced fast-neutron therapy.

    abstract::A modified neutron production target assembly has been developed to provide improved performance of the proton-cyclotron-based neutron radiotherapy facility at the University of Washington for applications involving neutron capture enhanced fast-neutron therapy. The new target produces a neutron beam that yields essen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598839

    authors: Nigg DW,Wemple CA,Risler R,Hartwell JK,Harker YD,Laramore GE

    更新日期:2000-02-01 00:00:00

  • A boundary element approach for image-guided near-infrared absorption and scatter estimation.

    abstract::Multimodality NIR spectroscopy systems offer the possibility of region-based vascular and molecular characterization of tissue in vivo. However, computationally efficient 3D image reconstruction algorithms specific to these image-guided systems currently do not exist. Image reconstruction is often based on finite-elem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2795832

    authors: Srinivasan S,Pogue BW,Carpenter C,Yalavarthy PK,Paulsen K

    更新日期:2007-11-01 00:00:00

  • Discrimination analysis of breast calcifications using x-ray dark-field radiography.

    abstract:BACKGROUND:X-ray dark-field radiography could enhance mammography by providing more information on imaged tissue and microcalcifications. The dark field signal is a measure of small angle scattering and can thus provide additional information on the imaged materials. This information can be useful for material distinct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14043

    authors: Rauch T,Rieger J,Pelzer G,Horn F,Erber R,Wunderle M,Emons J,Nabieva N,Fuhrich N,Michel T,Hartmann A,Fasching PA,Anton G

    更新日期:2020-04-01 00:00:00

  • Computerized analysis of radiographic bone patterns: effect of imaging conditions on performance.

    abstract::We are developing computerized methods for characterizing the bone texture pattern from digitized skeletal radiographs. For this method to be useful clinically, it must be able to distinguish between weak and strong bone under the range of exposure conditions potentially encountered in the clinical setting. In this st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598858

    authors: Chinander MR,Giger ML,Martell JM,Favus MJ

    更新日期:2000-01-01 00:00:00

  • Predicting high-intensity focused ultrasound thalamotomy lesions using 2D magnetic resonance thermometry and 3D Gaussian modeling.

    abstract:PURPOSE:To develop a method of using two-dimensional (2D) magnetic resonance thermometry, and three-dimensional (3D) Gaussian modeling to predict the volume, shape, and location of 1 day postoperative T1w high-intensity focused ultrasound lesions in medication refractory tremor patients; thereby facilitating a better c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13868

    authors: Seasons GM,Mazerolle EL,Sankar T,Martino D,Kiss ZHT,Pichardo S,Pike GB

    更新日期:2019-12-01 00:00:00

  • Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs.

    abstract:PURPOSE:An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geome...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4826159

    authors: Nelson G,Yoon S,Krishna G,Wilfley B,Fahrig R

    更新日期:2013-11-01 00:00:00

  • MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility.

    abstract::Preclinical experiments are carried out with approximately 20-30 microm wide, approximately 10 mm high parallel microbeams of hard, broad-"white"-spectrum x rays (approximately 50-600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1562169

    authors: Bräuer-Krisch E,Bravin A,Lerch M,Rosenfeld A,Stepanek J,Di Michiel M,Laissue JA

    更新日期:2003-04-01 00:00:00

  • Displacement and strain estimation for evaluation of arterial wall stiffness using a familial hypercholesterolemia swine model of atherosclerosis.

    abstract:PURPOSE:To track variations in the deformation of the arterial wall noninvasively by estimating the accumulated displacement and strain over a cardiac cycle may provide useful indicators of vascular health. METHODS:In this paper, we propose an approach to track a region of interest (ROI) locally and estimate arterial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722746

    authors: Ge W,Krueger CG,Weichmann A,Shanmuganayagam D,Varghese T

    更新日期:2012-07-01 00:00:00

  • Monte Carlo calculation of output factors for circular, rectangular, and square fields of electron accelerators (6-20 MeV).

    abstract::Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1373402

    authors: Verhaegen F,Mubata C,Pettingell J,Bidmead AM,Rosenberg I,Mockridge D,Nahum AE

    更新日期:2001-06-01 00:00:00

  • Optimization of MR pulse sequences for Bayesian image segmentation.

    abstract::A method for optimizing MR imaging pulse sequence parameters in a statistical framework is presented. Parameters are defined to be optimal when the resulting scalar images yield optimal image segmentations using Bayesian pixel classification. Thus, Bayes risk is used as the objective function to minimize. Approximatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597425

    authors: Prince JL,Pham D,Tan O

    更新日期:1995-10-01 00:00:00

  • A statistical approach to infer the minimum setup distance of a well chamber to the wall or to the floor for 192Ir HDR calibration.

    abstract::We propose a new method based on statistical analysis technique to determine the minimum setup distance of a well chamber used in the calibration of 192Ir high dose rate (HDR). The chamber should be placed at least this distance away from any wall or from the floor in order to mitigate the effect of scatter. Three dif...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2911156

    authors: Chang L,Ho SY,Chui CS,Lee JH,Du YC,Chen T

    更新日期:2008-06-01 00:00:00

  • MO-C-BRCD-03: The Role of Informatics in Medical Physics and Vice Versa.

    abstract::Like Medical Physics, Imaging Informatics encompasses concepts touching every aspect of the imaging chain from image creation, acquisition, management and archival, to image processing, analysis, display and interpretation. The two disciplines are in fact quite complementary, with similar goals to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735777

    authors: Andriole K

    更新日期:2012-06-01 00:00:00

  • Optimizing cone beam CT scatter estimation in egs_cbct for a clinical and virtual chest phantom.

    abstract:PURPOSE:Cone beam computed tomography (CBCT) image quality suffers from contamination from scattered photons in the projection images. Monte Carlo simulations are a powerful tool to investigate the properties of scattered photons.egs_cbct, a recent EGSnrc user code, provides the ability of performing fast scatter calcu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881142

    authors: Thing RS,Mainegra-Hing E

    更新日期:2014-07-01 00:00:00

  • Evaluation of the accuracy of fetal dose estimates using TG-36 data.

    abstract::The American Association of Physicists in Medicine Radiation Therapy Committee Task Group 36 report (TG-36) provides guidelines for managing radiation therapy of pregnant patients. Included in the report are data that can be used to estimate the dose to the fetus. The purpose of this study is to evaluate the accuracy ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710332

    authors: Kry SF,Starkschall G,Antolak JA,Salehpour M

    更新日期:2007-04-01 00:00:00

  • Quantitative classification of breast tumors in digitized mammograms.

    abstract::The goal of this study was to develop a technique to distinguish benign and malignant breast lesions in secondarily digitized mammograms. A set of 51 mammograms (two views/patient) containing lesions of known pathology were evaluated using six different morphological descriptors: circularity, mu R/sigma R (where mu R ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597707

    authors: Pohlman S,Powell KA,Obuchowski NA,Chilcote WA,Grundfest-Broniatowski S

    更新日期:1996-08-01 00:00:00

  • Measurement of energy dependence for XRCT radiochromic film.

    abstract::Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8 +/- 0.35 at 25.5 keV (50 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2219330

    authors: Butson MJ,Cheung T,Yu PK

    更新日期:2006-08-01 00:00:00