Predicting high-intensity focused ultrasound thalamotomy lesions using 2D magnetic resonance thermometry and 3D Gaussian modeling.

Abstract:

PURPOSE:To develop a method of using two-dimensional (2D) magnetic resonance thermometry, and three-dimensional (3D) Gaussian modeling to predict the volume, shape, and location of 1 day postoperative T1w high-intensity focused ultrasound lesions in medication refractory tremor patients; thereby facilitating a better comprehension of thermal damage thresholds, which can be utilized to reduce adverse events, and improve patient outcome. METHODS:Fifteen patients underwent magnetic resonance-guided focused ultrasound (MRgFUS) thalamotomy, which was performed at our center using an InSightec ExAblate 4000 system (Haifa, Israel), and guided by magnetic resonance imaging using a 3 T Discovery 750 (General Electric Healthcare, Waukesha, WI, USA). For treatment monitoring, 2D MR thermometry (temperature sensitivity: -0.00909 ppm/°C, bandwidth: 279 Hz/pixel) was performed in multiple orthogonal planes (sagittal, coronal, and axial) intraoperatively. These images were temporally filtered using a general linear model approach to reduce noise. Temporal volumes of filtered temperature maps with a peak temperature ≥ 47°C were aligned and fitted with a 3D Gaussian to create a canonical heating model. We then fitted the filtered 2D temperature maps with a 3D Gaussian, and used the relationships derived from the 3D heating model to estimate the 3D temperature distribution. These temperature distributions were converted into thermal dose distributions and accumulated across time to create an accumulated thermal dose (ATD) profile. Thresholded ATD profiles were then correlated with manually traced T1-weighted 1 day postoperative lesion volumes across patients, and linear regression slopes were plotted against varying ATD thresholds. Additionally, the Dice-Sørensen coefficient (DSC) was calculated to quantify the volumetric overlap between predicted, and actual lesions. RESULTS:On average, 18.1 (standard deviation (SD): ±4.6, range: 10-29) sonications were performed with an average peak temperature achieved of 62.4°C (SD: ±2.4, range: 58.2-67.7). An ATD threshold of 35.8 CEM43 was found to give a unity linear regression slope; this corresponded to an average DSC of 0.689 (SD: ±0.090, range: 0.476-0.815). CONCLUSIONS:Using multiplanar 2D MR thermometry and 3D Gaussian modeling, we were able to achieve very good (DSC = 0.689) predictions of T1w 1 day postoperative lesion volume, shape and location at an ATD threshold of approximately 36 CEM43. Furthermore, this method has the potential to be used in clinical evaluations to further elucidate the relationship between thermal damage and clinical outcome. Accurate 3D lesion prediction will facilitate improved clinical decision making in future MRgFUS thalamotomies.

journal_name

Med Phys

journal_title

Medical physics

authors

Seasons GM,Mazerolle EL,Sankar T,Martino D,Kiss ZHT,Pichardo S,Pike GB

doi

10.1002/mp.13868

subject

Has Abstract

pub_date

2019-12-01 00:00:00

pages

5722-5732

issue

12

eissn

0094-2405

issn

2473-4209

journal_volume

46

pub_type

杂志文章
  • A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT.

    abstract:PURPOSE:On-board MRI can provide superb soft tissue contrast for improving liver SBRT localization. However, the availability of on-board MRI in clinics is extremely limited. On the contrary, on-board kV imaging systems are widely available on radiotherapy machines, but its capability to localize tumors in soft tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12998

    authors: Harris W,Wang C,Yin FF,Cai J,Ren L

    更新日期:2018-07-01 00:00:00

  • Use of simulated annealing for optimization of alignment parameters in limited MRI acquisition volumes of the brain.

    abstract::Studies suggest that clinical outcomes are improved in repeat trigeminal neuralgia (TN) Gamma Knife radiosurgery if a different part of the nerve from the previous radiosurgery is treated. The MR images taken in the first and repeat radiosurgery need to be coregistered to map the first radiosurgery volume onto the sec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1944287

    authors: Li X,Zhang P,Brisman R,Kutcher G

    更新日期:2005-07-01 00:00:00

  • A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration.

    abstract:PURPOSE:In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. How...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3697524

    authors: Hub M,Thieke C,Kessler ML,Karger CP

    更新日期:2012-04-01 00:00:00

  • Design, development, and implementation of the radiological physics center's pelvis and thorax anthropomorphic quality assurance phantoms.

    abstract::The Radiological Physics Center (RPC) developed two heterogeneous anthropomorphic quality assurance phantoms for use in verifying the accuracy of radiation delivery: one for intensity-modulated radiation therapy (IMRT) to the pelvis and the other for stereotactic body radiation therapy (SBRT) to the thorax. The purpos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2737158

    authors: Followill DS,Evans DR,Cherry C,Molineu A,Fisher G,Hanson WF,Ibbott GS

    更新日期:2007-06-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning.

    abstract::The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its p...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2795842

    authors: Chetty IJ,Curran B,Cygler JE,DeMarco JJ,Ezzell G,Faddegon BA,Kawrakow I,Keall PJ,Liu H,Ma CM,Rogers DW,Seuntjens J,Sheikh-Bagheri D,Siebers JV

    更新日期:2007-12-01 00:00:00

  • Polarized x-ray excitation for scatter reduction in x-ray fluorescence computed tomography.

    abstract:PURPOSE:X-ray fluorescence computer tomography (XFCT) is a new molecular imaging modality which uses x-ray excitation to stimulate the emission of fluorescent photons in high atomic number contrast agents. Scatter contamination is one of the main challenges in XFCT imaging which limits the molecular sensitivity. When p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12997

    authors: Vernekohl D,Tzoumas S,Zhao W,Xing L

    更新日期:2018-05-25 00:00:00

  • Tissue-mimicking gelatin-agar gels for use in magnetic resonance imaging phantoms.

    abstract::A new variety of tissue-mimicking materials for use in 1H nuclear magnetic resonance (NMR) phantoms has been developed and extensively tested, principally at 10 MHz and at room temperature. The materials can be formed with a broad range of T1's and T2's representative of soft tissues. They are mixtures of various perc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596219

    authors: Blechinger JC,Madsen EL,Frank GR

    更新日期:1988-07-01 00:00:00

  • Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator.

    abstract:PURPOSE:To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. METHODS:In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4719962

    authors: Lundh O,Rechatin C,Faure J,Ben-Ismaïl A,Lim J,De Wagter C,De Neve W,Malka V

    更新日期:2012-06-01 00:00:00

  • SU-E-T-231: Comparison of Beam Characteristics of Small Field 6 MeV Electrons as Replacement for Superficial X Ray Beam.

    abstract:PURPOSE:To compare beam characteristics of superficial X-rays with 6 MeV Electrons for the purpose of replacing superficial treatments with electron fields for skin lesions. METHODS:Electron beam cutouts were made with 12mm thickness cerrobend in diameters 2-5 cm to match superficial X-ray machine cones. Central axis ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735294

    authors: Avadhani J,Sasidharan S,Carton C,Lowen M,Klapproth T,Licitra C

    更新日期:2012-06-01 00:00:00

  • Investigation of basic imaging properties in digital radiography. 9. Effect of displayed grey levels on signal detection.

    abstract::Results of an 18-alternative forced-choice experiment have shown that observers were capable of detecting a signal with a contrast of 1 in terms of 10-bit data which were displayed on a CRT monitor with an 8-bit video generator and a window width setting of 1024. We investigated the conditions under which 10-bit signa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595919

    authors: Giger ML,Ohara K,Doi K

    更新日期:1986-05-01 00:00:00

  • A general model of microcirculatory blood flow effects in gradient sensitized MRI.

    abstract::A general expression is derived for the NMR signal from a fluid undergoing random directional flow such as encountered within the microcirculation. The dependence of the echo amplitude on flow velocity, sample morphology, and experimental parameters are described in terms of a temporal velocity autocorrelation functio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597170

    authors: Kennan RP,Gao JH,Zhong J,Gore JC

    更新日期:1994-04-01 00:00:00

  • MR acoustic radiation force imaging: in vivo comparison to ultrasound motion tracking.

    abstract::MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3120289

    authors: Huang Y,Curiel L,Kukic A,Plewes DB,Chopra R,Hynynen K

    更新日期:2009-06-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • Breast tumor segmentation in 3D automatic breast ultrasound using Mask scoring R-CNN.

    abstract:PURPOSE:Automatic breast ultrasound (ABUS) imaging has become an essential tool in breast cancer diagnosis since it provides complementary information to other imaging modalities. Lesion segmentation on ABUS is a prerequisite step of breast cancer computer-aided diagnosis (CAD). This work aims to develop a deep learnin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14569

    authors: Lei Y,He X,Yao J,Wang T,Wang L,Li W,Curran WJ,Liu T,Xu D,Yang X

    更新日期:2020-10-30 00:00:00

  • Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: pilot study.

    abstract::Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wal...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1796171

    authors: Li P,Napel S,Acar B,Paik DS,Jeffrey RB Jr,Beaulieu CF

    更新日期:2004-10-01 00:00:00

  • Spatiotemporal filtering of MR-temperature artifacts arising from bowel motion during transurethral MR-HIFU.

    abstract:PURPOSE:Transurethral MR-HIFU is a minimally invasive image-guided treatment for localized prostate cancer that enables precise targeting of tissue within the gland. The treatment is performed within a clinical MRI to obtain real-time MR thermometry used as an active feedback to control the spatial heating pattern in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897382

    authors: Schmitt A,Mougenot C,Chopra R

    更新日期:2014-11-01 00:00:00

  • SU-E-T-462: Calculation of Prescribed Dose for Permanent Implant with Cs-131 Using LQ Equation including Resensitization.

    abstract:PURPOSE:To develop a new biological equivalent dose (BED) formulism that includes repair, repopulation and resensitization (redistribution and reoxygenation), and can be used to calculate prescribed dose for permanent implant with Cs-131. METHODS:Because of lack of sufficient clinical data, the prescribed dose with ne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735551

    authors: Luo W,Aryal P,Randall M

    更新日期:2012-06-01 00:00:00

  • "Battered data"--some clinical effects of the abuse of multiple regression methods: the NSD.

    abstract::The NSD equation, D = 1850 x T0.11 x N0.24, is a celebrated transmogrification of Cohen's two well-known collations of data on response to clinical irradiations (3 degrees erythema and 0.90 ablation of skin cancer) in which the relation of D and T is fixed by the data selected by Cohen and the additional constraint th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595034

    authors: Herbert DE Jr

    更新日期:1981-11-01 00:00:00

  • Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior.

    abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12285

    authors: Bian Z,Zeng D,Zhang Z,Gong C,Tian X,Yan G,Huang J,Guo H,Chen B,Zhang J,Feng Q,Chen W,Ma J

    更新日期:2017-09-01 00:00:00

  • Exposure artifacts in raster scanned equalization radiography.

    abstract::The image artifacts characteristic of a scanning chest radiographic system are reviewed. The technique employs a pulsed beam of radiation swept in an overlapping raster pattern that can result in severe ripple and scan line artifacts with improper scanning parameters. A one-dimensional treatment of the scanner geometr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595492

    authors: Plewes DB,Vogelstein E

    更新日期:1984-03-01 00:00:00

  • Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging.

    abstract:PURPOSE:The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892174

    authors: Cho HM,Barber WC,Ding H,Iwanczyk JS,Molloi S

    更新日期:2014-09-01 00:00:00

  • Application of the TRS 483 code of practice for reference and relative dosimetry in tomotherapy.

    abstract:PURPOSE:To apply the recent code of practice from the IAEA/AAPM, TRS 483, to helical tomotherapy (HT) for reference and relative dosimetry obtaining correction factors for the Exradin A1SL ionization chamber. METHODS:The beam quality correction factor for the A1SL chamber was obtained through three different approache...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13855

    authors: Lopes MDC,Santos T,Ventura T,Capela M

    更新日期:2019-12-01 00:00:00

  • Robust experiment design for estimating myocardial beta adrenergic receptor concentration using PET.

    abstract::Myocardial beta adrenergic receptor (beta-AR) concentration can substantially decrease in congestive heart failure and significantly increase in chronic volume overload, such as in severe aortic valve regurgitation. Positron emission tomography (PET) with an appropriate ligand-receptor model can be used for noninvasiv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2402585

    authors: Salinas C,Muzic RF Jr,Ernsberger P,Saidel GM

    更新日期:2007-01-01 00:00:00

  • Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images.

    abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596610

    authors: Yin FF,Giger ML,Doi K,Metz CE,Vyborny CJ,Schmidt RA

    更新日期:1991-09-01 00:00:00

  • A controlled phantom study of a noise equalization algorithm for detecting microcalcifications in digital mammograms.

    abstract::We report on some extensions and further developments of a well-known microcalcification detection algorithm based on adaptive noise equalization. Tissue equivalent phantom images with and without labeled microcalcifications were subjected to this algorithm, and analyses of results revealed some shortcomings in the ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1359245

    authors: Gürün OO,Fatouros PP,Kuhn GM,de Paredes ES

    更新日期:2001-04-01 00:00:00

  • SU-E-T-558: Assessing the Effect of Inter-Fractional Motion in Esophageal Sparing Plans.

    abstract:PURPOSE:To compare esophageal dose distributions in esophageal sparing IMRT plans with predicted dose distributions which include the effect of inter-fraction motion. METHODS:Seven lung cancer patients were used, each with a standard and an esophageal sparing plan (74Gy, 2Gy fractions). The average max dose to esophag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735647

    authors: Williamson R,Bluett J,Niedzielski J,Liao Z,Gomez D,Court L

    更新日期:2012-06-01 00:00:00

  • Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.

    abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812609

    authors: Niu H,Hsi WC,Chu JC,Kirk MC,Kouwenhoven E

    更新日期:2004-12-01 00:00:00

  • Evaluation of CT-based lean-body SUV.

    abstract:PURPOSE:The authors introduce a novel method for defining standardized uptake values (SUVs) in PET∕CT based on routinely collected CT data. The goal of the study is to reduce, if possible, the variability of SUV in a heterogeneous population. Two well established methods for defining SUV are based on body weight (BW) a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4816656

    authors: Hamill JJ,Sunderland JJ,LeBlanc AK,Kojima CJ,Wall J,Martin EB

    更新日期:2013-09-01 00:00:00

  • Implementation of a three-dimensional compensation system based on computed tomography generated surface contours and tissue inhomogeneities.

    abstract::A computed tomography (CT) based system that compensates for patient surface contour and internal tissue inhomogeneity was implemented in our clinic. The compensators are fabricated with a mixture of tin granules and bee's wax. The tin/wax mixture was optimized for tin granule size and tin granule to wax ratio. The na...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597303

    authors: Jursinic PA,Podgorsak MB,Paliwal BR

    更新日期:1994-03-01 00:00:00