Breast tumor segmentation in 3D automatic breast ultrasound using Mask scoring R-CNN.

Abstract:

PURPOSE:Automatic breast ultrasound (ABUS) imaging has become an essential tool in breast cancer diagnosis since it provides complementary information to other imaging modalities. Lesion segmentation on ABUS is a prerequisite step of breast cancer computer-aided diagnosis (CAD). This work aims to develop a deep learning-based method for breast tumor segmentation using three-dimensional (3D) ABUS automatically. METHODS:For breast tumor segmentation in ABUS, we developed a Mask scoring region-based convolutional neural network (R-CNN) that consists of five subnetworks, that is, a backbone, a regional proposal network, a region convolutional neural network head, a mask head, and a mask score head. A network block building direct correlation between mask quality and region class was integrated into a Mask scoring R-CNN based framework for the segmentation of new ABUS images with ambiguous regions of interest (ROIs). For segmentation accuracy evaluation, we retrospectively investigated 70 patients with breast tumor confirmed with needle biopsy and manually delineated on ABUS, of which 40 were used for fivefold cross-validation and 30 were used for hold-out test. The comparison between the automatic breast tumor segmentations and the manual contours was quantified by I) six metrics including Dice similarity coefficient (DSC), Jaccard index, 95% Hausdorff distance (HD95), mean surface distance (MSD), residual mean square distance (RMSD), and center of mass distance (CMD); II) Pearson correlation analysis and Bland-Altman analysis. RESULTS:The mean (median) DSC was 85% ± 10.4% (89.4%) and 82.1% ± 14.5% (85.6%) for cross-validation and hold-out test, respectively. The corresponding HD95, MSD, RMSD, and CMD of the two tests was 1.646 ± 1.191 and 1.665 ± 1.129 mm, 0.489 ± 0.406 and 0.475 ± 0.371 mm, 0.755 ± 0.755 and 0.751 ± 0.508 mm, and 0.672 ± 0.612 and 0.665 ± 0.729 mm. The mean volumetric difference (mean and ± 1.96 standard deviation) was 0.47 cc ([-0.77, 1.71)) for the cross-validation and 0.23 cc ([-0.23 0.69]) for hold-out test, respectively. CONCLUSION:We developed a novel Mask scoring R-CNN approach for the automated segmentation of the breast tumor in ABUS images and demonstrated its accuracy for breast tumor segmentation. Our learning-based method can potentially assist the clinical CAD of breast cancer using 3D ABUS imaging.

journal_name

Med Phys

journal_title

Medical physics

authors

Lei Y,He X,Yao J,Wang T,Wang L,Li W,Curran WJ,Liu T,Xu D,Yang X

doi

10.1002/mp.14569

subject

Has Abstract

pub_date

2020-10-30 00:00:00

eissn

0094-2405

issn

2473-4209

pub_type

杂志文章
  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • Evaluation of a compact multicontrast and multiresolution X-ray phase contrast edge illumination system for small animal imaging.

    abstract:PURPOSE:In this work the performance of a compact multiresolution and multicontrast x-ray phase system based on edge illumination is investigated. It has been designed for small animal imaging and with a limited footprint for ease of deployment in laboratories. METHODS:The presented edge illumination system is based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14553

    authors: Massimi L,Meganck JA,Towns R,Olivo A,Endrizzi M

    更新日期:2020-10-27 00:00:00

  • Basic imaging properties of a computed radiographic system with photostimulable phosphors.

    abstract::We measured the characteristic curve, modulation transfer function (MTF), and the Wiener spectrum of a commercially available computed radiographic (CR) system with photostimulable phosphor plate (imaging plate, IP). The characteristic curve (system response) obtained by an inverse-square x-ray sensitometry showed a w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596402

    authors: Fujita H,Ueda K,Morishita J,Fujikawa T,Ohtsuka A,Sai T

    更新日期:1989-01-01 00:00:00

  • Study of dosimetry consistency for kilovoltage x-ray beams.

    abstract::In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598448

    authors: Ma CM,Li XA,Seuntjens JP

    更新日期:1998-12-01 00:00:00

  • A moving blocker system for cone-beam computed tomography scatter correction.

    abstract:PURPOSE:Scatter contamination in cone-beam computed tomography (CBCT) degrades the image quality by introducing shading artifacts. A moving-blocker-based approach has been proposed to simultaneously estimate scatter and reconstruct the complete volume within field of view (FOV) from a single CBCT scan. Promising result...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4811086

    authors: Ouyang L,Song K,Wang J

    更新日期:2013-07-01 00:00:00

  • SU-E-J-186: CT Textures Can be Predictive for Tumor Shrinkage.

    abstract:PURPOSE:To determine if NSCLC GTV CT textures can be predictive for tumor shrinkage after proton therapy with concurrent chemotherapy. METHODS:Simulation and weekly 4DCTs were obtained from 25 patients with locally advanced NSCLC treated by proton therapy at a 74 Gy dose level with concurrent chemotherapy. In-house de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735027

    authors: Hunter L,Chen Y,Zhang L,Liao Z,Dong L,Court L

    更新日期:2012-06-01 00:00:00

  • Laser heating of thermoluminescent plates: application to intraoperative radiotherapy.

    abstract::A new system of radiation dose mapping based on laser heating of thermoluminescent dosimetric plates (TLDP) has been developed. Application of this technique to intraoperative radiotherapy (IORT) has been investigated. Preliminary results show that TLDP are a possible alternative to radiological films and ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597725

    authors: Beteille D,Setzkom R,Prévost H,Dusseau L,Fesquet J,Gasiot J,Muraro S,Delard R,Dubois JB,Ailleres N,Missous O

    更新日期:1996-08-01 00:00:00

  • Experimental verification of EGSnrc Monte Carlo calculated depth doses within a realistic parallel magnetic field in a polystyrene phantom.

    abstract:PURPOSE:Integrating a linac with a magnetic resonance imager (MRI) will revolutionize the accuracy of external beam radiation treatments. Irradiating in the presence of a strong magnetic field, however, will modify the dose distribution. These dose modifications have been investigated previously, mainly using Monte Car...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12413

    authors: Ghila A,Steciw S,Fallone BG,Rathee S

    更新日期:2017-09-01 00:00:00

  • Motion estimation for cardiac functional analysis using two x-ray computed tomography scans.

    abstract:PURPOSE:This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12425

    authors: Fung GSK,Ciuffo L,Ashikaga H,Taguchi K

    更新日期:2017-09-01 00:00:00

  • The effect of coupling materials on specific absorption rate distributions at 915 MHz.

    abstract::Deionized water is commonly used to couple microwave applicators to the patient surface in the administration of local hyperthermia. Profiles of the specific absorption rate (SAR) at 1-cm depth show that deionized water coupling significantly distorts the SAR distributions of the Clini-Therm 915-MHz 10 X 10 and 15 X 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595881

    authors: Waterman FM,Nerlinger RE

    更新日期:1986-05-01 00:00:00

  • A limited-angle intrafraction verification (LIVE) system for radiation therapy.

    abstract:PURPOSE:Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4861820

    authors: Ren L,Zhang Y,Yin FF

    更新日期:2014-02-01 00:00:00

  • Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification.

    abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1668391

    authors: Vetterli D,Riem H,Aebersold DM,Greiner RH,Manser P,Cossmann P,Kemmerling L,Born EJ,Mini R

    更新日期:2004-04-01 00:00:00

  • X-ray imaging with amorphous selenium: optimal spectra for digital mammography.

    abstract::The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597688

    authors: Fahrig R,Rowlands JA,Yaffe MJ

    更新日期:1996-04-01 00:00:00

  • Technical Note: Comparison of megavoltage, dual-energy, and single-energy CT-based μ-maps for a four-channel breast coil in PET/MRI.

    abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12407

    authors: Patrick JC,Terry Thompson R,So A,Butler J,Faul D,Stodilka RZ,Yartsev S,Prato FS,Gaede S

    更新日期:2017-09-01 00:00:00

  • Computed tomography scanning with simultaneous patient translation.

    abstract::This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an intersc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596464

    authors: Crawford CR,King KF

    更新日期:1990-11-01 00:00:00

  • Quantitative assessment of bone mineral by photon scattering: accuracy and precision considerations.

    abstract::A method to determine the bone mineral density of the calcaneum has been reported earlier by our laboratory. In this method, the calcaneum is irradiated by a 60-keV photon beam from 241Am source and both the coherent and Compton scattered photons are detected by a high-purity Ge detector. The bone mineral density is d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595669

    authors: Shukla SS,Karellas A,Leichter I,Craven JD,Greenfield MA

    更新日期:1985-07-01 00:00:00

  • Accounting for the fringe magnetic field from the bending magnet in a Monte Carlo accelerator treatment head simulation.

    abstract:PURPOSE:Monte Carlo (MC) simulation can be used for accurate electron beam treatment planning and modeling. Measurement of large electron fields, with the applicator removed and secondary collimator wide open, has been shown to provide accurate simulation parameters, including asymmetry in the measured dose, for the fu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3592640

    authors: O'Shea TP,Foley MJ,Faddegon BA

    更新日期:2011-06-01 00:00:00

  • Impact of calibration methods for color medical displays on interpreting brain SPECT images.

    abstract:PURPOSE:Color images are visualized on medical monitors that are adjusted by a grayscale standard display function (GSDF) or γ2.2. Although the GSDF is visually displayed as a linear graded grayscale, it does not specify how color medical images should be presented. On the other hand, the usual gamma setting for color ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13532

    authors: Shibutani T,Onoguchi M,Yoneyama H,Nakajima K,Matsuo S,Bamba Y,Saito S

    更新日期:2019-06-01 00:00:00

  • Systematic feasibility analysis of performing elastography using reduced dose CT lung image pairs.

    abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14112

    authors: Hasse K,Hsieh SS,O'Connell D,Stiehl B,Min Y,Neylon J,Low DA,Santhanam AP

    更新日期:2020-08-01 00:00:00

  • A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

    abstract:PURPOSE:Partial scan reconstruction (PSR) artifacts are present in myocardial perfusion imaging using dynamic multidetector computed tomography (MDCT). PSR artifacts appear as temporal CT number variations due to inconsistencies in the angular data range used to reconstruct images and compromise the quantitative value ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3665767

    authors: Ramirez-Giraldo JC,Yu L,Kantor B,Ritman EL,McCollough CH

    更新日期:2012-01-01 00:00:00

  • FRoG: An independent dose and LETd prediction tool for proton therapy at ProBeam® facilities.

    abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14417

    authors: Kopp B,Fuglsang Jensen M,Mein S,Hoffmann L,Nyström H,Falk M,Haberer T,Abdollahi A,Debus J,Mairani A

    更新日期:2020-10-01 00:00:00

  • Real-time 4DMRI-based internal target volume definition for moving lung tumors.

    abstract:PURPOSE:In photon radiotherapy, respiratory-induced target motion can be accounted for by internal target volumes (ITV) or mid-ventilation target volumes (midV) defined on the basis of four-dimensional computed tomography (4D-CT). Intrinsic limitations of these approaches can result in target volumes that are not repre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14023

    authors: Rabe M,Thieke C,Düsberg M,Neppl S,Gerum S,Reiner M,Nicolay NH,Schlemmer HP,Debus J,Dinkel J,Landry G,Parodi K,Belka C,Kurz C,Kamp F

    更新日期:2020-04-01 00:00:00

  • Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study.

    abstract:PURPOSE:To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. METHODS:A total of eight clinical lung tumor cases were recalculated using Monte Carlo me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938580

    authors: Oborn BM,Ge Y,Hardcastle N,Metcalfe PE,Keall PJ

    更新日期:2016-01-01 00:00:00

  • Ultrasonic Nakagami-parameter characterization of parotid-gland injury following head-and-neck radiotherapy: a feasibility study of late toxicity.

    abstract:PURPOSE:The study aims to investigate whether Nakagami parameters--estimated from the statistical distribution of the backscattered ultrasound radio-frequency (RF) signals--could provide a means for quantitative characterization of parotid-gland injury resulting from head-and-neck radiotherapy. METHODS:A preliminary c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4862507

    authors: Yang X,Tridandapani S,Beitler JJ,Yu DS,Wu N,Wang Y,Bruner DW,Curran WJ,Liu T

    更新日期:2014-02-01 00:00:00

  • Pelvic multi-organ segmentation on cone-beam CT for prostate adaptive radiotherapy.

    abstract:BACKGROUND AND PURPOSE:The purpose of this study is to develop a deep learning-based approach to simultaneously segment five pelvic organs including prostate, bladder, rectum, left and right femoral heads on cone-beam CT (CBCT), as required elements for prostate adaptive radiotherapy planning. MATERIALS AND METHODS:We...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14196

    authors: Fu Y,Lei Y,Wang T,Tian S,Patel P,Jani AB,Curran WJ,Liu T,Yang X

    更新日期:2020-08-01 00:00:00

  • Modification of the TASMIP x-ray spectral model for the simulation of microfocus x-ray sources.

    abstract:PURPOSE:The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammograp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4837220

    authors: Sisniega A,Desco M,Vaquero JJ

    更新日期:2014-01-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • Poster - Thur Eve - 59: Dosimetric evaluation on the variation of PTV coverage due to patient size reduction using the prostate dose-volume factor in prostate radiotherapy.

    abstract::We proposed to use the prostate dose-volume factor (PDVF), derived from the dose-volume dataset of planning target volume (PTV) in prostate radiotherapy to evaluate treatment plans of prostate volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT). To demonstrate plan evaluation using PDVF...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740167

    authors: Chow J,Jiang R,Markel D

    更新日期:2012-07-01 00:00:00

  • Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector.

    abstract:PURPOSE:To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. METHODS:This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically moti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4875688

    authors: Zhao Z,Gang GJ,Siewerdsen JH

    更新日期:2014-06-01 00:00:00

  • A controlled phantom study of a noise equalization algorithm for detecting microcalcifications in digital mammograms.

    abstract::We report on some extensions and further developments of a well-known microcalcification detection algorithm based on adaptive noise equalization. Tissue equivalent phantom images with and without labeled microcalcifications were subjected to this algorithm, and analyses of results revealed some shortcomings in the ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1359245

    authors: Gürün OO,Fatouros PP,Kuhn GM,de Paredes ES

    更新日期:2001-04-01 00:00:00