Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging.

Abstract:

PURPOSE:The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. METHODS:The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A109Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. RESULTS:A maximum output count rate of 100 million counts per second per square millimeter (cps/mm2) has been obtained (1 million cps per 100×100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a 109Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm(-1). The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. CONCLUSIONS:The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

journal_name

Med Phys

journal_title

Medical physics

authors

Cho HM,Barber WC,Ding H,Iwanczyk JS,Molloi S

doi

10.1118/1.4892174

subject

Has Abstract

pub_date

2014-09-01 00:00:00

pages

091903

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

41

pub_type

杂志文章
  • Ultrasonic Nakagami-parameter characterization of parotid-gland injury following head-and-neck radiotherapy: a feasibility study of late toxicity.

    abstract:PURPOSE:The study aims to investigate whether Nakagami parameters--estimated from the statistical distribution of the backscattered ultrasound radio-frequency (RF) signals--could provide a means for quantitative characterization of parotid-gland injury resulting from head-and-neck radiotherapy. METHODS:A preliminary c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4862507

    authors: Yang X,Tridandapani S,Beitler JJ,Yu DS,Wu N,Wang Y,Bruner DW,Curran WJ,Liu T

    更新日期:2014-02-01 00:00:00

  • An experimentally validated couch and MLC tracking simulator used to investigate hybrid couch-MLC tracking.

    abstract:PURPOSE/OBJECTIVE:Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both techniques still have residual dosimetric errors. Here, we first propose and experimentally validate a software tool to simulate couch and MLC tracking, and then use ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12104

    authors: Toftegaard J,Hansen R,Ravkilde T,Macek K,Poulsen PR

    更新日期:2017-03-01 00:00:00

  • Accuracy of deformable image registration on magnetic resonance images in digital and physical phantoms.

    abstract:PURPOSE:Accurate deformable image registration is necessary for longitudinal studies. The error associated with commercial systems has been evaluated using computed tomography (CT). Several in-house algorithms have been evaluated for use with magnetic resonance imaging (MRI), but there is still relatively little inform...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12406

    authors: Ger RB,Yang J,Ding Y,Jacobsen MC,Fuller CD,Howell RM,Li H,Jason Stafford R,Zhou S,Court LE

    更新日期:2017-10-01 00:00:00

  • Computer-assisted beam modeling for particle therapy.

    abstract:PURPOSE:To develop a computer-driven and thus less user-dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS:In a first step, experimental measurements were performed for proton and carbon ion energies i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14647

    authors: Fuchs H,Elia A,Resch AF,Kuess P,Lühr A,Vidal M,Grevillot L,Georg D

    更新日期:2020-12-07 00:00:00

  • Poster - Thur Eve - 64: Evaluation of SmartArc and RapidArc for lung SBRT treatment planning and delivery.

    abstract:OBJECTIVES:To evaluate the performance of RapidArc® (Eclipse 10.0.28) and SmartArc® (Pinnacle 9.0) radiotherapy plans for lung stereotactic body radiation therapy (SBRT) in terms of dosimetric plan quality, delivery efficiency, inhomogeneity corrections and accuracy of dose delivery using a custom-built heterogeneity i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740172

    authors: Fakir H,Hoover D,Chen JZ

    更新日期:2012-07-01 00:00:00

  • Investigating energy deposition in glandular tissues for mammography using multiscale Monte Carlo simulations.

    abstract:PURPOSE:To investigate energy deposition in glandular tissues of the breast on macro- and microscopic length scales in the context of mammography. METHODS:Multiscale mammography models of breasts are developed, which include segmented, voxelized macroscopic tissue structure as well as nine regions of interest (ROIs) e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13372

    authors: Oliver PAK,Thomson RM

    更新日期:2019-03-01 00:00:00

  • Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233.

    abstract:BACKGROUND:The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. AIMS:This report offers updated testing guid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13763

    authors: Samei E,Bakalyar D,Boedeker KL,Brady S,Fan J,Leng S,Myers KJ,Popescu LM,Ramirez Giraldo JC,Ranallo F,Solomon J,Vaishnav J,Wang J

    更新日期:2019-11-01 00:00:00

  • Development and validation of a CT-3D rotational angiography registration method for AVM radiosurgery.

    abstract::In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, whil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1751252

    authors: Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Colombo F,Perini S

    更新日期:2004-06-01 00:00:00

  • On the effective point of measurement in megavoltage photon beams.

    abstract::This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the cham...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2201147

    authors: Kawrakow I

    更新日期:2006-06-01 00:00:00

  • SU-E-J-194: The Impact of Different Imaging Measures on Treatment Response Assessment of Bone Metastases.

    abstract:PURPOSE:Several treatment response metrics, such as RECIST and PERCIST, have been established for assessing individual solid tumors. However, metastatic prostate cancer poses a unique challenge to these metrics because bone lesions are often numerous and non-measureable. This study investigated the impact of using diff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735035

    authors: Morrison C,Liu G,Jeraj R

    更新日期:2012-06-01 00:00:00

  • Discrimination analysis of breast calcifications using x-ray dark-field radiography.

    abstract:BACKGROUND:X-ray dark-field radiography could enhance mammography by providing more information on imaged tissue and microcalcifications. The dark field signal is a measure of small angle scattering and can thus provide additional information on the imaged materials. This information can be useful for material distinct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14043

    authors: Rauch T,Rieger J,Pelzer G,Horn F,Erber R,Wunderle M,Emons J,Nabieva N,Fuhrich N,Michel T,Hartmann A,Fasching PA,Anton G

    更新日期:2020-04-01 00:00:00

  • Determination of primary dose in 60Co gamma beam using a small attenuator.

    abstract::A measurement technique previously proposed for determining dose from primary radiation has been tested using 60Co gamma rays. It is shown that the dose from primary radiation is reliably determined for field sizes of 10 X 10 and 20 X 20 cm2 at depths of 0.5, 5, and 10 cm in water. With further development this techni...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596534

    authors: Nizin PS,Kase KR

    更新日期:1990-01-01 00:00:00

  • Real-time direct diaphragm tracking using kV imaging on a standard linear accelerator.

    abstract:PURPOSE:As the predominant driver of respiratory motion, the diaphragm represents a key surrogate for motion management during the irradiation of thoracic cancers. Existing approaches to diaphragm tracking often produce phase-based estimates, suffer from lateral side failures or are not executable in real-time. In this...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13738

    authors: Hindley N,Keall P,Booth J,Shieh CC

    更新日期:2019-10-01 00:00:00

  • Beam modeling and verification of a photon beam multisource model.

    abstract::Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1898485

    authors: Ahnesjö A,Weber L,Murman A,Saxner M,Thorslund I,Traneus E

    更新日期:2005-06-01 00:00:00

  • SU-E-T-576: Investigation of Combining Modulated Electron Beams with Intensity Modulated Photons for Radiation Therapy of Breast Cases.

    abstract:PURPOSE:Modulated electron radiation therapy (MERT) can offer significant advantages for breast treatments over conventional radiotherapy in terms of sparing distal critical structures. While intensity modulated radiation therapy (IMRT) has the advantage of achieving better dose homogeneity inside the target combining ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735665

    authors: Eldib A,Li J,Jin L,Ma C

    更新日期:2012-06-01 00:00:00

  • Contrast-detail analysis of image degradation due to lossy compression.

    abstract::A contrast-detail (CD) experiment was performed to study the effect of lossy compression on computed radiographic (CR) images. Digital CR images of a phantom were compressed by quantizing the full-frame discrete cosine transform and Huffman encoding the result. Since low-contrast detectability is directly linked to an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597489

    authors: Cook LT,Insana MF,McFadden MA,Hall TJ,Cox GG

    更新日期:1995-06-01 00:00:00

  • Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays.

    abstract::Flat-panel imagers consisting of the first large area, self-scanning, pixelated, solid-state arrays made with hydrogenated amorphous silicon (a-Si:H) are under development by the authors for applications in diagnostic x-ray and megavoltage radiotherapy imaging. The arrays, designated by the acronym MASDA for multi-ele...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596802

    authors: Antonuk LE,Boudry J,Huang W,McShan DL,Morton EJ,Yorkston J,Longo MJ,Street RA

    更新日期:1992-11-01 00:00:00

  • Accuracy of registration algorithms in subtraction CT of the lungs: A digital phantom study.

    abstract:PURPOSE:The purpose of this study was to assess, using an anthropomorphic digital phantom, the accuracy of algorithms in registering precontrast and contrast-enhanced computed tomography (CT) chest images for generation of iodine maps of the pulmonary parenchyma via temporal subtraction. MATERIALS AND METHODS:The XCAT...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13496

    authors: Grob D,Oostveen L,Rühaak J,Heldmann S,Mohr B,Michielsen K,Dorn S,Prokop M,Kachelrieβ M,Brink M,Sechopoulos I

    更新日期:2019-05-01 00:00:00

  • The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: characterization of two Cerenkov discrimination methods.

    abstract::New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2897966

    authors: Frelin AM,Fontbonne JM,Ban G,Colin J,Labalme M,Batalla A,Vela A,Boher P,Braud M,Leroux T

    更新日期:2008-05-01 00:00:00

  • Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes.

    abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752083

    authors: Waring CS,Bax JS,Samarabandu A,Holdsworth DW,Fenster A,Lacefield JC

    更新日期:2012-10-01 00:00:00

  • Detection nonuniformity measurements and corrections for cone beam transmission CT on a gamma camera.

    abstract::Cone beam transmission CT (CB-CT) improves SPECT imaging by providing high-quality attenuation maps for attenuation compensation and for correlated SPECT and CT imaging. The present work measures the detection nonuniformity for CB-CT implemented with a gamma camera, and applies nonuniformity corrections to make CB-CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596838

    authors: Manglos SH,Capone RB,Bassano DA

    更新日期:1992-03-01 00:00:00

  • A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject.

    abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941954

    authors: Hsieh SS,Chesler DA,Fleischmann D,Pelc NJ

    更新日期:2016-03-01 00:00:00

  • Development and evaluation of a case-based reasoning classifier for prediction of breast biopsy outcome with BI-RADS lexicon.

    abstract::Approximately 70-85% of breast biopsies are performed on benign lesions. To reduce this high number of biopsies performed on benign lesions, a case-based reasoning (CBR) classifier was developed to predict biopsy results from BI-RADS findings. We used 1433 (931 benign) biopsy-proven mammographic cases. CBR similarity ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1501140

    authors: Bilska-Wolak AO,Floyd CE Jr

    更新日期:2002-09-01 00:00:00

  • Automatic tumor segmentation in breast ultrasound images using a dilated fully convolutional network combined with an active contour model.

    abstract:PURPOSE:Due to the low contrast, blurry boundaries, and large amount of shadows in breast ultrasound (BUS) images, automatic tumor segmentation remains a challenging task. Deep learning provides a solution to this problem, since it can effectively extract representative features from lesions and the background in BUS i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13268

    authors: Hu Y,Guo Y,Wang Y,Yu J,Li J,Zhou S,Chang C

    更新日期:2019-01-01 00:00:00

  • Monte Carlo dose calculations for a new ovoid shield system for carcinoma of the uterine cervix.

    abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598459

    authors: Weeks KJ

    更新日期:1998-12-01 00:00:00

  • Dose distributions in bifurcated coronary vessels treated with catheter-based photon and beta emitters in intravascular brachytherapy.

    abstract::The dose distributions in the bifurcated vessels treated with intravascular brachytherapyline sources are complicated and depend on the bifurcation geometry consisting of a main and a branch vessel at different angles. To investigate the dosimetric effects at the bifurcation, calculations were performed on branching v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1582813

    authors: Yue N,Roberts KB,Pfau SE,Nath R

    更新日期:2003-07-01 00:00:00

  • A method for characterizing and matching CT image quality across CT scanners from different manufacturers.

    abstract:PURPOSE:The purpose of this study was to quantitatively characterize the fundamental aspects of image quality (IQ) associated with different computed tomography (CT) reconstruction algorithms, the resolution, noise texture, noise magnitude per dose, and use those data to devise a methodology to match IQ between differe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12554

    authors: Winslow J,Zhang Y,Samei E

    更新日期:2017-11-01 00:00:00

  • Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification.

    abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1668391

    authors: Vetterli D,Riem H,Aebersold DM,Greiner RH,Manser P,Cossmann P,Kemmerling L,Born EJ,Mini R

    更新日期:2004-04-01 00:00:00

  • The use of a diode matrix in commissioning activities for electron energies > or = 9 MeV: a feasibility study.

    abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3081414

    authors: Borca VC,Pasquino M,Ozzello F,Tofani S

    更新日期:2009-04-01 00:00:00

  • A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery.

    abstract::The trend toward conformal techniques in stereotactic radiosurgery necessitates an accurate and practical method for verification of irregular three-dimensional dose distributions. This work presents the design and evaluation of a phantom system facilitating the measurement of conformal dose distributions using one or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598962

    authors: Robar JL,Clark BG

    更新日期:2000-05-01 00:00:00