Development and evaluation of a case-based reasoning classifier for prediction of breast biopsy outcome with BI-RADS lexicon.

Abstract:

:Approximately 70-85% of breast biopsies are performed on benign lesions. To reduce this high number of biopsies performed on benign lesions, a case-based reasoning (CBR) classifier was developed to predict biopsy results from BI-RADS findings. We used 1433 (931 benign) biopsy-proven mammographic cases. CBR similarity was defined using either the Hamming or Euclidean distance measure over case features. Ten features represented each case: calcification distribution, calcification morphology, calcification number, mass margin, mass shape, mass density, mass size, associated findings, special cases, and age. Performance was evaluated using Round Robin sampling, Receiver Operating Characteristic (ROC) analysis, and bootstrap. To determine the most influential features for the CBR, an exhaustive feature search was performed over all possible feature combinations (1022) and similarity thresholds. Influential features were defined as the most frequently occurring features in the feature subsets with the highest partial ROC areas (0.90AUC). For CBR with Hamming distance, the most influential features were found to be mass margin, calcification morphology, age, calcification distribution, calcification number, and mass shape, resulting in an 0.90AUC of 0.33. At 95% sensitivity, the Hamming CBR would spare from biopsy 34% of the benign lesions. At 98% sensitivity, the Hamming CBR would spare 27% benign lesions. For the CBR with Euclidean distance, the most influential feature subset consisted of mass margin, calcification morphology, age, mass density, and associated findings, resulting in 0.90AUC of 0.37. At 95% sensitivity, the Euclidean CBR would spare from biopsy 41% benign lesions. At 98% sensitivity, the Euclidean CBR would spare 27% benign lesions. The profile of cases spared by both distance measures at 98% sensitivity indicates that the CBR is a potentially useful diagnostic tool for the classification of mammographic lesions, by recommending short-term follow-up for likely benign lesions that is in agreement with final biopsy results and mammographer's intuition.

journal_name

Med Phys

journal_title

Medical physics

authors

Bilska-Wolak AO,Floyd CE Jr

doi

10.1118/1.1501140

subject

Has Abstract

pub_date

2002-09-01 00:00:00

pages

2090-100

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

29

pub_type

杂志文章
  • Validation of OSLD and a treatment planning system for surface dose determination in IMRT treatments.

    abstract:PURPOSE:To evaluate the accuracy of skin dose determination for composite multibeam 3D conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT) treatments using optically stimulated luminescent dosimeters (OSLDs) and Eclipse treatment planning system. METHODS:Surface doses measured by OSLDs...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4890795

    authors: Zhuang AH,Olch AJ

    更新日期:2014-08-01 00:00:00

  • Dynamic multiatlas selection-based consensus segmentation of head and neck structures from CT images.

    abstract:PURPOSE:Manual delineation of head and neck (H&N) organ-at-risk (OAR) structures for radiation therapy planning is time consuming and highly variable. Therefore, we developed a dynamic multiatlas selection-based approach for fast and reproducible segmentation. METHODS:Our approach dynamically selects and weights the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13854

    authors: Haq R,Berry SL,Deasy JO,Hunt M,Veeraraghavan H

    更新日期:2019-12-01 00:00:00

  • Tissue-mimicking gelatin-agar gels for use in magnetic resonance imaging phantoms.

    abstract::A new variety of tissue-mimicking materials for use in 1H nuclear magnetic resonance (NMR) phantoms has been developed and extensively tested, principally at 10 MHz and at room temperature. The materials can be formed with a broad range of T1's and T2's representative of soft tissues. They are mixtures of various perc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596219

    authors: Blechinger JC,Madsen EL,Frank GR

    更新日期:1988-07-01 00:00:00

  • SU-E-T-382: An Analysis of VMAT Monthly Quality Assurance.

    abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735470

    authors: Stenbeck J,Oves S,Gebreamlak W,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • Accuracy of EGSnrc calculations at 60Co energies for the response of ion chambers configured with various wall materials and cavity dimensions.

    abstract::In this investigation, five experimental data sets are used to evaluate the ability of the EGSnrc Monte Carlo code to calculate the change in chamber response associated with changes in wall material and cavity dimension at 60Co energies. Calculations of the ratios of response per unit mass of air as a function of cav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3013701

    authors: La Russa DJ,Rogers DW

    更新日期:2008-12-01 00:00:00

  • Technical Note: Impact of region of interest size and location in Gafchromic film dosimetry.

    abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12885

    authors: Gholizadeh Sendani N,Karimian A,Ferreira C,Alaei P

    更新日期:2018-05-01 00:00:00

  • An improved electron energy-loss straggling algorithm for Monte Carlo transport codes.

    abstract::The commonly used Blunck and Leisegang electron energy-loss distribution falls off too rapidly with increasing energy loss. Also, for large thicknesses and/or low-Z media, where their distribution should approach Landau's, it normalizes to 0.92 rather than 1.0, it overestimates the number of very small energy-loss eve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595500

    authors: Weinhous MS,Nath R

    更新日期:1984-05-01 00:00:00

  • Improved gradient-echo 3D magnetic resonance imaging using compressed sensing and Toeplitz encoding with phase-scrambled RF excitation.

    abstract:PURPOSE:To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13987

    authors: Wang H,Liang D,Su S,King KF,Chang Y,Liu X,Zheng H,Ying L

    更新日期:2020-04-01 00:00:00

  • Radionuclide photon dose kernels for internal emitter dosimetry.

    abstract::Photon point dose kernels and absorbed fractions were generated in water for the full photon emission spectrum of each radionuclide of interest in nuclear medicine, by simulating the transport of particles using Monte Carlo. The kernels were then fitted to a mathematical expression. Absorbed fractions for point source...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597670

    authors: Furhang EE,Sgouros G,Chui CS

    更新日期:1996-05-01 00:00:00

  • A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac.

    abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773883

    authors: Gete E,Duzenli C,Milette MP,Mestrovic A,Hyde D,Bergman AM,Teke T

    更新日期:2013-02-01 00:00:00

  • Determination of primary dose in 60Co gamma beam using a small attenuator.

    abstract::A measurement technique previously proposed for determining dose from primary radiation has been tested using 60Co gamma rays. It is shown that the dose from primary radiation is reliably determined for field sizes of 10 X 10 and 20 X 20 cm2 at depths of 0.5, 5, and 10 cm in water. With further development this techni...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596534

    authors: Nizin PS,Kase KR

    更新日期:1990-01-01 00:00:00

  • On the efficiency of photon beam treatment head simulations.

    abstract::The paper presents a theoretical derivation of the photon fluence simulation efficiency in photon beam treatment head simulations without and with bremsstrahlung splitting. The expressions obtained provide a rigorous explanation of the efficiency dependence on scoring zone size and splitting number and explain the lar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1943808

    authors: Kawrakow I

    更新日期:2005-07-01 00:00:00

  • Implementation of a three-dimensional compensation system based on computed tomography generated surface contours and tissue inhomogeneities.

    abstract::A computed tomography (CT) based system that compensates for patient surface contour and internal tissue inhomogeneity was implemented in our clinic. The compensators are fabricated with a mixture of tin granules and bee's wax. The tin/wax mixture was optimized for tin granule size and tin granule to wax ratio. The na...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597303

    authors: Jursinic PA,Podgorsak MB,Paliwal BR

    更新日期:1994-03-01 00:00:00

  • Large field of view distortion assessment in a low-field MR-linac.

    abstract:PURPOSE:MR-guided radiation therapy (RT) offers unparalleled soft tissue contrast for localization and target tracking. However, MRI distortions may be detrimental to high precision RT. This work characterizes the gradient nonlinearity (GNL) and total distortions over the first year of clinical operation of a 0.35T MR-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13467

    authors: Nejad-Davarani SP,Kim JP,Du D,Glide-Hurst C

    更新日期:2019-05-01 00:00:00

  • The effect of angular spread on the intensity distribution of arbitrarily shaped electron beams.

    abstract::Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596252

    authors: Mohan R,Chui CS,Fontenla D,Han K,Ballon D

    更新日期:1988-03-01 00:00:00

  • Linear motion correction in three dimensions applied to dynamic gadolinium enhanced breast imaging.

    abstract::Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accuratel...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598576

    authors: Krishnan S,Chenevert TL,Helvie MA,Londy FL

    更新日期:1999-05-01 00:00:00

  • Robust calculation of effective atomic numbers: the Auto-Z(eff) software.

    abstract:PURPOSE:The most appropriate method of evaluating the effective atomic number necessitates consideration of energy-dependent behavior. Previously, this required quite laborious calculation, which is why many scientists revert to over-simplistic power-law methods. The purpose of this work is to develop user-friendly sof...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3689810

    authors: Taylor ML,Smith RL,Dossing F,Franich RD

    更新日期:2012-04-01 00:00:00

  • Dose and detectability for a cone-beam C-arm CT system revisited.

    abstract:PURPOSE:The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3397465

    authors: Ganguly A,Yoon S,Fahrig R

    更新日期:2010-05-01 00:00:00

  • Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams.

    abstract::An addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water in megavoltage photon beams is presented. This addendum continues the procedure laid out in TG-51 but new kQ data for photon beams, based on Monte Carlo simulations, are presented and recommendations are given to improve the accur...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4866223

    authors: McEwen M,DeWerd L,Ibbott G,Followill D,Rogers DW,Seltzer S,Seuntjens J

    更新日期:2014-04-01 00:00:00

  • A boundary element approach for image-guided near-infrared absorption and scatter estimation.

    abstract::Multimodality NIR spectroscopy systems offer the possibility of region-based vascular and molecular characterization of tissue in vivo. However, computationally efficient 3D image reconstruction algorithms specific to these image-guided systems currently do not exist. Image reconstruction is often based on finite-elem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2795832

    authors: Srinivasan S,Pogue BW,Carpenter C,Yalavarthy PK,Paulsen K

    更新日期:2007-11-01 00:00:00

  • Use of a constrained hierarchical optimization dataset enhances knowledge-based planning as a quality assurance tool for prostate bed irradiation.

    abstract:PURPOSE:To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13163

    authors: Lin YH,Hong LX,Hunt MA,Berry SL

    更新日期:2018-10-01 00:00:00

  • Comparison of measured and estimated maximum skin doses during CT fluoroscopy lung biopsies.

    abstract:PURPOSE:To measure patient-specific maximum skin dose (MSD) associated with CT fluoroscopy (CTF) lung biopsies and to compare measured MSD with the MSD estimated from phantom measurements, as well as with the CTDIvol of patient examinations. METHODS:Data from 50 patients with lung lesions who underwent a CT fluoroscop...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4884231

    authors: Zanca F,Jacobs A,Crijns W,De Wever W

    更新日期:2014-07-01 00:00:00

  • Dose distributions in bifurcated coronary vessels treated with catheter-based photon and beta emitters in intravascular brachytherapy.

    abstract::The dose distributions in the bifurcated vessels treated with intravascular brachytherapyline sources are complicated and depend on the bifurcation geometry consisting of a main and a branch vessel at different angles. To investigate the dosimetric effects at the bifurcation, calculations were performed on branching v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1582813

    authors: Yue N,Roberts KB,Pfau SE,Nath R

    更新日期:2003-07-01 00:00:00

  • A multiple detector array helical x-ray microtomography system for specimen imaging.

    abstract::An x-ray computed microtomography system for specimen and small animal imaging was built and tested. The system used seventeen 48-microm-wide detector arrays (a charge coupled device camera) and helical acquisition techniques. Images were acquired using 540 rays/view and 400 views/2pi. The modulation transfer function...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598662

    authors: Corrigan NM,Chavez AE,Wisner ER,Boone JM

    更新日期:1999-08-01 00:00:00

  • "SABER": A new software tool for radiotherapy treatment plan evaluation.

    abstract:PURPOSE:Both spatial and biological information are necessary in order to perform true optimization of a treatment plan and for predicting clinical outcome. The goal of this work is to develop an enhanced treatment plan evaluation tool which incorporates biological parameters and retains spatial dose information. METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3497152

    authors: Zhao B,Joiner MC,Orton CG,Burmeister J

    更新日期:2010-11-01 00:00:00

  • Monte Carlo calculation of the maximum therapeutic gain of tumor antivascular alpha therapy.

    abstract:PURPOSE:Metastatic melanoma lesions experienced marked regression after systemic targeted alpha therapy in a phase 1 clinical trial. This unexpected response was ascribed to tumor antivascular alpha therapy (TAVAT), in which effective tumor regression is achieved by killing endothelial cells (ECs) in tumor capillaries ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3681010

    authors: Huang CY,Oborn BM,Guatelli S,Allen BJ

    更新日期:2012-03-01 00:00:00

  • Dose-averaged LET calculation for proton track segments using microdosimetric Monte Carlo simulations.

    abstract:PURPOSE:There is an increasing interest in calculating linear energy transfer (LET) distributions for proton therapy treatments in order to assess the influence of this quantity in biological terms. Microdosimetric Monte Carlo (MC) simulations are useful tools to calculate dose-averaged LET, as this has been broadly pr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13643

    authors: Bertolet A,Baratto-Roldán A,Barbieri S,Baiocco G,Carabe A,Cortés-Giraldo MA

    更新日期:2019-09-01 00:00:00

  • Rare-earth scatter fractions in chest radiography.

    abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597041

    authors: Petrone TJ,Steidley KD

    更新日期:1993-03-01 00:00:00

  • Fast technetium-99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry.

    abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13253

    authors: van der Velden S,Dietze MMA,Viergever MA,de Jong HWAM

    更新日期:2019-01-01 00:00:00

  • A chamber and electrometer calibration factor as determined by each of the five AAPM accredited dosimetry calibration laboratories.

    abstract::The same calibration grade ionization chamber and electrometer were sequentially sent to all five currently AAPM Accredited Dosimetry Calibration Laboratories (ADCL). A Cesium-137 based check device was utilized to ensure chamber and electrometer factor constancy and showed a maximum deviation of 0.32% (typically less...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596880

    authors: Blackwell CR,McCullough EC

    更新日期:1992-01-01 00:00:00