Abstract:
:Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-dimensional step function whose shape corresponds to the applicator aperture. Two different approaches to obtain angular spread or the equivalent spatial spread are investigated. In the first method, the pencil beam angular spread is assumed to be Gaussian in shape. The angular spread constants (sigma theta) are then obtained from the slopes of measured intensity profiles. In the second method, the angular spread, in the form of an array of numerical values, is obtained by the deconvolution of measured intensity profiles. After obtaining the angular spread, the calculation for convolution is done in a number of parallel planes normal to the central axis at various distances from the electron collimator. Intensity at any arbitrary point in space is computed by interpolating between intensity distributions in adjacent planes on either side of the point. The effects of variations in angular spread as a function of field size for two treatment machines, one with a scanned electron beam and the other with a scattering foil, have been studied. The consequences of assuming angular spread to be of Gaussian shape are also examined. The electron intensity calculation techniques described in this paper apply primarily to methods of dose calculations that employ pencil beams generated using Monte Carlo simulations.
journal_name
Med Physjournal_title
Medical physicsauthors
Mohan R,Chui CS,Fontenla D,Han K,Ballon Ddoi
10.1118/1.596252subject
Has Abstractpub_date
1988-03-01 00:00:00pages
204-10issue
2eissn
0094-2405issn
2473-4209journal_volume
15pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of irradiation. When acquiring...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1576229
更新日期:2003-06-01 00:00:00
abstract::The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1414008
更新日期:2001-11-01 00:00:00
abstract:PURPOSE:The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with the Linac's log file i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13579
更新日期:2019-07-01 00:00:00
abstract::Our purpose in this paper is to present an in vivo dosimetry program designed both for measuring the rectal dose and for avoiding misadministrations in gynecological intracavitary implants. A device containing an energy compensated diode was specially designed for these measurements. Our calibration procedure as well ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598598
更新日期:1999-05-01 00:00:00
abstract::The intensity of Compton scattered photons is directly proportional to the electron density of a substance; therefore it is possible to detect changes in electron density by this noninvasive method. The source-detector geometry has been varied to study the effects of geometry on the calculated electron density values,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595730
更新日期:1985-01-01 00:00:00
abstract:PURPOSE:Target localization accuracy of cone-beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous re...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4896101
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13195
更新日期:2018-12-01 00:00:00
abstract::To more accurately and precisely delineate a tumor in a 3D PET image, we proposed a novel, semi-automatic, two-stage method by utilizing an adaptive region-growing algorithm and a dual-front active contour model. First, a rough region of interest (ROI) is manually drawn by a radiation oncologist that encloses a tumor....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2956713
更新日期:2008-08-01 00:00:00
abstract::Recent work has shown that there is significant uncertainty in measuring build-up doses in mega-voltage photon beams especially at high energies. In this present investigation we used a phantom-embedded extrapolation chamber (PEEC) made of Solid Water to validate Monte Carlo (MC)-calculated doses in the dose build-up ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1829401
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:Measured values of ultrasound attenuation in bone represent a combination of different loss mechanisms. As a wave is transmitted from a fluid into bone, reflections occur at the interface. In the bone, mode conversion occurs between longitudinal and shear modes and the mechanical wave is scattered by its comple...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3668316
更新日期:2012-01-01 00:00:00
abstract::Optimal visualization of moving structures such as the heart and coronary arteries using digital radiographic imaging systems is a difficult problem that can involve tradeoffs between temporal, spatial, and density resolution. The motion dependence of four angiographic measures of vessel dimensions is given and demons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595651
更新日期:1985-11-01 00:00:00
abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596336
更新日期:1989-09-01 00:00:00
abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598316
更新日期:1998-08-01 00:00:00
abstract:PURPOSE:Stray neutron radiation is of concern after radiation therapy, especially in children, because of the high risk it might carry for secondary cancers. Several previous studies predicted the stray neutron exposure from proton therapy, mostly using Monte Carlo simulations. Promising attempts to develop analytical ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4829512
更新日期:2013-12-01 00:00:00
abstract::Multimodality NIR spectroscopy systems offer the possibility of region-based vascular and molecular characterization of tissue in vivo. However, computationally efficient 3D image reconstruction algorithms specific to these image-guided systems currently do not exist. Image reconstruction is often based on finite-elem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2795832
更新日期:2007-11-01 00:00:00
abstract::Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S val...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3103401
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734878
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The National Council for Radiation Protection and Measurement (NCRP) published estimates for the collective population dose and the mean effective dose to the population of the United States from medical imaging procedures for 1980/1982 and for 2006. The earlier report ignored the effective dose from radiothera...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906190
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antib...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921997
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12477
更新日期:2017-10-01 00:00:00
abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4935141
更新日期:2015-12-01 00:00:00
abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14112
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3397458
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3355933
更新日期:2010-04-01 00:00:00
abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3081414
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These "cold" walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813302
更新日期:2013-08-01 00:00:00
abstract::It is shown that predictions can be made of scatter-to-primary ratios for a variety of mammographic configurations. The different configurations can be produced by changes in source-detector distance; source-phantom distance; air gap; photon energy; phantom composition, thickness, and cross-sectional area. A detailed ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595807
更新日期:1986-11-01 00:00:00
abstract:PURPOSE:Repeated brain MRI scans are performed in many clinical scenarios, such as follow up of patients with tumors and therapy response assessment. In this paper, the authors show an approach to utilize former scans of the patient for the acceleration of repeated MRI scans. METHODS:The proposed approach utilizes the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4928148
更新日期:2015-09-01 00:00:00
abstract::Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1898485
更新日期:2005-06-01 00:00:00
abstract:PURPOSE:The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. METHODS:The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14054
更新日期:2020-04-01 00:00:00