The effects of motion on quantitative vessel measurements.

Abstract:

:Optimal visualization of moving structures such as the heart and coronary arteries using digital radiographic imaging systems is a difficult problem that can involve tradeoffs between temporal, spatial, and density resolution. The motion dependence of four angiographic measures of vessel dimensions is given and demonstrated experimentally. Although the densitometric cross-sectional area is shown to be independent of motion, densitometric thickness (contrast) decreases and the apparent width (distance between edges) and densitometric width both increase with motion. Knowledge of the velocity allows the apparent width but not the densitometric width to be corrected. It is also shown that current limitations which result in tradeoffs between kVp and x-ray pulse duration seriously compromise the advantages of using small focal spots in coronary artery imaging.

journal_name

Med Phys

journal_title

Medical physics

authors

Parker DL,Clayton PD,Gustafson DE

doi

10.1118/1.595651

subject

Has Abstract

pub_date

1985-11-01 00:00:00

pages

698-704

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

12

pub_type

杂志文章
  • Attenuation, scattering, and absorption of ultrasound in the skull bone.

    abstract:PURPOSE:Measured values of ultrasound attenuation in bone represent a combination of different loss mechanisms. As a wave is transmitted from a fluid into bone, reflections occur at the interface. In the bone, mode conversion occurs between longitudinal and shear modes and the mechanical wave is scattered by its comple...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3668316

    authors: Pinton G,Aubry JF,Bossy E,Muller M,Pernot M,Tanter M

    更新日期:2012-01-01 00:00:00

  • Fast technetium-99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry.

    abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13253

    authors: van der Velden S,Dietze MMA,Viergever MA,de Jong HWAM

    更新日期:2019-01-01 00:00:00

  • Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.

    abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13508

    authors: Tho D,Beaulieu L

    更新日期:2019-05-01 00:00:00

  • Film dosimetry analyses on the effect of gold shielding for iodine-125 eye plaque therapy for choroidal melanoma.

    abstract::One of the methods currently being used to treat choroidal melanoma employs an episcleral plaque containing I-125 radioactive seeds. However, comprehensive dosimetry studies on the plaque are scarce and controversial. For this work, we use film to study the dosimetry outside the lip of the gold shield of the eye plaqu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596556

    authors: Wu A,Krasin F

    更新日期:1990-09-01 00:00:00

  • Normalized dose data for upper gastrointestinal tract contrast studies performed to infants.

    abstract::The aim of the current study was to (a) provide normalized dose data for the estimation of the radiation dose from upper gastrointestinal tract contrast (UGIC) studies carried out to infants and (b) estimate the average patient dose and risks associated with radiation from UGIC examinations performed in our institutio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2181297

    authors: Damilakis J,Stratakis J,Raissaki M,Perisinakis K,Kourbetis N,Gourtsoyiannis N

    更新日期:2006-04-01 00:00:00

  • An optimized ultrasound detector for photoacoustic breast tomography.

    abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792462

    authors: Xia W,Piras D,van Hespen JC,van Veldhoven S,Prins C,van Leeuwen TG,Steenbergen W,Manohar S

    更新日期:2013-03-01 00:00:00

  • X-ray diffraction computed tomography.

    abstract::Coherent scattering of x-ray photons leads to the phenomenon of x-ray diffraction, which is widely used for determining atomic structure in materials science. A technique [x-ray diffraction computed tomography (CT)] is described, analogous to conventional CT, in which the x-ray diffraction properties of a stack of two...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596063

    authors: Harding G,Kosanetzky J,Neitzel U

    更新日期:1987-07-01 00:00:00

  • Skeletal dosimetry in cone beam computed tomography.

    abstract::Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3147143

    authors: Walters BR,Ding GX,Kramer R,Kawrakow I

    更新日期:2009-07-01 00:00:00

  • Smoothing intensity-modulated treatment delivery under hardware constraints.

    abstract::A method is developed to smooth intensity-modulated beam delivery while considering hardware constraints. The method uses matrix algebra to model MLC leaf motion and hardware constraints such as interleaf digitization, synchronization requirements, and intersegment field abutment to deliver intensity modulated beam se...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1521121

    authors: Ma L

    更新日期:2002-12-01 00:00:00

  • Direct aperture optimization: a turnkey solution for step-and-shoot IMRT.

    abstract::IMRT treatment plans for step-and-shoot delivery have traditionally been produced through the optimization of intensity distributions (or maps) for each beam angle. The optimization step is followed by the application of a leaf-sequencing algorithm that translates each intensity map into a set of deliverable aperture ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477415

    authors: Shepard DM,Earl MA,Li XA,Naqvi S,Yu C

    更新日期:2002-06-01 00:00:00

  • A thermoregulated enclosure for controlling thermal drift in a radiation calorimeter.

    abstract::The ability to control thermal drifts is essential in operating a calorimeter. We investigated a thermal enclosure, which envelops the calorimeter with temperature-regulated air, thus thermally isolating the calorimeter from the room. The desired temperature in the enclosure is controlled by a control circuit and a th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595760

    authors: Kubo H,Brown DE,Russell MD

    更新日期:1985-05-01 00:00:00

  • Spectrally resolved bioluminescence tomography using the reciprocity approach.

    abstract::Spectrally resolved bioluminescence optical tomography is an approach to recover images of, for example, Luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminesc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982138

    authors: Dehghani H,Davis SC,Pogue BW

    更新日期:2008-11-01 00:00:00

  • Rapid in vivo localization of a lost brachytherapy seed.

    abstract::We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595528

    authors: Woolfenden JM,Barber HB,Oleson JR,Wild WJ

    更新日期:1984-07-01 00:00:00

  • A scintillator-based approach to monitor secondary neutron production during proton therapy.

    abstract:PURPOSE:The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4963813

    authors: Clarke SD,Pryser E,Wieger BM,Pozzi SA,Haelg RA,Bashkirov VA,Schulte RW

    更新日期:2016-11-01 00:00:00

  • Joint model of motion and anatomy for PET image reconstruction.

    abstract::Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respirato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2804721

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi O

    更新日期:2007-12-01 00:00:00

  • Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

    abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3002314

    authors: Wronski MM,Rowlands JA

    更新日期:2008-12-01 00:00:00

  • MR acoustic radiation force imaging: in vivo comparison to ultrasound motion tracking.

    abstract::MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3120289

    authors: Huang Y,Curiel L,Kukic A,Plewes DB,Chopra R,Hynynen K

    更新日期:2009-06-01 00:00:00

  • Geometry optimization of electrically floating PET inserts for improved RF penetration for a 3 T MRI system.

    abstract:PURPOSE:An electrically floating radio frequency (RF) shielded PET insert with individual PET detectors shielded by separate Faraday cages enables the MRI built-in body RF coil to be used at least as an RF transmitter, in which the RF field penetrates the imaging region inside the PET ring through the narrow gaps betwe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13132

    authors: Akram MSH,Levin CS,Obata T,Hirumi G,Yamaya T

    更新日期:2018-10-01 00:00:00

  • Using FDG-PET activity as a surrogate for tumor cell density and its effect on equivalent uniform dose calculation.

    abstract::The concept of equivalent uniform dose (EUD) has been suggested as a means to quantitatively consider heterogeneous dose distributions within targets. Tumor cell density/function is typically assumed to be uniform. We herein propose to use 18F-labeled 2-deoxyglucose (FDG) positron emission tomography (PET) tumor imagi...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1779372

    authors: Zhou SM,Wong TZ,Marks LB

    更新日期:2004-09-01 00:00:00

  • Experimental verification of EGSnrc Monte Carlo calculated depth doses within a realistic parallel magnetic field in a polystyrene phantom.

    abstract:PURPOSE:Integrating a linac with a magnetic resonance imager (MRI) will revolutionize the accuracy of external beam radiation treatments. Irradiating in the presence of a strong magnetic field, however, will modify the dose distribution. These dose modifications have been investigated previously, mainly using Monte Car...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12413

    authors: Ghila A,Steciw S,Fallone BG,Rathee S

    更新日期:2017-09-01 00:00:00

  • SU-D-218-05: Material Quantification in Spectral X-Ray Imaging: Optimization and Validation.

    abstract:PURPOSE:To develop and validate a multivariate statistical method to optimize scanning parameters for material quantification in spectral x-rayimaging. METHODS:An optimization metric was constructed by extensively sampling the thickness space for the expected number of counts for m (two or three) materials. This resul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734708

    authors: Nik SJ,Thing RS,Watts R,Meyer J

    更新日期:2012-06-01 00:00:00

  • SU-D-BRA-02: An Extended Time-Variant Seasonal Autoregressive Model-Based Prediction for Irregular Breathing Motion Tracking.

    abstract:PURPOSE:Real-time tumor position/shape measurement and dynamic beam tracking techniques allow accurate and continuous irradiation to moving tumor, but there can be a delay of several hundred milliseconds between observation and irradiation. A time-variant seasonal autoregressive (TVSAR) model has been proposed for comp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734680

    authors: Ichiji K,Homma N,Sakai M,Narita Y,Takai Y,Yoshizawa M

    更新日期:2012-06-01 00:00:00

  • Calculation of photon dose distributions in an inhomogeneous medium using convolutions.

    abstract::A formulation of the single energy photon transport problem is cast in the form of a series of convolutions over the primary fluence distribution with invariant kernels. A method is developed for compensating for the variant intervoxel attenuation in the scattered dose distribution by means of an invariant correction ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595964

    authors: Boyer AL,Mok EC

    更新日期:1986-07-01 00:00:00

  • Combined use of transverse and scout computed tomography scans to localize radioactive seeds in an interstitial brachytherapy implant.

    abstract::Various techniques have been developed to localize radioactive sources in brachytherapy implants. The most common methods include the orthogonal film method, the stereo-shift film method, and recently, direct localization from a series of contiguous CT transverse images. The major advantage of the CT method is that it...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598548

    authors: Yue N,Chen Z,Bond JE,Son YH,Nath R

    更新日期:1999-04-01 00:00:00

  • Comparison of measured and estimated maximum skin doses during CT fluoroscopy lung biopsies.

    abstract:PURPOSE:To measure patient-specific maximum skin dose (MSD) associated with CT fluoroscopy (CTF) lung biopsies and to compare measured MSD with the MSD estimated from phantom measurements, as well as with the CTDIvol of patient examinations. METHODS:Data from 50 patients with lung lesions who underwent a CT fluoroscop...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4884231

    authors: Zanca F,Jacobs A,Crijns W,De Wever W

    更新日期:2014-07-01 00:00:00

  • An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan.

    abstract:PURPOSE:Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754797

    authors: Lewis D,Micke A,Yu X,Chan MF

    更新日期:2012-10-01 00:00:00

  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • On the constancy in composition of polystyrene and polymethylmethacrylate plastics.

    abstract::Variations in the atomic composition, and mass and electron densities of polystyrene and polymethylmethacrylate (PMM) plastics were assessed from experimentally determined mass attenuation coefficients for 125I and 137Cs gamma rays. The means and standard deviations in the mass densities of 16 samples of PMM and 10 sa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594528

    authors: Schulz RJ,Nath R

    更新日期:1979-03-01 00:00:00

  • Efficient low-dose CT artifact mitigation using an artifact-matched prior scan.

    abstract:PURPOSE:Low-dose CT has attracted increasing attention due to growing concerns about radiation exposure in medical scans. However, the frugal use of x-ray radiation inevitably reduces the quality of the CT images, introducing artifacts such as noise and streaks which make the reconstructed images difficult to read in c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736528

    authors: Xu W,Mueller K

    更新日期:2012-08-01 00:00:00

  • SU-E-T-213: Development of a Web Wrapper to Facilitate Radiotherapy Research.

    abstract:PURPOSE:Researchers write many computer programs with unique implementations, usually requiring a great amount of effort for other researchers to learn how to install, configure, and use. Some programs require specialized hardware platforms such as GPU workstation or CPU cluster, which may not readily available for man...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735274

    authors: Folkerts M,Graves Y,Gautier Q,Kim G,Jia X,Jiang S

    更新日期:2012-06-01 00:00:00