Abstract:
:Various techniques have been developed to localize radioactive sources in brachytherapy implants. The most common methods include the orthogonal film method, the stereo-shift film method, and recently, direct localization from a series of contiguous CT transverse images. The major advantage of the CT method is that it provides the seed locations relative to anatomic structures. However, it is often the case that accurate identification and localization of the sources become difficult because of partial source artifacts in more than one transverse cut and other artifacts on CT images. A new algorithm has been developed to combine the advantages of using a pair of orthogonal scout views with the advantages of using a stack of transverse cuts. In the new algorithm, a common reference point is used to correlate CT transverse images and two orthogonal scout CT scans (AP and lateral). The radioactive sources are localized on CT transverse images. At the same time, the sources are displayed automatically on the two CT scout scans. In this way, the individual sources can be clearly distinguished and ambiguities arising from partial source artifacts are resolved immediately. Because of the finite slice thickness of transverse cuts, the longitudinal coordinates are more accurately obtained from the scout views. Therefore, the longitudinal coordinates of seeds localized on the transverse cuts are adjusted so that they match the position of the seeds on scout views. The algorithm has been tested on clinical cases and has proved to be a time saving and accurate method.
journal_name
Med Physjournal_title
Medical physicsauthors
Yue N,Chen Z,Bond JE,Son YH,Nath Rdoi
10.1118/1.598548subject
Has Abstractpub_date
1999-04-01 00:00:00pages
502-5issue
4eissn
0094-2405issn
2473-4209journal_volume
26pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2794175
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length repres...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734756
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To use machine-learning algorithms and blur measure (BM) operators to automatically detect motion blur in mammograms. Motion blur has been reported to reduce lesion detection performance and mask small abnormalities, resulting in failure to detect them until they reach more advanced stages. Automatic detection ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14069
更新日期:2020-04-01 00:00:00
abstract::Noise, partial volume (PV) effect, and image-intensity inhomogeneity render a challenging task for segmentation of brain magnetic resonance (MR) images. Most of the current MR image segmentation methods focus on only one or two of the above-mentioned effects. The objective of this paper is to propose a unified framewo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1944912
更新日期:2005-07-01 00:00:00
abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740095
更新日期:2012-07-01 00:00:00
abstract::The wall of an ionization chamber is commonly assumed to have a negligible effect on chamber response in electron beams. For cylindrical chambers with thin walls this assumption is valid. However, parallel-plate chambers commonly possess large mechanical supports which may affect chamber response in a manner not accou...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596165
更新日期:1988-01-01 00:00:00
abstract:PURPOSE:Colon cancer is a major public health problem due to its high disease rate and death toll worldwide. The use of FTIR microscopy in the field of cancer diagnosis has become attractive over the past 20 years. In the present study, the authors investigated the potential of FTIR microscopy to define spectral change...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3298013
更新日期:2010-03-01 00:00:00
abstract::We designed a novel force/torque moment transducer with six degrees of freedom. This new sensor is used for measuring the forces and torque moments exerted by static magnetic resonance imaging (MRI) fields on various medical implants, instruments, and ballistic shell fragments. To determine the location of strongest e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597853
更新日期:1996-06-01 00:00:00
abstract::An important aspect of heavy charged particle radiotherapy is its ability to localize dose to the target volume. Current techniques generally employ beam delivery schemes which use range modulated beams in which the Bragg peak is spread out over a range of depths. The range modulation is constant over the entire beam ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595419
更新日期:1983-11-01 00:00:00
abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12742
更新日期:2018-03-01 00:00:00
abstract::The authors present an alternative approach to inverse planning optimization and apply it to volumetric modulated are therapy (VMAT) in one rotation with a prior knowledge about the type of leaf motions. The optimization is based on the projection theorem in inner product spaces. MLC motion is directly considered in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3173815
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:Dual-energy computed tomography and dual-energy cone-beam computed tomography (DE-CBCT) are promising modalities for applications ranging from vascular to breast, renal, hepatic, and musculoskeletal imaging. Accordingly, the optimization of imaging techniques for such applications would benefit significantly fr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736420
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12459
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and elec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4820361
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:This study aims to investigate the feasibility of using the images of the treatment fields acquired by an electronic portal imaging device (EPID) for real-time target localization. METHODS:Forty one patients treated with IMRT and RapidArc were recruited in this study including 37 prostate patients and 4 lung p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734975
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:This study aimed to introduce heat map, a graphical data presentation method widely used in gene expression experiments, to the presentation and interpretation of image fidelity assessment data of compressed computed tomography (CT) images. METHODS:The authors used actual assessment data that consisted of five...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3611046
更新日期:2011-08-01 00:00:00
abstract::The accurate calculation of the skeleton of an object is a problem not satisfactorily solved by existing approaches. Most algorithms require a significant amount of user interaction and use a voxel grid to compute discrete and often coarse approximations of this representation of the data. We present a novel, automati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2409238
更新日期:2007-02-01 00:00:00
abstract:PURPOSE:In recent years, laser-based acceleration of charged particles has rapidly progressed and medical applications, e.g., in radiotherapy, might become feasible in the coming decade. Requirements are monoenergetic particle beams with long-term stable and reproducible properties as well as sufficient particle intens...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3301598
更新日期:2010-04-01 00:00:00
abstract:PURPOSE:To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. METHODS:The authors show that by taking an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4859295
更新日期:2014-02-01 00:00:00
abstract::Machine outputs, peak scatter factors, and central axis percentage depth dose distributions were measured for various phantom sizes in large radiation fields produced at extended distances by cobalt, 6-MV, and 10-MV photon beams. The results can be applied to practical total body irradiation procedures which usually i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595686
更新日期:1985-09-01 00:00:00
abstract::A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1413519
更新日期:2001-12-01 00:00:00
abstract::We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2828184
更新日期:2008-02-01 00:00:00
abstract::This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1386424
更新日期:2001-09-01 00:00:00
abstract:PURPOSE:Task Group 119 (TG-119) has been adopted for evaluating the adequacy of intensity-modulated radiation therapy (IMRT) commissioning and for establishing patient-specific IMRT quality assurance (QA) passing criteria in clinical practice. TG-119 establishes 95% confidence limits (CLs), which help clinics identify ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12759
更新日期:2018-03-01 00:00:00
abstract::We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595528
更新日期:1984-07-01 00:00:00
abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734893
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. How...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3697524
更新日期:2012-04-01 00:00:00
abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2936229
更新日期:2008-07-01 00:00:00
abstract::We describe the use of a graphical mathematical spreadsheet programming environment which can be used to simulate the acquisition and reconstruction processes of an x-ray computed tomography (CT) machine. The simulation is used to study the effect of photon counting statistics on the noise in the reconstructed image. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598654
更新日期:1999-08-01 00:00:00
abstract:PURPOSE:To investigate the critical structure sparing achievable by biological optimization for modulated volumetric arc (VMAT) of head and neck (H&N) cancer. METHODS:Ten H&N VMAT patients who were originally planned and treated with simultaneous integrated boost technique using dose-volume based optimization, were se...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735671
更新日期:2012-06-01 00:00:00