Abstract:
:This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an accurate calculation technique for determining absorbed dose distributions for the purpose of BNCT treatment planning. For a four-group, one-dimensional calculation in water, this method was used to determine values for the neutron scattering cross sections, neutron removal cross sections, neutron diffusion coefficients, and extrapolation distances. These values were then used in a one-dimensional DIF3D calculation. The results of the DIF3D calculation showed a maximum deviation of 2.5% from a MCNP calculation performed for the same geometry.
journal_name
Med Physjournal_title
Medical physicsauthors
Albertson BJ,Blue TE,Niemkiewicz Jdoi
10.1118/1.1386424subject
Has Abstractpub_date
2001-09-01 00:00:00pages
1898-904issue
9eissn
0094-2405issn
2473-4209journal_volume
28pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13731
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:Osteoporosis is a common bone disease associated with increased risk of low-trauma fractures leading to substantial morbidity, mortality, and financial costs. Clinically, osteoporosis is defined by low bone mineral density (BMD); however, increasing evidence suggests that trabecular bone (TB) microarchitectural...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4928481
更新日期:2015-09-01 00:00:00
abstract::In the last 30 years, thousands of basic or clinical studies have been devoted to atherosclerosis or to the problem of restenosis after angioplasty. In these studies, axial stresses in the vessel wall have received practically no attention, contrary to circumferential stress and purely biological aspects. Based on a r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1844432
更新日期:2005-02-01 00:00:00
abstract::Single photon emission computed tomography (SPECT) is an important technology for molecular imaging studies of small animals. In this arena, there is an increasing demand for high performance imaging systems that offer improved spatial resolution and detection efficiency. We have designed a multipinhole small animal i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2190332
更新日期:2006-05-01 00:00:00
abstract:PURPOSE:Water equivalent diameter (WED) is the preferred surrogate for patient size in CT. It is better than geometric size surrogates and patient weight/height/BMI/age because it correlates the best with x-ray attenuation. The administration of oral/IV contrast agents increases a patient's attenuation and should there...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14721
更新日期:2021-01-13 00:00:00
abstract:PURPOSE:The quality of a treatment plan for stereotactic body radiotherapy (SBRT) depends on an experience of each treatment planner. Therefore, the treatment plans are subjectively determined by comparison of several treatment plans developed by time consuming iterative manners, while considering the benefit to a tumo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735950
更新日期:2012-06-01 00:00:00
abstract::An electronic scanning-slit technology is under development which involves replacing paired fore and aft slits for scatter rejection with only one fore slit. As the slit scans across the portion of the patient to be imaged, pulsed x-ray exposures produce images of the slit in successive positions, which are digitized ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595940
更新日期:1986-03-01 00:00:00
abstract:PURPOSE:Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In thi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4876297
更新日期:2014-06-01 00:00:00
abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594283
更新日期:1976-07-01 00:00:00
abstract::A number of relocatable head fixation systems have become commercially available or developed in-house to perform fractionated stereotactic radiotherapy (SRT) treatment. The uncertainty usually quoted for the target repositioning in SRT is over 2 mm, more than twice that of stereotactic radiosurgery (SRS) systems. Thi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598930
更新日期:2000-04-01 00:00:00
abstract::Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1469627
更新日期:2002-05-01 00:00:00
abstract::The trend toward conformal techniques in stereotactic radiosurgery necessitates an accurate and practical method for verification of irregular three-dimensional dose distributions. This work presents the design and evaluation of a phantom system facilitating the measurement of conformal dose distributions using one or...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598962
更新日期:2000-05-01 00:00:00
abstract:PURPOSE:Currently, in clinical practice of intensity-modulated proton therapy (IMPT), the influence of the minimum monitor unit (MU) constraint is taken into account through postprocessing after the optimization is completed. This may degrade the plan quality and plan robustness. This study aims to mitigate the impact ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12677
更新日期:2018-01-01 00:00:00
abstract::For the case of eye tumor therapy with protons, improvements are introduced compared to the standard dose calculation which implies straight-line optics and the constant-density assumption for the eye and its surrounding. The progress consists of (i) taking account of the lateral scattering of the protons in tissue by...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2168067
更新日期:2006-03-01 00:00:00
abstract::A method is described for obtaining S values between a tumor and its host organ for use with the MIRD formalism. It applies the point-source specific absorbed fractions for an infinite water medium, tabulated by Berger, to a rectangular solid of arbitrary dimensions which contains a rectangular tumor of arbitrary dime...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596732
更新日期:1991-05-01 00:00:00
abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3447726
更新日期:2010-07-01 00:00:00
abstract::A suitable was phantom was designed for evaluating various film techniques used in subtraction radiography. Holes are drilled in a slab of wax and filled with various concentrations of iodinated wax, producing disk-shaped regions with diffuse borders. The technical details of construction and a representative applicat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594371
更新日期:1977-05-01 00:00:00
abstract:PURPOSE:An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as(99m)Tc or most positron emission tomography radiopharmaceuticals. METHODS:By evaluation of the resul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4884035
更新日期:2014-07-01 00:00:00
abstract::In this study, BrachyDose, a recently developed EGSnrc Monte Carlo code for rapid brachytherapy dose calculations, has been benchmarked by reproducing previously published dosimetry parameters for three brachytherapy seeds with varied internal structure and encapsulation. Calculations are performed for two 125I seeds ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2400843
更新日期:2007-02-01 00:00:00
abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792636
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is prefer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13958
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4964454
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14696
更新日期:2020-12-31 00:00:00
abstract:PURPOSE:The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammograp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4837220
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:To develop an accurate and efficient single-marker-based optical tracking system to enhance patient safety and quality of care in radiotherapy. METHODS:The optical tracking system consists of a Polaris camera as well as in-house software. The camera is mounted inside the treatment room and detects the location...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735240
更新日期:2012-06-01 00:00:00
abstract::Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1835571
更新日期:2005-01-01 00:00:00
abstract::The commonly used Blunck and Leisegang electron energy-loss distribution falls off too rapidly with increasing energy loss. Also, for large thicknesses and/or low-Z media, where their distribution should approach Landau's, it normalizes to 0.92 rather than 1.0, it overestimates the number of very small energy-loss eve...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595500
更新日期:1984-05-01 00:00:00
abstract::Manganese (Mn) is an essential nutrient for growth and development. Unfortunately, overexposure can lead to neurological damage, which is manifested as a movement disorder marked by tremors. Preclinical symptoms have been found in populations occupationally exposed to the element, and it is suggested that in late stag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1517613
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:The collimator monitoring fill factor (CM-FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM-FF) introduced by Gago-Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D-arrays. The error detection capabilities of 2D-arrays were studied by co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13417
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:Discuss optimised Accelerated Partial Breast Irradiation (APBI) using a Strut-Adjused Volume Implant (SAVI) applicator for patients with implanted pacemeker, without overdosing or relocating the pacemaker. METHODS:A right breast cancer patient with an in situ pacemaker (Medtronic model ADDR01) on the right sid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735299
更新日期:2012-06-01 00:00:00