Abstract:
:A suitable was phantom was designed for evaluating various film techniques used in subtraction radiography. Holes are drilled in a slab of wax and filled with various concentrations of iodinated wax, producing disk-shaped regions with diffuse borders. The technical details of construction and a representative application are described.
journal_name
Med Physjournal_title
Medical physicsauthors
Ort MG,Gregg ECdoi
10.1118/1.594371subject
Has Abstractpub_date
1977-05-01 00:00:00pages
232-4issue
3eissn
0094-2405issn
2473-4209journal_volume
4pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4817482
更新日期:2013-09-01 00:00:00
abstract::We have performed a comprehensive dosimetric characterization of the Oncura model 6711 125I seed using both experimental [LiF thermoluminscent dosimetry (TLD)] and theoretical (Monte Carlo photon transport) methods. In addition to determining the dosimetric parameters of the 6711, this report quantified: (1) the angul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2388158
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:A compact, three-tesla magnetic resonance imaging (MRI) system has been developed. It features a 37 cm patient aperture, allowing the use of commercial receiver coils. Its design allows simultaneously for gradient amplitudes of 85 millitesla per meter (mT/m) sustained and 700 tesla per meter per second (T/m/s) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941362
更新日期:2016-03-01 00:00:00
abstract::Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S val...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3103401
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13975
更新日期:2020-03-01 00:00:00
abstract::We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2828184
更新日期:2008-02-01 00:00:00
abstract::The trend toward conformal techniques in stereotactic radiosurgery necessitates an accurate and practical method for verification of irregular three-dimensional dose distributions. This work presents the design and evaluation of a phantom system facilitating the measurement of conformal dose distributions using one or...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598962
更新日期:2000-05-01 00:00:00
abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598459
更新日期:1998-12-01 00:00:00
abstract::A new rubber band straightening transform (RBST) is introduced for characterization of mammographic masses as malignant or benign. The RBST transforms a band of pixels surrounding a segmented mass onto the Cartesian plane (the RBST image). The border of a mammographic mass appears approximately as a horizontal line, a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598228
更新日期:1998-04-01 00:00:00
abstract::Two recently developed A 150 plastic-equivalent gas mixtures have been tested for suitability in proportional counter applications. Methane- and propane-based "tissue-equivalent" gases were also included for comparison purposes. Event-size weighted dose distributions were measured in a 14.8-MeV neutron beam. Resolutio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595536
更新日期:1984-07-01 00:00:00
abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595642
更新日期:1984-09-01 00:00:00
abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13508
更新日期:2019-05-01 00:00:00
abstract::Like Medical Physics, Imaging Informatics encompasses concepts touching every aspect of the imaging chain from image creation, acquisition, management and archival, to image processing, analysis, display and interpretation. The two disciplines are in fact quite complementary, with similar goals to improve the quality ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735777
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4881096
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:Accurate deformable image registration is necessary for longitudinal studies. The error associated with commercial systems has been evaluated using computed tomography (CT). Several in-house algorithms have been evaluated for use with magnetic resonance imaging (MRI), but there is still relatively little inform...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12406
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:Currently, in clinical practice of intensity-modulated proton therapy (IMPT), the influence of the minimum monitor unit (MU) constraint is taken into account through postprocessing after the optimization is completed. This may degrade the plan quality and plan robustness. This study aims to mitigate the impact ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12677
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:To develop and evaluate the impact on lesion conspicuity of a software-based x-ray scatter correction algorithm for digital breast tomosynthesis (DBT) imaging into which a precomputed library of x-ray scatter maps is incorporated. METHODS:A previously developed model of compressed breast shapes undergoing mamm...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4866229
更新日期:2014-03-01 00:00:00
abstract::Radiation sensitive gels have been used as dosimeters for clinical dose verification of different radiation therapy modalities. However, the use of gels is not widespread, because careful techniques are required to achieve the dose precision and accuracy aimed for in clinical dose verification. Here, the introduction ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2712042
更新日期:2007-04-01 00:00:00
abstract:PURPOSE:To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS:We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735200
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Power spectral analysis in radiographic images is conventionally performed using a windowed overlapping averaging periodogram. This study describes an alternative approach using a multitaper technique and compares its performance with that of the standard method. This tool will be valuable in power spectrum est...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3676740
更新日期:2012-02-01 00:00:00
abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3097633
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:The presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy tissue sparing, particularly for techniques like pencil beam scanning proton therapy which have dynamic delivery systems. While tools exist to estimate this ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13182
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. METHODS:In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4719962
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The purpose of this study was to quantitatively characterize the fundamental aspects of image quality (IQ) associated with different computed tomography (CT) reconstruction algorithms, the resolution, noise texture, noise magnitude per dose, and use those data to devise a methodology to match IQ between differe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12554
更新日期:2017-11-01 00:00:00
abstract::A Monte Carlo computer study of the total dose distribution from neutrons and prompt gamma emissions (but excluding the contribution from conversion and Auger electrons) for gadolinium neutron capture therapy of brain tumors has been carried out in order to test the theoretic feasibility of this modality using commerc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596761
更新日期:1992-09-01 00:00:00
abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3633941
更新日期:2011-10-01 00:00:00
abstract:BACKGROUND AND PURPOSE:Differential baseline shifts between primary tumor and involved lymph nodes in locally advanced lung cancer patients compromise the accuracy of radiotherapy. The purpose of this study was to evaluate the performance of an average anatomy model (AAM) derived from repeat imaging and deformable regi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12271
更新日期:2017-07-01 00:00:00
abstract::Single photon emission computed tomography (SPECT) was investigated for imaging on-board radiation therapy machines in order to localize functional and molecular targets. A computer-simulated female NCAT phantom was positioned supine on a flat-top treatment couch. Twenty tumor locations were defined in the upper torso...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3113902
更新日期:2009-05-01 00:00:00
abstract::The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue whi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595768
更新日期:1985-05-01 00:00:00
abstract:PURPOSE:To describe and mathematically validate the superiorization methodology, which is a recently developed heuristic approach to optimization, and to discuss its applicability to medical physics problem formulations that specify the desired solution (of physically given or otherwise obtained constraints) by an opti...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4745566
更新日期:2012-09-01 00:00:00