Dental enamel as an in vivo radiation dosimeter.

Abstract:

:The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue which retains indefinitely its radiation history, and electron spin resonance measurements have shown that the radiation signal can be resolved down to about 10 cGy. Measurements on samples from the general population give radiation exposure estimates that are reasonable, and one measurement on a patient who had radiotherapy to the mouth area showed a good correlation with tumor dose. We believe that this is an important new indicator of radiation dose and taken together with exposure histories should provide important data for epidemiological studies as well as accidental exposures.

journal_name

Med Phys

journal_title

Medical physics

authors

Pass B,Aldrich JE

doi

10.1118/1.595768

subject

Has Abstract

pub_date

1985-05-01 00:00:00

pages

305-7

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

12

pub_type

杂志文章
  • Dosimetric characterization of Ir-192 LDR elongated sources.

    abstract::Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2839102

    authors: van der Laarse R,Granero D,Pérez-Calatayud J,Meigooni AS,Ballester F

    更新日期:2008-03-01 00:00:00

  • Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.

    abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4957389

    authors: So A,Imai Y,Nett B,Jackson J,Nett L,Hsieh J,Wisenberg G,Teefy P,Yadegari A,Islam A,Lee TY

    更新日期:2016-08-01 00:00:00

  • A convolution method for constructing primary beam profiles in the presence of beam modifiers.

    abstract::Empirical functions that describe primary beam profiles for radiotherapy treatment planning systems generally account for finite source size only on beams unmodified by blocks, wedges, or compensating filters. To incorporate the effects of extended sources on such modified beams and to treat the effect of an extended ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596222

    authors: Starkschall G

    更新日期:1988-09-01 00:00:00

  • Implementation of a three-dimensional compensation system based on computed tomography generated surface contours and tissue inhomogeneities.

    abstract::A computed tomography (CT) based system that compensates for patient surface contour and internal tissue inhomogeneity was implemented in our clinic. The compensators are fabricated with a mixture of tin granules and bee's wax. The tin/wax mixture was optimized for tin granule size and tin granule to wax ratio. The na...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597303

    authors: Jursinic PA,Podgorsak MB,Paliwal BR

    更新日期:1994-03-01 00:00:00

  • A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods.

    abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3483784

    authors: Kesner AL,Kuntner C

    更新日期:2010-10-01 00:00:00

  • Monte Carlo dose calculations in homogeneous media and at interfaces: a comparison between GEPTS, EGSnrc, MCNP, and measurements.

    abstract::Three Monte Carlo photon/electron transport codes (GEPTS, EGSnrc, and MCNP) are bench-marked against dose measurements in homogeneous (both low- and high-Z) media as well as at interfaces. A brief overview on physical models used by each code for photon and electron (positron) transport is given. Absolute calorimetric...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1473134

    authors: Chibani O,Li XA

    更新日期:2002-05-01 00:00:00

  • False-positive reduction in CAD mass detection using a competitive classification strategy.

    abstract::High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344203

    authors: Li L,Zheng Y,Zhang L,Clark RA

    更新日期:2001-02-01 00:00:00

  • Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model.

    abstract::The widespread application of positron emission tomography (PET) in clinical oncology has driven this imaging technology into a number of new research and clinical arenas. Increasing numbers of patient scans have led to an urgent need for efficient data handling and the development of new image analysis techniques to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2432404

    authors: Montgomery DW,Amira A,Zaidi H

    更新日期:2007-02-01 00:00:00

  • SU-E-T-231: Comparison of Beam Characteristics of Small Field 6 MeV Electrons as Replacement for Superficial X Ray Beam.

    abstract:PURPOSE:To compare beam characteristics of superficial X-rays with 6 MeV Electrons for the purpose of replacing superficial treatments with electron fields for skin lesions. METHODS:Electron beam cutouts were made with 12mm thickness cerrobend in diameters 2-5 cm to match superficial X-ray machine cones. Central axis ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735294

    authors: Avadhani J,Sasidharan S,Carton C,Lowen M,Klapproth T,Licitra C

    更新日期:2012-06-01 00:00:00

  • Incorporation of treatment plan spatial and temporal dose patterns into a prostate intrafractional motion management strategy.

    abstract:PURPOSE:Periodic MV∕KV radiographs taken during volumetric modulated arc therapy (VMAT) for hypofractionated treatment provide guidance in intrafractional motion management. The choice of imaging frequency and timing are key components in delivering the desired dose while reducing associated overhead such as imaging do...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4742846

    authors: Zhang P,Hunt M,Happersett L,Cox B,Mageras G

    更新日期:2012-09-01 00:00:00

  • Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography.

    abstract:PURPOSE:Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-C...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3658738

    authors: Nowak T,Hupfer M,Brauweiler R,Eisa F,Kalender WA

    更新日期:2011-12-01 00:00:00

  • Technical note: a fast laser-based optical-CT scanner for three-dimensional radiation dosimetry.

    abstract:PURPOSE:To introduce a novel laser-based optical-CT scanner for the readout of three-dimensional (3D) radiation dosimeters. METHODS:The scanner employs a diode laser, a cylindrical lens, a motorized linear rail, a rotation stage, and a charge-coupled device camera. The scanner operates in a translate-rotate fashion an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3538924

    authors: Papadakis AE,Maris TG,Zacharakis G,Papoutsaki V,Varveris C,Ripoll J,Damilakis J

    更新日期:2011-02-01 00:00:00

  • Computer-aided mass detection in mammography: false positive reduction via gray-scale invariant ranklet texture features.

    abstract::In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3049588

    authors: Masotti M,Lanconelli N,Campanini R

    更新日期:2009-02-01 00:00:00

  • A comparison of gantry-mounted x-ray-based real-time target tracking methods.

    abstract:PURPOSE:Most modern radiotherapy machines are built with a 2D kV imaging system. Combining this imaging system with a 2D-3D inference method would allow for a ready-made option for real-time 3D tumor tracking. This work investigates and compares the accuracy of four existing 2D-3D inference methods using both motion tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12765

    authors: Montanaro T,Nguyen DT,Keall PJ,Booth J,Caillet V,Eade T,Haddad C,Shieh CC

    更新日期:2018-03-01 00:00:00

  • The spatial resolution in dosimetry with normoxic polymer-gels investigated with the dose modulation transfer approach.

    abstract::The verification of dose distributions with high dose gradients as appearing in brachytherapy or stereotactic radiotherapy for example, calls for dosimetric methods with sufficiently high spatial resolution. Polymer gels in combination with a MR or optical scanner as a readout device have the potential of performing t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2898173

    authors: Bayreder C,Schön R,Wieland M,Georg D,Moser E,Berg A

    更新日期:2008-05-01 00:00:00

  • Rapid in vivo localization of a lost brachytherapy seed.

    abstract::We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595528

    authors: Woolfenden JM,Barber HB,Oleson JR,Wild WJ

    更新日期:1984-07-01 00:00:00

  • WE-G-217BCD-10: Shading Correction in Image Domain for Cone-Beam CT Without Prior Information.

    abstract:PURPOSE:Cone-beam CT (CBCT) images contain severe shading artifacts mostly due to scatter. Many algorithms have been proposed to alleviate this problem by data correction on projections. Sophisticated methods have also been designed to further improve the image quality when prior patient information is available. In th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736218

    authors: Fan Q,Niu T,Zhu L

    更新日期:2012-06-01 00:00:00

  • Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system.

    abstract:PURPOSE:The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. METHODS:They equipped a research Siemens Artiste linear a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3665712

    authors: Fast MF,Krauss A,Oelfke U,Nill S

    更新日期:2012-01-01 00:00:00

  • Respiratory phase alignment improves blood-flow quantification in Rb82 PET myocardial perfusion imaging.

    abstract:PURPOSE:Positron emission tomography (PET) is considered the gold standard for measuring myocardial blood flow in vivo but it is known that respiratory motion can lead to misalignment of the PET and computed tomography (CT) data sets and introduce artifacts in the CT-based attenuation correction (AC) of images. In addi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4788669

    authors: Pourmoghaddas A,Klein R,deKemp RA,Wells RG

    更新日期:2013-02-01 00:00:00

  • Optimized knot placement for B-splines in deformable image registration.

    abstract:PURPOSE:To develop an automatic knot placement algorithm to enable the use of NonUniform Rational B-Splines (NURBS) in deformable image registration. METHODS:The authors developed a two-step approach to fit a known displacement vector field (DVF). An initial fit was made with uniform knot spacing. The error generated ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3609416

    authors: Jacobson TJ,Murphy MJ

    更新日期:2011-08-01 00:00:00

  • Quantitative CT of lung nodules: dependence of calibration on patient body size, anatomic region, and calibration nodule size for single- and dual-energy techniques.

    abstract::Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148536

    authors: Goodsitt MM,Chan HP,Way TW,Schipper MJ,Larson SC,Christodoulou EG

    更新日期:2009-07-01 00:00:00

  • SU-D-BRA-02: An Extended Time-Variant Seasonal Autoregressive Model-Based Prediction for Irregular Breathing Motion Tracking.

    abstract:PURPOSE:Real-time tumor position/shape measurement and dynamic beam tracking techniques allow accurate and continuous irradiation to moving tumor, but there can be a delay of several hundred milliseconds between observation and irradiation. A time-variant seasonal autoregressive (TVSAR) model has been proposed for comp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734680

    authors: Ichiji K,Homma N,Sakai M,Narita Y,Takai Y,Yoshizawa M

    更新日期:2012-06-01 00:00:00

  • Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study.

    abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4747342

    authors: Sieren JP,Newell JD,Judy PF,Lynch DA,Chan KS,Guo J,Hoffman EA

    更新日期:2012-09-01 00:00:00

  • Characterization of mesothelioma and tissues present in contrast-enhanced thoracic CT scans.

    abstract:PURPOSE:The purpose of this study was to characterize the Hounsfield unit (HU) distributions of mesothelioma and other tissues present in contrast-enhanced thoracic CT scans, to compare the HU distributions of mesothelioma, muscle, and liver by scanner and reconstruction filter/kernel combination, and to assess interpa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3537610

    authors: Corson N,Sensakovic WF,Straus C,Starkey A,Armato SG 3rd

    更新日期:2011-02-01 00:00:00

  • Design of a focused collimator for proton therapy spot scanning using Monte Carlo methods.

    abstract:PURPOSE:When designing a collimation system for pencil beam spot scanning proton therapy, a decision must be made whether or not to rotate, or focus, the collimator to match beamlet deflection as a function of off-axis distance. If the collimator is not focused, the beamlet shape and fluence will vary as a function of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14139

    authors: Geoghegan TJ,Nelson NP,Flynn RT,Hill PM,Rana S,Hyer DE

    更新日期:2020-07-01 00:00:00

  • Nonlinear magnetic stereotaxis: three-dimensional, in vivo remote magnetic manipulation of a small object in canine brain.

    abstract::In a series of in vivo experiments on five adult canines, a small cylindrical permanent magnet (approximately 5-mm diameter x 5 mm long) was magnetically moved under fluoroscopic guidance from an occipital-lobe burr hole to a predetermined destination within the brain and then removed. On three of the animals, dorsal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596520

    authors: Grady MS,Howard MA 3rd,Molloy JA,Ritter RC,Quate EG,Gillies GT

    更新日期:1990-05-01 00:00:00

  • Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905050

    authors: Veiga C,Lourenço AM,Mouinuddin S,van Herk M,Modat M,Ourselin S,Royle G,McClelland JR

    更新日期:2015-02-01 00:00:00

  • 115In as a probe for the characterization of therapy bremsstrahlung beams and the detection of photoneutrons.

    abstract::Variation of the photoactivation rate across radiation fields of three different bremsstrahlung beams of two medical accelerators has been measured, making use of the photonuclear reactions in natural indium probes: 115In(y,y')115mIn and 115In(y,n)114mIn. The third nuclear reaction, 115In(n,y)116mIn, was used to detec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598558

    authors: Krmar M,Slivka J,Bikit I,Conkić L,Rudić A

    更新日期:1999-04-01 00:00:00

  • Cascade convolutional neural networks for automatic detection of thyroid nodules in ultrasound images.

    abstract:PURPOSE:It is very important for calculation of clinical indices and diagnosis to detect thyroid nodules from ultrasound images. However, this task is a challenge mainly due to heterogeneous thyroid nodules with distinct components are similar to background in ultrasound images. In this study, we employ cascade deep co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12134

    authors: Ma J,Wu F,Jiang T,Zhu J,Kong D

    更新日期:2017-05-01 00:00:00

  • Current status and future perspective of flattening filter free photon beams.

    abstract:PURPOSE:Flattening filters (FFs) have been considered as an integral part of the treatment head of a medical accelerator for more than 50 years. The reasons for the longstanding use are, however, historical ones. Advanced treatment techniques, such as stereotactic radiotherapy or intensity modulated radiotherapy have s...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3554643

    authors: Georg D,Knöös T,McClean B

    更新日期:2011-03-01 00:00:00