A convolution method for constructing primary beam profiles in the presence of beam modifiers.

Abstract:

:Empirical functions that describe primary beam profiles for radiotherapy treatment planning systems generally account for finite source size only on beams unmodified by blocks, wedges, or compensating filters. To incorporate the effects of extended sources on such modified beams and to treat the effect of an extended source consistent with the manner in which the unmodified beam is treated, the unmodified beam profile can be written as a convolution of an unknown source function with a collimator transmission profile. Using Fourier transforms, one can then solve for the source function. This source function is then convolved with a beam transmission function that has been modified by blocks, wedges, or compensating filters to obtain a primary beam profile. A number of examples are presented that demonstrate the calculations of the effects of beam modifiers on primary beam profiles.

journal_name

Med Phys

journal_title

Medical physics

authors

Starkschall G

doi

10.1118/1.596222

subject

Has Abstract

pub_date

1988-09-01 00:00:00

pages

657-61

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

15

pub_type

杂志文章
  • SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.

    abstract:PURPOSE:The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with Ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735542

    authors: Sheth N,Chen Y,Yang J

    更新日期:2012-06-01 00:00:00

  • WE-F-211-01: The Evolving Landscape of Scientific Publishing.

    abstract::The dissemination of scientific advances has changed little since the first peer-reviewed journal was published in 1665 - that is, until this past decade. The print journal, delivered by mail and stored on office shelves and in library reading rooms around the world, has been transformed by immediate, on-demand access...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736173

    authors: Armato S,Hendee W,Marshall C,Curran B

    更新日期:2012-06-01 00:00:00

  • Evaluation of diffusion models in breast cancer.

    abstract:PURPOSE:The purpose of this study is to investigate whether the microvascular pseudodiffusion effects resulting with non-monoexponential behavior are present in breast cancer, taking into account tumor spatial heterogeneity. Additionally, methodological factors affecting the signal in low and high diffusion-sensitizing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4927255

    authors: Panek R,Borri M,Orton M,O'Flynn E,Morgan V,Giles SL,deSouza N,Leach MO,Schmidt MA

    更新日期:2015-08-01 00:00:00

  • Loss of field flatness in AECL teletherapy units form misadjustment of the collimator.

    abstract::Atomic Energy of Canada Limited 60Co teletherapy units have adjustable collimator hinges to adapt to source diameters from 0.75 to 2.50 cm. Adjustment of the collimator hinge to the manfacturer's settings can cause a loss of radiation field flatness as high as 20% for large fields. The recommended settings appear to c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594170

    authors: Heintz PH

    更新日期:1975-03-01 00:00:00

  • SU-E-T-567: Improve Dose Conformity with IMRT Using Shorter Source to Tumor Distance.

    abstract:PURPOSE:To reduce the potential of late toxicity (tissue necrosis and cognitive function loss) from brain radiotherapy, we studied a novel planning technique for MLC-equipped linear accelerators (LINACS) that reduces the high doses delivered outside the PTV, enhancing radiation dose conformity. METHODS:The feasibility...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735656

    authors: Yang W,Sandler H,Fraass B

    更新日期:2012-06-01 00:00:00

  • Three dimensional intensity modulated brachytherapy (IMBT): dosimetry algorithm and inverse treatment planning.

    abstract:PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3456598

    authors: Shi C,Guo B,Cheng CY,Esquivel C,Eng T,Papanikolaou N

    更新日期:2010-07-01 00:00:00

  • Dynamic multiatlas selection-based consensus segmentation of head and neck structures from CT images.

    abstract:PURPOSE:Manual delineation of head and neck (H&N) organ-at-risk (OAR) structures for radiation therapy planning is time consuming and highly variable. Therefore, we developed a dynamic multiatlas selection-based approach for fast and reproducible segmentation. METHODS:Our approach dynamically selects and weights the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13854

    authors: Haq R,Berry SL,Deasy JO,Hunt M,Veeraraghavan H

    更新日期:2019-12-01 00:00:00

  • The impact of small motion on the visualization of coronary vessels and lesions in cardiac CT: A simulation study.

    abstract:PURPOSE:Coronary x-ray computed tomography angiography (CCTA) is used to non-invasively assess coronary artery geometry and has, combined with computational modeling, demonstrated the potential to identify physiologically significant lesions. These measurements require robust and accurate coronary imaging and delineati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12295

    authors: Contijoch F,Stayman JW,McVeigh ER

    更新日期:2017-07-01 00:00:00

  • Validation of the Gatortail method for accurate sizing of pulmonary vessels from 3D medical images.

    abstract:PURPOSE:Detailed characterization of changes in vessel size is crucial for the diagnosis and management of a variety of vascular diseases. Because clinical measurement of vessel size is typically dependent on the radiologist's subjective interpretation of the vessel borders, it is often prone to high inter- and intra-u...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12580

    authors: O'Dell WG,Gormaley AK,Prida DA

    更新日期:2017-12-01 00:00:00

  • SU-E-J-43: Autotuning Imaging Parameters in X-Ray Fluoroscopic Tracking for Dose Savings.

    abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734878

    authors: Siddique S,Fiume E,Jaffray D

    更新日期:2012-06-01 00:00:00

  • SU-E-T-267: Construction and Evaluation of a Neutron Wall to Shield a 15 MV Linac in a Low-Energy Vault.

    abstract:PURPOSE:To design and quantify the shielding efficacy of an inner Borated Polyethylene (BPE)wall for a 15 MV linac in a low energy vault. METHODS:A Varian TrueBeam linac with a maximum photon energy of 15 MV was installed in asmaller, preexisting vault. This vault originally housed a low-energy machine and did not hav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735334

    authors: Speiser M,Hager F,Foster R,Solberg T

    更新日期:2012-06-01 00:00:00

  • Computed tomography scanning with simultaneous patient translation.

    abstract::This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an intersc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596464

    authors: Crawford CR,King KF

    更新日期:1990-11-01 00:00:00

  • Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: effect of CT threshold.

    abstract:PURPOSE:The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD). METHODS:Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and exp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813906

    authors: Wang X,Duan J,Du Y,Shen N,He B,Yuan H

    更新日期:2013-08-01 00:00:00

  • "Battered data"--some clinical effects of the abuse of multiple regression methods: the NSD.

    abstract::The NSD equation, D = 1850 x T0.11 x N0.24, is a celebrated transmogrification of Cohen's two well-known collations of data on response to clinical irradiations (3 degrees erythema and 0.90 ablation of skin cancer) in which the relation of D and T is fixed by the data selected by Cohen and the additional constraint th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595034

    authors: Herbert DE Jr

    更新日期:1981-11-01 00:00:00

  • SU-E-T-389: Accuracy of a VMAT Planning System for Head and Neck Radiotherapy.

    abstract:PURPOSE:To determine the accuracy of VMAT treatment planning and delivery for patients undergoing radiotherapy in the head and neck. METHOD AND MATERIALS:A dosimetric study of a typical head and neck treatment plan has been carried out using Chamber, film and TLD's placed inside an anthropomorphic phantom. Lateral and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735478

    authors: Aldaais E,Tedeschi D,Gebreamlak W,Shieder T,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • Radiation attenuation by lead and nonlead materials used in radiation shielding garments.

    abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2426404

    authors: McCaffrey JP,Shen H,Downton B,Mainegra-Hing E

    更新日期:2007-02-01 00:00:00

  • Ultra-low-dose CT image denoising using modified BM3D scheme tailored to data statistics.

    abstract:PURPOSE:It is important to enhance image quality for low-dose CT acquisitions to push the ALARA boundary. Current state-of-the-art block-matching three-dimensional (BM3D) denoising scheme assumes white Gaussian noise (WGN) model. This study proposes a novel filtering module to be incorporated into the BM3D framework fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13252

    authors: Zhao T,Hoffman J,McNitt-Gray M,Ruan D

    更新日期:2019-01-01 00:00:00

  • Magnetic resonance and ultrasound image-guided navigation system using a needle manipulator.

    abstract:PURPOSE:Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is prefer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13958

    authors: Yamada A,Tokuda J,Naka S,Murakami K,Tani T,Morikawa S

    更新日期:2020-03-01 00:00:00

  • Displacement and strain estimation for evaluation of arterial wall stiffness using a familial hypercholesterolemia swine model of atherosclerosis.

    abstract:PURPOSE:To track variations in the deformation of the arterial wall noninvasively by estimating the accumulated displacement and strain over a cardiac cycle may provide useful indicators of vascular health. METHODS:In this paper, we propose an approach to track a region of interest (ROI) locally and estimate arterial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722746

    authors: Ge W,Krueger CG,Weichmann A,Shanmuganayagam D,Varghese T

    更新日期:2012-07-01 00:00:00

  • Monte Carlo and analytical model predictions of leakage neutron exposures from passively scattered proton therapy.

    abstract:PURPOSE:Stray neutron radiation is of concern after radiation therapy, especially in children, because of the high risk it might carry for secondary cancers. Several previous studies predicted the stray neutron exposure from proton therapy, mostly using Monte Carlo simulations. Promising attempts to develop analytical ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4829512

    authors: Pérez-Andújar A,Zhang R,Newhauser W

    更新日期:2013-12-01 00:00:00

  • Poster - Thur Eve - 04: Online review of beam output and profile constancy using statistical process control.

    abstract::The objective of this work was to create a comprehensive online tool to evaluate and review the performance of quality assurance measurements that assess beam output and profile constancy as soon as they are acquired using statistical process control. As part of routine quality assurance: output, flatness and symmetry...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740111

    authors: Chmielewski R,Abbas A,Yeung I

    更新日期:2012-07-01 00:00:00

  • An investigation into the robustness of dynamically collimated proton therapy treatments.

    abstract:PURPOSE:To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14208

    authors: Smith BR,Hyer DE,Culberson WS

    更新日期:2020-08-01 00:00:00

  • Radiation dose evaluation in tomosynthesis and C-arm cone-beam CT examinations with an anthropomorphic phantom.

    abstract:PURPOSE:The objective of this study was to evaluate organ dose and the effective dose to patients undergoing tomosynthesis (TS) and C-arm cone-beam computed tomography (CBCT) examinations and to compare the doses to those in multidetector CT (MDCT) scans. METHODS:Patient doses were measured with small sized silicon-ph...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3465045

    authors: Koyama S,Aoyama T,Oda N,Yamauchi-Kawaura C

    更新日期:2010-08-01 00:00:00

  • Quantitative simultaneous 99mTc/123I cardiac SPECT using MC-JOSEM.

    abstract::Simultaneous rest 99mTc-Sestamibi/ 123I-BMIPP cardiac SPECT imaging has the potential to replace current clinical 99mTc-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is diff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3063544

    authors: Ouyang J,Zhu X,Trott CM,El Fakhri G

    更新日期:2009-02-01 00:00:00

  • Correspondence optimization in 2D standardized carotid wall thickness map by description length minimization: A tool for increasing reproducibility of 3D ultrasound-based measurements.

    abstract:PURPOSE:The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966702

    authors: Chen Y,Chiu B

    更新日期:2016-12-01 00:00:00

  • Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields.

    abstract::Because of complex dose distributions and dose gradients that are created in three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), photon- and electron-energy spectra might change significantly with spatial locations and doses. This study examined variations in photon- and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710550

    authors: Jang SY,Liu HH,Mohan R,Siebers JV

    更新日期:2007-04-01 00:00:00

  • Resampling: an optimization method for inverse planning in robotic radiosurgery.

    abstract::By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design per...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2357020

    authors: Schweikard A,Schlaefer A,Adler JR Jr

    更新日期:2006-11-01 00:00:00

  • Reconstruction of 4-MV bremsstrahlung spectra from measured transmission data.

    abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595356

    authors: Huang PH,Kase KR,Bjärngard BE

    更新日期:1983-11-01 00:00:00

  • Spectrally resolved bioluminescence tomography using the reciprocity approach.

    abstract::Spectrally resolved bioluminescence optical tomography is an approach to recover images of, for example, Luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminesc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982138

    authors: Dehghani H,Davis SC,Pogue BW

    更新日期:2008-11-01 00:00:00

  • Quantum noise in detectors.

    abstract::The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595393

    authors: Rimkus D,Baily NA

    更新日期:1983-07-01 00:00:00