Abstract:
:The dissemination of scientific advances has changed little since the first peer-reviewed journal was published in 1665 - that is, until this past decade. The print journal, delivered by mail and stored on office shelves and in library reading rooms around the world, has been transformed by immediate, on-demand access to scientific discovery in electronic form. At the same time, the producers and consumers of that scientific content have greatly increased in number, and the balance between supply and demand has required innovations in the world of scientific publishing. In light of technological advances and societal expectations, the dissemination of scientific knowledge has assumed a new form, one that is dynamic and rapidly changing. The academic medical physicist must understand this evolution to ensure that appropriate decisions are made with regard to journal submission strategies and that relevant information on new findings is obtained in a timely manner. Medical Physics is adapting to these changes in substantive ways. This new scientific publishing landscape has implications for subscription models, targeted access through semantic enrichment, user interactivity with content, customized content delivery, and advertising opportunities. Many organizations, including the AAPM, depend on scientific publishing as a significant source of revenue, but web-based delivery raises the expectation that access should be free and threatens this model. The purpose of this symposium is to explore the factors that have contributed to the current state of scientific publishing, to anticipate future directions in this arena, and to convey how medical physicists may benefit from the expanded opportunities, both as authors and as readers. LEARNING OBJECTIVES:1. To appreciate the importance of scientific and clinical practice communication for the advancement of the medical physics field 2. To understand the roles of the Editorial Board and the Journal Business Management Committee in the promotion and advancement of Medical Physics 3. To explore technology-driven content delivery mechanisms and their role in facilitating content access and driving content usage 4. To understand the potential benefits and pitfalls of various economic and editorial models of scientific publications and the recent shifts away from the traditional role of libraries.
journal_name
Med Physjournal_title
Medical physicsauthors
Armato S,Hendee W,Marshall C,Curran Bdoi
10.1118/1.4736173subject
Has Abstractpub_date
2012-06-01 00:00:00pages
3963issue
6Part27eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595995
更新日期:1987-11-01 00:00:00
abstract:PURPOSE:A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-spec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3556589
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922686
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284974
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:The combination of nonhuman primates (NHPs) with the state-of-the-art molecular imaging technologies allows for within-subject longitudinal research aiming at gaining new insights into human normal and disease conditions and provides an ideal foundation for future translational studies of new diagnostic tools, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14333
更新日期:2020-09-01 00:00:00
abstract::The American Association of Physicists in Medicine Radiation Therapy Committee Task Group 36 report (TG-36) provides guidelines for managing radiation therapy of pregnant patients. Included in the report are data that can be used to estimate the dose to the fetus. The purpose of this study is to evaluate the accuracy ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2710332
更新日期:2007-04-01 00:00:00
abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1951427
更新日期:2005-08-01 00:00:00
abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2103447
更新日期:2005-11-01 00:00:00
abstract:PURPOSE:Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and ar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4801902
更新日期:2013-05-01 00:00:00
abstract:PURPOSE:In this work, the fabrication, operation, and evaluation of a probe-format graphite calorimeter - herein referred to as Aerrow - as an absolute clinical dosimeter of high-energy photon beams while in the presence of a B = 1.5 T magnetic field is described. Comparable to a cylindrical ionization chamber (IC) in ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13968
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:To generate hybrid VMAT-IMRT treatment plans by utilizing an IMRT beam-angle-optimality (BAO) search under a commercially available TPS without the aid of custom optimization software or high performance computing. METHODS:The high dose modulation provided by IMRT beams can be exploited to improve the quality ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735712
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4881096
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870378
更新日期:2014-05-01 00:00:00
abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596336
更新日期:1989-09-01 00:00:00
abstract::New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applicat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2837288
更新日期:2008-03-01 00:00:00
abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740174
更新日期:2012-07-01 00:00:00
abstract::In this paper, we present a unified framework to reconstruct images for both fan beam and cone beam projections. The important feature of our theoretical framework is that it does not depend on the classical concept of the Radon transform at all. This property allows us to directly generalize the ideas and techniques ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1577252
更新日期:2003-06-01 00:00:00
abstract::Ultrasound contrast agents consist of microscopically small encapsulated bubbles that oscillate upon insonification. To enhance diagnostic ultrasound imaging techniques and to explore therapeutic applications, these medical microbubbles have been studied with the aid of high-speed photography. We filmed medical microb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2133718
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process contr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4901520
更新日期:2014-12-01 00:00:00
abstract:PURPOSE:To investigate the optimal use of XR-RV3 GafChromic(®) films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. METHODS:XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922132
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4868455
更新日期:2014-04-01 00:00:00
abstract:PURPOSE:Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measure...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870985
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4963813
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:To eliminate or reduce the error to Pareto optimality that arises in Pareto surface navigation when the Pareto surface is approximated by a small number of plans. METHODS:The authors propose to project the navigated plan onto the Pareto surface as a postprocessing step to the navigation. The projection attempt...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4930252
更新日期:2015-10-01 00:00:00
abstract::Monte Carlo (MC) simulations were performed to estimate brachytherapy dose distributions for Collaborative Ocular Melanoma Study (COMS) eye plaques. Brachytherapy seed models 200, 6711, and CS-1 Rev2 carrying 103Pd, 125I, and 131Cs radionuclides, respectively, were modeled and benchmarked against previously published ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2940604
更新日期:2008-07-01 00:00:00
abstract::Optimal visualization of moving structures such as the heart and coronary arteries using digital radiographic imaging systems is a difficult problem that can involve tradeoffs between temporal, spatial, and density resolution. The motion dependence of four angiographic measures of vessel dimensions is given and demons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595651
更新日期:1985-11-01 00:00:00
abstract:PURPOSE:State of the art to access radiofrequency (RF) heating near implants is computer modeling of the devices and solving Maxwell's equations for the specific setup. For a set of input parameters, a fixed result is obtained. This work presents a theoretical approach in the alternating current (ac) limit, which can p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3637495
更新日期:2011-10-01 00:00:00
abstract::A new beam line for radiotherapy and radiosurgery with accelerated helium-ion beams has been set up at the Bevalac. The new treatment room has been equipped with a very precise patient positioner in order to utilize the superior dose localization properties of light-ion beams. The beam spreading and shaping system is ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596696
更新日期:1991-01-01 00:00:00
abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2218314
更新日期:2006-08-01 00:00:00
abstract::Interstitial brachytherapy for carcinoma of the prostate is achieved through the use of a configuration of radioactive seeds placed in a manner that delivers a customized, reasonably uniform dose to the target volume. Accurate dose delivery depends on both precise seed placement and reliable seed strength in the impla...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598877
更新日期:2000-01-01 00:00:00