Accelerated helium-ion beams for radiotherapy and stereotactic radiosurgery.

Abstract:

:A new beam line for radiotherapy and radiosurgery with accelerated helium-ion beams has been set up at the Bevalac. The new treatment room has been equipped with a very precise patient positioner in order to utilize the superior dose localization properties of light-ion beams. The beam spreading and shaping system is described, the trade-offs involved in positioning the beam modifying devices are discussed, and the physical properties of the generated radiation fields are reported. The Bragg peak modulation by axial beam stacking employing a variable range shifter is explained and the control system including beam monitoring and dosimetry is presented.

journal_name

Med Phys

journal_title

Medical physics

authors

Ludewigt BA,Chu WT,Phillips MH,Renner TR

doi

10.1118/1.596696

subject

Has Abstract

pub_date

1991-01-01 00:00:00

pages

36-42

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

18

pub_type

杂志文章
  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • SU-E-J-43: Autotuning Imaging Parameters in X-Ray Fluoroscopic Tracking for Dose Savings.

    abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734878

    authors: Siddique S,Fiume E,Jaffray D

    更新日期:2012-06-01 00:00:00

  • Application- and patient size-dependent optimization of x-ray spectra for CT.

    abstract::Although x-ray computed tomography (CT) has been in clinical use for over 3 decades, spectral optimization has not been a topic of great concern; high voltages around 120 kV have been in use since the beginning of CT. It is the purpose of this study to analyze, in a rigorous manner, the energies at which the patient d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3075901

    authors: Kalender WA,Deak P,Kellermeier M,van Straten M,Vollmar SV

    更新日期:2009-03-01 00:00:00

  • Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems--a contrast-detail phantom study.

    abstract::Flat-panel (FP) based digital radiography systems have recently been introduced as a new and improved digital radiography technology; it is important to evaluate and compare this new technology with currently widely used conventional screen/film (SF) and computed radiography (CR) techniques. In this study, the low-con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1408620

    authors: Rong XJ,Shaw CC,Liu X,Lemacks MR,Thompson SK

    更新日期:2001-11-01 00:00:00

  • Performance characteristics of A 150 plastic-equivalent gases in A 150 plastic proportional counters for 14.8-MeV neutrons.

    abstract::Two recently developed A 150 plastic-equivalent gas mixtures have been tested for suitability in proportional counter applications. Methane- and propane-based "tissue-equivalent" gases were also included for comparison purposes. Event-size weighted dose distributions were measured in a 14.8-MeV neutron beam. Resolutio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595536

    authors: DeLuca PM Jr,Schell MC,Pearson DW,Higgins PD,Attix FH

    更新日期:1984-07-01 00:00:00

  • Characterization of XR-RV3 GafChromic(®) films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors.

    abstract:PURPOSE:To investigate the optimal use of XR-RV3 GafChromic(®) films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. METHODS:XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922132

    authors: Farah J,Trianni A,Ciraj-Bjelac O,Clairand I,De Angelis C,Delle Canne S,Hadid L,Huet C,Jarvinen H,Negri A,Novák L,Pinto M,Siiskonen T,Waryn MJ,Knežević Ž

    更新日期:2015-07-01 00:00:00

  • Noncoplanar VMAT for nasopharyngeal tumors: Plan quality versus treatment time.

    abstract:PURPOSE:The authors investigated the potential of optimized noncoplanar irradiation trajectories for volumetric modulated arc therapy (VMAT) treatments of nasopharyngeal patients and studied the trade-off between treatment plan quality and delivery time in radiation therapy. METHODS:For three nasopharyngeal patients, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914863

    authors: Wild E,Bangert M,Nill S,Oelfke U

    更新日期:2015-05-01 00:00:00

  • Measurement of the replacement correction factor for parallel-plate chambers in electron fields.

    abstract::When parallel-plate chambers are used for dosimetry in electron fields, the AAPM dosimetry protocol recommends a value of 1.0 for the replacement correction factor, P(repl),pp,E, until further data become available. Here, P(repl),pp,E for five commercially available parallel-plate chambers was measured as a function o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596740

    authors: Reft CS,Kuchnir FT

    更新日期:1991-11-01 00:00:00

  • High-resolution fiber-optic dosimeters for microbeam radiation therapy.

    abstract:PURPOSE:A high resolution, water equivalent, optical and passive x-ray dosimeter has been constructed using plastic scintillator and optical fiber. This dosimeter has a peak edge-on spatial resolution of 100 μm in one dimension, with a 10 μm resolution dosimeter under investigation. The dosimeter design has a potential...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12209

    authors: Archer J,Li E,Petasecca M,Lerch M,Rosenfeld A,Carolan M

    更新日期:2017-05-01 00:00:00

  • High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array.

    abstract:PURPOSE:The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3694667

    authors: Qian X,Tucker A,Gidcumb E,Shan J,Yang G,Calderon-Colon X,Sultana S,Lu J,Zhou O,Spronk D,Sprenger F,Zhang Y,Kennedy D,Farbizio T,Jing Z

    更新日期:2012-04-01 00:00:00

  • An empirical model for independent dose verification of the Gamma Knife treatment planning.

    abstract::A formalism for an independent dose verification of the Gamma Knife treatment planning is developed. It is based on the approximation that isodose distribution for a single shot is in the shape of an ellipsoid in three-dimensional space. The dose profiles for a phantom along each of the three major axes are fitted to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1501139

    authors: Phaisangittisakul N,Ma L

    更新日期:2002-09-01 00:00:00

  • X-ray phase contrast imaging of the breast: analysis of tissue simulating materials.

    abstract:PURPOSE:Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794503

    authors: Vedantham S,Karellas A

    更新日期:2013-04-01 00:00:00

  • Technical note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks.

    abstract:PURPOSE:Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589131

    authors: Fayad H,Pan T,Clement JF,Visvikis D

    更新日期:2011-06-01 00:00:00

  • Combined kV and MV imaging for real-time tracking of implanted fiducial markers.

    abstract::In the presence of intrafraction organ motion, target localization uncertainty can greatly hamper the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT). To minimize the adverse dosimetric effect caused by tumor motion, a real-time knowledge of the tumor position is requ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2842072

    authors: Wiersma RD,Mao W,Xing L

    更新日期:2008-04-01 00:00:00

  • Application of radiomics for the prediction of HPV status for patients with head and neck cancers.

    abstract:PURPOSE:To perform radiomic analysis of primary tumors extracted from pretreatment contrast-enhanced computed tomography (CE-CT) images for patients with oropharyngeal cancers to identify discriminant features and construct an optimal classifier for the characterization and prediction of human papilloma virus (HPV) sta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13977

    authors: Bagher-Ebadian H,Lu M,Siddiqui F,Ghanem AI,Wen N,Wu Q,Liu C,Movsas B,Chetty IJ

    更新日期:2020-02-01 00:00:00

  • Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

    abstract:PURPOSE:The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging sys...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901551

    authors: Wu M,Keil A,Constantin D,Star-Lack J,Zhu L,Fahrig R

    更新日期:2014-12-01 00:00:00

  • Determining Pion, the correction factor for recombination losses in an ionization chamber.

    abstract::The 1983 AAPM protocol for the determination of absorbed dose from high-energy photon and electron beams recommends using Pion (the reciprocal of collection efficiency), as determined by the two-voltage technique, to correct for recombination losses in ionization chambers. Methods and data for the determination of ion...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595574

    authors: Weinhous MS,Meli JA

    更新日期:1984-11-01 00:00:00

  • Temporal subtraction in chest radiography: mutual information as a measure of image quality.

    abstract:PURPOSE:Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or "lung mask," of a previous radiographic image to align with the current image. The gray le...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3259712

    authors: Armato SG 3rd,Sensakovic WF,Passen SJ,Engelmann R,MacMahon H

    更新日期:2009-12-01 00:00:00

  • Structure and adaptation of arteries to pulsatile flow: the case of the ascending aorta.

    abstract:PURPOSE:The objectives are: (i) assess the development of the impedance of some arteries during the first decades of life; (ii) determine the influence of pulse rate in arterial impedance; (iii) compare the structure of some arterial segments with optimized structures with respect to blood flow; and (iv) explain the el...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876379

    authors: Silva C,Reis AH

    更新日期:2014-06-01 00:00:00

  • A statistical analysis of ionometrically measured 6-MV x-ray beam parameters.

    abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595642

    authors: Dawson DJ,Gribble MA

    更新日期:1984-09-01 00:00:00

  • Toward consensus on quantitative assessment of medical imaging systems.

    abstract::Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597511

    authors: Metz CE,Wagner RF,Doi K,Brown DG,Nishikawa RM,Myers KJ

    更新日期:1995-07-01 00:00:00

  • Automatic measurements of image geometry for online calibration of C-arm fluoroscopy.

    abstract::Calibrated C-arm fluoroscopy is used for a variety of surgical procedures where surgical tools and anatomical structures need to be located in space. Calibration can be performed online by combining measurements of the geometry of the image (center and radius) with measurements of a grid of fiducial markers. This arti...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.1781331

    authors: Archip N,Rohling R

    更新日期:2004-09-01 00:00:00

  • Development of the open-source dose calculation and optimization toolkit matRad.

    abstract:PURPOSE:We report on the development of the open-source cross-platform radiation treatment planning toolkit matRad and its comparison against validated treatment planning systems. The toolkit enables three-dimensional intensity-modulated radiation therapy treatment planning for photons, scanned protons and scanned carb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12251

    authors: Wieser HP,Cisternas E,Wahl N,Ulrich S,Stadler A,Mescher H,Müller LR,Klinge T,Gabrys H,Burigo L,Mairani A,Ecker S,Ackermann B,Ellerbrock M,Parodi K,Jäkel O,Bangert M

    更新日期:2017-06-01 00:00:00

  • DCE-MRI defined subvolumes of a brain metastatic lesion by principle component analysis and fuzzy-c-means clustering for response assessment of radiation therapy.

    abstract:PURPOSE:To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. METHODS:Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation thera...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4842556

    authors: Farjam R,Tsien CI,Lawrence TS,Cao Y

    更新日期:2014-01-01 00:00:00

  • Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum.

    abstract:PURPOSE:A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x ra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3223357

    authors: Marziani M,Taibi A,Di Domenico G,Gambaccini M

    更新日期:2009-10-01 00:00:00

  • On the effective point of measurement in megavoltage photon beams.

    abstract::This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the cham...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2201147

    authors: Kawrakow I

    更新日期:2006-06-01 00:00:00

  • Real-time direct diaphragm tracking using kV imaging on a standard linear accelerator.

    abstract:PURPOSE:As the predominant driver of respiratory motion, the diaphragm represents a key surrogate for motion management during the irradiation of thoracic cancers. Existing approaches to diaphragm tracking often produce phase-based estimates, suffer from lateral side failures or are not executable in real-time. In this...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13738

    authors: Hindley N,Keall P,Booth J,Shieh CC

    更新日期:2019-10-01 00:00:00

  • Automated matching and segmentation of lymphoma on serial CT examinations.

    abstract::In patients with lymphoma, identification and quantification of the tumor extent on serial CT examinations is critical for assessing tumor response to therapy. In this paper, we present a computer method to automatically match and segment lymphomas in follow-up CT images. The method requires that target lymph nodes in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2404617

    authors: Yan J,Zhao B,Curran S,Zelenetz A,Schwartz LH

    更新日期:2007-01-01 00:00:00

  • 3D image-guided robotic needle positioning system for small animal interventions.

    abstract:PURPOSE:This paper presents the design of a micro-CT guided small animal robotic needle positioning system. In order to simplify the robotic design and maintain a small targeting error, a novel implementation of the remote center of motion is used in the system. The system has been developed with the objective of achie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4771958

    authors: Bax JS,Waring CS,Sherebrin S,Stapleton S,Hudson TJ,Jaffray DA,Lacefield JC,Fenster A

    更新日期:2013-01-01 00:00:00

  • Photon attenuation in computed tomography.

    abstract::The analysis and understanding of results of computed tomography (CT) require an understanding of photon attenuation in matter. The high sensitivity and resolution of these devices coupled with the use of a polychromatic photon source require a level and breadth of understanding about photon attenuation not usually re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594199

    authors: McCullough EC

    更新日期:1975-11-01 00:00:00