Application of radiomics for the prediction of HPV status for patients with head and neck cancers.

Abstract:

PURPOSE:To perform radiomic analysis of primary tumors extracted from pretreatment contrast-enhanced computed tomography (CE-CT) images for patients with oropharyngeal cancers to identify discriminant features and construct an optimal classifier for the characterization and prediction of human papilloma virus (HPV) status. MATERIALS AND METHODS:One hundred and eighty seven patients with oropharyngeal cancers with known HPV status (confirmed by immunohistochemistry-p16 protein testing) were retrospectively studied as follows: Group A: 95 patients (19HPV- and 76HPV+) from the MICAII grand challenge. Group B: 92 patients (52HPV- and 40HPV+) from our institution. Radiomic features (172) were extracted from pretreatment diagnostic CE-CT images of the gross tumor volume (GTV). Levene and Kolmogorov-Smirnov's tests with absolute biserial correlation (>0.48) were used to identify the discriminant features between the HPV+ and HPV- groups. The discriminant features were used to train and test eight different classifiers. Area under receiver operating characteristic (AUC), positive predictive and negative predictive values (PPV and NPV, respectively) were used to evaluate the performance of the classifiers. Principal component analysis (PCA) was applied on the discriminant feature set and seven PCs were used to train and test a generalized linear model (GLM) classifier. RESULTS:Among 172 radiomic features only 12 radiomic features (from 3 categories) were significantly different (P < 0.05, |BSC| > 0.48) between the HPV+ and HPV- groups. Among the eight classifiers trained and applied for prediction of HPV status, the GLM showed the highest performance for each discriminant feature and the combined 12 features: AUC/PPV/NPV = 0.878/0.834/0.811. The GLM high prediction power was AUC/PPV/NPV = 0.849/0.731/0.788 and AUC/PPV/NPV = 0.869/0.807/0.870 for unseen test datasets for groups A and B, respectively. After eliminating the correlation among discriminant features by applying PCA analysis, the performance of the GLM was improved by 3.3%, 2.2%, and 1.8% for AUC, PPV, and NPV, respectively. CONCLUSIONS:Results imply that GTV's for HPV+ patients exhibit higher intensities, smaller lesion size, greater sphericity/roundness, and higher spatial intensity-variation/heterogeneity. Results are suggestive that radiomic features primarily associated with the spatial arrangement and morphological appearance of the tumor on contrast-enhanced diagnostic CT datasets may be potentially used for classification of HPV status.

journal_name

Med Phys

journal_title

Medical physics

authors

Bagher-Ebadian H,Lu M,Siddiqui F,Ghanem AI,Wen N,Wu Q,Liu C,Movsas B,Chetty IJ

doi

10.1002/mp.13977

subject

Has Abstract

pub_date

2020-02-01 00:00:00

pages

563-575

issue

2

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields.

    abstract::Because of complex dose distributions and dose gradients that are created in three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), photon- and electron-energy spectra might change significantly with spatial locations and doses. This study examined variations in photon- and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710550

    authors: Jang SY,Liu HH,Mohan R,Siebers JV

    更新日期:2007-04-01 00:00:00

  • Thermoluminescent dosimetry of the SourceTech Medical model STM1251 125I seed.

    abstract::Many new models of 125I seeds are being introduced, mainly due to the increase in prostate seed implants. We have evaluated the SourceTech Medical (STM), model STM1251, 125I seed using thermoluminescent dosimeters (TLDs) in a solid water phantom. TLD cubes, LiF TLD-100, with dimension 1 mm on each edge, were irradiate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1577251

    authors: Chiu-Tsao ST,Duckworth TL,Hsiung CY,Li Z,Williamson J,Patel NS,Harrison LB

    更新日期:2003-07-01 00:00:00

  • Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system.

    abstract::In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is approximately 0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2963994

    authors: Wen Z,Fahrig R,Williams ST,Pelc NJ

    更新日期:2008-09-01 00:00:00

  • The effect of rectal heterogeneity on wall dose in high dose rate brachytherapy.

    abstract::When treating prostate cancer using high dose rate (HDR) brachytherapy, overdosing the rectal wall may lead to post-treatment rectal complications. An area of concern is related to how the rectal wall dose is calculated by treatment planning systems (TPSs). TPSs are used to calculate the dose delivered to the rectal w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3031111

    authors: Kwan IS,Wilkinson D,Cutajar D,Lerch M,Rosenfeld A,Howie A,Bucci J,Chin Y,Perevertaylo VL

    更新日期:2009-01-01 00:00:00

  • Changes realized from extended bit-depth and metal artifact reduction in CT.

    abstract:PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4805102

    authors: Glide-Hurst C,Chen D,Zhong H,Chetty IJ

    更新日期:2013-06-01 00:00:00

  • Analysis of the significance of scattered radiation in reduced dose mammography, including magnification effects, scatter suppression, and focal spot and detector blurring.

    abstract::A systems analysis of reduced dose mammography with scatter removal has quantitatively specified the relationships between the several parameters in mammography systems. While the results are only preliminary in the sense that they need to be proven experimentally, they do seem to provide a good feel for the nature of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594540

    authors: Muntz EP

    更新日期:1979-03-01 00:00:00

  • Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool.

    abstract:PURPOSE:The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3271107

    authors: Iori M,Cagni E,Paiusco M,Munro P,Nahum AE

    更新日期:2010-01-01 00:00:00

  • Inverse planning incorporating organ motion.

    abstract::Accurate targeting is important in intensity-modulated radiation therapy (IMRT). The positional uncertainties of structures with respect to the external beams arise in part from random organ motion and patient setup errors. While it is important to improve immobilization and reduce the influence of organ motion, the r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599023

    authors: Li JG,Xing L

    更新日期:2000-07-01 00:00:00

  • Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner.

    abstract:PURPOSE:Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4943632

    authors: Patel T,Peppard H,Williams MB

    更新日期:2016-04-01 00:00:00

  • Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms.

    abstract:PURPOSE:Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. METHODS:The authors developed a computerized liver extraction scheme based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3395579

    authors: Suzuki K,Kohlbrenner R,Epstein ML,Obajuluwa AM,Xu J,Hori M

    更新日期:2010-05-01 00:00:00

  • Multiscale entropy of laser Doppler flowmetry signals in healthy human subjects.

    abstract:PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3512796

    authors: Humeau A,Buard B,Mahé G,Rousseau D,Chapeau-Blondeau F,Abraham P

    更新日期:2010-12-01 00:00:00

  • On the use of C-arm fluoroscopy for treatment planning in high dose rate brachytherapy.

    abstract::Treatment planning for brachytherapy requires the acquisition of geometrical information of the implant applicator and the patient anatomy. This is typically done using a simulator or a computed tomography scanner. In this study, we present a different method by which orthogonal images from a C-arm fluoroscopic machin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1598851

    authors: Liu L,Bassano DA,Prasad SC,Keshler BL,Hahn SS

    更新日期:2003-09-01 00:00:00

  • Evaluation of diffusion models in breast cancer.

    abstract:PURPOSE:The purpose of this study is to investigate whether the microvascular pseudodiffusion effects resulting with non-monoexponential behavior are present in breast cancer, taking into account tumor spatial heterogeneity. Additionally, methodological factors affecting the signal in low and high diffusion-sensitizing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4927255

    authors: Panek R,Borri M,Orton M,O'Flynn E,Morgan V,Giles SL,deSouza N,Leach MO,Schmidt MA

    更新日期:2015-08-01 00:00:00

  • A doorless entry system for high-energy radiation therapy rooms.

    abstract::A doorless entry system has been designed for use in high-energy radiation therapy rooms. The doorless entry improves patient access, safety and throughput, increases the physical safety for the radiation therapists, and avoids the significant cost of heavy shielding doors. The design meets concerns relating to radiat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598181

    authors: Dawson DJ,Wissing WW,Tonks RE

    更新日期:1998-02-01 00:00:00

  • Regularized iterative weighted filtered backprojection for helical cone-beam CT.

    abstract::Contemporary reconstruction methods employed for clinical helical cone-beam computed tomography (CT) are analytical (noniterative) but mathematically nonexact, i.e., the reconstructed image contains so called cone-beam artifacts, especially for higher cone angles. Besides cone artifacts, these methods also suffer from...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2966353

    authors: Sunnegårdh J,Danielsson PE

    更新日期:2008-09-01 00:00:00

  • Joint model of motion and anatomy for PET image reconstruction.

    abstract::Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respirato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2804721

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi O

    更新日期:2007-12-01 00:00:00

  • Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation.

    abstract:PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4812429

    authors: Driscoll B,Keller H,Jaffray D,Coolens C

    更新日期:2013-08-01 00:00:00

  • Investigation of effective decision criteria for multiobjective optimization in IMRT.

    abstract:PURPOSE:To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS:A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589128

    authors: Holdsworth C,Stewart RD,Kim M,Liao J,Phillips MH

    更新日期:2011-06-01 00:00:00

  • Objective performance characteristics of a new asymmetric screen-film system.

    abstract::A study of the objective imaging characteristics of a new asymmetric screen-film system is presented herein. The system is characterized by high x-ray absorption asymmetric screens, and a low-noise, high-contrast asymmetric film having near-zero crossover. Comparisons are made with the imaging characteristics of two w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597407

    authors: Van Metter R,Dickerson R

    更新日期:1994-09-01 00:00:00

  • Reconstruction of 4-MV bremsstrahlung spectra from measured transmission data.

    abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595356

    authors: Huang PH,Kase KR,Bjärngard BE

    更新日期:1983-11-01 00:00:00

  • Verification of IMRT dose distributions using a water beam imaging system.

    abstract::A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1413519

    authors: Li JS,Boyer AL,Ma CM

    更新日期:2001-12-01 00:00:00

  • A correction-based dose calculation algorithm for kilovoltage x rays.

    abstract::Frequent and repeated imaging procedures such as those performed in image-guided radiotherapy (IGRT) programs may add significant dose to radiosensitive organs of radiotherapy patients. It has been shown that kV-CBCT results in doses to bone that are up to a factor of 3-4 higher than those in surrounding soft tissue. ...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3014197

    authors: Ding GX,Pawlowski JM,Coffey CW

    更新日期:2008-12-01 00:00:00

  • A consistent set of neutron kerma coefficients from thermal to 150 MeV for biologically important materials.

    abstract::Neutron cross sections for nonelastic and elastic reactions on a range of elements have been evaluated for incident energies up to 150 MeV. These cross sections agree well with experimental cross section data for charged-particle production as well as neutron and photon production. Therefore they can be used to determ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598601

    authors: Chadwick MB,Barschall HH,Caswell RS,DeLuca PM,Hale GM,Jones DT,MacFarlane RE,Meulders JP,Schuhmacher H,Schrewe UJ,Wambersie A,Young PG

    更新日期:1999-06-01 00:00:00

  • Temporal subtraction in chest radiography: mutual information as a measure of image quality.

    abstract:PURPOSE:Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or "lung mask," of a previous radiographic image to align with the current image. The gray le...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3259712

    authors: Armato SG 3rd,Sensakovic WF,Passen SJ,Engelmann R,MacMahon H

    更新日期:2009-12-01 00:00:00

  • Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy.

    abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2794175

    authors: Surry KJ,Mills GR,Bevan K,Downey DB,Fenster A

    更新日期:2007-11-01 00:00:00

  • Measurement of x-ray attenuation coefficients of aqueous solutions of indocyanine green and glycated chitosan.

    abstract::We report our experimental results of measurements of x-ray attenuation coefficients of aqueous solutions of a light absorbing dye, indocyanine green, and an immunoadjuvant, glycated chitosan. In the treatment of metastatic tumors in rats using a novel laser immunotherapy these solutions were administered in situ. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598633

    authors: Xu F,Liu H,Wu X,Jiang H,Nordquist RE,Chen WR

    更新日期:1999-07-01 00:00:00

  • A method for reducing motion induced errors in T2-weighted magnetic resonance imaging.

    abstract::It is known that motion of an object imaged by magnetic resonance imaging leads to errors and artifacts in the image. This effect is especially important when a pulse sequence with long echo time (TE) and long TR is used to provide T2-weighted images. We have modified the usual spin warp imaging pulse sequence in a wa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596026

    authors: Joseph PM,Shetty A,Bonaroti EA

    更新日期:1987-07-01 00:00:00

  • Breast tumor segmentation in 3D automatic breast ultrasound using Mask scoring R-CNN.

    abstract:PURPOSE:Automatic breast ultrasound (ABUS) imaging has become an essential tool in breast cancer diagnosis since it provides complementary information to other imaging modalities. Lesion segmentation on ABUS is a prerequisite step of breast cancer computer-aided diagnosis (CAD). This work aims to develop a deep learnin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14569

    authors: Lei Y,He X,Yao J,Wang T,Wang L,Li W,Curran WJ,Liu T,Xu D,Yang X

    更新日期:2020-10-30 00:00:00

  • On using an adaptive neural network to predict lung tumor motion during respiration for radiotherapy applications.

    abstract::In this study we address the problem of predicting the position of a moving lung tumor during respiration on the basis of external breathing signals--a technique used for beam gating, tracking, and other dynamic motion management techniques in radiation therapy. We demonstrate the use of neural network filters to corr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2134958

    authors: Isaksson M,Jalden J,Murphy MJ

    更新日期:2005-12-01 00:00:00

  • Accuracy evaluation of a six-degree-of-freedom couch using cone beam CT and IsoCal phantom with an in-house algorithm.

    abstract:PURPOSE:The accuracy of a six degree of freedom (6DoF) couch was evaluated using a novel method. METHODS:Cone beam CT (CBCT) images of a 3D phantom (IsoCal) were acquired with different, known combinations of couch pitch and roll angles. Pitch and roll angles between the maximum allowable values of 357 and 3 degrees w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12342

    authors: Zhang Q,Driewer J,Wang S,Li S,Zhu X,Zheng D,Cao Y,Zhang J,Jamshidi A,Cox BW,Knisely JPS,Potters L,Klein EE

    更新日期:2017-08-01 00:00:00