Combined kV and MV imaging for real-time tracking of implanted fiducial markers.

Abstract:

:In the presence of intrafraction organ motion, target localization uncertainty can greatly hamper the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT). To minimize the adverse dosimetric effect caused by tumor motion, a real-time knowledge of the tumor position is required throughout the beam delivery process. The recent integration of onboard kV diagnostic imaging together with MV electronic portal imaging devices on linear accelerators can allow for real-time three-dimensional (3D) tumor position monitoring during a treatment delivery. The aim of this study is to demonstrate a near real-time 3D internal fiducial tracking system based on the combined use of kV and MV imaging. A commercially available radiotherapy system equipped with both kV and MV imaging systems was used in this work. A hardware video frame grabber was used to capture both kV and MV video streams simultaneously through independent video channels at 30 frames per second. The fiducial locations were extracted from the kV and MV images using a software tool. The geometric tracking capabilities of the system were evaluated using a pelvic phantom with embedded fiducials placed on a moveable stage. The maximum tracking speed of the kV/MV system is approximately 9 Hz, which is primarily limited by the frame rate of the MV imager. The geometric accuracy of the system is found to be on the order of less than 1 mm in all three spatial dimensions. The technique requires minimal hardware modification and is potentially useful for image-guided radiation therapy systems.

journal_name

Med Phys

journal_title

Medical physics

authors

Wiersma RD,Mao W,Xing L

doi

10.1118/1.2842072

subject

Has Abstract

pub_date

2008-04-01 00:00:00

pages

1191-8

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • Modification of the University of Washington Neutron Radiotherapy Facility for optimization of neutron capture enhanced fast-neutron therapy.

    abstract::A modified neutron production target assembly has been developed to provide improved performance of the proton-cyclotron-based neutron radiotherapy facility at the University of Washington for applications involving neutron capture enhanced fast-neutron therapy. The new target produces a neutron beam that yields essen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598839

    authors: Nigg DW,Wemple CA,Risler R,Hartwell JK,Harker YD,Laramore GE

    更新日期:2000-02-01 00:00:00

  • Monte Carlo dose calculations for a new ovoid shield system for carcinoma of the uterine cervix.

    abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598459

    authors: Weeks KJ

    更新日期:1998-12-01 00:00:00

  • The role of humidity and other correction factors in the AAPM TG-21 dosimetry protocol.

    abstract::A detailed derivation is presented of the formulas required to determine Ngas and Dmed in the AAPM TG-21 dosimetry protocol. This protocol specifies how to determine the absorbed dose in an electron or photon beam when using exposure or absorbed dose calibrated ion chambers. It is shown that the expression given in TG...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596292

    authors: Rogers DW,Ross CK

    更新日期:1988-01-01 00:00:00

  • Technical Note: An investigation of polarity effects for wide-angle free-air chambers.

    abstract:PURPOSE:Wide-angle free-air chambers (WAFACs) are used as primary standard measurement devices for establishing the air-kerma strength of low-energy, low-dose rate brachytherapy seeds. The National Research Council of Canada (NRC) is commissioning a primary standard wide-angle free-air chamber (NRC WAFAC) to serve the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4951727

    authors: Shen H,Culberson WS,Ross CK

    更新日期:2016-07-01 00:00:00

  • Feasibility of estimating regional mechanical properties of cerebral aneurysms in vivo.

    abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3355933

    authors: Balocco S,Camara O,Vivas E,Sola T,Guimaraens L,Gratama van Andel HA,Majoie CB,Pozo JM,Bijnens BH,Frangi AF

    更新日期:2010-04-01 00:00:00

  • Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.

    abstract:PURPOSE:MR thermometry based on the proton resonance frequency shift (PRFS) is the most commonly used method for the monitoring of thermal therapies. As the chemical shift of water protons is temperature dependent, the local temperature variation (relative to an initial baseline) may be calculated from time-dependent p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3309439

    authors: Viallon M,Terraz S,Roland J,Dumont E,Becker CD,Salomir R

    更新日期:2010-04-01 00:00:00

  • Image-based iterative compensation of motion artifacts in computed tomography.

    abstract:PURPOSE:This article presents an iterative method for compensation of motion artifacts for slowly rotating computed tomography (CT) systems. Patient's motion introduces inconsistencies among projections and yields severe reconstruction artifacts for free-breathing acquisitions. Streaks and doubling of structures can ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3244035

    authors: Schretter C,Rose G,Bertram M

    更新日期:2009-11-01 00:00:00

  • Optimal shielding design for bunkers of compact cyclotrons used in the production of medical radionuclides.

    abstract:PURPOSE:There are several options to consider in the design of a vault that will house a cyclotron for radioisotopes production with regards to the door entrance. Alternatives are a direct-shielded door, a simple maze, or a double-legged maze. In this work, the impact of the neutron and photon doses at the vault entran...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3515458

    authors: Facure A,França WF

    更新日期:2010-12-01 00:00:00

  • SU-E-J-81: Beveled Needle Tip Detection Error in Ultrasound-Guided Prostate Brachytherapy.

    abstract:PURPOSE:To quantify the needle tip detection errors in ultrasound images due to bevel-tip orientation in relation to the location on template grid. METHODS:Transrectal ultrasound (TRUS) system (BK Medical) with physical template grid and 18-gauge bevel-tip (20-deg beveled angle) brachytherapy needle (Bard Medical, Cov...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734916

    authors: Leu S,Ruiz B,Podder T

    更新日期:2012-06-01 00:00:00

  • Effects of point configuration on the accuracy in 3D reconstruction from biplane images.

    abstract::Two or more angiograms are being used frequently in medical imaging to reconstruct locations in three-dimensional (3D) space, e.g., for reconstruction of 3D vascular trees, implanted electrodes, or patient positioning. A number of techniques have been proposed for this task. In this simulation study, we investigate th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008467

    authors: Dmochowski J,Hoffmann KR,Singh V,Xu J,Nazareth DP

    更新日期:2005-09-01 00:00:00

  • Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams.

    abstract::An addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water in megavoltage photon beams is presented. This addendum continues the procedure laid out in TG-51 but new kQ data for photon beams, based on Monte Carlo simulations, are presented and recommendations are given to improve the accur...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4866223

    authors: McEwen M,DeWerd L,Ibbott G,Followill D,Rogers DW,Seltzer S,Seuntjens J

    更新日期:2014-04-01 00:00:00

  • Sheet beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticles.

    abstract:PURPOSE:X-ray fluorescence computed tomography (XFCT) experiments have typically used pencil beams for data acquisition, which yielded good quality images of gold nanoparticles (AuNP) but prolonged the imaging time. Here we propose three novel collimator geometries for use with faster sheet beam XFCT data acquisition. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12893

    authors: Dunning CAS,Bazalova-Carter M

    更新日期:2018-06-01 00:00:00

  • On the constancy in composition of polystyrene and polymethylmethacrylate plastics.

    abstract::Variations in the atomic composition, and mass and electron densities of polystyrene and polymethylmethacrylate (PMM) plastics were assessed from experimentally determined mass attenuation coefficients for 125I and 137Cs gamma rays. The means and standard deviations in the mass densities of 16 samples of PMM and 10 sa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594528

    authors: Schulz RJ,Nath R

    更新日期:1979-03-01 00:00:00

  • A quality management program in intravascular brachytherapy.

    abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1524167

    authors: Chakri A,Thomadsen B

    更新日期:2002-12-01 00:00:00

  • MO-C-BRCD-03: The Role of Informatics in Medical Physics and Vice Versa.

    abstract::Like Medical Physics, Imaging Informatics encompasses concepts touching every aspect of the imaging chain from image creation, acquisition, management and archival, to image processing, analysis, display and interpretation. The two disciplines are in fact quite complementary, with similar goals to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735777

    authors: Andriole K

    更新日期:2012-06-01 00:00:00

  • A scintillator-based approach to monitor secondary neutron production during proton therapy.

    abstract:PURPOSE:The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4963813

    authors: Clarke SD,Pryser E,Wieger BM,Pozzi SA,Haelg RA,Bashkirov VA,Schulte RW

    更新日期:2016-11-01 00:00:00

  • SU-E-J-100: Feasibility of Dose Calculation Using Combined Information of Cone-Beam and Multi-Slice CT Images.

    abstract:PURPOSE:The purpose of this study is to evaluate the feasibility of kilovoltage cone-beam CT (CBCT) images that are obtained with the Varian On-Board Imager in dose calculation at each radiation therapy. METHODS:CBCT images are commonly degraded by scattered radiations originating in the patient's body, and so the CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734936

    authors: Usui K,Ogawa K,Kunieda E

    更新日期:2012-06-01 00:00:00

  • SU-E-J-43: Autotuning Imaging Parameters in X-Ray Fluoroscopic Tracking for Dose Savings.

    abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734878

    authors: Siddique S,Fiume E,Jaffray D

    更新日期:2012-06-01 00:00:00

  • Technical Note: Imaging dose resulting from optimized procedures with limited-angle intrafractional verification system during stereotactic body radiation therapy lung treatment.

    abstract:PURPOSE:The limited-angle intrafractional verification (LIVE) system was developed to track tumor movement during stereotactic body radiation therapy (SBRT). However, the four-dimensional (4D) MV/kV imaging procedure results in additional radiation dose to patients. This study is to quantify imaging radiation dose from...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13511

    authors: Ding GX,Zhang Y,Ren L

    更新日期:2019-06-01 00:00:00

  • Absorbed dose in the presence of contrast agents during pediatric cardiac catheterization.

    abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594613

    authors: Callisen HH,Norman A,Adams FH

    更新日期:1979-11-01 00:00:00

  • Dose distributions around cylindrical 241Am sources for a clinical intracavitary applicator.

    abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596007

    authors: Nath R,Gray L,Park CH

    更新日期:1987-09-01 00:00:00

  • Simple design for a Styrofoam cutter.

    abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594206

    authors: Sorensen A,Goshaw L

    更新日期:1975-11-01 00:00:00

  • SU-E-J-194: The Impact of Different Imaging Measures on Treatment Response Assessment of Bone Metastases.

    abstract:PURPOSE:Several treatment response metrics, such as RECIST and PERCIST, have been established for assessing individual solid tumors. However, metastatic prostate cancer poses a unique challenge to these metrics because bone lesions are often numerous and non-measureable. This study investigated the impact of using diff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735035

    authors: Morrison C,Liu G,Jeraj R

    更新日期:2012-06-01 00:00:00

  • Novel detector design for reducing intercell x-ray cross-talk in the variable resolution x-ray CT scanner: a Monte Carlo study.

    abstract:PURPOSE:The variable resolution x-ray (VRX) CT scanner provides substantial improvement in the spatial resolution by matching the scanner's field of view (FOV) to the size of the object being imaged. Intercell x-ray cross-talk is one of the most important factors limiting the spatial resolution of the VRX detector. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3555035

    authors: Arabi H,Asl AR,Ay MR,Zaidi H

    更新日期:2011-03-01 00:00:00

  • Age-dependent dose calculations for common PET radionuclides and brain radiotracers in nonhuman primate computational models.

    abstract:PURPOSE:The combination of nonhuman primates (NHPs) with the state-of-the-art molecular imaging technologies allows for within-subject longitudinal research aiming at gaining new insights into human normal and disease conditions and provides an ideal foundation for future translational studies of new diagnostic tools, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14333

    authors: Xie T,Chen X,Zaidi H

    更新日期:2020-09-01 00:00:00

  • Comment on: Polarity effects and apparent ion recombination in microionization chambers Med. Phys. 43(5), 2141-2152 (2016).

    abstract::In a recent paper of Miller et al. (Med. Phys. 43(5), 2141-2152 (2016), the voltage dependence polarity effect of microionization chambers was studied. It was identified that polarity effect arises from the difference in electric potential between the collecting electrode and the guard electrode, which in turn deforms...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1002/mp.12019

    authors: Brivio D,Sajo E,Zygmanski P

    更新日期:2017-03-01 00:00:00

  • SU-E-T-590: Procedure for Verification and Inter-Comparison of IMRT Beam Models.

    abstract:PURPOSE:The implementation of an accurate beam model is an integral part of the commissioning of any planning system. This process is especially challenging in the case of IMRT beam models owing to the complexity of small field sizes and MLC leaf-end and tongue-and-groove effects. The question of how to judge the quali...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735679

    authors: Veltchev I,Fourkal E,Price R,Ma C

    更新日期:2012-06-01 00:00:00

  • Inverse planning incorporating organ motion.

    abstract::Accurate targeting is important in intensity-modulated radiation therapy (IMRT). The positional uncertainties of structures with respect to the external beams arise in part from random organ motion and patient setup errors. While it is important to improve immobilization and reduce the influence of organ motion, the r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599023

    authors: Li JG,Xing L

    更新日期:2000-07-01 00:00:00

  • Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum.

    abstract:PURPOSE:A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x ra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3223357

    authors: Marziani M,Taibi A,Di Domenico G,Gambaccini M

    更新日期:2009-10-01 00:00:00

  • Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy.

    abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598479

    authors: Allen DA,Beynon TD,Green S

    更新日期:1999-01-01 00:00:00